Test Report HAC RF Appendix A

FCC ID: IHDT56XR4

Test Report

Download: PDF
FCCID_4262129

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/3/6


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 835 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 131.1 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 114.1 V/m
Average value of Total=(114.1+112.2) / 2 = 113.15 V/m

                                               PMF scaled E-field
                                                Grid 1 M4 Grid 2 M4 Grid 3 M4
                                                113.5 V/m         114.1 V/m   108.9 V/m
                                                Grid 4 M4         Grid 5 M4   Grid 6 M4
                                                62.47 V/m         63.05 V/m   60.22 V/m
                                                Grid 7 M4         Grid 8 M4   Grid 9 M4
                                                112.1 V/m         112.2 V/m   108.4 V/m
                                                              Cursor:
                                                         Total = 114.1 V/m
                                                          E Category: M4
                                                       Location: 3, -72, 9.7 mm




                          0 dB = 114.1 V/m = 41.15 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/3/28


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 835 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 124.7 V/m; Power Drift = -0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 110.0 V/m
Average value of Total=(110+106.9) / 2 = 108.45 V/m

                                               PMF scaled E-field
                                                Grid 1 M4 Grid 2 M4 Grid 3 M4
                                                109.1 V/m         110.0 V/m   105.6 V/m
                                                Grid 4 M4         Grid 5 M4   Grid 6 M4
                                                60.26 V/m         60.47 V/m   58.12 V/m
                                                Grid 7 M4         Grid 8 M4   Grid 9 M4
                                                106.3 V/m         106.9 V/m   102.4 V/m
                                                              Cursor:
                                                         Total = 110.0 V/m
                                                          E Category: M4
                                                       Location: 1, -73, 9.7 mm




                          0 dB = 110.0 V/m = 40.83 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab             Date: 2019/3/6


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: 0 = 0 S/m, s, = 1; p =0 kg/m>
Ambient Temperature : 23.5 °C

DASYS5 Configuration:
— Probe: EF3DV3 — SN4047; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2019/1/30
— Sensor—Surface: (Fix Surface)
— Electronics: DAF4 Sn854; Calibrated: 2018/6/14
— Phantom: HAC Test Arch with AMCC; Type: SD HAC POI BA;
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan — measurement distance from the probe sensor center to CD1880 =10mm & 15mm/Hearing
Aid Compatibility Test at 1 5mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 162.8 V/m; Power Drift = 0.03 dB
PMR not calibrated. PMF = 1.000 is applied.
E—field emissions = 91.33 V/m
Average value of Total=(91.33+90.07) / 2 = 90.7 V/m

                                               PMF scaled E—field

                                                Grid 1 M3         Grid 2 M3     Grid 3 M3
                                                91.12 V/m 91.33 V/m 87.73 V/im
                                                Grid 4 M3         Grid 5 M3     Grid 6 M3
                                                67.52 V/m 67.62 V/m 66.33 V/m
                                                Grid 7 M3         Grid 8 M3     Grid 9 M3
                                                89.32 V/m 90.07 V/m 87.84 V/im
                                                                  Cursor:
                                                          Total =91.33 V/m
                                                           E Category: M3
                                                      Location: 1.5, —33, 9.7 mm




               —0.86


               —1.73


               —2.59


               —3416


               —4.32
                           —
                          0 dB =91.33 V/m =39.21 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/3/28


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 159.1 V/m; Power Drift = 0.02 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 88.21 V/m
Average value of Total=(87.61+88.21) / 2 = 87.91 V/m

                                               PMF scaled E-field
                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                87.04 V/m         87.61 V/m   84.52 V/m
                                                Grid 4 M3         Grid 5 M3   Grid 6 M3
                                                65.21 V/m         65.27 V/m   63.76 V/m
                                                Grid 7 M3         Grid 8 M3   Grid 9 M3
                                                87.62 V/m         88.21 V/m   84.83 V/m
                                                              Cursor:
                                                         Total = 88.21 V/m
                                                          E Category: M3
                                                      Location: 1, 33.5, 9.7 mm




                          0 dB = 88.21 V/m = 38.91 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2019/3/6


HAC_E_Dipole_2450
DUT: HAC Dipole 2450 MHz

Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 2450 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD2450 = 10mm & 15mm
2/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm,
dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 82.44 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 92.63 V/m
Average value of Total=(91.23+92.63) / 2 = 91.93 V/m

                                               PMF scaled E-field
                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                90.55 V/m 91.23 V/m 89.03 V/m
                                                Grid 4 M3 Grid 5 M3 Grid 6 M3
                                                80.51 V/m 80.85 V/m 78.81 V/m
                                                Grid 7 M3 Grid 8 M3 Grid 9 M3
                                                91.57 V/m 92.63 V/m 90.24 V/m
                                                              Cursor:
                                                         Total = 92.63 V/m
                                                          E Category: M3
                                                     Location: 0.5, 24.5, 8.7 mm




                          0 dB = 92.63 V/m = 39.34 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab             Date: 2019/3/6


HAC_E_Dipole_2600
DUT: HAC Dipole 2600 MHz

Communication System: CW ; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: 0 = 0 S/m, s, = 1; p =0 kg/m>
Ambient Temperature : 23.5 °C

DASYS5 Configuration:
— Probe: EF3DV3 — SN4047; ConvF(1, 1, 1) @ 2600 MHz; Calibrated: 2019/1/30
— Sensor—Surface: (Fix Surface)
— Electronics: DAF4 Sn854; Calibrated: 2018/6/14
— Phantom: HAC Test Arch with AMCC; Type: SD HAC POI BA;
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan — measurement distance from the probe sensor center to CD2600 =10mm & 15mm/Hearing
Aid Compatibility Test at 1 5mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 74.04 V/m; Power Drift = —0.03 dB
PMR not calibrated. PMF = 1.000 is applied.
E—field emissions = 89.47 V/m
Average value of Total=(89.23+89.47) / 2 = 89.35 V/m

                                               PMF scaled E—field

                                                Grid 1 M3         Grid 2 M3     Grid 3 M3
                                                88.51 V/m 89.23 V/m 86.41 V/im
                                                Grid 4 M3         Grid 5 M3     Grid 6 M3
                                                82.56 V/m 83.01 V/m 81.01 V/m
                                                Grid 7 M3         Grid 8 M3     Grid 9 M3
                                                88.73 V/m 89.47 V/im 86.55 V/im
                                                                  Cursor:
                                                           Total = 89.47 V/m
                                                            E Category: M3
                                                       Location: 1, 23.5, 9.7 mm




               —1.44


               —2.08


               —4.32


               —5.76


               —£.20
                           —
                          0 dB = 89.47 V/m =39.03 dBV/m



Document Created: 2019-05-15 22:03:40
Document Modified: 2019-05-15 22:03:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC