Exhibit 6F HAC RFE Report 2

FCC ID: IHDT56QA3

Test Report

Download: PDF
FCCID_2362827

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2014/6/18

HAC_E_Dipole_835_140618

DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
                    23.6

DASY5 Configuration
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2014/1/30;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1425; Calibrated: 2014/3/3
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.9 (7117)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 113.4 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 115.8 V/m
Average value of Total=(115.7+114.1) / 2 = 114.9 V/m

                                    PMF scaled E-field
                                     Grid 1 M4 Grid 2 M4 Grid 3 M4
                                     115.8 V/m 115.7 V/m 108.8 V/m
                                     Grid 4 M4 Grid 5 M4 Grid 6 M4
                                     71.86 V/m 71.86 V/m 67.67 V/m
                                     Grid 7 M4 Grid 8 M4 Grid 9 M4
                                     114.1 V/m 114.1 V/m 105.9 V/m
                                                   Cursor:
                                              Total = 115.8 V/m
                                               E Category: M4
                                           Location: 4, -69.5, 9.7 mm


0 dB = 115.8 V/m = 41.27 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab        Date: 2014/8/14

HAC_E_Dipole_835_140814

DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
                    23.6

DASY5 Configuration
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2014/1/30;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1338; Calibrated: 2013/11/5
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 106.3 V/m; Power Drift = -0.07 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 109.8 V/m
Average value of Total=(107.6+103.2) / 2 = 105.4 V/m

                                    PMF scaled E-field
                                     Grid 1 M4 Grid 2 M4 Grid 3 M4
                                     93.62 V/m 107.6 V/m 109.8 V/m
                                     Grid 4 M4 Grid 5 M4 Grid 6 M4
                                     59.07 V/m 64.73 V/m 65.85 V/m
                                     Grid 7 M4 Grid 8 M4 Grid 9 M4
                                     93.67 V/m 103.2 V/m 105.5 V/m
                                                   Cursor:
                                              Total = 109.8 V/m
                                               E Category: M4
                                           Location: -7, -74, 9.7 mm


0 dB = 109.8 V/m = 40.81 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab        Date: 2014/6/18

HAC_E_Dipole_1880_140618

DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
                    23.6

DASY5 Configuration
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2014/1/30;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1425; Calibrated: 2014/3/3
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.9 (7117)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 145.8 V/m; Power Drift = 0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 88.95 V/m
Average value of Total=(88.95+84.66) / 2 = 86.805 V/m

                                    PMF scaled E-field
                                     Grid 1 M3 Grid 2 M3 Grid 3 M3
                                     88.09 V/m 88.95 V/m 87.80 V/m
                                     Grid 4 M3 Grid 5 M3 Grid 6 M3
                                     68.63 V/m 69.09 V/m 67.83 V/m
                                     Grid 7 M3 Grid 8 M3 Grid 9 M3
                                     83.94 V/m 84.66 V/m 82.10 V/m
                                                   Cursor:
                                              Total = 88.95 V/m
                                               E Category: M3
                                            Location: 0, -31, 9.7 mm


0 dB = 88.95 V/m = 38.98 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab        Date: 2014/8/14

HAC_E_Dipole_1880_140814

DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
                    23.6

DASY5 Configuration
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2014/1/30;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1338; Calibrated: 2013/11/5
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 133.3 V/m; Power Drift = -0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 86.63 V/m
Average value of Total=(81.64+85.73) / 2 = 83.69 V/m

                                    PMF scaled E-field
                                     Grid 1 M3 Grid 2 M3 Grid 3 M3
                                     72.62 V/m 81.64 V/m 82.57 V/m
                                     Grid 4 M4 Grid 5 M3 Grid 6 M3
                                     61.60 V/m 65.58 V/m 66.03 V/m
                                     Grid 7 M3 Grid 8 M3 Grid 9 M3
                                     79.05 V/m 85.73 V/m 86.63 V/m
                                                   Cursor:
                                              Total = 86.63 V/m
                                               E Category: M3
                                            Location: -7, 33, 9.7 mm


0 dB = 86.63 V/m = 38.75 dBV/m



Document Created: 2014-08-15 17:13:03
Document Modified: 2014-08-15 17:13:03

© 2024 FCC.report