RF_exposure

FCC ID: IKQBT102

RF Exposure Info

Download: PDF
FCCID_4068819

                                     RF exposure evaluation
§2.1093 Radiofrequency radiation exposure evaluation: Portable Devices.

According to§15.247(i) and§1.1307b(1), systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio frequency
energy level in excess of the commission’s guidance.

The 1-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are
determined by:
    [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance,
    mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, where
       f(GHz) is the RF channel transmit frequency in GHz
       Power and distance are rounded to the nearest mW and mm before calculation
       When the minimum test separation distance is < 5 mm, a distance of 5 mm according is applied
        to determine SAR test exclusion.
       The result is rounded to one decimal place for comparison



                                                                Max.
                                                                         Max.
                                                   Tune up      Tune
                                       Frequency                        Tune up
                           Channel                  Power        up
                                        (GHz)                            Power
                                                    (dBm)      Power
                                                                         (mW)
                                                               (dBm)
                            CH 00        2.402      -4.0±1      -3.0      0.50
                            CH 39        2.441      -4.5±1      -3.5      0.45
                            CH 78        2.480      -4.5±1      -3.5      0.45



                                                                                  exclusion
                                                   Max.        Test
                           Frequency     Power                                    thresholds
                 Channel                           Power     distance   Result
                             (GHz)       (dBm)                                     for 1-g
                                                   (mW)       (mm)
                                                                                    SAR
                  CH 00      2.402        -3.0     0.50         5       0.15         3.0



Document Created: 2018-11-12 10:48:06
Document Modified: 2018-11-12 10:48:06

© 2024 FCC.report