Test Report_HAC_RF Emission

FCC ID: IHDT56XL1

Test Report

Download: PDF
FCCID_4364333

         HAC RF EMISSIONS TEST REPORT                                                Report No. : HA890514-05A




         HEARING AID COMPATIBILITY
         RF EMISSIONS TEST REPORT
         FCC ID              : IHDT56WB1
         Equipment           : Mobile Cellular Phone
         Brand Name          : Motorola
         M-Rating            : M3
         Applicant    : Motorola Mobility LLC
                        222 W,Merchandise Mart Plaza, Chicago IL 60654 USA
         Manufacturer : Motorola Mobility LLC
                        222 W,Merchandise Mart Plaza, Chicago IL 60654 USA
         Standard     : FCC 47 CFR §20.19
                        ANSI C63.19-2011


      The product was received on May 24, 2019 and testing was started from Jun. 12, 2019 and
      completed on Jun. 12, 2019. We, SPORTON INTERNATIONAL INC., would like to declare
      that the tested sample has been evaluated in accordance with the test procedures and has
      been in compliance with the applicable technical standards.

      The report must not be used by the client to claim product certification, approval, or
      endorsement by TAF or any agency of government.

      The test results in this variant report apply exclusively to the tested model / sample.
      Without     written   approval of     SPORTON      INTERNATIONAL INC.        EMC       &   Wireless
      Communications Laboratory, the test report shall not be reproduced except in full.




      Approved by: Cona Huang / Deputy Manager



SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory
                       No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.)




TEL : 886-3-327-3456                                                                      Page : 1 of 18
FAX : 886-3-328-4978                                                               Issued Date : Jul. 09, 2019
Form version: 180516


             HAC RF EMISSIONS TEST REPORT                                                                                                 Report No. : HA890514-05A

                                                                Table of Contents
1.    General Information ................................................................................................................................................... 4
2.    Testing Location......................................................................................................................................................... 5
3.    Applied Standards ..................................................................................................................................................... 5
4.    Air Interface and Operating Mode when attach Mobile 5G MOD............................................................................ 5
5.    RF Audio Interference Level...................................................................................................................................... 6
6.    Measurement System Specification ......................................................................................................................... 7
      6.1     E-Field Probe System ....................................................................................................................................... 7
      6.2     Data Storage and Evaluation ............................................................................................................................ 8
7.    RF Emissions Test Procedure................................................................................................................................... 9
8.    Test Equipment List ..................................................................................................................................................12
9.    Measurement System Validation .............................................................................................................................13
10.   Modulation Interference Factor................................................................................................................................14
11.   Low-power Exemption for Mobile 5G MOD .............................................................................................................15
12.   Spot check RF Emission for Mobile cell phone......................................................................................................15
13.   Uncertainty Assessment ..........................................................................................................................................16
14.   References .................................................................................................................................................................18

Appendix A. Plots of System Performance Check
Appendix B. Plots of RF Emission Measurement
Appendix C. DASY Calibration Certificate




TEL : 886-3-327-3456                                                                                                                           Page : 2 of 18
FAX : 886-3-328-4978                                                                                                                    Issued Date : Jul. 09, 2019
Form version: 181113


         HAC RF EMISSIONS TEST REPORT                            Report No. : HA890514-05A


                         History of this test report
      Report No.       Version                    Description               Issued Date

    HA890514-05A       Rev. 01   Initial issue of report                    Jul. 09, 2019




TEL : 886-3-327-3456                                                   Page : 3 of 18
FAX : 886-3-328-4978                                            Issued Date : Jul. 09, 2019
Form version: 181113


          HAC RF EMISSIONS TEST REPORT                                                             Report No. : HA890514-05A
1. General Information
                                                Product Feature & Specification
Applicant Name             Motorola Mobility LLC
Equipment Name             Mobile Cellular Phone
Brand Name                 Motorola
FCC ID                     IHDT56WB1
EUT Stage                  Identical Prototype
                           GSM850: 824.2 MHz ~ 848.8 MHz
                           GSM1900: 1850.2 MHz ~ 1909.8 MHz
                           WCDMA Band II: 1852.4 MHz ~ 1907.6 MHz
                           WCDMA Band V: 826.4 MHz ~ 846.6 MHz
                           CDMA2000 BC0: 824.7 MHz ~ 848.31 MHz
                           CDMA 2000 BC1: 1851.25 MHz ~ 1908.75 MHz
                           LTE Band 2: 1850.7 MHz ~ 1909.3 MHz
                           LTE Band 4: 1710.7 MHz ~ 1754.3 MHz
                           LTE Band 5: 824.7 MHz ~ 848.3 MHz
                           LTE Band 7: 2502.5 MHz ~ 2567.5 MHz
                           LTE Band 12: 699.7 MHz ~ 715.3 MHz
Frequency Band             LTE Band 13: 779.5 MHz ~ 784.5 MHz
                           LTE Band 17: 706.5 MHz ~ 713.5 MHz
                           LTE Band 25: 1850.7 MHz ~ 1914.3 MHz
                           LTE Band 26: 814.7 MHz ~ 848.3 MHz
                           LTE Band 66: 1710.7 MHz ~ 1779.3 MHz
                           WLAN 2.4GHz Band: 2412 MHz ~ 2462 MHz
                           WLAN 5.2GHz Band: 5180 MHz ~ 5240 MHz
                           WLAN 5.3GHz Band: 5260 MHz ~ 5320 MHz
                           WLAN 5.5GHz Band: 5500 MHz ~ 5720 MHz
                           WLAN 5.8GHz Band: 5745 MHz ~ 5825 MHz
                           Bluetooth: 2402 MHz ~ 2480 MHz
                           NFC: 13.56 MHz
                           GSM/GPRS/EGPRS
                           AMR / RMC 12.2Kbps
                           HSDPA
                           HSUPA
                           DC-HSDPA
Mode                       CDMA2000 : 1xRTT/1xEv-Do(Rev.0)/1xEv-Do(Rev.A)
                           LTE: QPSK, 16QAM, 64QAM
                           WLAN 2.4GHz : 802.11b/g/n/ac HT20/VHT20
                           WLAN 5GHz : 802.11a/n/ac HT20/HT40/VHT20/VHT40/VHT80
                           Bluetooth BR/EDR/LE
                           NFC:ASK
Remark:
1.   When the mobile 5G MOD (FCC ID: IHDT56XL1) is attached to the phone (FCC ID: IHDT56WB1), the phone can utilize the mobile
     5G MOD wireless connect to the internet to do VoIP call, therefore, additional HAC testing was performed to show compliance.

Mobile 5G MOD (FCC ID: IHDT56XL1) information as follows :
Applicant Name             Motorola Mobility LLC
Equipment Name             Mobile 5G MOD
                           LTE Band 2: 1850.7 MHz ~ 1909.3 MHz
                           LTE Band 4: 1710.7 MHz ~ 1754.3 MHz
                           LTE Band 5: 824.7 MHz ~ 848.3 MHz
                           LTE Band 13: 779.5 MHz ~ 784.5 MHz
Frequency Band             LTE Band 66: 1710.7 MHz ~ 1779.3 MHz
                           LTE Band 48: 3552.5 MHz ~ 3697.5 MHz
                           5G NR n260: 37.05GHz~39.95GHz
                           5G NR n261: 27.5GHz~28.35GHz
                           LTE: QPSK, 16QAM, 64QAM
Mode                       5GNR n261: QPSK, 16QAM, and 64QAM for CP-OFDM



Reviewed by: Jason Wang
Report Producer: Wan Liu



TEL : 886-3-327-3456                                                                                    Page : 4 of 18
FAX : 886-3-328-4978                                                                             Issued Date : Jul. 09, 2019
Form version: 181113


seortron ias._HAC RF EMISSIONS TEST REPORT                                                                     Report No. : HA890514—05A
  2. Testing Location
  Sporton Lab is accredited to ISO 17025 by Taiwan Accreditation Foundation (TAF code: 1190) and the FCC designation
  No. TW 1190 under the FCC 2.948(e) by Mutual Recognition Agreement (MRA) in FCC test.

                                                                Testing Laboratory
  [Csc                                         SPORTON INTERNATIONAL INC.
                                               No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.0.C.)
  Test Site Location                           TEL: +886—3—327—3456
                                               FAX: +886—3—328—4978
                                               Sporton Site No.:
  Test Site No.
                                               SARO4—HY



  3. Applied Standards
       +     FCC CFR47 Part 20.19
       +     ANSIC63.19—2011
       +     FCC KDB 285076 DO1 HAC Guidance v05
       +_ FCC KDB 285076 DO2 T Coil testing v03
       +__FCC KDB 285076 D03 HAC FAQ v01



  4. Air Interface and Operating Mode when attach Mobile 5G MOD


                         Band 2
                         Band 4
                         Band 5                                                           .                     Google Duo
                         Band 13
                         Band 66
                         Band 48                                                          ,                     Google Duo
  Type Transport:
  VO= Voice only
  DT= Digital Transport only (no voice)
  VD= CMRS and IP Voice Service over Di            Tr       t
  Remark:
  1. The air interface is exempted from testing by low power exemption that its average antenna input power plus its MIF is <17 dBm,
      and is rated as M4.
  2.  According to ANSI C63.19 2011 —version, for the air interface technology of a device is exempt from testing whose peak antenna
           input power, averaged over intervals <50 us, is 23 dBm. An RF air interface technology that is exempted from testing shall be rated
           as M4

  5G MOD (FCC ID: IHDTSGXL1) itself does not support VoLTE, does not have the earpiece receiver on it to support
  next—to—ear voice call. 5G Mod is one accessory which IHDTSEWB1 supports, and when Mod is attached to the phone,
  Mod can provide the wireless data connection to the phone, to enable VoIP call application on the phone.

  This report is to address the compliance of:
  1.       HAGC rating of the air interfaces supported by the IHDTSBWBI1 is not impacted, when the Mod is attached. Worst case
           identified in the IHDTSEWB1 HAC test report (Sporton report: HABD2726—02A, Rev. 01, Date: 03/25/2019) was
           selected to evaluate the HAC rating with Mod attached.
  2.       HAC rating of IHDTSGWB1 is not impacted, when the Mod is attached and VoIP application wireless data is
           transported vis the air interfaces on Mod.




  TEL : 886—3—327—3456                                                                                              Page : 5 of 18
  FAX : 886—3—328—4978                                                                                       Issued Date : Jul. 09, 2019
  Form version: 181113


         HAC RF EMISSIONS TEST REPORT                                                      Report No. : HA890514-05A


5. RF Audio Interference Level
FCC wireless hearing aid compatibility rules ensure that consumers with hearing loss are able to access wireless
communications services through a wide selection of handsets without experiencing disabling radio frequency (RF)
interference or other technical obstacles.
To define and measure the hearing aid compatibility of handsets, in CFR47 part 20.19 ANSI C63.19 is referenced.
A handset is considered hearing aid-compatible for acoustic coupling if it meets a rating of at least M3 under ANSI
C63.19, and A handset is considered hearing aid compatible for inductive coupling if it meets a rating of at least T3.
According to ANSI C63.19 2011 version, for acoustic coupling, the RF electric field emissions of wireless
communication devices should be measured and rated according to the emission level as below.

                                                            E-field emissions
   Emission Categories
                                             <960Mhz                               >960Mhz
             M1                          50 to 55 dB (V/m)                     40 to 45 dB (V/m)
             M2                          45 to 50 dB (V/m)                     35 to 40 dB (V/m)
             M3                          40 to 45 dB (V/m)                     30 to 35 dB (V/m)
             M4                            <40 dB (V/m)                          <30 dB (V/m)
                           Table 5.1 Telephone near-field categories in linear units




TEL : 886-3-327-3456                                                                            Page : 6 of 18
FAX : 886-3-328-4978                                                                     Issued Date : Jul. 09, 2019
Form version: 181113


seorrow cas. _HAC RF EMISSIONS TEST REPORT                                                           Report No. : HA890514—05A
  6. Measurement System Specification

         Remote Control Box                         PC




          Signal Lamps                                                                     Electo—Ortical Commerter (E0C)
           <tlk»
                                                                                                             oae

                                                                                           (Ost. Ling
                                              Measurement Server
                                                                                                          E—feld ortfeld Probe

           Light Beam                                                                                                Device Under Test
                                                                  2x Serial +                                =
                                                                  Digtal ¥O
                                                                                           Phantom~—
                                                                                                                   I—Device Holder
                                                                                                                   —




       Teach Pendant
        t——GI                                  Robot Controller

         DO




                                                     Fig 5.1 System Configurations


  6.1 E—Field Probe System
  E—Field Probe Specification
  <ER3DV6>
  Construction                One dipole parallel, two dipoles normal to probe axis
                              Built—in shielding against static charges
  Calibration                 In air from 100 MHz to 3.0 GHz
                              (absolute accuracy +6.0%, k=2)
  efEcsy                      100 MHz to 6 GHz;
                              Linearity: + 2.0 dB (100 MHz to 3 GHz)
  Directivity                 + 0.2 dB in air (rotation around probe axis)
                              + 0.4 dB in air (rotation normal to probe axis)
  Dynamic Range               2 V/m to 1000 V/m
                              (M3 or better device readings fall well below diode
                              compression point)
  Linearity                   + 0.2 dB
  Dimensions                  Overall length: 330 mm (Tip: 16 mm)
                              Tip diameter: 8 mm (Body: 12 mm)
                              Distance from probe tip to dipole centers: 2.5 mm       Fig 5.2     Photo of E—field Probe
  Probe Tip Description:
  HAC field measurements take place in the close near field with high gradients. Increasing the measuring distance from the
  source will generally decrease the measured field values (in case of the validation dipole approx. 109&per mm}.




  TEL : 886—3—327—3456                                                                                       Page : 7 of 18
  FAX : 886—3—328—4978                                                                            Issued Date : Jul. 09, 2019
  Form version: 181113


seorton cas. _HAC RF EMISSIONS TEST REPORT                                                       Report No. : HA890514—05A
  6.2 Data Storage and Evaluation

  The DASY software stores the assessed data from the data acquisition electronics as raw data (in microvolt
  readings from the probe sensors), together with all the necessary software parameters for the data evaluation
  {probe calibration data, and device frequency and modulation data) in measurement files.


         Probe parameters :          — Sensitivity                       NOFM;: &ip; Aits Siz
                                     — Conversion factor                 ConvF;
                                     — Diode compression point           dep;
         Device parameters :         — Frequency                         f
                                     — Crest factor                      cf
         Media parameters :          — Conductivity
                                     — Density                           p

         The formula for each channel can be given as :

                                                                     ,   _of
                                                      Vi:Ui+Ui W
                                                                                i

         with   V; = compensated signal of channel i, (i= x, y, z)
                U; = input signal of channel i, (i =x, y, z)
                cf = crest factor of exciting field (DASY parameter)
                dep; = diode compression point (DASY parameter)



         From the compensated input signals, the primary field data for each channel can be evaluated :

                                                                                    V
                                              E—field Probes : E; =
                                                                         Normp—ConvF


         with   V; = compensated signal of channel i, (i= x, y, z)
                Norm; = sensor sensitivity of channel i, (i=x, y, z), pV/(V/m)2 for E—field Probes
                ConvF = sensitivity enhancement in solution
                f = carrier frequency [GHz]
                E; = electric field strength of channel i in V/m



         The RSS value of the field components gives the total field strength (Hermitian magnitude) :


                                                     Erop =   [EZ + Ef + E2

         The primary field data are used to calculate the derived field units.




  TEL : 886—3—327—3456                                                                                 Page : 8 of 18
  FAX : 886—3—328—4978                                                                          Issued Date : Jul. 09, 2019
  Form version: 181113


         HAC RF EMISSIONS TEST REPORT                                                 Report No. : HA890514-05A
7. RF Emissions Test Procedure
Referenced from ANSI C63.19 -2011 section 5.5.1
a. Confirm the proper operation of the field probe, probe measurement system, and other instrumentation
   and the positioning system.
b. Position the WD in its intended test position.
c. Set the WD to transmit a fixed and repeatable combination of signal power and modulation characteristic
   that is representative of the worst case (highest interference potential) encountered in normal use.
   Transiently occurring start-up, changeover, or termination conditions, or other operations likely to occur
   less than 1% of the time during normal operation, may be excluded from consideration.
d. The center sub-grid shall be centered on the T-Coil mode perpendicular measurement point or the
   acoustic output, as appropriate. Locate the field probe at the initial test position in the 50 mm by 50 mm
   grid, which is contained in the measurement plane, refer to illustrated in Figure 8.2. If the field alignment
   method is used, align the probe for maximum field reception.
e. Record the reading at the output of the measurement system.
f. Scan the entire 50 mm by 50 mm region in equality spaced increments and record the reading at each
   measurement point, The distance between measurement points shall be sufficient to assure the
   identification of the maximum reading.
g. Identify the five contiguous sub-grids around the center sub-grid whose maximum reading is the lowest of
   all available choices. This eliminates the three sub-grids with the maximum readings. Thus, the six areas
   to be used to determine the WD's highest emissions are identified.
h. Identify the maximum reading within the non-excluded sub-grids identified in step g).
i. Indirect measurement method
j. The RF audio interference level in dB (V/m) is obtained by adding the MIF (in dB) to the maximum
   steady-state rms field-strength reading, in dB (V/m)
k. Compare this RF audio interference level with the categories in ANSI C63.19-2011 clause 8 and record
   the resulting WD category rating.
l. For the T-Coil perpendicular measurement location is ≥5.0 mm from the center of the acoustic output,
   then two different 50 mm by 50 mm areas may need to be scanned, the first for the microphone mode
   assessment and the second for the T-Coil assessment.
m. The second for the T-Coil assessment, with the grid shifted so that it is centered on the perpendicular
   measurement point. Record the WD category rating.




TEL : 886-3-327-3456                                                                       Page : 9 of 18
FAX : 886-3-328-4978                                                                Issued Date : Jul. 09, 2019
Form version: 181113


         HAC RF EMISSIONS TEST REPORT                          Report No. : HA890514-05A




                         Figure 8.1 RF Emissions Flow Chart




TEL : 886-3-327-3456                                                 Page : 10 of 18
FAX : 886-3-328-4978                                          Issued Date : Jul. 09, 2019
Form version: 181113


         HAC RF EMISSIONS TEST REPORT                                           Report No. : HA890514-05A




                       Fig 8.2 EUT reference and plane for HAC RF emission measurements




                                     Fig. 8.3 Gauge block with E-field probe




TEL : 886-3-327-3456                                                                  Page : 11 of 18
FAX : 886-3-328-4978                                                           Issued Date : Jul. 09, 2019
Form version: 181113


           HAC RF EMISSIONS TEST REPORT                                               Report No. : HA890514-05A
8. Test Equipment List
                                                                                              Calibration
 Manufacturer              Name of Equipment           Type/Model   Serial Number
                                                                                      Last Cal.        Due Date
   SPEAG                1880MHz Calibration Dipole     CD1880V3         1038        Sep. 19, 2018    Sep. 18, 2019
   SPEAG                  Isotropic E-Field Probe       EF3DV3          4047        Jan. 30, 2019    Jan. 29, 2020
   SPEAG                Data Acquisition Electronics     DAE4           854         May. 21, 2019    May. 20, 2020
  RCPTWN                       Thermometer               HTC-1        TM560-2       Nov. 12, 2018    Nov. 11, 2019
   SPEAG                    Test Arch Phantom             N/A           N/A             NCR                 NCR
   SPEAG                     Phone Positioner             N/A           N/A             NCR                 NCR
    Anritsu                    Power Meter              ML2495A       1218006       Oct. 08, 2018    Oct. 07, 2019
    Anritsu                   Power Sensor              MA2411B       1207363       Oct. 08, 2018    Oct. 07, 2019
    Anritsu                  Signal Generator          MG3710A       6201502524     Dec. 11, 2018    Dec. 10, 2019
     R&S                       Base Station             CMW500         115793       Jun. 04, 2019    Jun. 03, 2020
     ATM                 Dual Directional Coupler      C122H-10     P610410z-02         NCR                 NCR
    Woken                       Attenuator             WK0602-XX        N/A             NCR                 NCR
 Mini-Circuits                Power Amplifier           ZVE-8G+      070501814      Oct. 08, 2018    Oct. 07, 2019
  Mini-Circuits              Power Amplifier           ZHL-42W+        15542        Aug. 09, 2018    Aug. 08, 2019
Note:
1. NCR: “No-Calibration Required”




TEL : 886-3-327-3456                                                                       Page : 12 of 18
FAX : 886-3-328-4978                                                                Issued Date : Jul. 09, 2019
Form version: 181113


            HAC RF EMISSIONS TEST REPORT                                                   Report No. : HA890514-05A
9. Measurement System Validation
Each DASY system is equipped with one or more system validation kits. These units, together with the predefined
measurement procedures within the DASY software, enable the user to conduct the system performance check and
system validation. System validation kit includes a dipole, tripod holder to fix it underneath the test Arch and a
corresponding distance holder.
The system performance check verifies that the system operates within its specifications. System and operator
errors can be detected and corrected. It is recommended that the system performance check be performed prior to
any usage of the system in order to guarantee reproducible results. The system performance check uses normal
HAC measurements in a simplified setup with a well characterized source. This setup was selected to give a high
sensitivity to all parameters that might fail or vary over time. The system check does not intend to replace the
calibration of the components, but indicates situations where the system uncertainty is exceeded due to drift or
failure.

<Test Setup>
1.   In the simplified setup for system evaluation, the EUT is replaced by a calibrated dipole and the power source is
     replaced by a continuous wave which comes from a signal generator.
2.   The center point of the probe element(s) is 15mm from the closest surface of the dipole elements.
3.   The calibrated dipole must be placed beneath the arch phantom. The equipment setup is shown below:
4.   The output power on dipole port must be calibrated to 20dBm (100mW) before dipole is connected.




                                                 Fig. 7.1 Setup Diagram

<Validation Results>
Comparing to the original E-field value provided by SPEAG, the verification data should be within its specification of
25 %. Table 6.1 shows the target value and measured value. The table below indicates the system performance
check can meet the variation criterion and the plots can be referred to appendix A of this report.
Deviation = ((Average E-field Value) - (Target value)) / (Target value) * 100%

                                                                             Average
Frequency Input Power        Target Value     E-Field 1       E-Field 2                    Deviation
                                                                              Value                          Date
  (MHz)      (dBm)              (V/m)           (V/m)           (V/m)                        (%)
                                                                              (V/m)
     1880          20             89.5          88.18          86.98          87.58          -2.15       Jun 12, 2019




TEL : 886-3-327-3456                                                                            Page : 13 of 18
FAX : 886-3-328-4978                                                                     Issued Date : Jul. 09, 2019
Form version: 181113


         HAC RF EMISSIONS TEST REPORT                                                     Report No. : HA890514-05A
10. Modulation Interference Factor
The HAC Standard ANSI C63.19-2011 defines a new scaling using the Modulation Interference Factor (MIF).
For any specific fixed and repeatable modulated signal, a modulation interference factor (MIF, expressed in dB)
may be developed that relates its interference potential to its steady-state rms signal level or average power level.
This factor is a function only of the audio-frequency amplitude modulation characteristics of the signal and is the
same for field-strength and conducted power measurements. It is important to emphasize that the MIF is valid only
for a specific repeatable audio-frequency amplitude modulation characteristic. Any change in modulation
characteristic requires determination and application of a new MIF
The Modulation Interference factor (MIF, in dB) is added to the measured average E-field (in dBV/m) and converts it
to the RF Audio Interference level (in dBV/m). This level considers the audible amplitude modulation components in
the RF E-field. CW fields without amplitude modulation are assumed to not interfere with the hearing aid electronics.
Modulations without time slots and low fluctuations at low frequencies have low MIF values, TDMA modulations
with narrow transmission and repetition rates of few 100 Hz have high MIF values and give similar classifications as
ANSI C63.19-2011.
ER3D, EF3D and EU2D E-field probes have a bandwidth <10 kHz and can therefore not evaluate the RF envelope
in the full audio band. DASY52 is therefore using the indirect measurement method according to ANSI C63.19-2011
which is the primary method. These near field probes read the averaged E-field measurement. Especially for the
new high peak-to-average (PAR) signal types, the probes shall be linearized by PMR calibration in order to not
overestimate the field reading. Probe Modulation Response (PMR) calibration linearizes the probe response over
its dynamic range for specific modulations which are characterized by their UID and result in an uncertainty
specified in the probe calibration certificate. The MIF is characteristic for a given waveform envelope and can be
used as a constant conversion factor if the probe has been PMR calibrated.
The evaluation method for the MIF is defined in ANSI C63.19-2011 section D.7. An RMS demodulated RF signal is
fed to a spectral filter (similar to an A weighting filter) and forwarded to a temporal filter acting as a quasi-peak
detector. The averaged output of these filtering is scaled to a 1 kHz 80% AM signal as reference. MIF measurement
requires additional instrumentation and is not well suited for evaluation by the end user with reasonable uncertainty.
It may alliteratively be determined through analysis and simulation, because it is constant and characteristic for a
communication signal. DASY52 uses well-defined signals for PMR calibration. The MIF of these signals has been
determined by simulation and it is automatically applied.
The MIF measurement uncertainty is estimated as follows, declared by HAC equipment provider SPEAG, for
modulation frequencies from slotted waveforms with fundamental frequency and at least 2 harmonics within 10 kHz:
1.    0.2 dB for MIF: -7 to +5 dB
2.    0.5 dB for MIF: -13 to +11 dB
3.    1 dB for MIF: > -20 dB
MIF values applied in this test report were provided by the HAC equipment provider of SPEAG, and the worst
values for all air interface are listed below to be determine the Low-power Exemption.

                       UID                    Communication System Name                    MIF(dB)
                       10170             LTE-FDD(SC-FDMA,1RB,20MHz,16-QAM)                  -9.76
                       10172            LTE-TDD (SC-FDMA, 1 RB, 20 MHz, QPSK)               -1.62
                       10173           LTE-TDD (SC-FDMA, 1 RB, 20 MHz, 16-QAM)              -1.44
                       10174           LTE-TDD (SC-FDMA, 1 RB, 20 MHz, 64-QAM)              -1.54
                       10077         IEEE 802.11g WiFi 2.4 GHz (DSSS/OFDM, 54 Mbps)         0.12




TEL : 886-3-327-3456                                                                           Page : 14 of 18
FAX : 886-3-328-4978                                                                    Issued Date : Jul. 09, 2019
Form version: 181113


seorron cas. _HAC RF EMISSIONS TEST REPORT                                                   Report No. : HA890514—05A
  11. Low—power Exemption for Mobile 5G MOD




  <Low Power Exemption>
                                    Max Average
                m                                          Worst Case           oo                         C63.19 test
              Air Interface         Antenna Input                                                               —
                                                            MIF (dB)            sc                           Ees
                                     Power (dBm}
               LTE— FDD

  General Note:
  1. According to ANSI C63.19 201 1—version, for the air interface technology of a device is exempt from testing
      when its average antenna input power plus its MIF is <17 dBm for any of its operating modes.
  2. For LTE B48 maximum power is 23dBm, according to ANSI €63.19 2011 —version, for the air interface
      technology of a device is exempt from testing whose peak antenna input power, averaged over intervals <50 pis,
      is s23 dBm. An RF air interface technology that is exempted from testing shall be rated as M4
  3. HAC RF rating is M4 for the air interface which meets the low power exemption.




  12. Spot check RF Emission for Mobile cell phone
  General:
  1.       This result is to verify the IHDTSEWB1 HAC performanceis not degraded when 5G Mod is attached on. The
           worst case from the IHDTSGWB1 HAC report (Sporton HA733129—02A, Rev: 01, Date: 06/23/2017) was
           selected to test, and HAC rating is not changed.


                                                          Average                                Ece
  Plot          P                                         Pucaucl                  Cl                      Mak     E—Field
  No.         Air Interface                   Channel      hm                     (dBV/im)     FCC(I(\jIIg)Ilmlt   Ee
                                                         Power (dBm)
       1       GSM1900         GSM Voice           810      29.41       3.63       30.06            4.94             M3


  Remark:
  1.       The HAC measurement system applies MIF value onto the measured RMS E—field, which is indirect method in
           ANSI C63.19 2011 version, and reports the RF audio interference level.
  2.       Phone Condition: Mute on; Backlight off; Max Volume


           Test Engineer : Bevis Chang.




  TEL : 886—3—327—3456                                                                            Page : 15 of 18
  FAX : 886—3—328—4978                                                                     Issued Date : Jul. 09, 2019
  Form version: 181113


         HAC RF EMISSIONS TEST REPORT                                                  Report No. : HA890514-05A



13. Uncertainty Assessment
The component of uncertainly may generally be categorized according to the methods used to evaluate them.
The evaluation of uncertainly by the statistical analysis of a series of observations is termed a Type A
evaluation of uncertainty. The evaluation of uncertainty by means other than the statistical analysis of a series
of observation is termed a Type B evaluation of uncertainty. Each component of uncertainty, however
evaluated, is represented by an estimated standard deviation, termed standard uncertainty, which is
determined by the positive square root of the estimated variance.


The combined standard uncertainty of the measurement result represents the estimated standard deviation of
the result. It is obtained by combining the individual standard uncertainties of both Type A and Type B
evaluation using the usual “root-sum-squares” (RSS) methods of combining standard deviations by taking the
positive square root of the estimated variances. Expanded uncertainty is a measure of uncertainty that
defines an interval about the measurement result within which the measured value is confidently believed to
lie. It is obtained by multiplying the combined standard uncertainty by a coverage factor. For purpose of this
document, a coverage factor two is used, which corresponds to confidence interval of about 95 %. The DASY
uncertainty Budget is showed in Table 12.1.


The judgment of conformity in the report is based on the measurement results excluding the measurement
uncertainty.




TEL : 886-3-327-3456                                                                        Page : 16 of 18
FAX : 886-3-328-4978                                                                 Issued Date : Jul. 09, 2019
Form version: 181113


seorrow cas. _HAC RF EMISSIONS TEST REPORT                                                        Report No. : HA890514—05A




  Probe Calibration                       .           Normal                                           £5.1 %
  Axial Isot                              .         Rectangular                                        42.7 %
  Sensor Displacement                               Rectangular                                        +9.5 %
  Boundary Effects                        .         Rectangular                                        £1.4%
  Phantom Boundary Effects                .         Rectangular                                        441 %
  Linearity                               .         Rectangular                                        +2.7 %
  Scaling    with PMR Calibration                   Rectangular                                        £5.77 %
  System Detection Limit                  .         Rectangular                                        +0.6 %
  Readout Electronics                     .           Normal                                           +0.3 %
  Response Time                           .         Rectangular                                        +0.5 %
  Integration Time                        .         Rectangular                                        £1.5%
  RF Ambient Conditions                   .         Rectangular                                        £1.7 %
  RF Reflections                                    Rectangular                                        +6.9 %
  Probe Positioner                        .         Rectangular                                        + 0.7 %
  Probe Positionin:                       .         Rectangular                                        42.7 %
  Extrap. and Interpolation               .         Rectangular                                        +0.6 %


  Device Positioning Vertical             .         Rectangular                                        +2.7 %
  Device Positioning Lateral              —         Rectangular                                        +0.6 %
  Device Holder and Phantom               .         Rectangular                                        41.4%
  Power Drift                             —         Rectangular                                        +2.9 %


  Phantom Thickness                       .         Rectangular                                        £1.4%
  Combined Standard Uncertainty                                                                       +16.30%
  Coverage Factor for 95 %                                                                               K=2




                              Table 12.1 Uncertainty Budget of HAC free field assessment
            Remark:
            Worst—Case uncertainty budget for HAC free field assessment according to ANSIC63.19 [1], [2]. The budgetis
            valid for the frequency range 700 MHz — 3 GHz and represents a worst case analysis.




  TEL : 886—3—327—3456                                                                               Page : 17 of 18
  FAX : 886—3—328—4978                                                                        Issued Date : Jul. 09, 2019
  Form version: 181113


         HAC RF EMISSIONS TEST REPORT                                            Report No. : HA890514-05A

14. References
 [1]   ANSI C63.19-2011, “American National Standard for Methods of Measurement of Compatibility
       between Wireless Communications Devices and Hearing Aids”, 27 May 2011.
 [2]   FCC KDB 285076 D01v05, “Equipment Authorization Guidance for Hearing Aid Compatibility”, Sep
       2017
 [3]   FCC KDB 285076 D02v03, “Guidance for performing T-Coil tests for air interfaces supporting voice
       over IP (e.g., LTE and WiFi) to support CMRS based telephone services”, Sep 2017
 [4]   FCC KDB 285076 D03v01, “Hearing aid compatibility frequently asked questions”, Sep 2017
 [5]   SPEAG DASY System Handbook




TEL : 886-3-327-3456                                                                  Page : 18 of 18
FAX : 886-3-328-4978                                                           Issued Date : Jul. 09, 2019
Form version: 181113



Document Created: 2019-07-09 19:22:16
Document Modified: 2019-07-09 19:22:16

© 2024 FCC.report