RF Exposure MPE

FCC ID: I88X550NHV2

RF Exposure Info

Download: PDF
FCCID_1010524

                                                              FCC ID. : I88X550NHV2
                                                          Report No.: TS08090052-EME
                                                                       Page 1 of 6




Maximum Permissible Exposure (MPE)
        Evaluation Report

               Report No.       : TS08090052-EME
               Model No.        : NBG-460NH, X-550NH,
                                  NBG-460N, X-550N
               Issued Date      : Sep. 19, 2008



Applicant:     ZyXEL Communications Corporation.
               6, Innovation Rd II, Science-Based Industrial Park,
               Hsinchu, Taiwan

Test Method/ FCC 1.1310 and Safety Cord 6
Standard:

Test By:       Intertek Testing Services Taiwan Ltd.
               No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li,
               Shiang-Shan District, Hsinchu City, Taiwan


This test report consists of 6 pages in total. It may be duplicated completely
for legal use with the allowance of the applicant. It shall not be reproduced
except in full, without the written approval of Intertek Laboratory. The test
result(s) in this report only applies to the tested sample(s).




  Report Engineer



   Sammi Liu
                                                     Reviewed By
  Project Engineer



    Rex Liao                                            Jimmie Liu


                                                                                                  FCC ID. : I88X550NHV2
                                                                                              Report No.: TS08090052-EME
                                                                                                           Page 2 of 6


                                                  Table of Contents

Summary of Tests ............................................................................................................. 3

1. Introduction .................................................................................................................. 4

2. RF Exposure Limit ....................................................................................................... 4

3. RF Exposure calculations ............................................................................................. 5

4. Test results .................................................................................................................... 6


                                                              FCC ID. : I88X550NHV2
                                                          Report No.: TS08090052-EME
                                                                       Page 3 of 6


Summary of Tests

MPE Evaluation meet FCC OET No. 65: 1997, IEEE C95.1-1999 and
IC Safety Code 6

      High-gain Wireless N Gigabit Router -Model: NBG-460NH
                      FCC ID: I88X550NHV2

       Test                           Reference                         Results
                    FCC Guidelines for Human Exposure IEEE C95.1
 MPE Evaluation                                                        Complies
                   and IC Safety Code 6

The customer confirmed the models listed as below are series model to model
NBG-460NH (EUT), the difference between main model and series model are listed as
below.

     Model Number                     Different
     NBG-460NH                        Collocated with 6dBi antenna
     X-550NH                          Same as NBG-460NH
     NBG-460N                         Collocated with 1.8dBi antenna
     X-550N                           Same as NBG-460N


                                                                  FCC ID. : I88X550NHV2
                                                              Report No.: TS08090052-EME
                                                                           Page 4 of 6

1. Introduction

The EUT operates in the 2.4GHz ISM band. Due to the EUT (include antenna) at its
normal operation distance is at least 20 cm from the human body, the EUT was defined
as a Mobile Device.


The reason to do the MPE Evaluation is to avoid the RF hazard to human body. The
maximum output power and gain of the antenna were used to calculate the limited
Power density (S) at 20cm distance away from the product. The limit for Maximum
Permissible Exposure (MPE) specified in FCC 1.1310 and Safety Cord 6 are followed.


According to 1.1307 (b)(1), systems operating under the provisions of this section shall
be operated in a manner that ensure that the public is not exposed to radio frequency
energy level in excess of the Commission’s guideline.



2. RF Exposure Limit

For FCC:
According to FCC 1.1310: The criteria listed in the following table shall be used to
evaluate the environmental impact of human exposure to radio-frequency (RF) radiation
as specified in 1.1307(b).

                   Limits for Maximum Permissible Exposure (MPE)

   Frequency       Electric Field Magnetic Field
                                                     Power Density       Average Time
     Range           Strength         Strength
                                                       (mW/cm2)           (minutes)
     (MHz)            (V/m)            (A/m)
                   (A) Limits for Occupational / Control Exposures
     30-300             61.4             0.163               1.0               6
   300-1500               -                 -              F/300               6
 1500-100,000             -                 -                5                 6
               (B) Limits for General Population / Uncontrolled Exposure
     30-300             27.5             0.073               0.2               30
   300-1500               -                 -              F/1500              30
 1500-100,000             -                 -                1.0               30

F= Frequency in MHz


                                                                   FCC ID. : I88X550NHV2
                                                               Report No.: TS08090052-EME
                                                                            Page 5 of 6

For IC:
Exposure Limits for Persons Not Classed As RF and Microwave Exposed Workers
(Including the General Public)

   Frequency       Electric Field   Magnetic Field
                                                        Power Density    Average Time
     Range         Strength; rms    Strength; rms
                                                           (W/m2)         (minutes)
     (MHz)             (V/m)            (A/m)
    0.003-1             280              2.19                  -               6
      1-10             280/f             2.19/f                -               6
     10-30              28               2.19/f                -               6
    30-300              28               0.073                2*               30
                              0.5                 0.5
   300-1500          1.585f           0.0042f               F/150              30
  1500-15000           61.4              0.163                10               30
 15000-150000          61.4              0.163                10          616000/f 1.2
150000-300000       0.158 f 0.5     4.21 × 10-4 f 0.5    6.67 × 10-5 f    616000/f 1.2

* Power density limit is applicable at frequencies greater than 100 MHz.
Notes: 1. Frequency, f, is in MHz.
       2. A power density of 10W/m2 is equivalent to 1 mW/cm2.
       3. A magnetic field strength of 1 A/m corresponds to 1.257 microtesla (µT) or
          12.57 milligauss (mG).


3. RF Exposure calculations

From §FCC 1.1310 table 1 and §Safety Code 6 table 5, the maximum permissible RF
exposure for an uncontrolled environment is 1mW/(cm2) (or 10 W/m2)*
      * 10 W/m2 = 1mW/ (cm2)
Power density (S) is calculated by the following formula:

S = (P * G)/4πR2

where, S = Power density (mW/cm2)
       P = Output power to antenna (mW)
       R = Distance between radiating structure and observation point (cm)
       G = Gain of antenna in numeric
       π = 3.1416

Example:
         Assume a mobile device operates at 2412MHz and its maximum output power
is 50mW, and the maximum gain of antenna is 1 (numeric) /0dBi.

then the power density (S) = (50 * 1)/4*π*202 = 0.00995 (mW/cm2) (or = 0.0995 W/m2)


                                                                   FCC ID. : I88X550NHV2
                                                               Report No.: TS08090052-EME
                                                                            Page 6 of 6

4. Test results

     Test Mode: 802.11b mode
                 Channel     Maximum Output power           Power density Limit of
   Channel      Frequency antenna gain to antenna                       power density
                  (MHz)      (numeric)   (mW)                (mW/cm2)    (mW/cm2)
  1 (lowest)       2412         3.98     298.90             0.236990067     1.0
  6 (middle)       2437         3.98     287.00             0.227368420     1.0
 11 (highest)      2462         3.98     289.12             0.228944463     1.0

     Test Mode: 802.11g mode
                 Channel     Maximum Output power           Power density Limit of
   Channel      Frequency antenna gain to antenna                       power density
                  (MHz)      (numeric)   (mW)                (mW/cm2)    (mW/cm2)
  1 (lowest)       2412         3.98     851.67             0.674109030     1.0
  6 (middle)       2437         3.98     963.42             0.763361310     1.0
 11 (highest)      2462         3.98     959.21             0.759853984     1.0

     Test Mode: 802.11n HT20 mode
                 Channel    Maximum Output power            Power density Limit of
   Channel      Frequency antenna gain to antenna                       power density
                  (MHz)      (numeric)   (mW)                (mW/cm2)    (mW/cm2)
  1 (lowest)       2412         3.98     685.43             0.542912880     1.0
  6 (middle)       2437         3.98     968.46             0.766884826     1.0
 11 (highest)      2462         3.98     804.49             0.637867015     1.0



    Test Mode: 802.11n HT40 mode
                Channel    Maximum Output power             Power density Limit of
  Channel      Frequency antenna gain to antenna                        power density
                 (MHz)      (numeric)   (mW)                 (mW/cm2)    (mW/cm2)
 3 (lowest)       2422         3.98     180.02              0.142472205     1.0
 6 (middle)       2437         3.98     384.50              0.304600172     1.0
 9 (highest)      2452         3.98     174.94              0.138589442     1.0

The Notice in Installation Manual has been stated as below:
While installing and operating this transmitter, the radio frequency exposure limit of
1mW/ (cm2) may be exceeded at distances close to the transmitter. therefore, the user
must maintain a minimum distance of 20 cm from the device at all time.



Document Created: 2008-10-02 15:27:37