Test Report HAC RF Appendix A

FCC ID: IHDT56XP2

Test Report

Download: PDF
FCCID_4075288

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2018/10/10


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.3 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2018/1/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 132.2 V/m; Power Drift = -0.02 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 115.3 V/m
Average value of Total=(115+115.3) / 2 = 115.15 V/m

                                         PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          111.8 V/m      115.0 V/m   113.5 V/m
                                          Grid 4 M4      Grid 5 M4   Grid 6 M4
                                          64.93 V/m      66.41 V/m   65.59 V/m
                                          Grid 7 M4      Grid 8 M4   Grid 9 M4
                                          113.2 V/m      115.3 V/m   113.3 V/m
                                                        Cursor:
                                                   Total = 115.3 V/m
                                                    E Category: M4
                                                Location: 0, 70.5, 9.7 mm




                    0 dB = 115.3 V/m = 41.24 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2018/10/10


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.3 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2018/1/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 143.7 V/m; Power Drift = 0.04 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 93.05 V/m
Average value of Total=(90.32+93.05) / 2 = 91.685 V/m

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          89.50 V/m      90.32 V/m   88.30 V/m
                                          Grid 4 M3      Grid 5 M3   Grid 6 M3
                                          72.35 V/m      73.66 V/m   72.87 V/m
                                          Grid 7 M3      Grid 8 M3   Grid 9 M3
                                          91.38 V/m      93.05 V/m   91.17 V/m
                                                        Cursor:
                                                   Total = 93.05 V/m
                                                    E Category: M3
                                                 Location: 0, 31, 9.7 mm




                    0 dB = 93.05 V/m = 39.37 dBV/m



Document Created: 2019-03-26 13:50:37
Document Modified: 2019-03-26 13:50:37

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC