RF Exposure Appendix A

FCC ID: IHDT56XS1

RF Exposure Info

Download: PDF
FCCID_4257807

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_750MHz

DUT: D750V3—1012

Communication System: CW; Frequency: 750 MHz;Duty Cycle: 1: 1
Medium: HSL_750_190418 Medium parameters used: £ = 750 MHz; 0 = 0.893 S/m; s, = 40.476; p = 1000
kg/m3
Ambient Temperature : 23.7 °C ; Liquid Temperature : 22.7 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(6.56, 6.56, 6.56) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 2.51 W/kg

Pin=250mW/Zoom Scan (5xSx7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 51.09 V/m; Power Drift =—0.02 dB
Peak SAR (extrapolated) = 2.71 W/kg
SAR(I g) =1.91 W/kg; SAR(10 g) = 1.29 W/kg
Maximum value of SAR (measured) = 2.20 W/kg

        dB
         0


        —1.93


        —3.86


        —5.80


        —7.13


        ass           &
                    0 dB = 2.20 W/kg = 3.42 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_750MHz

DUT: D750V3—1012

Communication System: CW; Frequency: 750 MHz;Duty Cycle: 1: 1
Medium: MSL_750_190419 Medium parameters used: f = 750 MHz; 0 = 0.964 S/m; g, = 55.23; p = 1000
kg/m3
Ambient Temperature : 23.4 °C ; Liquid Temperature : 22.4 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(6.3, 6.3, 6.3) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 2.65 W/kg

Pin=250mW/Zoom Scan (5xSx7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 54.09 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 3.30 W/kg
SAR(I g) = 2.3 W/kg; SAR(10 g) = 1.55 W/kg
Maximum value of SAR (measured) = 2.65 W/kg

        dB
         0


        —1.93


        —3.87


        —5.80


        —7.74


        —9.67         k.
                    0 dB =2.65 W/kg = 4.23 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_835MHz

DUT: D835V2—499

Communication System: CW; Frequency : 835 MHz;Duty Cycle: 1: 1
Medium: HSL_850_190418 Medium parameters used: £ = 835 MHz; 0 = 0.883 S/m; s, = 42.557; p = 1000
kg/m3
Ambient Temperature : 23.7 °C ; Liquid Temperature : 22.7 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(6.39, 6.39, 6.39) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 2.73 W/kg

Pin=250mW/Zoom Scan (5xSx7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 56.15 V/m; Power Drift = 0.17 dB
Peak SAR (extrapolated) = 3.48 W/kg
SAR(1 g) = 2.35 W/kg; SAR(10 g) = 1.55 W/kg
Maximum value of SAR (measured) = 2.73 W/kg

        dB
         0


        —2.08


        —4.16


        —6.23


        —8.31
               w                         &
        a03g   &
             0 dB = 2.73 W/kg = 4.36 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_835MHz

DUT: D835V2—499

Communication System: CW; Frequency : 835 MHz;Duty Cycle: 1: 1
Medium: MSL_850_190419 Medium parameters used: f = 835 MHz; 0 = 0.989 S/m; g, = 56.869; p = 1000
kg/m3
Ambient Temperature : 23.4 °C ; Liquid Temperature : 22.4 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(6.19, 6.19, 6.19) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 2.86 W/kg

Pin=250mW/Zoom Scan (5xSx7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 56.59 V/m; Power Drift =—0.17 dB
Peak SAR (extrapolated) = 3.64 W/kg
SAR(I g) =2.47 W/kg; SAR(10 g) = 1.63 W/kg
Maximum value of SAR (measured) = 2.87 W/kg

        dB
         0


        —2.08


        —4.16


        —6.23


        —8.31
               w                         C
        a03g   &
             0 dB = 2.87 W/kg = 4.58 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_1750MHz

DUT: D1750V2—1068

Communication System: CW; Frequency : 1750 MHz;Duty Cycle: 1:1
Medium: HSL_1750_190418 Medium parameters used: f= 1750 MHz; 0 = 1.402 S/m; g, = 40.688; p = 1000
kg/m3
Ambient Temperature : 23.5 °C ; Liquid Temperature : 22.5 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(5.48, 5.48, 5.48) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 11.9 W/kg

Pin=250mW/Zoom Scan (5xSx7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 93.80 V/m; Power Drift =—0.02 dB
Peak SAR (extrapolated) = 16.6 W/kg
SAR(1 g) = 9.34 W/kg; SAR(10 g) = 4.99 W/kg
Maximum value of SAR (measured) = 11.6 W/ikg

        dB
         0


        —3.52


        —7.04


        10.56


        —14.08


        ars0          &
                    0 dB = 11.6 W/kg = 10.64 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_1750MHz

DUT: D1750V2—1068

Communication System: CW; Frequency : 1750 MHz;Duty Cycle: 1:1
Medium: MSL_1750_190419 Medium parameters used: f = 1750 MHz; 0 = 1.517 S/m; s, = 54.061; p =
1000 kg/m*
Ambient Temperature : 23.7 °C ; Liquid Temperature : 22.7 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(5.06, 5.06, 5.06) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM_RIGHT; Type: QDOOOP40CB; Serial: 1446
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 12.0 W/kg

Pin=250mW/Zoom Scan (5xSx7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 91.12 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 16.5 W/kg
SAR(1 g) = 9.64 W/kg; SAR(10 g) = 5.26 W/kg
Maximum value of SAR (measured) = 11.3 W/kg

        dB
         0


        —3.34


        —6.68


        —10.01


        —13.35


        —16.69        k.
                    0 dB = 11.3 W/kg = 10.53 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_1900MHz

DUT: D1900V2—5d041

Communication System: CW; Frequency : 1900 MHz;Duty Cycle: 1:1
Medium: HSL_1900_190418 Medium parameters used: £= 1900 MHz; 0 = 1.439 S/m; g, = 39.113; p = 1000
kg/m3
Ambient Temperature : 23.5 °C ; Liquid Temperature : 22.5 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(5.27, 5.27, 5.27) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 13.5 W/kg

Pin=250mW/Zoom Scan (5xSx7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 99.09 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 19.8 W/kg
SAR(I g) =10.6 W/kg; SAR(10 g) = 5.39 W/kg
Maximum value of SAR (measured) = 13.5 W/kg

        dB
         0


        —3.77


        —£.54


        11.32


        15.09


        18.8s         0|
                    0 dB = 13.5 W/kg = 11.30 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_1900MHz

DUT: D1900V2—5d041

Communication System: CW; Frequency : 1900 MHz;Duty Cycle: 1:1
Medium: MSL_1900_190419 Medium parameters used: f = 1900 MHz; 0 = 1.571 S/m; s = 52.505; p =
1000 kg/m*
Ambient Temperature : 23.7 °C ; Liquid Temperature : 22.7 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(4.8, 4.8, 4.8) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM_RIGHT; Type: QDOOOP40CB; Serial: 1446
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 13.1 W/kg

Pin=250mW/Zoom Scan (5xSx7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 94.06 V/m; Power Drift =—0.13 dB
Peak SAR (extrapolated) = 18.0 W/kg
SAR(I g) =10.2 W/kg; SAR(10 g) = 5.33 W/kg
Maximum value of SAR (measured) = 12.6 W/kg

        dB
         0


        —3.57


        —7.14


        10.71


        —14.28


        —17.85        k.
                    0 dB = 12.6 W/kg = 11.00 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_2450MHz

DUT: D2450V2—736

Communication System: CW; Frequency : 2450 MHz;Duty Cycle: 1:1
Medium: HSL_2450_190418 Medium parameters used : £= 2450 MHz; 0 = 1.801 S/m; s, = 38.924; p =
1000 kg/m*
Ambient Temperature : 23.6 °C ; Liquid Temperature : 22.6 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(4.69, 4.69, 4.69) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 18.3 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=>mm, dz=5mm
Reference Value = 103.7 V/m; Power Drift =—0.15 dB
Peak SAR (extrapolated) = 28.1 W/kg
SAR(I g) = 13.3 W/kg; SAR(10 g) = 6.11 W/kg
Maximum value of SAR (measured) = 17.3 W/kg

        dB
         0


        —4.75


        —9.50


        —14.26


        —19.01


        —23.76        k.
                    0 dB = 17.3 W/kg = 12.38 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_2450MHz

DUT: D2450V2—736

Communication System: CW ; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: MSL_2450_190419 Medium parameters used : £= 2450 MHz; 0 = 1.994 S/m; g, = 53.145; p =
1000 kg/m*
Ambient Temperature : 23.7 °C ; Liquid Temperature : 22.7 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN7306; ConvF(7.75, 7.75, 7.75) ; Calibrated: 2018/7/26
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE3 $n495; Calibrated: 2018/5/24
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 20.1 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=>mm, dz=5mm
Reference Value = 101.2 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 24.9 W/kg
SAR(I g) =12.4 W/kg; SAR(10 g) = 5.75 W/kg
Maximum value of SAR (measured) = 20.4 W/kg

        dB
         0


        —5.00


        —10.00


        —15.00


        —20.00


        —25.00        k.
                    0 dB = 20.4 W/kg = 13.10 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_2600MHz

DUT: D2600V2—1008

Communication System: CW; Frequency : 2600 MHz;Duty Cycle: 1:1
Medium: HSL_2600_190418 Medium parameters used: £= 2600 MHz; 0 = 1.971 S/m; g, = 38.337; p = 1000
kg/m3
Ambient Temperature : 23.6 °C ; Liquid Temperature : 22.6 °C

DASY5S Configuration:
— Probe: ES3DV3 — SN3169; ConvF(4.5, 4.5, 4.5) ; Calibrated: 2018/5/28
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1326; Calibrated: 2018/9/18
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 17.9 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=>mm, dz=5mm
Reference Value = 97.71 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 28.8 W/kg
SAR(I g) =13.4 W/kg; SAR(10 g) = 6.02 W/kg
Maximum value of SAR (measured) = 17.9 W/kg

        dB
         0


        —4.65


        —9.29


        —13.94


        —18.58


        —23.23        .
                    0 dB = 17.9 W/kg = 12.53 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_2600MHz

DUT: D2600V2—1008

Communication System: CW; Frequency : 2600 MHz;Duty Cycle: 1:1
Medium: MSL_2600_190419 Medium parameters used: f = 2600 MHz; 0 = 2.195 S/m; &, = 52.645; p =
1000 kg/m*
Ambient Temperature : 23.7 °C ; Liquid Temperature : 22.7 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN7306; ConvF(7.47, 7.47, 7.47) ; Calibrated: 2018/7/26
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE3 $n495; Calibrated: 2018/5/24
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 23.1 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=>mm, dz=5mm
Reference Value = 8§4.43 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 29.1 W/kg
SAR(I g) =13.9 W/kg; SAR(10 g) = 6.22 W/kg
Maximum value of SAR (measured) = 23.7 W/kg

        dB
         0


        —6.00


        —12.00


        —18.00


        —24.00


        —30.00        k.
                    0 dB = 23.7 W/kg = 13.75 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_5250MHz

DUT: DSGHzV2—1006

Communication System: CW; Frequency : 5250 MHz;Duty Cycle: 1:1
Medium: HSL_5G_190418 Medium parameters used : f= 5250 MHz; 0 = 4.721 S/m; &, = 36.625; p = 1000
kg/m3
Ambient Temperature : 23.6 °C ; Liquid Temperature : 22.6 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(5.12, 5.12, 5.12) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 S$n1399; Calibrated: 2018/11/16
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 20.4 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 69.45 V/m; Power Drift =—0.05 dB
Peak SAR (extrapolated) = 30.7 W/kg
SAR(I g) =7.95 W/kg; SAR(10 g) = 2.24 W/kg
Maximum value of SAR (measured) = 18.7 W/kg

        dB
         0


        —6.86


        —13.72


        —20.59


        —27.45


        —34.31        .
                    0 dB = 18.7 W/kg = 12.72 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_5250MHz

DUT: DSGHzV2—1006

Communication System: CW; Frequency : 5250 MHz;Duty Cycle: 1:1
Medium: MSL_5G_190419 Medium parameters used : £f= 5250 MHz; 0 = 5.361 S/m; g, = 48.304; p = 1000
kg/m3
Ambient Temperature ! 23.8 °C ; Liquid Temperature : 22.8 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.4, 4.4, 4.4) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 S$n1399; Calibrated: 2018/11/16
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 18.4 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.32 V/m; Power Drift =—0.09 dB
Peak SAR (extrapolated) = 32.0 W/kg
SAR(I g) =7.75 W/kg; SAR(10 g) = 2.17 W/kg
Maximum value of SAR (measured) = 19.9 W/kg

        dB
         0


        —6.00


        —12.00


        —18.00


        —24.00


        —30.00        .
                    0 dB = 19.9 W/kg = 12.99 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_5600MHz

DUT: DSGHzV2—1006

Communication System: CW; Frequency : 5600 MHz;Duty Cycle: 1:1
Medium: HSL_5G_190418 Medium parameters used: £ = 5600 MHz; 0 = 5.083 S/m; g, = 36.149; p = 1000
kg/m3
Ambient Temperature : 23.6 °C ; Liquid Temperature : 22.6 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.47, 4.47, 4.47) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 S$n1399; Calibrated: 2018/11/16
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 21.8 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 72.28 V/m; Power Drift = 0.15 dB
Peak SAR (extrapolated) = 36.5 W/kg
SAR(I g) =8.75 W/kg; SAR(10 g) = 2.47 W/kg
Maximum value of SAR (measured) = 21.6 W/kg

        dB
         0


        —6.92


        —13.84


        —20.77


        —27.69


        —34.61        k.
                    0 dB = 21.6 W/kg = 13.34 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_5600MHz

DUT: DSGHzV2—1006

Communication System: CW; Frequency : 5600 MHz;Duty Cycle: 1:1
Medium: MSL_5G_190419 Medium parameters used: f = 5600 MHz; 0 = 5.819 S/m; g, = 47.641; p = 1000
kg/m3
Ambient Temperature ! 23.8 °C ; Liquid Temperature : 22.8 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(3.82, 3.82, 3.82) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 S$n1399; Calibrated: 2018/11/16
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 20.8 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 69.24 V/m; Power Drift =—0.1 dB
Peak SAR (extrapolated) = 37.6 W/kg
SAR(1 g) =8.28 W/kg; SAR(10 g) = 2.28 W/kg
Maximum value of SAR (measured) = 21.9 W/kg

        dB
         0


        —6.00


        —12.00


        —18.00


        —24.00


        s0.00         |
                    0 dB =21.9 W/kg = 13.40 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/18


System Check_Head_5750MHz

DUT: DSGHzV2—1006

Communication System: CW ; Frequency: 5750 MHz;Duty Cycle: 1:1
Medium: HSL_5G_190418 Medium parameters used: £ = 5750 MHz; 0 = 5.246 S/m; s, = 35.932; p = 1000
kg/m3
Ambient Temperature : 23.6 °C ; Liquid Temperature : 22.6 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.72, 4.72, 4.72) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 S$n1399; Calibrated: 2018/11/16
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 21.1 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.74 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 35.3 W/kg
SAR(1 g) =8.22 W/kg; SAR(10 g) = 2.26 W/kg
Maximum value of SAR (measured) = 20.8 W/kg

        dB
         0


        —6.21


        12.42


        —18.64


        —24.85


        —31.06        .
                    0 dB = 20.8 W/kg = 13.18 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/19


System Check_Body_5750MHz

DUT: DSGHzV2—1006

Communication System: CW; Frequency : 5750 MHz;Duty Cycle: 1:1
Medium: MSL_5G_190419 Medium parameters used: f = 5750 MHz; 0 = 6.047 S/m; g, = 47.428; p = 1000
kg/m3
Ambient Temperature ! 23.8 °C ; Liquid Temperature : 22.8 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.11, 4.11, 4.11) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 S$n1399; Calibrated: 2018/11/16
— Phantom: SAM LEFT; Type: QDO0O0P40CD; Serial: TP:1718
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 18.7 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 65.38 V/m; Power Drift =—0.17 dB
Peak SAR (extrapolated) = 34.9 W/kg
SAR(I g) =7.39 W/kg; SAR(10 g) = 2.06 W/kg
Maximum value of SAR (measured) = 19.8 W/kg

        dB
         0


        —6.60


        —13.20


        —19.80


        —26.40


        —33.00        .
                    0 dB = 19.8 W/kg = 12.97 dBW/kg



Document Created: 2019-05-22 08:39:18
Document Modified: 2019-05-22 08:39:18