Test Report HAC RF Appendix B

FCC ID: IHDT56XS1

Test Report

Download: PDF
FCCID_4204861

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#01_HAC_E_GSM850_GSM Voice_Ch128


Communication System: GSM-FDD (TDMA, GMSK); Frequency: 824.2 MHz;Duty Cycle: 1:8.6896
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 824.2 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 33.03 V/m; Power Drift = 0.00 dB
Applied MIF = 3.63 dB
RF audio interference level = 32.21 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     30.28 dBV/m        31.72 dBV/m    31.57 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     30.8 dBV/m         32.05 dBV/m    31.87 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     31.57 dBV/m        32.21 dBV/m    31.89 dBV/m
                                                         Cursor:
                                                   Total = 32.21 dBV/m
                                                     E Category: M4
                                                  Location: -1, 25, 8.7 mm




                     0 dB = 40.80 V/m = 32.21 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#02_HAC_E_GSM850_GSM Voice_Ch189


Communication System: GSM-FDD (TDMA, GMSK); Frequency: 836.4 MHz;Duty Cycle: 1:8.6896
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 836.4 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 42.33 V/m; Power Drift = -0.07 dB
Applied MIF = 3.63 dB
RF audio interference level = 34.63 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     32.21 dBV/m        33.8 dBV/m     33.69 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     33.01 dBV/m        34.28 dBV/m    34.12 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     34.01 dBV/m        34.63 dBV/m    34.27 dBV/m
                                                         Cursor:
                                                   Total = 34.63 dBV/m
                                                     E Category: M4
                                                  Location: -2, 25, 8.7 mm




                     0 dB = 53.87 V/m = 34.63 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#03_HAC_E_GSM850_GSM Voice_Ch251


Communication System: GSM-FDD (TDMA, GMSK); Frequency: 848.8 MHz;Duty Cycle: 1:8.6896
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 848.8 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 23.43 V/m; Power Drift = -0.02 dB
Applied MIF = 3.63 dB
RF audio interference level = 29.68 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     26.85 dBV/m        28.89 dBV/m    28.73 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     27.7 dBV/m         29.32 dBV/m    29.21 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     28.77 dBV/m        29.68 dBV/m    29.61 dBV/m
                                                         Cursor:
                                                   Total = 29.68 dBV/m
                                                     E Category: M4
                                                  Location: -1, 25, 8.7 mm




                     0 dB = 30.47 V/m = 29.68 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#04_HAC_E_GSM1900_GSM Voice_Ch512


Communication System: GSM-FDD (TDMA, GMSK); Frequency: 1850.2 MHz;Duty Cycle: 1:8.6896
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 1850.2 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 5.927 V/m; Power Drift = -0.06 dB
Applied MIF = 3.63 dB
RF audio interference level = 24.24 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4     Grid 3 M4
                                     23.48 dBV/m        24.24 dBV/m   23.9 dBV/m
                                     Grid 4 M4          Grid 5 M4     Grid 6 M4
                                     19.27 dBV/m        21.15 dBV/m   21.22 dBV/m
                                     Grid 7 M4          Grid 8 M4     Grid 9 M4
                                     22.61 dBV/m        23.75 dBV/m   23.67 dBV/m
                                                         Cursor:
                                                  Total = 24.24 dBV/m
                                                     E Category: M4
                                                Location: -0.5, -25, 8.7 mm




                     0 dB = 16.30 V/m = 24.24 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#05_HAC_E_GSM1900_GSM Voice_Ch661


Communication System: GSM-FDD (TDMA, GMSK); Frequency: 1880 MHz;Duty Cycle: 1:8.6896
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 6.370 V/m; Power Drift = -0.05 dB
Applied MIF = 3.63 dB
RF audio interference level = 24.69 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     24.23 dBV/m        24.69 dBV/m    24.16 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     20.17 dBV/m        20.68 dBV/m    20.77 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     22.47 dBV/m        23.56 dBV/m    23.45 dBV/m
                                                         Cursor:
                                                   Total = 24.69 dBV/m
                                                     E Category: M4
                                                  Location: 4, -25, 8.7 mm




                     0 dB = 17.17 V/m = 24.70 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#06_HAC_E_GSM1900_GSM Voice_Ch810


Communication System: GSM-FDD (TDMA, GMSK); Frequency: 1909.8 MHz;Duty Cycle: 1:8.6896
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 1909.8 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 7.798 V/m; Power Drift = 0.15 dB
Applied MIF = 3.63 dB
RF audio interference level = 27.35 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     26.87 dBV/m        27.35 dBV/m    26.57 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     22.85 dBV/m        23.82 dBV/m    23.86 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     23.98 dBV/m        24.8 dBV/m     24.72 dBV/m
                                                         Cursor:
                                                   Total = 27.35 dBV/m
                                                      E Category: M4
                                                 Location: 2.5, -25, 8.7 mm




                     0 dB = 23.32 V/m = 27.35 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#07_HAC_E_CDMA BC0_1xRTT RC1 SO3_Ch1013


Communication System: CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 824.7 MHz;Duty Cycle:
1:17.7419
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 824.7 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 17.93 V/m; Power Drift = -0.03 dB
Applied MIF = 3.26 dB
RF audio interference level = 26.49 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     23.61 dBV/m        26.18 dBV/m    26.18 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     24.31 dBV/m        26.45 dBV/m    26.43 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     25.37 dBV/m        26.49 dBV/m    26.45 dBV/m
                                                         Cursor:
                                                   Total = 26.49 dBV/m
                                                     E Category: M4
                                                  Location: -2, 25, 8.7 mm




                     0 dB = 21.11 V/m = 26.49 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#08_HAC_E_CDMA BC0_1xRTT RC1 SO3_Ch384


Communication System: CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 836.52 MHz;Duty Cycle:
1:17.7419
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 836.52 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 16.67 V/m; Power Drift = -0.05 dB
Applied MIF = 3.26 dB
RF audio interference level = 25.87 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     22.34 dBV/m        25.46 dBV/m    25.46 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     23.19 dBV/m        25.73 dBV/m    25.71 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     24.51 dBV/m        25.87 dBV/m    25.77 dBV/m
                                                         Cursor:
                                                   Total = 25.87 dBV/m
                                                      E Category: M4
                                                 Location: -5.5, 21, 8.7 mm




                     0 dB = 19.65 V/m = 25.87 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#09_HAC_E_CDMA BC0_1xRTT RC1 SO3_Ch777


Communication System: CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 848.31 MHz;Duty Cycle:
1:17.7419
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 848.31 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 16.55 V/m; Power Drift = -0.16 dB
Applied MIF = 3.26 dB
RF audio interference level = 26.05 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     21.51 dBV/m        25.45 dBV/m    25.5 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     22.84 dBV/m        25.88 dBV/m    25.9 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     24.39 dBV/m        26.05 dBV/m    25.98 dBV/m
                                                         Cursor:
                                                   Total = 26.05 dBV/m
                                                      E Category: M4
                                                 Location: -6, 20.5, 8.7 mm




                     0 dB = 20.07 V/m = 26.05 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#10_HAC_E_CDMA BC1_1xRTT RC1 SO3_Ch25


Communication System: CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1851.25 MHz;Duty Cycle:
1:17.7419
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 1851.25 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 4.997 V/m; Power Drift = -0.08 dB
Applied MIF = 3.26 dB
RF audio interference level = 22.72 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     20.23 dBV/m        20.79 dBV/m    20.47 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     17.66 dBV/m        18.47 dBV/m    18.14 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     19.47 dBV/m        22.72 dBV/m    21.31 dBV/m
                                                         Cursor:
                                                   Total = 22.72 dBV/m
                                                     E Category: M4
                                                  Location: -5, 25, 8.7 mm




                     0 dB = 13.68 V/m = 22.72 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#11_HAC_E_CDMA BC1_1xRTT RC1 SO3_Ch600


Communication System: CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1880 MHz;Duty Cycle:
1:17.7419
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 5.234 V/m; Power Drift = -0.12 dB
Applied MIF = 3.26 dB
RF audio interference level = 21.80 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     21.17 dBV/m        21.8 dBV/m     20.97 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     18.11 dBV/m        18.5 dBV/m     18.54 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     20.2 dBV/m         20.54 dBV/m    20.27 dBV/m
                                                         Cursor:
                                                   Total = 21.80 dBV/m
                                                     E Category: M4
                                                  Location: 4, -25, 8.7 mm




                     0 dB = 12.30 V/m = 21.80 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#12_HAC_E_CDMA BC1_1xRTT RC1 SO3_Ch1175


Communication System: CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1908.75 MHz;Duty Cycle:
1:17.7419
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 1908.75 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 5.373 V/m; Power Drift = -0.06 dB
Applied MIF = 3.26 dB
RF audio interference level = 22.79 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4          Grid 2 M4      Grid 3 M4
                                     22.16 dBV/m        22.79 dBV/m    22.02 dBV/m
                                     Grid 4 M4          Grid 5 M4      Grid 6 M4
                                     18.78 dBV/m        19.89 dBV/m    19.93 dBV/m
                                     Grid 7 M4          Grid 8 M4      Grid 9 M4
                                     20.34 dBV/m        20.97 dBV/m    20.55 dBV/m
                                                         Cursor:
                                                   Total = 22.79 dBV/m
                                                      E Category: M4
                                                 Location: 3.5, -25, 8.7 mm




                     0 dB = 13.79 V/m = 22.79 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#13_HAC_E_WLAN2.4GHz_802.11g 6Mbps_Ch1


Communication System: IEEE 802.11g WiFi 2.4 GHz (DSSS/OFDM, 54 Mbps); Frequency: 2412 MHz;Duty
Cycle: 1:12.5893
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 2412 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 18.90 V/m; Power Drift = -0.06 dB
Applied MIF = 0.12 dB
RF audio interference level = 26.61 dBV/m
Emission category: M4

                                     MIF scaled E-field
                                     Grid 1 M4           Grid 2 M4     Grid 3 M4
                                     20.15 dBV/m 20.21 dBV/m 19.88 dBV/m
                                     Grid 4 M4           Grid 5 M4     Grid 6 M4
                                     23.76 dBV/m 23.68 dBV/m 21.7 dBV/m
                                     Grid 7 M4           Grid 8 M4     Grid 9 M4
                                     26.58 dBV/m 26.61 dBV/m 23.53 dBV/m
                                                          Cursor:
                                                    Total = 26.61 dBV/m
                                                      E Category: M4
                                                   Location: 7, 25, 8.7 mm




                      0 dB = 21.40 V/m = 26.61 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#14_HAC_E_WLAN2.4GHz_802.11g 6Mbps_Ch6


Communication System: IEEE 802.11g WiFi 2.4 GHz (DSSS/OFDM, 54 Mbps); Frequency: 2437 MHz;Duty
Cycle: 1:12.5893
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 2437 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 19.38 V/m; Power Drift = -0.00 dB
Applied MIF = 0.12 dB
RF audio interference level = 27.51 dBV/m
Emission category: M4

                                     MIF scaled E-field
                                     Grid 1 M4           Grid 2 M4     Grid 3 M4
                                     20.54 dBV/m         21.08 dBV/m   20.94 dBV/m
                                     Grid 4 M4           Grid 5 M4     Grid 6 M4
                                     24.45 dBV/m         24.42 dBV/m   22.5 dBV/m
                                     Grid 7 M4           Grid 8 M4     Grid 9 M4
                                     27.47 dBV/m         27.51 dBV/m   24.62 dBV/m
                                                          Cursor:
                                                    Total = 27.51 dBV/m
                                                      E Category: M4
                                                  Location: 6.5, 25, 8.7 mm




                      0 dB = 23.74 V/m = 27.51 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2019/1/16


#15_HAC_E_WLAN2.4GHz_802.11g 6Mbps_Ch11


Communication System: IEEE 802.11g WiFi 2.4 GHz (DSSS/OFDM, 54 Mbps); Frequency: 2462 MHz;Duty
Cycle: 1:12.5893
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 2462 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - ER3D: 15 mm from Probe Center to the Device/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 15.88 V/m; Power Drift = 0.04 dB
Applied MIF = 0.12 dB
RF audio interference level = 25.55 dBV/m
Emission category: M4

                                     MIF scaled E-field
                                     Grid 1 M4           Grid 2 M4     Grid 3 M4
                                     18.57 dBV/m 18.99 dBV/m 18.57 dBV/m
                                     Grid 4 M4           Grid 5 M4     Grid 6 M4
                                     22.78 dBV/m 22.78 dBV/m 20.87 dBV/m
                                     Grid 7 M4           Grid 8 M4     Grid 9 M4
                                     25.48 dBV/m 25.55 dBV/m 22.61 dBV/m
                                                          Cursor:
                                                    Total = 25.55 dBV/m
                                                      E Category: M4
                                                  Location: 6.5, 25, 8.7 mm




                      0 dB = 18.96 V/m = 25.56 dBV/m



Document Created: 2019-03-11 13:54:20
Document Modified: 2019-03-11 13:54:20

© 2024 FCC.report