XT1952-T RF Exposure Report Appendix A

FCC ID: IHDT56XR4

RF Exposure Info

Download: PDF
FCCID_4262023

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.19

System Check_Head_750MHz

DUT: D750V3 — SN:1099

Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1
Medium: HSL_750 Medium parameters used: £= 750 MHz; 0 =0.899 S/m; s = 41.116; p= 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.7 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(9.92, 9.92, 9.92); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =2.72 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=Smm
Reference Value= 49.46 V/m; Power Drift=0.05 dB
Peak SAR (extrapolated) = 3.23 W/kg
SAR(1 g) = 2.18 W/kg; SAR(1O g) = 1.46 W/kg
Maximum value of SAR (measured) =2.75 W/kg




      —2.01


      —4.02


      —6.03


      —8.04


      —10.05
               0 dB =2.75 Wikg = 4.39 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.21

System Check_Head_835MHz

DUT: D835V2 — SN:4d162

Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1
Medium: HSL_835 Medium parameters used: £= 835 MHz; 0 =0.914 S/m; s = 40.996; p= 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.9 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(®.51, 9.51, 9.51); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =3.04 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=Smm
Reference Value= 52.23 V/m; Power Drift =0.05 dB
Peak SAR (extrapolated) =3.63 W/kg
SAR(1 g) = 2.4 W/kg; SAR(1O g) = 1.55 W/kg
Maximum value of SAR (measured) =3.07 W/kg

     dB
     0


      —2.23


      —4.47


      —6.70


      —8.94                   /

      11.17
               0 dB =3.07 Wikg = 4.87 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.22

System Check_Head_1750MHz

DUT: D1750V2 — SN:1137

Communication System: UID 0, CW; Frequency: 1750 MHz;Duty Cycle: 1:1
Medium: HSL_1750 Medium parameters used: £=1750 MHz; 0 = 1.352 $/m; & = 40.502; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.9 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(8.29, 8.29, 8.29); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 12.5 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=Smm
Reference Value=79.89 V/m; Power Drift =0.16 dB
Peak SAR (extrapolated) = 15.9 W/kg
SAR(1 g) = 8.9 W/kg; SAR(1O g) = 4.76 W/kg
Maximum value of SAR (measured) = 12.5 W/kg

     dB
     0


      —3.49


      —6.98


      —10.46


      13.95


      17.44
               0 dB = 12.5 W/kg =10.97 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.20

System Check_Head_1900MHz

DUT: D1900V2 — SN: 50182

Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: HSL_1900 Medium parameters used: £= 1900 MHz; 0 = 1.404 $/m; & = 40.048; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.7 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(8.04, 8.04, 8.04); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 15.6 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=Smm
Reference Value=2.853 V/m; Power Drift =0.08 dB
Peak SAR (extrapolated) = 18.6 Wkg
SAR(1 g) = 10.6 W/kg; SAR(1O g) = 5.48 W/kg
Maximum value of SAR (measured) =14.9 W/kg

     dB
     0


      —3.40


      —6.97


      —10.45


      13.94


      "17.42
               0 dB = 14.9 Wikg=11.73 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.21

System Check_Head_2450MHz

DUT: D2450V2 — SN:736

Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: HSL_2450 Medium parameters used: £=2450 MHz; 0 = 1.873 $/m; s = 38.3; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.6 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(7.56, 7.56, 7.56); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (71x71x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) =23.0 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=Smm, daz=Smm
Reference Value=93.68 V/m; Power Drift =—0.06 dB
Peak SAR (extrapolated) =31.0 W/kg
SAR(1 g) = 13.4 W/kg; SAR(1O g) = 6.71 W/kg
Maximum value of SAR (measured) =22.7 W/kg

     dB
     0


      ~4.54


      —9.08


      13.63


      —18.17


      —22.01
               0 dB =22.7 Wikg =13.56 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.20

System Check_Head_2600MHz

DUT: D2600V2 — SN:1061

Communication System: UID 0, CW; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: HSL_2600 Medium parameters used: £=2600 MHz; 0 =2.034 $/m; s = 38.307; p = 1000
kg/m3
Ambient Temperature : 23.4 °C; Liquid Temperature : 22.8 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(7.44, 7.44, 7.44); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (71x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) =21.8 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=Smm, daz=Smm
Reference Value=98.66 V/m; Power Drift =0.09 dB
Peak SAR (extrapolated) = 31.3 Wkg
SAR(1 g) = 14.2 W/kg; SAR(1O g) = 6.2 W/kg
Maximum value of SAR (measured) = 22.3 W/kg

     dB
     0


      —5.21


      —10.42


      15.62


      —20.83


      —26.04
               0 dB = 22.3 Wikg =13.48 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.21

System Check_Head_5250MHz

DUT: DSGHzV2—SN:1006

Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1
Medium: HSL_5000 Medium parameters used: £=5250 MHz; 0 = 4.731 $/m; & = 37.474; p = 1000
kg/m3
Ambient Temperature : 23.4 °C; Liquid Temperature : 22.9 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(5.2, 5.2, 5.2); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 20.3 W/kg

Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value=42.05 V/m; Power Drift =0.02 dB
Peak SAR (extrapolated) = 35.4 W/kg
SAR(1 g) = 8.21 W/kg; SAR(1O g) = 2.33 W/kg
Maximum value of SAR (measured) = 19.8 W/kg

     dB
     0


      —7.60


      15.20


      —22.00


      —30.40


      —38.00
               0 dB = 19.8 W/kg =12.97 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.22

System Check_Head_S600MHz

DUT: DSGHzV2—SN:1006

Communication System: UID 0, CW (0); Frequency: 5600 MHz;Duty Cycle: 1:1
Medium: HSL_5000 Medium parameters used: £= 5600 MHz; 0 = 5.088 S$/m; £,= 36.99; p= 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.6 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(4.94, 4.94, 4.94); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) =20.1 W/kg

Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value=40.15 V/m; Power Drift =0.03 dB
Peak SAR (extrapolated) = 34.9 W/kg
SAR(1 g) = 8 W/kg; SAR(10 g) = 2.26 W/kg
Maximum value of SAR (measured) = 19.8 W/kg

     dB
     0


      —7.60


      15.20


      —22.00


      —30.40


      —38.00
               0 dB = 19.8 W/kg =12.97 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.22

System Check_Head_5750MHz

DUT: DSGHzV2—SN:1006

Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1
Medium: HSL_5000 Medium parameters used: £=5750 MHz; 0 = 5.248 S$/m; s = 36.784; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.7 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(5.23, 5.23, 5.23); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 18.2 W/kg

Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value=38.69 V/m; Power Drift =0.02 dB
Peak SAR (extrapolated) = 34.5 W/kg
SAR(1 g) = 7.55 W/kg; SAR(1O g) = 2.13 W/kg
Maximum value of SAR (measured) = 18.7 W/kg

     dB
     0


      —7.00


      14.00


      —21.00


      —28.00


      —35.00
               0 dB = 18.7 W/kg =12.72 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.22

System Check_Body_750MHz

DUT: D750V3 — SN:1099

Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1
Medium: MSL_750 Medium parameters used: {= 750 MHz; 0 = 0.964 S/m; & = 56.433; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.6 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(®.7, 9.7, 9.7); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =2.94 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=Smm
Reference Value= 50.69 V/m; Power Drift=0.01 dB
Peak SAR (extrapolated) = 3.47 W/kg
SAR(1 g) = 2.30 W/kg; SAR(1O g) = 1.51 W/kg
Maximum value of SAR (measured) =2.94 W/kg

     dB
     0


      —1.98


      —3.97


      —5.95                                            ‘


      —7.94                          /

      —0.92
               0 dB =2.94 Wikg = 4.68 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.19

System Check_Body_835MHz

DUT: D835V2 — SN:4d162

Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1
Medium: MSL_850 Medium parameters used: {= 835 MHz; 0 = 0.987 $/m; s = 54.827; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.7 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(9.49, 9.49, 9.49); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =3.17 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=Smm
Reference Value= 51.81 V/m; Power Drift =—0.07 dB
Peak SAR (extrapolated) = 3.68 W/kg
SAR(1 g) = 2.52 W/kg; SAR(1O g) = 1.66 W/kg
Maximum value of SAR (measured) =3.18 W/kg

     dB
     0


      —2.06


      —4.13


      5.19


      .26                          /

      10.32
               0 dB =3.18 W/kg = 5.02 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.21

System Check_Body_1750MHz

DUT: D1750V2 — SN:1137

Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1
Medium: MSL_1750 Medium parameters used: £= 1750 MHz; a=1.521 S/m; e =54.081; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.7 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(8.15, 8.15, 8.15); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 12.6 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=Smm
Reference Value=77.04 V/m; Power Drift =—0.08 dB
Peak SAR (extrapolated) = 15.3 W/kg
SAR(1 g) = 9.06 W/kg; SAR(10 g) = 4.96 W/kg
Maximum value of SAR (measured) = 12.4 W/kg

     dB
     0


      —3.23


      —6.47


      —9.70


      ~12.94


      16.17
               0 dB = 12.4 W/kg =10.93 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.22

System Check_Body_1900MHz

DUT: D1900V2 — SN: 50182

Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: MSL_1900 Medium parameters used: £= 1900 MHz; a= 1.534 S/m; e = 53.035; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.6 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(7.82, 7.82, 7.82); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM1; Type: SAM; Serial: TP—1842
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 13.3 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=Smm
Reference Value=72.02 V/m; Power Drift =—0.05 dB
Peak SAR (extrapolated) = 16.5 Wkg
SAR(1 g) = 9.51 W/kg; SAR(1O g) = 5.02 W/kg
Maximum value of SAR (measured) = 13.3 W/kg

     dB
     0


      —3.44


      5.87


      10.31


      ~13.74


      1718
               0 dB = 13.3 W/kg =11.24 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.23

System Check_Body_2450MHz

DUT: D2450V2 — SN:736

Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: MSL_2450 Medium parameters used: £=2450 MHz; 0 =2.014 S/m; e = 52.835; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.8 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(7.42, 7.42, 7.42); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 19.6 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=Smm, daz=Smm
Reference Value=85.83 V/m; Power Drift =—0.18 dB
Peak SAR (extrapolated) = 26.0 W/kg
SAR(1 g) = 12.9 W/kg; SAR(1O g) = 6.11 W/kg
Maximum value of SAR (measured) = 19.6 W/kg

     dB
     0


      ~4.07


      8.13


      12.20


      ~16.26


      —20.33
               0 dB = 19.6 W/kg =12.92 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.22

System Check_Body_2600MHz

DUT: D2600V2 — SN:1061

Communication System: UID 0, CW (0); Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: MSL_2600 Medium parameters used: £= 2600 MHz; a=2.217 S/m; e = 52.913; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.9 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(7.38, 7.38, 7.38); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=250mW/Area Scan (71x71x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) =22.0 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=Smm, daz=Smm
Reference Value=71.22 V/m; Power Drift=0.02 dB
Peak SAR (extrapolated) = 30.2 W/kg
SAR(1 g) = 13.9 W/kg; SAR(1O g) = 6.15 W/kg
Maximum value of SAR (measured) =21.8 W/kg

     dB
     0


      ~4.75


      —9.50


      —14.24


      —18.99


      —23.74
               0 dB = 21.8 W/kg =13.38 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.19

System Check_Body_5250MHz

DUT: DSGHzV2—SN:1006

Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1
Medium: MSL_5000 Medium parameters used: £= 5250 MHz; 0 = 5.542 S/m; e = 48.702; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.9 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(4.4, 4.4, 4.4); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 16.9 W/kg

Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value=38.01 V/m; Power Drift=0.01 dB
Peak SAR (extrapolated) = 28.5 Wkg
SAR(1 g) = 7.29 Wi/kg; SAR(1O g) = 2.05 W/kg
Maximum value of SAR (measured) =16.6 W/kg

     dB
     0


      —5.560


      —11.20


      —16.00


      —22.40


      —28.00
               0 dB = 16.6 W/kg =12.20 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.22

System Check_Body_5600MHz

DUT: DSGHzV2—SN:1006

Communication System: UID 0, CW (0); Frequency: 5600 MHz;Duty Cycle: 1:1
Medium: MSL_5000 Medium parameters used: £= 5600 MHz; a=6.017 S/m; e = 48.108; p = 1000
kg/m3
Ambient Temperature : 23.4 °C; Liquid Temperature : 22.6 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(3.98, 3.98, 3.98); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 18.9 W/kg

Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value=36.88 V/m; Power Drift =0.03 dB
Peak SAR (extrapolated) = 32.3 Wkg
SAR(1 g) = 7.63 Wi/kg; SAR(1O g) = 2.12 W/kg
Maximum value of SAR (measured) = 18.4 W/kg

     dB
     0


      —5.560


      —11.20


      —16.00


      —22.40


      —28.00
               0 dB = 18.4 W/kg =12.65 dBWi/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019.3.20

System Check_Body_5750MHz

DUT: DSGHzV2—SN:1006

Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1
Medium: MSL_5000 Medium parameters used: £= 5750 MHz; 0 =6.229 S/m; e = 47.865; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.8 °C

DASY S Configuration:
—   Probe: EX3DV4 — SN3857; ConvF(4.31, 4.31, 4.31); Calibrated: 2018.5.31
—   Sensor—Surface: 1.Amm (Mechanical Surface Detection)
—   Electronics: DAE4 Sn1210; Calibrated: 2019.1.25
—   Phantom: SAM2; Type: SAM; Serial: TP:1754
—   Measurement SW: DASY52, Version 52.10 (1); SEMCAD X Version 14.6.11 (7439)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 16.8 W/kg

Pin=100mW/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value=35.38 V/m; Power Drift =0.08 dB
Peak SAR (extrapolated) = 28.9 Wkg
SAR(1 g) = 7.22 W/kg; SAR(10 g) = 1.99 W/kg
Maximum value of SAR (measured) = 16.7 W/kg

     dB
     0


      —7.60


      15.20


      —22.00


      —30.40


      —38.00
               0 dB = 16.7 Wikg =12.23 dBWi/kg