MPE

FCC ID: I88WSR30

RF Exposure Info

Download: PDF
FCCID_4055900

                   FCC RF Exposure Report
            FCC ID                 : I88WSR30
            Equipment              : Multy U AC2100 Tri-Band WiFi System
            Model No.              : WSR30
            Brand Name             : ZYXEL
            Applicant              : Zyxel Communications Corporation
            Address                : No.2 Industry East RD. IX, Hsinchu Science
                                     Park, Hsinchu 30075, Taiwan, R.O.C
            Standard               : 47 CFR FCC Part 2.1091
            Received Date          : Aug. 01, 2018
            Tested Date            : Aug, 17 ~ Aug. 23, 2018


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Reviewed by:                        Approved by:




      Along Chen / Assistant Manager      Gary Chang / Manager




Report No.: FA880101                                                                  Page : 1 of 6
Report Version: Rev. 01


                                                   Table of Contents
1        MPE EVALUATION OF MOBILE DEVICES ......................................................................................... 4

1.1      LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE............................................. 4
1.2      MPE EVALUATION FORMULA ............................................................................................................. 4
1.3      MPE EVALUATION RESULTS .............................................................................................................. 5

2        TEST LABORATORY INFORMATION ................................................................................................. 6




Report No.: FA880101                                                                                                Page : 2 of 6
Report Version: Rev. 01


                                    Release Record
     Report No.           Version                   Description      Issued Date
      FA880101            Rev. 01   Initial issue                    Oct. 24, 2018




Report No.: FA880101                                              Page : 3 of 6
Report Version: Rev. 01


1         MPE EVALUATION OF MOBILE DEVICES
Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the
MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate,
since exposures are assumed to occur at distances of 20 cm or more from persons.



1.1       LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE
                                                                  2
      Frequency Range (MHz)              Power Density (mW /cm )            Averaging Time (minutes)
               300~1500                           F/1500                                 30
             1500~100000                            1.0                                  30


1.2       MPE EVALUATION FORMULA
                               Pt
                 Pd =
                          4 * Pi * R 2

Where
                                  2
Pd=   Power density in mW/cm
Pt=   EIRP in mW
Pi=   3.1416
R=    Measurement distance




Report No.: FA880101                                                                    Page : 4 of 6
Report Version: Rev. 01


1.3       MPE EVALUATION RESULTS

                          Maximum
                                                                                Power
   Frequency              Conducted   Rated Power   Antenna      Distance                       Limit
                                                                               Density                2
  Range (MHz)               Power        (dBm)      Gain (dBi)     (cm)               2       (mW/cm )
                                                                              (mW/cm )
                            (dBm)
For WLAN
    2412~2462               24.81        25.0           0          20           0.063                1
    5180~5240               26.27        26.5           0          20           0.089                1
    5745~5825               26.38        26.5           0          20           0.089                1
For BT
2402~2480 EDR               3.97           4            3          20           0.001                1
  2402~2480 LE              3.97           4            3          20           0.001                1

CONCULSION:
The device supports simultaneous transmission as below configurations


Wi-Fi 2.4GHz , Wi-Fi 5.18 ~ 5.24 GHz and Wi-Fi 5.745 ~ 5.825 GHz


The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density


WLAN 2.4G + WLAN 5G = 0.063 / 1 + 0.089 / 1+ 0.089 / 1 = 0.241


Therefore, the maximum calculation of this situation is 0.241, which is less than the “1” limit.




Report No.: FA880101                                                                 Page : 5 of 6
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




2          Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp (EMC and Wireless Communication Laboratory), it is our definitive objective is
to institute long term, trust—based associations with our clients. The expectation we set up with our clients is
based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to
grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our
website http://www.icertifi.com.tw.


Linkou                                 Kwei Shan                            Kwei Shan Site II
Tel: 886—2—2601—1640                   Tel: 886—3—271—8666                  Tel: 886—3—271—8640
No. 30—2, Ding Fwu Tsuen, Lin          No. 3—1, Lane 6, Wen San 3rd St.,    No. 14—1, Lane 19, Wen San 3rd
Kou District, New Taipei City,         Kwei Shan District, Tao Yuan City    St., Kwei Shan District, Tao Yuan
Taiwan, R.0.C.                         333, Taiwan, R.O.C.                  City 333, Taiwan, R.O.C.

If you have any suggestion, please feel free to contact us as below information.

Tel: 886—3—271—8666
Fax: 886—3—318—0155
Email: ICC_Service@icertifi.com.tw




==END=




Report No.: FAB80101                                                                       Page : 6 of 6
Report Version: Rev. 01



Document Created: 2018-10-24 13:31:27
Document Modified: 2018-10-24 13:31:27

© 2024 FCC.report