Test Report HAC RF Appendix A

FCC ID: IHDT56XS1

Test Report

Download: PDF
FCCID_4204853

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2019/1/16


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 835 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 123.1 V/m; Power Drift = -0.02 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 109.1 V/m
Average value of Total=(109.0+109.1) / 2 = 109.05 V/m


                                          PMF scaled E-field
                                           Grid 1 M4 Grid 2 M4 Grid 3 M4
                                           106.2 V/m      109.0 V/m   107.3 V/m
                                           Grid 4 M4      Grid 5 M4   Grid 6 M4
                                           61.02 V/m      62.42 V/m   61.65 V/m
                                           Grid 7 M4      Grid 8 M4   Grid 9 M4
                                           107.1 V/m      109.1 V/m   107.1 V/m
                                                         Cursor:
                                                    Total = 109.1 V/m
                                                     E Category: M4
                                                 Location: 0, 72.5, 9.7 mm




                     0 dB = 109.1 V/m = 40.76 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2019/1/16


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 141.6 V/m; Power Drift = 0.03 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 89.12 V/m
Average value of Total=(86.72+89.12) / 2 = 87.92 V/m

                                          PMF scaled E-field
                                           Grid 1 M3 Grid 2 M3 Grid 3 M3
                                           86.01 V/m      86.72 V/m   84.45 V/m
                                           Grid 4 M3      Grid 5 M3   Grid 6 M3
                                           70.48 V/m      71.63 V/m   70.89 V/m
                                           Grid 7 M3      Grid 8 M3   Grid 9 M3
                                           87.61 V/m      89.12 V/m   87.22 V/m
                                                         Cursor:
                                                    Total = 89.12 V/m
                                                     E Category: M3
                                                  Location: 0, 33, 9.7 mm




                     0 dB = 89.12 V/m = 39.00 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2019/1/16


HAC_E_Dipole_2450
DUT: HAC Dipole 2450 MHz

Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2480; ConvF(1, 1, 1) @ 2450 MHz; Calibrated: 2018/12/10
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD2450 = 10mm & 15mm
2/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm,
dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 82.48 V/m; Power Drift = 0.02 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 92.85 V/m
Average value of Total=(91.78+92.85) / 2 = 92.315 V/m

                                          PMF scaled E-field
                                           Grid 1 M3 Grid 2 M3 Grid 3 M3
                                           90.81 V/m      91.78 V/m   88.33 V/m
                                           Grid 4 M3      Grid 5 M3   Grid 6 M3
                                           80.32 V/m      80.98 V/m   78.48 V/m
                                           Grid 7 M3      Grid 8 M3   Grid 9 M3
                                           91.73 V/m      92.85 V/m   89.91 V/m
                                                         Cursor:
                                                    Total = 92.85 V/m
                                                     E Category: M3
                                                Location: 0.5, 24.5, 8.7 mm




                     0 dB = 92.85 V/m = 39.36 dBV/m