IHDT56XN2 Test Report NII DFS

FCC ID: IHDT56XN3

Test Report

Download: PDF
FCCID_4054459

            FCC DFS TEST REPORT                                                         Report No. : FZ890437




                       FCC DFS TEST REPORT
               FCC ID                    : IHDT56XN2
               Equipment                 : Mobile Cellular Phone
               Brand Name                : Motorola
               Model Name                : XT1965-2
               Applicant                 : Motorola Mobility LLC
                                           222 W,Merchandise Mart Plaza, Chicago IL
                                           60654 USA
               Manufacturer              : Motorola Mobility LLC
                                           222 W,Merchandise Mart Plaza, Chicago IL
                                           60654 USA
               Standard                  : FCC Part 15 Subpart E

The product was received on Sep. 04, 2018 and testing was started from Sep. 28, 2018 and
completed on Sep. 28, 2018. We, SPORTON INTERTIONAL INC. EMC & Wireless Communications
Laboratory, would like to declare that the tested sample has been evaluated in accordance with the
procedures given in FCC Part 15 Subpart E and shown compliance with the applicable technical
standards.

The report must not be used by the client to claim product certification, approval, or endorsement by
TAF or any agency of government.

The test results in this report apply exclusively to the tested model / sample. Without written
approval of SPORTON INTERTIONAL INC. EMC & Wireless Communications Laboratory, the test
report shall not be reproduced except in full.




             Approved by: Jones Tsai
     SPORTON INTERTIONAL INC. EMC & Wireless Communications Laboratory
                       No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.)
TEL : 886-3-327-3456                                                         Page Number       : 1 of 20
FAX : 886-3-328-4978                                                         Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                Report Version    : 01


               FCC DFS TEST REPORT                                                                                           Report No. : FZ890437




                                                          Table of Contents
History of this test report ................................................................................................................................. 3
Summary of Test Result................................................................................................................................... 4
1 General Description ................................................................................................................................... 5
    1.1    Feature of Equipment Under Test .................................................................................................... 5
    1.2    Modification of EUT .......................................................................................................................... 6
    1.3    Product Specification of Equipment Under Test ............................................................................... 7
    1.4    Testing Site ....................................................................................................................................... 7
    1.5    Applied Standards ............................................................................................................................ 7
    1.6    Support Unit used in test configuration and system ......................................................................... 7
2 Requirements and Parameters for DFS Test........................................................................................... 8
    2.1    Summary of Dynamic Frequency Selection Test ............................................................................. 8
    2.2    Applicability of DFS Requirements ................................................................................................... 9
    2.3    Interference Threshold values, Master or Client incorporating In-Service Monitoring ................... 10
    2.4    DFS Response requirement values................................................................................................ 10
    2.5    Short Pulse Radar Test Waveforms ............................................................................................... 11
3 Calibration Setup and DFS Test Results ............................................................................................... 12
    3.1    Calibration of Radar Waveform ...................................................................................................... 12
    3.2    In-Service Monitoring: Channel Move Time, Channel Closing Transmission Time and
           Non-Occupancy Period................................................................................................................... 14
4 List of Measuring Equipment .................................................................................................................. 20




TEL : 886-3-327-3456                                                                                           Page Number               : 2 of 20
FAX : 886-3-328-4978                                                                                           Issued Date               : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                                                  Report Version            : 01


            FCC DFS TEST REPORT                                                      Report No. : FZ890437




                                    History of this test report

     Report No.         Version                             Description                      Issue Date

     FZ890437               01        Initial issue of report                              Oct. 04, 2018




TEL : 886-3-327-3456                                                      Page Number       : 3 of 20
FAX : 886-3-328-4978                                                      Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                             Report Version    : 01


            FCC DFS TEST REPORT                                                       Report No. : FZ890437




                                     Summary of Test Result

Report      Ref Std.                                                Result
                                         Test Items                                           Remark
Clause      Clause                                               (PASS/FAIL)


                                   Channel Move Time                Pass                    0.5549 sec


                                                                                         <200ms + 23.6 ms
   3.2        7.8.3       Channel Closing Transmission time         Pass
                                                                                            (aggregate)

                               Non-Occupancy Period and                                  No transmission or
                                                                    Pass
                                  Client Beacon Test                                     Beacons occurred

Note: Since the product is client without radar detection function, only Channel Move Time, Channel Closing
Transmission Time and Non-Occupancy Period Test are required to be performed.


Reviewed by: Louis Wu
Report Producer: Wii Chang




TEL : 886-3-327-3456                                                       Page Number         : 4 of 20
FAX : 886-3-328-4978                                                       Issued Date         : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                              Report Version      : 01


            FCC DFS TEST REPORT                                                  Report No. : FZ890437

1      General Description
1.1 Feature of Equipment Under Test
                                                Product Feature
        Equipment                               Mobile Cellular Phone
        Brand Name                              Motorola
        Model Name                              XT1965-2
        Sample 1                                Dual SIM
        Sample 2                                Single SIM
        FCC ID                                  IHDT56XN2
                                                IMEI 1: 355577090032671
        IMEI Code
                                                IMEI 2: 355577090032689
                                                GSM/EGPRS/WCDMA/HSPA/LTE/GNSS/NFC/FM
                                                WLAN 11b/g/n/ac HT20/VHT20
        EUT supports Radios application         WLAN 11a/n HT20/HT40
                                                WLAN 11ac VHT20/VHT40/VHT80
                                                Bluetooth BR/EDR/LE
        HW Version                              DVT1-B
        EUT Stage                               Identical Prototype
       Remark:
       1. The above EUT's information was declared by manufacturer.
       2. All the test cases were performed with Sample 1.




TEL : 886-3-327-3456                                                  Page Number       : 5 of 20
FAX : 886-3-328-4978                                                  Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                         Report Version    : 01


            FCC DFS TEST REPORT                                                 Report No. : FZ890437



                                                 Accessory List
                                                Brand Name : Motorola
       AC Adapter 1                             Model Name : SC-31
                                                Manufacturer : Salom
                                                Brand Name : Motorola
       AC Adapter 1                             Model Name : SC-32
                                                Manufacturer : Salom
                                                Brand Name : Motorola
       AC Adapter 1                             Model Name : SC-37
                                                Manufacturer : Salom
                                                Brand Name : Motorola
       AC Adapter 1                             Model Name : SC-36
                                                Manufacturer : Salom
                                                Brand Name : Motorola
       AC Adapter 1                             Model Name : SC-32
                                                Manufacturer : Salom
                                                Brand Name : Motorola
       AC Adapter 2                             Model Name : SC-31
                                                Manufacturer : Acbel
                                                Brand Name : Motorola
       AC Adapter 2                             Model Name : SC-32
                                                Manufacturer : Acbel
                                                Brand Name : Motorola
       AC Adapter 2                             Model Name : SC-36
                                                Manufacturer : Acbel
                                                Brand Name : Motorola
       AC Adapter 2                             Model Name : SC-37
                                                Manufacturer : Acbel
                                                Brand Name : Motorola
       Battery                                  Model Name : JG40
                                                Manufacturer : Amperex
                                                Brand Name : Motorola
       Earphone                                 Model Name : SH38C37773
                                                Manufacturer : Lyand
                                                Brand Name : Cabletech
       USB Cable 1
                                                Model Name : SC18C37155
                                                Brand Name : Luxshare
       USB Cable 2
                                                Model Name : SC18C37156
                                                Brand Name : Saibao
       USB Cable 3
                                                Model Name : SC18C37157


1.2 Modification of EUT
       No modifications are made to the EUT during all test items.




TEL : 886-3-327-3456                                                 Page Number       : 6 of 20
FAX : 886-3-328-4978                                                 Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                        Report Version    : 01


             FCC DFS TEST REPORT                                                           Report No. : FZ890437

1.3 Product Specification of Equipment Under Test
                                   Product Specification subjective to this standard
        DFS Function                                   Client without radar detection function
                                                       5260 MHz ~ 5320 MHz
        Tx/Rx Channel Frequency Range
                                                       5500 MHz ~ 5700 MHz
                                                       <5260 MHz ~ 5320 MHz>
                                                       802.11a/n HT20/HT40
                                                       802.11ac VHT20/VHT40/VHT80
        EUT support WLAN function
                                                       <5500 MHz ~ 5700 MHz >
                                                       802.11a/n HT20/HT40
                                                       802.11ac VHT20/VHT40/VHT80
                                                       802.11a/n: OFDM (BPSK / QPSK / 16QAM / 64QAM)
        Type of Modulation                             802.11ac:OFDM (BPSK / QPSK / 16QAM / 64QAM /
                                                       256QAM)


1.4 Testing Site
        Test Site                  SPORTON INTERNATIONAL INC.
                                   No.52, Huaya 1st Rd., Guishan Dist.,
                                   Taoyuan City, Taiwan (R.O.C.)
        Test Site Location
                                   TEL: +886-3-327-3456
                                   FAX: +886-3-328-4978
                                                               Sporton Site No.
        Test Site No.
                                                                     DFS02-HY


1.5 Applied Standards
      According to the specifications of the manufacturer, the EUT must comply with the requirements of the
      following standards:
        FCC Part 15 Subpart E
        FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02
        FCC KDB 905462 D03 UNII Clients Without Radar Detection New Rules v01r02
      Remark: All test items were verified and recorded according to the standards and without any deviation
      during the test.


1.6 Support Unit used in test configuration and system
       Item Equipment       Trade Name Model Name           FCC ID          Data Cable           Power Cord

        1.   WLAN AP        Motorola      AP-7532B          UZ7AP7532       FW: WiNG v5.8        Unshielded, 1.8 m
                                                                                                 AC I/P:
                                                                                                 Unshielded, 1.2 m
        2.   Notebook       acer          N15C1             PPD-QCNFA435    N/A
                                                                                                 DC O/P:
                                                                                                 Shielded, 1.8 m



TEL : 886-3-327-3456                                                            Page Number        : 7 of 20
FAX : 886-3-328-4978                                                            Issued Date        : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                   Report Version     : 01


            FCC DFS TEST REPORT                                                      Report No. : FZ890437

2      Requirements and Parameters for DFS Test
2.1 Summary of Dynamic Frequency Selection Test
           Bandwidth
                                                    Test Items                               Limit
          and Channel

                                                  80MHz 5530MHz (CH106)

                                                Channel Move Time                           10 sec

             80MHz                                                                     200 ms +
                                                 Channel Closing
            (CH106)                                                              aggregate of 60 ms over
                                                Transmission time
            5530MHz                                                               remaining 10 s period
                                          Non-Occupancy Period and
                                                                                           30 minutes
                                             Client Beacon Test




TEL : 886-3-327-3456                                                      Page Number          : 8 of 20
FAX : 886-3-328-4978                                                      Issued Date          : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                             Report Version       : 01


            FCC DFS TEST REPORT                                                           Report No. : FZ890437

2.2 Applicability of DFS Requirements
      EUT is client and operates as client without radar detection function.


       Table 1: Applicability of DFS Requirements Prior to Use of a Channel

                                                                       Operational Mode
                       Requirement                                           Client                 Client With
                                                        Master           Without Radar                 Radar
                                                                           Detection                Detection

                 Non-Occupancy Period                     Yes             Not required                      Yes

               DFS Detection Threshold                    Yes             Not required                      Yes

           Channel Availability Check Time                Yes             Not required              Not required

               U-NII Detection Bandwidth                  Yes             Not required                      Yes


       Table 2: Applicability of DFS requirements during normal operation
                                                                       Operational Mode
                                                                            Client                     Client
                       Requirement
                                                        Master          Without Radar                With Radar
                                                                          Detection                  Detection
             DFS Detection Threshold                      Yes            Not required                   Yes
         Channel Closing Transmission Time                Yes                 Yes                       Yes
                Channel Move Time                         Yes                 Yes                       Yes
             U-NII Detection Bandwidth                    Yes            Not required                   Yes
                 Client Beacon Test                       N/A                 Yes                       Yes

                                                                       Operational Mode
         Additional requirements for devices               Master or
                                                                                              Client
           with multiple bandwidth modes                  Client With
                                                                                     Without Radar Detection
                                                        Radar Detection
            U-NII Detection Bandwidth and                All BW modes
                                                                                                Not required
            Statistical Performance Check                must be tested
                                                                                        Test using the widest
           Channel Move Time and Channel              Test using widest BW
                                                                                         BW mode available
             Closing Transmission Time                   mode available
                                                                                             for the link
                       All other tests                Any single BW mode                    Not required
        Note
        Frequencies selected for statistical performance check (Section 7.8.4) should include
        several frequencies within the radar detection bandwidth and frequencies near the edge of
        the radar detection bandwidth. For 802.11 devices it is suggested to select frequencies in
        each of the bonded 20 MHz channels and the channel center frequency.



TEL : 886-3-327-3456                                                           Page Number           : 9 of 20
FAX : 886-3-328-4978                                                           Issued Date           : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                  Report Version        : 01


            FCC DFS TEST REPORT                                                          Report No. : FZ890437

2.3 Interference Threshold values, Master or Client incorporating
    In-Service Monitoring
                       Maximum Transmit Power                             Value (see notes 1 and 2)
                             ≥ 200 milliwatt                                        -64 dBm
                             < 200 milliwatt                                        -62 dBm
        Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
        Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the
        test transmission waveforms to account for variations in measurement equipment. This will ensure
        that the test signal is at or above the detection threshold level to trigger a DFS response.
       The radar Detection Threshold, lowest antenna gain is the parameter of Interference radar DFS
       detection threshold, The Interference Detection Threshold is the ( -62dBm) + (0) [dBi]+ 1 dB= -61 dBm.

2.4 DFS Response requirement values
                      Parameter                                                Value
        Non-occupancy period                          Minimum 30 minutes
        Channel Availability Check Time               60 seconds
        Channel Move Time                             10 seconds See Note 1.
        Channel Closing Transmission Time             200 milliseconds + an aggregate of 60 milliseconds over
                                                      remaining 10 second period. See Notes 1 and 2.
        U-NII Detection Bandwidth                     Minimum 100% of the 99% power bandwidth
                                                      See Note 3.
        Note 1: The instant that the Channel Move Time and the Channel Closing Transmission Time begins
        is as follows:
           • For the Short pulse radar Test Signals this instant is the end of the Burst.
           • For the Frequency Hopping radar Test Signal, this instant is the end of the last radar Burst
           generated.
           • For the Long Pulse radar Test Signal this instant is the end of the 12 second period defining the
           radar transmission.
        Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the
        beginning of the Channel Move Time plus any additional intermittent control signals required to
        facilitate Channel changes (an aggregate of 60 milliseconds) during the remainder of the 10 second
        period. The aggregate duration of control signals will not count quiet periods in between
        transmissions.
        Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 is used and for each
        frequency step the minimum percentage of detection is 90%. Measurements are performed with no
        data traffic.




TEL : 886-3-327-3456                                                          Page Number        : 10 of 20
FAX : 886-3-328-4978                                                          Issued Date        : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                 Report Version     : 01


            FCC DFS TEST REPORT                                                         Report No. : FZ890437

2.5 Short Pulse Radar Test Waveforms
       As the EUT is a Client Device with no Radar Detection, only one type radar pulse is required for the
       testing. Radar Pulse type 0 was used in the evaluation of the Client device for the purpose of
       measuring the Channel Move Time and the Channel Closing Transmission Time.
                                                                                Minimum
                       Pulse
        Radar                                                                 Percentage of           Minimum
                       Width     PRI (µsec)      Number of Pulses
        Type                                                                   Successful              Trials
                       (µsec)
                                                                                Detection
           0             1          1428                 18                         60%                     30



                                    Test A
           1             1                                                         60%                  30
                                   Test B



           2            1-5       150-230              23-29                        60%                     30
           3           6-10       200-500              16-18                        60%                     30
           4           11-20      200-500              12-16                        60%                     30
        Aggregate (Radar Types 1-4)                                                 80%                 120


       Test A: 15 unique PRI values randomly selected from the list of 23 PRI values in Table 5a
       Test B: 15 unique PRI values randomly selected within the range of 518-3066 μsec, with a minimum
       increment of 1 μsec, excluding PRI values selected in Test A


       A minimum of 30 unique waveforms are required for each of the short pulse radar types 2 through 4.
       For short pulse radar type 1, the same waveform is used a minimum of 30 times. If more than 30
       waveforms are used for short pulse radar types 2 through 4, then each additional waveform must also
       be unique and not repeated from the previous waveforms.

       If more than 30 waveforms are used for Short Pulse Radar Type 1, then each additional waveform is
       generated with Test B and must also be unique and not repeated from the previous waveforms in Tests
       A or B.

       The aggregate is the average of the percentage of successful detections of short pulse radar types 1-4.




TEL : 886-3-327-3456                                                         Page Number       : 11 of 20
FAX : 886-3-328-4978                                                         Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                Report Version    : 01


            FCC DFS TEST REPORT                                                       Report No. : FZ890437

3      Calibration Setup and DFS Test Results
3.1 Calibration of Radar Waveform
3.1.1 Radar Waveform Calibration Procedure
         The Interference Radar Detection Threshold Level is (-62dBm) + (0) [dBi]+ 1 dB= -61dBm that had
         been taken into account the output power range and antenna gain. The following equipment setup
         was used to calibrate the radiated Radar Waveform. A vector signal generator was utilized to
         establish the test signal level for radar type 0. During this process there were no transmissions by
         either the Master or Client Device. The spectrum analyzer was switched to the zero span (Time
         Domain) at the frequency of the Radar Waveform generator. Peak detection was used. The spectrum
         analyzer resolution bandwidth (RBW) and video bandwidth (VBW) were set to 3 MHz to measure the
         type 0 radar waveform. The spectrum analyzer had offset to compensate and RF cable loss. The
         vector signal generator amplitude was set so that the power level measured at the spectrum analyzer
         was (-62dBm) + (0) [dBi]+ 1 dB= -61 dBm. Capture the spectrum analyzer plots on short pulse radar
         waveform.


3.1.2 Conducted Setup




3.1.3 Calibration Deviation
         There is no deviation with the original standard.




TEL : 886-3-327-3456                                                       Page Number       : 12 of 20
FAX : 886-3-328-4978                                                       Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                              Report Version    : 01


            FCC DFS TEST REPORT                                                         Report No. : FZ890437


3.1.4 Radar Waveform Calibration Result
                                                <80MHz / 5530MHz> Radar Type 0
             Radar / DFS detection threshold level and the burst of pulses on the Channel frequency




TEL : 886-3-327-3456                                                         Page Number       : 13 of 20
FAX : 886-3-328-4978                                                         Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                Report Version    : 01


            FCC DFS TEST REPORT                                                       Report No. : FZ890437

3.2 In-Service Monitoring: Channel Move Time, Channel Closing
    Transmission Time and Non-Occupancy Period
3.2.1 Limit of In-Service Monitoring
         The EUT has In-Service Monitoring function to continuously monitor the radar signals, If radar is
         detected, it must leave the channel (Shutdown). The Channel Move Time to cease all transmissions
         on the current Channel upon detection of a Radar Waveform above the DFS Detection Threshold
         within 10 sec. The total duration of Channel Closing Transmission Time is comprised of 200
         milliseconds starting at the beginning of the Channel Move Time plus any additional intermittent
         control signals required to facilitate Channel changes (an aggregate of 60 milliseconds) during the
         remainder of the 10 second period. The aggregate duration of control signals will not count quiet
         periods in between transmissions.
         Non-Occupancy Period time is 30 minute during which a Channel will not be utilized after a Radar
         Waveform is detected on that Channel. The non-associated Client Beacon Test is during the 30
         minutes observation time. The EUT should not make any transmissions in the DFS band after EUT
         power up.




TEL : 886-3-327-3456                                                       Page Number       : 14 of 20
FAX : 886-3-328-4978                                                       Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                              Report Version    : 01


              FCC DFS TEST REPORT                                                        Report No. : FZ890437


3.2.2 Test Procedures
         1.    The radar pulse generator is setup to provide a pulse at frequency that the Master and Client are
               operating. A type 0 radar pulse with a 1us pulse width and a 1428 us PRI is used for the testing.
         2.    The vector signal generator is adjusted to provide the radar burst (18 pulses) at a level of
               approximately -62dBm at the antenna of the Master device.
         3.    A trigger is provided from the pulse generator to the DFS monitoring system in order to capture
               the traffic and the occurrence of the radar pulse.
         4.    A U-NII device operating as a Client Device will associate with the Master at Channel. The
               MPEG file “TestFile.mpg” specified by the FCC is streamed from the “file computer” through the
               Master to the Client Device and played in full motion video using Media Player Classic Ver.
               6.4.8.6 in order to properly load the network for the entire period of the test.
         5.    When a radar Burst with a level equal to the DFS Detection Threshold + 1dB is generated on the
               Operating Channel of the U-NII device. At time T0 the Radar Waveform generator sends a Burst
               of pulse of the radar waveform at Detection Threshold + 1dB.
         6.    Observe the transmissions of the EUT at the end of the radar Burst on the Operating Channel.
               Measure and record the transmissions from the EUT during the observation time (Channel Move
               Time). One 12 seconds plot is reported for the Short Pulse Radar Types 0. The plot for the Short
               Pulse Radar Types start at the end of the radar burst. The Channel Move Time will be calculated
               based on the zoom in 600ms plot of the Short Pulse Radar Type.
         7.    Measurement of the aggregate duration of the Channel Closing Transmission Time method.
               With the spectrum analyzer set to zero span tuned to the center frequency of the EUT operating
               channel at the radar simulated frequency, peak detection, and max hold, the dwell time per bin is
               given by: Dwell (0.4ms)= S (12000ms) / B (30000); where Dwell is the dwell time per spectrum
               analyzer sampling bin, S is the sweep time and B is the number of spectrum analyzer sampling
               bins. An upper bound of the aggregate duration of the intermittent control signals of Channel
               Closing Transmission Time is calculated by: C (ms)= N X Dwell (0.4 ms); where C is the Closing
               Time, N is the number of spectrum analyzer sampling bins (intermittent control signals) showing
               a U-NII transmission and Dwell is the dwell time per bin.
         8.    Measure the EUT for more than 30 minutes following the channel move time to verify that no
               transmissions or beacons occur on this Channel.
         9.    The test frequency , bandwidth and data rate as following table:
                            BW / Channel                                    Test Data Rate
                          80MHz / 5530MHz                                         MCS0




TEL : 886-3-327-3456                                                          Page Number       : 15 of 20
FAX : 886-3-328-4978                                                          Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                 Report Version    : 01


            FCC DFS TEST REPORT                                         Report No. : FZ890437


3.2.3 Test Setup
         Conducted Setup Photo




3.2.4 Test Deviation
         There is no deviation with the original standard.




TEL : 886-3-327-3456                                         Page Number       : 16 of 20
FAX : 886-3-328-4978                                         Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                Report Version    : 01


 seovc«s. FCC DFS TEST REPORT                                                            Report No. : FZ890437


3.2.5 Result of Channel Move Time, Channel Closing Transmission Time and
Non—Occupancy Period for Client Beacon Test
Test Mode :         Client without radar detection                 [Temperature :              24—26°C
Test Engineer : |AnAn Wu                                           Relative Humidity :         |50—52%


     BW /                        Test Item                    Test Result                 Limit          Pass/Fail
   Channel

                           Channel Move Time                    0.5549 s                 < 10s              Pass
   BOMHz /
                  Channel Closing Transmission Time         200ms + 23.6 ms            < 260ms              Pass
  5530MHz
                         Non—Occupancy Period                     > 30                  > 30 min            Pass

Note: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning of
the Channel Move Time plus any additional intermittent control signals required to facilitate a Channel move
(an aggregate of 60 milliseconds) during the remainder of the 10 seconds period. The aggregate duration of

control signals will not count quiet periods in between transmissions.




TEL : 886—3—327—3456                                                          Page Number          : 17 of 20
FAX : 886—3—328—4978                                                          Issued Date          : Oct. 04, 2018
Report Template No.: BUS—FZ15EDFS Version 1.1                                 Report Version       : 01


            FCC DFS TEST REPORT                                                          Report No. : FZ890437


3.2.6 Channel Move Time, Channel Closing Transmission Time and Non-Occupancy
Period for Client Beacon Test Plots
                                        <80MHz / 5530MHz> In-Service Monitoring
                                                Channel Move Time &
                                       Channel Closing Transmission Time




                                                                          Non-associated test
                Non-Occupancy Period
                                                                      Master was off. (beacon test)




Note:
Dwell (0.4 ms)= Sweep Time (12000 ms) / Sweep Point Bins (30000)
Channel Closing Transmission Time (200 + 23.6 ms) = 200 + Number (59) X Dwell (0.4 ms) < 260ms




TEL : 886-3-327-3456                                                          Page Number       : 18 of 20
FAX : 886-3-328-4978                                                          Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                                 Report Version    : 01


            FCC DFS TEST REPORT                                                        Report No. : FZ890437


3.2.7 Data Traffic and Noise Floor Plots
                                                EUT data traffic (Client)




                                          Noise Floor (No transmission)




TEL : 886-3-327-3456                                                        Page Number       : 19 of 20
FAX : 886-3-328-4978                                                        Issued Date       : Oct. 04, 2018
Report Template No.: BU5-FZ15EDFS Version 1.1                               Report Version    : 01


                FCC DFS TEST REPORT                                                                         Report No. : FZ890437

  4         List of Measuring Equipment
                                                                                Calibration
 Instrument     Manufacturer    Model No.       Serial No.   Characteristics                    Test Date        Due Date         Remark
                                                                                   Date
   Signal         Rohde &                                                                                                          DFS
                                SMJ100A          101375      100kHz~6GHz       Jan. 23, 2018   Sep. 28, 2018 Jan. 22, 2019
 Generator        Schwarz                                                                                                     (DFS02-HY)
  Spectrum                                                                                                                         DFS
                  Keysight       N9010A        MY57120184     10Hz~7GHz        Nov. 08, 2017 Sep. 28, 2018 Nov. 07, 2018
  Analyzer                                                                                                                    (DFS02-HY)
                                3Way SMA       ST108-0010                       Calibration                     Calibration        DFS
Power Divider     Woken                                        2G~8GHz                         Sep. 28, 2018
                               Power Divider      (#4)                         from System                      from System   (DFS02-HY)
                                2Way SMA                                        Calibration                     Calibration        DFS
Power Divider       MTJ                         MD10007       0.5G~6GHz                        Sep. 28, 2018
                               Power Divider                                   from System                      from System   (DFS02-HY)
                                SMA 2Way                                        Calibration                     Calibration        DFS
Power Divider     Woken                        STI08-0011    2GHz-18GHz                        Sep. 28, 2018
                               Power Divider                                   from System                      from System   (DFS02-HY)
                                4Way SMA       0120A020560                      Calibration                     Calibration        DFS
Power Divider     Woken                                       0.5G~6GHz                        Sep. 28, 2018
                               Power Divider      02D                          from System                      from System   (DFS02-HY)
                    MTJ        SBF405-105F                                      Calibration                     Calibration        DFS
  RF Cable                                     MTJ-30cm-01 30 kHz~18GHz                        Sep. 28, 2018
                Cooperstion        LEX                                         from System                      from System   (DFS02-HY)
                    MTJ        SBF405-105F                                      Calibration                     Calibration        DFS
  RF Cable                                     MTJ-30cm-02 30 kHz~18GHz                        Sep. 28, 2018
                Cooperstion        LEX                                         from System                      from System   (DFS02-HY)
                    MTJ        SBF405-105F                                      Calibration                     Calibration        DFS
  RF Cable                                     MTJ-30cm-03 30 kHz~18GHz                        Sep. 28, 2018
                Cooperstion        LEX                                         from System                      from System   (DFS02-HY)
                    MTJ        SBF405-105F                                      Calibration                     Calibration        DFS
  RF Cable                                     MTJ-30cm-04 30 kHz~18GHz                        Sep. 28, 2018
                Cooperstion        LEX                                         from System                      from System   (DFS02-HY)
                    MTJ        SBF405-105F                                      Calibration                     Calibration        DFS
  RF Cable                                     MTJ-30cm-05 30 kHz~18GHz                        Sep. 28, 2018
                Cooperstion        LEX                                         from System                      from System   (DFS02-HY)
                    MTJ        SBF405-105F                                      Calibration                     Calibration        DFS
  RF Cable                                     MTJ-30cm-06 30 kHz~18GHz                        Sep. 28, 2018
                Cooperstion        LEX                                         from System                      from System   (DFS02-HY)
                    MTJ        SBF405-105F                                      Calibration                     Calibration        DFS
  RF Cable                                     MTJ-30cm-08 30 kHz~18GHz                        Sep. 28, 2018
                Cooperstion        LEX                                         from System                      from System   (DFS02-HY)
                    MTJ        SBF405-105F                                      Calibration                     Calibration        DFS
  RF Cable                                     MTJ-30cm-09 30 kHz~18GHz                        Sep. 28, 2018
                Cooperstion        LEX                                         from System                      from System   (DFS02-HY)
                                                                                Calibration                     Calibration        DFS
  RF Cable        Woken        S05(100cm)       161202-04    30 kHz~18GHz                      Sep. 28, 2018
                                                                               from System                      from System   (DFS02-HY)
                                                                                Calibration                     Calibration        DFS
  RF Cable        Woken        S05(100cm)       161202-05    30 kHz~18GHz                      Sep. 28, 2018
                                                                               from System                      from System   (DFS02-HY)



                                                                                              ─────THE END─────




  TEL : 886-3-327-3456                                                                         Page Number           : 20 of 20
  FAX : 886-3-328-4978                                                                         Issued Date           : Oct. 04, 2018
  Report Template No.: BU5-FZ15EDFS Version 1.1                                                Report Version        : 01



Document Created: 2019-03-23 04:15:06
Document Modified: 2019-03-23 04:15:06