Test report

FCC ID: IKQFMT6

Test Report

Download: PDF
FCCID_3516461

                                      TEST REPORT


                                                FCC ID: IKQFMT6
                                           Product: FM Transmitter
                                                 Model No.: FMT6
                                          Additional Model No.: N/A
                                            Trade Mark: SCOSCHE
                                        Report No.: TCT170720E003
                                          Issued Date: Aug. 05, 2017



                                                      Issued for:

                                            Scosche Industries Inc
                    1550 Pacific Ave, Oxnard, California, 93033 United States



                                                      Issued By:

                              Shenzhen Tongce Testing Lab.
       1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
                              Shenzhen, Guangdong, China
                                   TEL: +86-755-27673339
                                            FAX: +86-755-27673332




Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab.
       This document may be altered or revised by Shenzhen Tongce Testing Lab. personnel only, and shall be noted in
       the revision section of the document. The test results in the report only apply to the tested sample.




   Hotline: 400-6611-140        Tel: 86-755-27673339          Fax: 86-755-27673332          http://www.tct-lab.com


                                                                                                         Report No.: TCT170720E003



                                              TABLE OF CONTENTS

1. Test Certification ..................................................................................... 3
2. Test Result Summary .............................................................................. 4
3. EUT Description ....................................................................................... 5
4. Genera Information.................................................................................. 6
     4.1. Test Environment and Mode................................................................................. 6
     4.2. Description of Support Units ................................................................................ 6
5. Facilities and Accreditations .................................................................. 7
     5.1. Facilities ................................................................................................................. 7
     5.2. Location ................................................................................................................. 7
     5.3. Measurement Uncertainty ..................................................................................... 7
6. Test Results and Measurement Data ..................................................... 8
     6.1. Antenna Requirement ........................................................................................... 8
     6.2. Conducted Emission ............................................................................................. 9
     6.3. Radiated Emission Measurement ...................................................................... 10
     6.4. Occupied Bandwidth ........................................................................................... 16
Appendix A: Photographs of Test Setup
Appendix B: Photographs of EUT




                                                                                                                     Page 2 of 26

   Hotline: 400-6611-140           Tel: 86-755-27673339            Fax: 86-755-27673332             http://www.tct-lab.com


                                                                            Report No.: TCT170720E003


1. Test Certification
 Product:          FM Transmitter
 Model No.:        FMT6
 Additional
                   N/A
 Model No.:
 Trade Mark:       SCOSCHE
 Applicant:        Scosche Industries Inc

 Address:          1550 Pacific Ave, Oxnard, California, 93033 United States

 Manufacturer: SAGE HUMAN ELECTRONICS INTERNATIONAL CO., LTD.

                   4F., A Building, Rongli Industrial Park, No.2 Guiyuan Rd., Guihua
 Address:
                   Community, Guanlan Town, Longhua New Dist., Shenzhen, China
 Date of Test:     Jul. 03 – Jul. 10, 2017
 Applicable
                   FCC CFR Title 47 Part 15 Subpart C Section 15.239
 Standards:


The above equipment has been tested by Shenzhen Tongce Testing Lab. and found
compliance with the requirements set forth in the technical standards mentioned above. The
results of testing in this report apply only to the product/system, which was tested. Other
similar equipment will not necessarily produce the same results due to production tolerance
and measurement uncertainties.




              Tested By:                                     Date:       Jul. 10, 2017

                                 Jin Wang

          Reviewed By:                                       Date:       Aug. 05, 2017


                                  Joe Zhou

          Approved By:                                       Date:       Aug. 05, 2017

                                   Tomsin




                                                                                     Page 3 of 26

 Hotline: 400-6611-140     Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                             Report No.: TCT170720E003



2.       Test Result Summary

                                                           CFR 47 Section
             Requirement                                                                        Result
                                                            IC Paragraph
        Antenna requirement                                     §15.203                         PASS
     AC Power Line Conducted
                                                                §15.207                           N/A
           Emission
         Field strength of the
                                                              §15.239 (b)                       PASS
         fundamental signal
         Spurious emissions                         §15.239 (b) (c)/ §15.209                    PASS
        Occupied Bandwidth                                    §15.215 (c)                       PASS
 Note:
       1. PASS: Test item meets the requirement.
       2. Fail: Test item does not meet the requirement.

       3. N/A: Test case does not apply to the test object.

       4. The test result judgment is decided by the limit of test standard.




                                                                                                        Page 4 of 26

     Hotline: 400-6611-140         Tel: 86-755-27673339            Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                          Report No.: TCT170720E003



3. EUT Description
 Product:                         FM Transmitter
 Model No.:                       FMT6
 Additional Model No.:            N/A
 Trade Mark:                      SCOSCHE
 Hardware Version:                FMT6-QN8027-V1.0
 Software Version:                V1.0
 Operation Frequency:             88.1MHz – 107.9MHz
 Channel Separation:              200 kHz
 Number of Channel:               20CH(See NOTE 2)
 Modulation
                                  FM
 Technology:
 Antenna Type:                    external Antenna
 Antenna Gain:                    0dBi
 Power Supply:                    DC3.0V (2 Pcs AAA batteries)


 Operation Frequency Each of Channel
 Channel Frequency Channel Frequency Channel Frequency Channel                                   Frequency
    1     88.1 MHz    6     90.1 MHz   11    106.1 MHz   16                                      107.1 MHz
    2     88.3 MHz    7     90.3 MHz   12    106.3 MHz   17                                      107.3 MHz
    3     88.5 MHz    8     90.5 MHz   13    106.5 MHz   18                                      107.5 MHz
    4     88.7 MHz    9     90.7 MHz   14    106.7 MHz   19                                      107.7 MHz
    5     88.9 MHz    10    90.9 MHz   15    106.9 MHz   20                                      107.9 MHz

  Note:
     In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle
     frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see
     below:


                                         Channel                Frequency
                                    The lowest channel          88.1 MHz
                                   The middle channel            90.9 MHz
                                   The highest channel 107.9 MHz




                                                                                                    Page 5 of 26

  Hotline: 400-6611-140      Tel: 86-755-27673339        Fax: 86-755-27673332         http://www.tct-lab.com


                                                                                            Report No.: TCT170720E003



4. Genera Information
4.1. Test Environment and Mode
  Operating Environment:
     Temperature:                                          24.0 C
     Humidity:                                             54 % RH
     Atmospheric Pressure:                                 1010 mbar

  Test Mode:
     Operation mode:                                       Keep the EUT in continuous transmitting
                                                           with modulation
  The sample was placed (0.8m below 1GHz, 1.5m above 1GHz) above the ground
  plane of 3m chamber. Measurements in both horizontal and vertical polarities were
  performed. During the test, each emission was maximized by: having the EUT
  continuously working, investigated all operating modes, rotated about all 3 axis (X, Y &
  Z) and considered typical configuration to obtain worst position, manipulating
  interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in
  both horizontal and vertical polarizations. The emissions worst-case are shown in Test
  Results of the following pages.


4.2. Description of Support Units
 The EUT has been tested as an independent unit together with other necessary
 accessories or support units. The following support units or accessories were used to
 form a representative test configuration during the tests.


    Equipment              Model No.             Serial No.           FCC ID/DOC               Trade Name

            /                     /                    /                      /                        /
 Note:
     1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test.
     2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended
         use.




                                                                                                       Page 6 of 26

  Hotline: 400-6611-140       Tel: 86-755-27673339         Fax: 86-755-27673332         http://www.tct-lab.com


                                                                              Report No.: TCT170720E003



5.       Facilities and Accreditations
5.1. Facilities
 The test facility is recognized, certified, or accredited by the following organizations:
 ● FCC - Registration No.: 572331
   Shenzhen Tongce Testing Lab
   The 3m Semi-anechoic chamber has been registered and fully described in a report
   with the (FCC) Federal Communications Commission. The acceptance letter from the
   FCC is maintained in our files.
 ● IC - Registration No.: 10668A-1
   The 3m Semi-anechoic chamber of Shenzhen TCT Testing Technology Co., Ltd. has
   been registered by Certification and Engineering Bureau of Industry Canada for radio
   equipment testing
5.2. Location
     Shenzhen Tongce Testing Lab
     Address: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
              Shenzhen, Guangdong, China
     TEL: +86-755-27673339
5.3. Measurement Uncertainty
 The reported uncertainty of measurement y ± U, where expended uncertainty U is based
 on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of
 confidence of approximately 95 %.
     No.     Item                                                               MU
     1       Conducted Emission                                                 ±2.56dB
     2       RF power, conducted                                                ±0.12dB
     3       Spurious emissions, conducted                                      ±0.11dB
     4       All emissions, radiated(<1G)                                       ±3.92dB
     5       All emissions, radiated(>1G)                                       ±4.28dB
     6       Temperature                                                        ±0.1°C
     7       Humidity                                                           ±1.0%




                                                                                       Page 7 of 26

     Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                              Report No.: TCT170720E003



6.      Test Results and Measurement Data
6.1. Antenna Requirement

     Standard requirement:           FCC Part15 C Section 15.203 /247(c)
     15.203 requirement:
     An intentional radiator shall be designed to ensure that no antenna other than that
     furnished by the responsible party shall be used with the device. The use of a
     permanently attached antenna or of an antenna that uses a unique coupling to the
     intentional radiator, the manufacturer may design the unit so that a broken antenna
     can be replaced by the user, but the use of a standard antenna jack or electrical
     connector is prohibited.
     15.247(c) (1)(i) requirement:
     (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed.
     Point-to-point operations may employ transmitting antennas with directional gain
     greater than 6dBi provided the maximum conducted output power of the intentional
     radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna
     exceeds 6dBi.
     E.U.T Antenna:
     The FM antenna is internal antenna which permanently attached, and the best case
     gain of the antenna is 0dBi.




       FM ANT




                                                                                       Page 8 of 26

     Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                           Report No.: TCT170720E003



6.2. Conducted Emission
6.2.1. Test Specification

  Test Requirement:       FCC Part15 C Section 15.207
  Test Method:            ANSI C63.10:2013
  Frequency Range:        150 kHz to 30 MHz
  Receiver setup:         RBW=9 kHz, VBW=30 kHz, Sweep time=auto

                             Frequency range                 Limit (dBuV)
                                  (MHz)              Quasi-peak        Average
  Limits:                        0.15-0.5             66 to 56*        56 to 46*
                                   0.5-5                 56               46
                                   5-30                  60               50




  Test Setup:




  Test Mode:              Refer to section 4.1 for details
                          1. The E.U.T is connected to the main power through a line
                             impedance stabilization network (L.I.S.N.). This provides a
                             50ohm/50uH coupling impedance for the measuring
                             equipment.
                          2. The peripheral devices are also connected to the main power
                             through a LISN that provides a 50ohm/50uH coupling
  Test Procedure:            impedance with 50ohm termination. (Please refer to the block
                             diagram of the test setup and photographs).
                          3. Both sides of A.C. line are checked for maximum conducted
                             interference. In order to find the maximum emission, the
                             relative positions of equipment and all of the interface cables
                             must be changed according to ANSI C63.10:2013 on
                             conducted measurement.
  Test Result:            The EUT is powered by 2 pcs AAA batteries, so not applicable.




                                                                                    Page 9 of 26

  Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                Report No.: TCT170720E003



6.3. Radiated Emission Measurement
6.3.1. Test Specification

  Test Requirement:               FCC Part15 C Section 15.209
  Test Method:                    ANSI C63.10: 2013
  Frequency Range:                9 kHz to 1 GHz
  Measurement Distance:           3m
  Antenna Polarization:           Horizontal & Vertical
                                    Frequency      Detector       RBW       VBW         Remark
                                   9kHz- 150kHz   Quasi-peak     200Hz      1kHz    Quasi-peak Value
  Receiver Setup:                    150kHz-      Quasi-peak      9kHz     30kHz    Quasi-peak Value
                                      30MHz
                                   30MHz-1GHz     Quasi-peak     100KHz   300KHz    Quasi-peak Value
                                                                 Limit (dBuV/m
                                         Frequency                                      Remark
                                                                     @3m)
                                                                        48           Average Value
                                         88-108MHz
                                                                        68            Peak Value
  Limit(Field strength of the     Note: Fcc part15.239 (b) The field strength of any emissions within
                                        the permitted 200 kHz band shall not exceed 250
  fundamental signal):                  microvolts/meter at 3 meters. The emission limit in this
                                        paragraph is based on measurement instrumentation
                                        employing an average detector. The provisions in Section
                                        15.35 for limiting peak emissions apply.



                                           Frequency           Limit (dBuV/m @3m)       Remark
                                         30MHz-88MHz                    40.0        Quasi-peak Value
  Limit(Spurious Emissions):            88MHz-216MHz                    43.5        Quasi-peak Value
                                       216MHz-960MHz                    46.0        Quasi-peak Value
                                         960MHz-1GHz                    54.0        Quasi-peak Value


                                  Emissions radiated outside of the specified frequency
                                  bands, except for harmonics, shall be attenuated by at
  Limit (band edge) :             least 50 dB below the level of the fundamental or to the
                                  general radiated emission limits in Section 15.209,
                                  whichever is the lesser attenuation.
                                  1. The EUT was placed on the top of a rotating table 0.8
                                      meters above the ground at a 3 meter camber in
                                      below 1GHz, 1.5m above the ground in above
                                      1GHz. The table was rotated 360 degrees to
                                      determine the position of the highest radiation.
  Test Procedure:                 2. The EUT was set 3 meters away from the
                                      interference-receiving antenna, which was mounted
                                      on the top of a variable-height antenna tower.
                                  3. The antenna height is varied from one meter to four
                                      meters above the ground to determine the maximum
                                      value of the field strength. Both horizontal and

                                                                                        Page 10 of 26

  Hotline: 400-6611-140   Tel: 86-755-27673339    Fax: 86-755-27673332       http://www.tct-lab.com


                                                                         Report No.: TCT170720E003


                                    vertical polarizations of the antenna are set to make
                                    the measurement.
                                4. For each suspected emission, the EUT was arranged
                                    to its worst case and then the antenna was tuned to
                                    heights from 1 meter to 4 meters and the rotatable
                                    table was turned from 0 degrees to 360 degrees to
                                    find the maximum reading.
                                5. The test-receiver system was set to Peak Detect
                                    Function and Specified Bandwidth with Maximum
                                    Hold Mode.
                                6. If the emission level of the EUT in peak mode was
                                   10dB lower than the limit specified, then testing could
                                   be stopped and the peak values of the EUT would be
                                   reported. Otherwise the emissions that did not have
                                   10dB margin would be re-tested one by one using
                                   peak, quasi-peak or average method as specified and
                                   then reported in a data sheet.
                                For radiated emissions below 30MHz




                                30MHz to 1GHz
Test setup:




Test Mode:                      Refer to section 4.1 for details
Test results:                   PASS




                                                                                  Page 11 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                                  Report No.: TCT170720E003


6.3.2. Test Instruments

                                     Radiated Emission Test Site (966)
          Name of                                                                 Serial
                                  Manufacturer                Model                               Calibration Due
         Equipment                                                               Number
                                ROHDE&SCHW
       Test Receiver                                          ESVD                100008            Oct. 13, 2017
                                    ARZ
                                ROHDE&SCHW
    Spectrum Analyzer                                          FSQ                200061            Oct. 13, 2017
                                    ARZ
                                 EM Electronics
        Pre-amplifier             Corporation               EM30265             07032613            Oct. 13, 2017
                                   CO.,LTD
        Pre-amplifier                     HP                  8447D           2727A05017            Oct. 13, 2017

       Loop antenna                   ZHINAN               ZN30900A                12024            Oct. 13, 2017

   Broadband Antenna               Schwarzbeck             VULB9163                 340             Oct. 13, 2017
       Horn Antenna                Schwarzbeck           BBHA 9120D                 631             Oct. 13, 2017
       Antenna Mast                    Keleto               CC-A-4M                 N/A                    N/A
         Coax cable
                                         TCT               RE-low-01                N/A             Oct. 13, 2017
        (9KHz-1GHz)
         Coax cable
                                         TCT               RE-high-02               N/A             Oct. 13, 2017
       (9KHz-40GHz)
         Coax cable
                                         TCT               RE-low-03                N/A             Oct. 13, 2017
        (9KHz-1GHz)
         Coax cable
                                         TCT               RE-high-04               N/A             Oct. 13, 2017
       (9KHz-40GHz)

                                      Shurple
    EMI Test Software                                       EZ-EMC                  N/A                    N/A
                                    Technology


Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to international
system unit (SI).




                                                                                                           Page 12 of 26

   Hotline: 400-6611-140         Tel: 86-755-27673339          Fax: 86-755-27673332          http://www.tct-lab.com


                                                                                             Report No.: TCT170720E003



6.3.3. Test Data
 Field Strength of Fundamental

       Frequency             Emission PK/AV             Horizontal         Limits PK/AV             Margin
         (MHz)                 (dBuV/m)                  /Vertical           (dBuV/m)                (dB)
           88.1                  36.51(AV)                    H                   48                 -11.49
           88.1                  38.71(PK)                    H                   68                 -29.29
           88.1                  30.24(AV)                    V                   48                 -17.76
           88.1                  31.55(PK)                    V                   68                 -36.45

       Frequency             Emission PK/AV             Horizontal         Limits PK/AV             Margin
         (MHz)                 (dBuV/m)                  /Vertical           (dBuV/m)                (dB)
           90.9                  36.94(AV)                    H                   48                 -11.06
           90.9                  39.12(PK)                    H                   68                 -28.88
           90.9                  30.82(AV)                    V                   48                 -17.18
           90.9                  32.04(PK)                    V                   68                 -35.96

       Frequency             Emission PK/AV             Horizontal         Limits PK/AV             Margin
         (MHz)                 (dBuV/m)                  /Vertical           (dBuV/m)                (dB)
          107.9                  35.75(AV)                    H                   48                 -12.25
          107.9                  36.48(PK)                    H                   68                 -31.52
          107.9                  29.24(AV)                    V                   48                 -18.76
          107.9                  30.71(PK)                    V                   68                 -37.29

 Spurious Emissions
 Frequency Range (9 kHz-30MHz)
    Frequency (MHz)                       Level@3m (dBμV/m)                       Limit@3m (dBμV/m)
              --                                  --                                       --
              --                                  --                                       --
              --                                  --                                       --
              --                                  --                                       --
 Note: 1. Emission Level=Reading+ Cable loss-Antenna factor-Amp factor
       2. The emission levels are 20 dB below the limit value, which are not reported. It is deemed to comply with the
          requirement




                                                                                                       Page 13 of 26

  Hotline: 400-6611-140       Tel: 86-755-27673339         Fax: 86-755-27673332          http://www.tct-lab.com


                                                                           Report No.: TCT170720E003

                                 Frequency Range (30MHz-1GHz)
Horizontal:




                 Fundamental Frequency




                                                                                   Page 14 of 26

  Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                            Report No.: TCT170720E003



Vertical:




                 Fundamental Frequency




  Note:1) QP= Quasi-peak
       2) Emission Level = Reading Level + Antenna Factor + Cable Loss.
       3)Measurements were conducted in all three channels (high, middle, low) and
       the worst case Mode (Middle channel) was submitted only.




                                                                                    Page 15 of 26

   Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


I c I                                                                       Reporti: rorimeramom

6.4. Occupled Bandwidth
6.4.1. Test Specification

  Test Requirement:               FCG Part15 G Section 15.215()
  Test Method:                    laNs! Ces. to: 2013
  Limit:                          200z
                                  7. According To Ins falow Test—selup, keep Ine relalive
                                      position between the artficial antennaand the EUT.
                                  2. Set to the maximum power selting and enable the
                                      EUT transmit continuously.
                                  3. Use the following spectrum analyzer seings for
  Test Procedure:                     2008 Bandwidih measurement.
                                      Span = approximately 2 to 3 times the 20 dB
                                      bancividth, centered on a hopping channel; RBW>=
                                      1%of the 20 dB bandwicth; VBWRBW; Sweep =
                                      auto; Detector function = peak; Trace = max hald.
                                  4. Measure and record the results in the test report



                                   SpectrumAnabyzer
  Test Mode:                      Refer to section 4.1 for dotails
  Test results:                   PASS


6.4.2. Test Instruments

                                        RF Test Room

      Equipment           Manufacturer       Model       Serial Number      Calibration Due
   Spectrum Analyzer          Res               rsu          200054           Oct. 13, 2017
 Nate: Thecaliratoniteral fhe abovefesistuments is 12 morths and tcaltvatons ar tacentteto
       intrnatonal system unt 30




                                                                               Pase i8 or 2e
  Hallines s00—Sert—1s0   Tob no—res—are7e000    P             270002 Mioiiwwndetlib.com


                                                                            Report No.: TCT170720E003



6.4.3. Test data
                             20dB Occupy
      Test Channel                                     Limit (kHz)           Conclusion
                            Bandwidth (kHz)
          Lowest                39.42                     200                   PASS
          Middle                  39.41                   200                   PASS
          Highest                 39.42                   200                   PASS

  Test plots as follows:




                                                                                    Page 17 of 26

  Hotline: 400-6611-140    Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                                                                                               Report No.: TCT170720E003



                                                                        Lowest channel
                                                                                       * RBW   1   kHz        Delta    2       [T1    ]
                                                                                       * VBW   3   kHz                                0.17      dB
                         Ref    -30   dBm                      * Att    0   dB           SWT   100   ms           39.423076923                  kHz

                         -30 O f f s e t      1    dB                                                         Marker       1    [T1       ]
                                                                                                                                 -76.81         dBm
                                                                                                                  88.081588462                  MHz    A
                         -40

                  1 PK
                  MAXH
                         -50
                                                                                                                                                      LVL

                                      D1   -57.21       dBm
                         -60




                         -70
                                                                    1                                     2
                                            D2    -77.21      dBm
                         -80


                                                                                                                                                      3DB
                         -90




                         -100




                         -110




                         -120



                         -130

                         Center       88.1    MHz                                10   kHz/                                 Span           100   kHz




                  Date: 7.JUL.2017           18:34:38


                                                                        Middle channel
                                                                                       * RBW   1   kHz        Delta    2       [T1    ]
                                                                                       * VBW   3   kHz                                0.69      dB
                         Ref    -30   dBm                      * Att    0   dB           SWT   100   ms           39.405128205                  kHz

                         -30 O f f s e t      1    dB                                                         Marker       1    [T1       ]
                                                                                                                                 -78.02         dBm
                                                                                                                  90.881588462                  MHz    A
                         -40

                  1 PK
                  MAXH
                         -50
                                                                                                                                                      LVL


                                      D1   -57.85       dBm
                         -60




                         -70

                                                                    1                                     2
                                            D2    -77.85      dBm
                         -80


                                                                                                                                                      3DB
                         -90




                         -100




                         -110




                         -120



                         -130

                         Center       90.9    MHz                                10   kHz/                                 Span           100   kHz




                  Date: 7.JUL.2017           18:35:31


                                                                        Highest channel
                                                                                       * RBW   1   kHz        Delta    2       [T1    ]
                                                                                       * VBW   3   kHz                               -0.50      dB
                         Ref    -30   dBm                      * Att    0   dB           SWT   100   ms           39.423076923                  kHz

                         -30 O f f s e t      1    dB                                                         Marker       1    [T1       ]
                                                                                                                                 -81.04         dBm
                                                                                                                 107.881588462                  MHz    A
                         -40

                  1 PK
                  MAXH
                         -50
                                                                                                                                                      LVL



                         -60
                                      D1   -61.52       dBm



                         -70


                                                                    1                                     2
                         -80
                                            D2    -81.52      dBm

                                                                                                                                                      3DB
                         -90




                         -100




                         -110




                         -120



                         -130

                         Center       107.9       MHz                            10   kHz/                                 Span           100   kHz




                  Date: 7.JUL.2017           18:37:57




                                                                                                                                                                       Page 18 of 26

Hotline: 400-6611-140          Tel: 86-755-27673339                                            Fax: 86-755-27673332                                         http://www.tct-lab.com


                                                                         Report No.: TCT170720E003


                   Appendix A: Photographs of Test Setup
                                 Product: FM Transmitter
                                      Model: FMT6
                                   Radiated Emission




                                                                                 Page 19 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT170720E003


                        Appendix B: Photographs of EUT
                           Product: FM Transmitter
                                 Model: FMT6
                               External Photos




                                                                                 Page 20 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT170720E003




                                                                                 Page 21 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT170720E003




                                                                                 Page 22 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT170720E003




                                                                                 Page 23 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT170720E003




                              Product: FM Transmitter
                                   Model: FMT6
                                  Internal Photos




                                                                                 Page 24 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT170720E003




                                                                                 Page 25 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT170720E003




                            *****END OF REPORT*****




                                                                                 Page 26 of 26

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com



Document Created: 2017-08-17 06:05:12
Document Modified: 2017-08-17 06:05:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC