Power Density_Appendix C

FCC ID: IHDT56XL1

RF Exposure Info

Download: PDF
FCCID_4364268

Calibration Laboratory of
Schmid & Partner
                                                                                                                s     Schweizerischer Kalibrierdienst
                                                                                                                C     Service suisse d'etalonnage
 Engineering AG                                                                                                       Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                    s     Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                             Accreditation No.:     SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client          Sporton                                                                            Certificate No:    5G-Veri30-1007_Apr_
                                                                                                                                        19_~

I   CALIBRATION CERTIFICATE
    Object                                    5G Verification $0urce 30.GHz - SN: 1007


    Calibration procedure(s)                  QA CAL~45.v2
                                              Calibration procedure for sources in air above 6 GHz

                                         I
    Calibration date:                     April 2{ 2019

    This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
    The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


    All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.

    Calibration Equipment used (M&TE critical for calibration)
    Primary Standards                         ID#                     Cal Date (Certificate No.)                          Scheduled Calibration
    Reference Probe EUmmWV3                   SN: 9374                31-Dec-18 (No. EUmmWV3-9374_Dec18)                  Dec-19
    DAE4                                      SN: 1215                22-Feb-19 (No. DAE4-1215_Feb19)                     Feb-20



    Secondary Standards                       ID#                     Check Date (in house)                               Scheduled Check




                                              Name                                 Function                                Signature
    Calibrated by:                            Leif Klysner                         Laboratory Techntdan


    Approved by:
                                          I
                                                                                                                        't:ef~- 1
                                          I.._K
                                              _a~tj-·a_P
                                                       _o_k_o_v_ic_··~ - - - - ~ - -T-ec-h~n-ica
                                                                                              ~ I~M
                                                                                                  ~a-n-ag~e-r- - - - ~ _ _ 5      · - - - - - - -i
                                                                                                                           _·_ · _-


                                                                                                                          Issued: April 24, 2019
    This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: 5G-Veri30-1007_Apr19                           Page 1 of 4


Calibration Laboratory of                                                           S    Schweizerischer Kalibrierdienst
Schmid & Partner                                                                         Service suisse d'etalonnage
                                                                                    C
 Engineering AG                                                                          Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                        s    Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                  Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Glossary

cw                           Continuous wave

Calibration is Performed According to the Following Standards

    •    Internal procedure QA CAL-45-5Gsources
    •    IEC TR 63170 ED1, "Measurement procedure for the evaluation of power density related to
         human exposure to radio frequency fields from wireless communication devices operating
         between 6 GHz and 100 GHz", January 2018
Methods Applied and Interpretation of Parameters

    •    Coordinate System: z-axis in the waveguide horn boresight, x-axis is in the direction of the
         E-field, y-axis normal to the others in the field scanning plane parallel to the horn flare and
         horn flange.
    •    Measurement Conditions: (1) 10 GHz: The forward power to the horn antenna is measured
         prior and after the measurement with a power sensor. During the measurements, the horn
         is directly connected to the cable taking into account the 0.2d8 horn loss. (2) 30, 60 and 90
         GHz: The verification sources are switched on for at least 30 minutes. Absorbers are used
         around the probe cub and at the ceiling to minimize reflections.
    •    Horn Positioning: The waveguide horn is mounted vertically on the flange of the waveguide
         source to allow vertical positioning of the EUmmW probe during the scan. The plane is
         parallel to the phantom surface. Probe distance is verified using mechanical gauges
         positioned on the flare of the horn.
    •    E- field distribution: E field is measured in two x-y-plane (10mm, 10mm + 'A/4) with a
         vectorial E-field probe. The E-field value stated as calibration value represents the E-field-
         maxima and the averaged ( 1cm 2 and 4cm 2 ) power density values at 10mm in front of the
         horn.
    •    Field polarization: Above the open horn, linear polarization of the field is expected. This is
         verified graphically in the field representation.
Calibrated Quantity

    •    Local peak E-field (V/m) and peak values of the total and normal component of the poynting
         vector IRe{S}I and n.Re{S} averaged over the surface area of 1 cm 2 (pStotavg1cm 2 and
         pSnavg1 cm 2 ) and 4cm 2 (pStotavg4cm 2 and pSnavg4cm 2 ) at the nominal operational
         frequency of the verification source.



 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: 5G-Veri30-1007_ Apr19                  Page 2 of 4


Measurement Conditions
       DASY system configuration, as far as not given on page 1.
         DASY Version                                   cDASY6 Module mmWave                             V1.6
         Phantom                                                 5G Phantom
         Distance Horn Aperture - plane                             10 mm
         XY Scan Resolution                                     dx, dy = 2.5 mm
         Number of measured planes                        2 (10mm, 10mm + 'A/4)
         Frequency                                            30 GHz± 10 MHz




Calibration Parameters, 30 GHz

         Distance Horn Aperture      Prad1      Max E-field       Uncertainty        Avg Power Density          Uncertainty
         to Measured Plane           (mW)         (V/m)                =
                                                                    (k 2)             n.Re{S}, 1Re{S}1              =
                                                                                                                  (k 2)
                                                                                          (W/m2)
                                                                                    1 cm 2       4cm 2
                  10mm                 32.9         136             1.27 dB       43.1, 43.4   37.4, 37.9        1.28 dB




1
    derived from far-field data

Certificate No: 5G-Veri30-1007_Apr19              Page 3 of 4


DASY Report

Measurement Report for SG Verification Source 30 GHz, UID O -, Channel 30000 (30000.0MHz)

Device under Test Properties
Na_me, Manufacturer                 Dimensions [mm]                     IMEI                                   DUTType
5G Verification Source 30 GHz       100.0 X 100.0 X 100.0               SN: 1007

Exposure Conditions
Phantom Section             Position, Test Distance   Band                 Group,                           Frequency [MHz],           Conversion Factor
                            [mm]                                                                            Channel Number
5G-                         5.55 mm                   Validation band      cw                               30000.0,                   1.0
                                                                                                            30000



Hardware Setup
Phantom                               Medium                                    Probe, Calibratic,_n Date                      DAE, Calibration Date
5G Phantom                            Air                                       EUmmWV3 - SN9374, 2018-12-31                   DAE4 Sn 1215, 2019-02-22



Scan Setup                                                                      Measurement Results
                                                                  SG Scan                                                                              SG Scan
 Grid Extents [mm]                                             60.0x 60.0          Date                                                      2019-04-24, 12:10
 Grid Steps [lambda]                                           0.25 X 0.25         Avg. Area [cm 2]                                                       1.00
 Sensor Surface [mm]                                                  5.55         pS101 avg [W/m 2]                                                      43.4
 MAIA                                                        MAIA not used         pSn avg [W /m 2]                                                       43.1
                                                                                   Epe ak [V/m]                                                             136
                                                                                   Power Drift [dB]                                                        -0.04




Certificate No: 5G-Veri30-1007_Apr19                         Page 4 of 4


probabilty aregiven on the following pages and are partof the certificate.

          environment temperature(22+ 3)°Candhumidity < 70%.




EUmmWV3 — SN: 9413                          February13,2019



DASY — Parameters of Probe: EUmmWV3 — SN:9413


EUmmWV3 — SN: 9413                                February 13,2019

DASY — Parameters of Probe: EUmmWV3— SN:9413
       I



                       aB   aBvpy   ~   db   my




        EUmmWV3 —SN: 9413
                                                                                     |
I
    &      —:'I ""Tlas
      o w eo0               v     _                                                  |
    —       —               Deviation from Isotropy in Air
                                                 f=30GHz
                                                                           obeaxis
                                30GHz: 30 isotropy, E—fieldparallel topr


EUmmWV3 — SN: 9413                            February 13, 2019

Appendix: Modulation Calibration Parameters


EUmmWV3— SN: 9413   February 13, 2019


EUmmWV3 — SN: 9413    February 13, 2019

               IEEE


6102 ‘g1 Arerugay   ELt6 °NS — eamuung




                                                                    61g4ELve—EAMuwung ‘on ereoymeq




                                              E3

                    doi—sk     TN ‘NVD—9 ‘2HW 02

                    agi317     TN ‘WYD—9% ‘2HW 02           %004
                    adi—347     TN »SdD ‘ZHN 02 ‘8H            1‘

                    aor317    TN ‘NYD—49           5L ‘gH

                    gaisi7    TN ‘WVD—9% ‘ZHW St               .

                    q317        TN M8dD ‘ZHW St ‘HH %004
                    agi—347   TN ‘NVD—p9 ‘ZHW 0t ‘@i %00L

                    agi—317   N ‘W¥D—9% ‘zHM 0t ‘SH %004
                                                                     2
                   adi—317      In         ‘ZHW OL ‘8H %004
                                                                     L
                   gais17      N ‘WVO—p9 ‘2HM S ‘@d %004
                                                            P
                   qo—317         ‘NVD—91 ‘ZHW ‘Si %004 ‘VAC4—08)                p
                                                                     Iv
                   agisi7        TN ‘XSAD ‘ZHW S ‘SH %004 ‘VWG:—O8) adi—317
                                                            L¥
                   adi—317     1N ‘WVD—49 ‘ZHW & ‘g%004 ‘NNGS—O8)     sann
                                                            L¥
                   adi—317     TN ‘WvD—91 ‘zHn 6 ‘gs   1 ‘w€3—08) agi—31:
                                                                     V
                   ddi—317       IN HSdD ‘ZHW & ‘SH %004                   agi—s7,
                                                                    829
                   aai317     TN WNYD—P9 ‘ZHW $‘1 ‘@ %004           adi—31"
                                                             L
                   ddi—317    TN ‘AYD—91 ‘ZHW p‘L ‘g %004 ‘VNGI—O8) aqu—

                   aarsi7      TN MSdD ‘ZHW $‘t ‘gs %004 ‘VWGS—O8) aal—
                                                             L
            198    dgais17     In ‘WvD—b9 ‘zHW 02 ‘SH %08 ‘vWG4—08) adi—317
                                                                                                L
                                                          68 2¢
   967      188    agi—347     In ‘Wyb—al ‘zHW 0z ‘gH %0s ‘vNa4—08) adi— 1
                                                                                            SGrOL
   96r      w22    aai—311
                                                                     T
                                 1N 38g0 ‘zHM 02 ‘8x %09 ‘vNaq—08) agi—317                  P6pOL
   967      99B                                              Lt
                   ddi—317     TN ‘WYO—p9 ‘zHW St ‘8H %05 ‘vAa4—08) adi—317
                                                                                            £6r0L
   967      L8                                             82¥
                   adi—347     1N ‘WYD—91 ‘ZHM St ‘dH %05 ‘WHO4—08) adi—317
                                                                                            26pOL
6107 ‘¢1 Aerigey
                                                                                ELP6 NS — eAmwung


EUmmWV3 — SN: 9413                                                        February 13, 2019




                                                   Mops,       duty

                     19 WiFi 2.4 GHz (DSSS—OFDM, 12 Mbps, 99pc duty

                                                 18 Mbps,          duty

                                                 24                duty



                                                 48         99pc
                            2.4 GHz (DSSS—OFDM, 54 Mbps, 9pc duty


EUmmWV3 — SN: 9413   February 13, 2019

                      76     &




Calibration Laboratory of
Schmid & Partner
                                                                                                           s
                                                                                                           C
                                                                                                                    Schweizerischer Kalibrierdienst
                                                                                                                    Service suisse d'etalonnage
 Engineering AG                                                                                                     Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                               s        Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                             Accreditation No.:      SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       Sporton                                                                            Certificate No:      DAE4-853_Jul18

CALIBRATION CERTIFICATE                                                                                                                               I

 Object                                DAE4 - SD 000 D04 BM - SN: 853


 Calibration procedure(s)              QA CAL-06.v29
                                       Calibration procedure for the data acquisition electronics (DAE)



 Calibration date:                     July 24, 2018




 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


  Primary Standards                                                Cal Date (Certificate No.)                            Scheduled Calibration
  Keithley Multimeter Type 2001        I SN: 0810278               31-Aug-17 (No:21092)                                  Aug-18


  Secondary Standards                    ID#                       Check Date (in house)                                  Scheduled Check
  Auto DAE Calibration Unit              SE UWS 053 AA 1001        04-Jan-18 (in house check)                            In house check: Jan-19
  Calibrator Box V2.1                    SE UMS 006 AA 1002        04-Jan-18 (in house check)                            In house check: Jan-19




                                         Name                                   Function                                  Signature

  Calibrated by:                        Dominique Steffen                       Laboratory Technician




  Approved by:                           Sven KOhn                              Deputy Manager



                                                                                                                          Issued: July 24, 2018
  This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




 Certificate No: DAE4-853_Jul18                                        Page 1 of 5


Calibration Laboratory of                                                      S   Schweizerischer Kalibrierdienst
Schmid & Partner                                                                   Service suisse d'etalonnage
                                                                               C   Servizio svizzero di taratura
 Engineering AG
Zeughausstrasse 43, 8004 Zurich, Switzerland                                   s   Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                            Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates



Glossary
DAE                          data acquisition electronics
Connector angle              information used in DASY system to align probe sensor X to the robot
                             coordinate system.

Methods Applied and Interpretation of Parameters
  •   DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
     comparison with a calibrated instrument traceable to national standards. The figure given
     corresponds to the full scale range of the voltmeter in the respective range.
     •   Connector angle: The angle of the connector is assessed measuring the angle
         mechanically by a tool inserted. Uncertainty is not required.
     •   The following parameters as documented in the Appendix contain technical information as a
         result from the performance test and require no uncertainty.
         •     DC Voltage Measurement Linearity: Verification of the Linearity at + 10% and -10% of
               the nominal calibration voltage. Influence of offset voltage is included in this
               measurement.
         •     Common mode sensitivity: Influence of a positive or negative common mode voltage on
               the differential measurement.
          •    Channel separation: Influence of a voltage on the neighbor channels not subject to an
               input voltage.
          •    AD Converter Values with inputs shorted: Values on the internal AD converter
               corresponding to zero input voltage
          •    Input Offset Measurement Output voltage and statistical results over a large number of
               zero voltage measurements.
          •    Input Offset Current: Typical value for information; Maximum channel input offset
               current, not considering the input resistance.
          •    Input resistance: Typical value for information: DAE input resistance at the connector,
               during internal auto-zeroing and during measurement.
          •     Low Battery Alarm Voltage: Typical value for information. Below this voltage, a battery
                alarm signal is generated.
          •     Power consumption: Typical value for information. Supply currents in various operating
                modes.




 Certificate No: DAE4-853_Jul18                                  Page 2 of 5


DC Voltage Measurement
   AID - Converter Resolution nominal
       High Range:          1LSB =     6.1µV,        full range= -100 ... +300 mV
       LowRange:            1LSB=      61nV,         fullrange= -1 .......+3mV
   DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

     Calibration Factors              X                         y                         z
     High Range             402.653 ± 0.02% (k=2)    403.319   ± 0.02% (k=2)   403.479   ± 0.02% (k=2)
     Low Range              3.95632 ± 1 .50% (k=2)   3.96571   ± 1.50% (k=2)   3.96767 ± 1.50% (k=2)



Connector Angle

     Connector Angle to be used in DASY system                                     133.5 ° ± 1 °




Certificate No: DAE4-853_Jul18                       Page 3 of 5


Appendix (Additional assessments outside the scope of SCS0108)

1. DCV oltaae Lmearitv
    High Range                                 Reading (µ.VJ        Difference (µVJ             Error (%J

    ChannelX         + Input                    199996.99                    1.42                0.00

    ChannelX         + Input                     20003.62                    1.84                O.Q1

    ChannelX         - Input                    -20000.02                    1.12               -0.01

    Channel V        + Input                    199996.86                    1.15                0.00

    ChannelV         + Input                     20003.13                    1.35                0.01

    ChannelV         - Input                    -20002.42                   -1.42                0.01

     Channel Z       + Input                    199995.34                   -0.26               -0.00

     ChannelZ        + Input                     20000.34                   -1.41                -0.01

     Channel Z       - Input                     -20002.42                  -1.26                O.Q1


     Low Range                                 Reading (µVJ          Difference (µ V)           Error(%)

     Channel X       + Input                      2002.06                    0.81                0.04

     Channel X       + Input                      201.69                     0.01                0.00

     ChannelX        - Input                      -197.81                    0.40                -0.20

     ChannelV         + Input                     2001.19                    -0.07               -0.00

     Channel Y        + Input                     201.32                     -0.28               -0.14

     ChannelY         - Input                     -198.71                    -0.48               0.24

     ChannelZ         + Input                     2001.01                    -0.10               -0.01

     ChannelZ         + Input                     200.73                     -0.78               -0.39

     Channel Z        - Input                     -198.74                    -0.39               0.19



2. Common mode sensitivity
   DASY measurement parameters· Auto Zero Time· 3 sec· Measuring time· 3 sec
                                                             '
                        Common mode                        High Range                         Low Range
                        Input Voltage (mV)             Average Reading (µVJ              Average Reading (µV)

    ChannelX                            200                       -6.54                        -8.40

                                       -200                       10.04                        8.25

    Channel Y                           200                       4.94                         4.77

                                       -200                       -5.28                        -5.77

    Channel Z                           200                       1.16                         1.46

                                       - 200                      -3.62                        -3.50



3. Channel separation
    DASV measurement parameters: Auto Zero Time: 3 sec; Measurina time: 3 sec
                        Input Voltage (mVJ         Channel X (µV)          Channel Y (µVJ    Channel Z (µVJ

     Channel X                   200                         -                  8.01               2.30

     Channel Y                   200                    11.72                        -             8.82

     ChannelZ                    200                    14.69                   9.44                   -

Certificate No: DAE4-853_Jul18                               Page 4 of 5


4. AD-Converter Values with inputs shorted
   DASY measurement parameters· Auto Zero Time· 3 sec· Measuring time- 3 sec
                                                     '
                                            High Range (LSB)               Low Range (LSB)

    ChannelX                                                 16243                            16610

    Channel Y                                                16089                            16674

    Channel Z                                                16234                            15819



5. Input Offset Measurement
   DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
   Input 10MQ
                                                                                               Std. Deviation
                           Average (µV)         min. Offset (µV)      max. Offset (µV)
                                                                                                    (uV)
    Channel X                     0.29                -0.41                   1.44                   0.33

    Channel Y                     -0.17               -1.64                   0.77                    0.39

    ChannelZ                      0.76                -0.87                   2.49                    0.52



6. Input Offset Current
    Nominal Input circuitry offset current on all channels: <25fA


7. Input Resistance        (Tvpical values for information)
                                                   Zeroing (kOhm)                        Measuring (MOhm)

    ChannelX                                                200                                200

    Channel Y                                               200                                200

    Channel Z                                               200                                200



8. Low Batterv Alarm Voltaae              (Tvpical values for information)
    Typical values                                 Alarm Level (VDC)

    Supply(+ Vee)                                                                 +7.9

    Supply (- Vee)                                                                -7.6



9. Power Consumnt1on              (Tvpical values for information)
    Typical values                           Switched off (mA)       Stand by (mA)          Transmitting (mA)

     Supply(+ Vee)                                  +0.01                    +6                      +14

     Supply (- Vee)                                 -0.01                    -8                      -9




Certificate No: DAE4-853_Jul 18                             Page 5 of 5



Document Created: 2019-07-09 19:23:14