6

FCC ID: I88NETGEARRH348

Test Report

Download: PDF
FCCID_73105

            Industrial Technology Research Institute
            Electronics Research & Service Organization                                FCC ID : I88NETGE                348
            Bidg. 17, 195—4 Sec. 4, Chung Hsing Rd., Chutung,Hsinchu, 310                   Report No. : CEW—8703—008
            Taiwan,Republic Of China
            TEL : 886—3—5917069    FAX : 886—3—5825720                                      Page   1        of   17




             ELECTROMAGNETIC INTERFERENCE
                                               TEST REPORT

      Company                : ZyXEL COMMUNICATIONS CORPORATION.
      Address                : NO.6,InnovationRd. II,Science—Based Industrial Park,
                                HSin_C,hJ:lL Taiwan,L,&Q:C-

      Sample Name            _‘ ISDN RouterHub
      Model                  : RH348 (for NETGEAR INC.)
      Date Received : MAR. 18, 1998

      Date Tested            _ MAR. 25, 1998

      MEASUREMENT PORCEDURE USED :
            FCC RULES AND REGULATION PART 15 SUBPART B
            CLASS B OCTOBER 1996 AND ANSI C63.4 MAY 1992

WE HEREBY CERTIFY THAT: The measurements shown in the attachment were made in accordance
with the procedures indicated, and the energy emitted by the equipment was found to be within the
limits applicable. We assume full responsibility for the accuracy and completeness of these
measurements and vouch for the qualifications of all persons taking them.


                                             Name                               Signature                        Date
                                                                            e   y                  MA       p    y      9 P1
   Testing Engineer                 C.F.WuwNVLAP                            Caugei/ za             A"R 13) #"7
 Approving Manager |Paul Y. Liau/NVLAP                                      {Faus L T’ P           2 pr. /% radri
                                                                                                        ]

Notes :‘
1. This report will be invalid if duplicated or photocopied in part.
2. This report refers only to the specimen(s) submitted to testing, and be invalid as seperately used.
3. This report is invalid with out examination stamp and signature ofthis institute.
4. The tested specimen(s) will be preserved for thirty days from the date issued.
5. This is a NIST/NVLAP accrediated report but not constituted and eudorsed by U.S government.


                  Industrial Technology Research Institute
                  Electronics Research & Service Organization                                                                               FCC ID : I88NETGEARRH348
                  Bldg. 17, 195—4 Sec. 4, Chung Hsing Rd., Chutung,Hsinchu, 310                                                                      Repon No. : CEW—8§703—008
                  Taiwan,Republic Of China
                  TEL : 886—3—5917069 FAX : 886—3—5825720                                                                                            Page          2        of       17




                TABLE OF CONTENTS
TITLE ___ _             _         .                                                                                                                                    PAGENO.
TEST REPORT CERTIFICATION
1. GENERAL INFORMATION . 2 0 . 0 0 e0 0 9                          00e¥ verveeeerevenneeenevnnnenrennasenernernevereneneeneeneraee es ververeanneseversereeonecessseveeneneennenee 3

   1.1 DESCRIPTION OF EUT....2..2..0000 000 oeeererrerreerennenenerenrvnnmenmenmenmemenmcne

   1.2 DESCRIPTION OF PERIPHERALS . . .0 0 0 0 0                                                                                                                            eevververerennsennennennennencen 4

   1.3 EUT & PERIPHERALS SETUP DIAGRAM 1..22020000000e00e00er0 0n rmerververerevrnnrene en en en en en en en en revververseveereerennrenennennens 7
   1.4 EUT OPERATING CONDITION .sn 00000 en n meververene en vreerervernerenernernernernernrne enc rncrncon en mm cenvevvanneneeverereneeenee en en 8

   1.5 DESCRIPTION OF TEST SITE a.20000000000000enenereemnrerereeereeveneernennenneneereereeereenrennennennennceeeveeeeeeee en rneenernsensinsenvennensencens 8

2. CONDUCTED POWERLINE TEST.................c.cacucl..                                                                                                                                                                                                  9

  2.1 TEST EQUIPMENTS:. 22000000 00e en en en rveereervernernennennerverrernnennennennennennenne nc enc en en ere en ceveeveererncenenernvensensevensennsenceneencenen 9
  2.2 TEST SETUP .c ecencen ce en en reve en rraneaneanennennrencenveverververerenneneneen enc reeeeenrennenrennerneenecne                                                                                                             ...9

  2.3 CONDUCTED POWER LINE EMISSION LIMIT                                                                                                                                                                          ner nearvn e netvrne nern v nre ne r env e 10
  2.4 TEST PROCEDURE ..                                                                                                                                                                                                                        10

  2.5 UNCERTAINTY OF CONDUCTED EMISSION :2020 000000 e0 en en mm nnvnerverververververververeerneenereevenennrevenneensensensenmens 10

  2.6 LINE CONDUCTED RF VOLTAGE MEASUREMENT 12.2..2..00000000000000en en en en en reeverververververneenereenrenerncenrennennennecnes 11

  2.7 PHOTOS OF CONDUCTION TBEST cce n ceee enc en n enenenerrvenrnnenvarneneeneener en en en en nnennrnne nennennennennenererenveneencenee 12

3. RADIATED EMISSION TEST                                                                     es es esi re ae rven varn vanera                                                            aeseeseevernevnenneneeneeinesvaneereancen 13

  3.1 TEST EQUIPMENTS....2..0.000000en en en en ernereerererrennennennenne nc en envennerneveeverve en en cenvereerereeeeeeeeeeeeeeeeeenceereennenvenseneensenrrerenren 13
  3.2 TEST SETUP .n en enenememmenmenmennenmeneeneeneeneecnmencenees                                                                                                                                                            13
  3.3 RADIATION LIMIT a2 0 0 0                                                                                                                                                                                    re aner n cerane ne nev ne rcenv env en en 14
  3.4 TEST PROCEDURE 2.                                                                                                          nvennennennennevneveeverve en en en en en enennenrennenncecennennvncencens 14
  3.5 UNCERTAINTY OF RADIATED EMISSION ..0.,.2.00000 0000000000 ereereererrreerrnnranrnnraneanennenerverevereenennerereereneneeecernenencens 14

  3.6 RADIATED RF NOISE MEASUREMENT ......0020000000000000000000 0 errvvrevervrerrenrere n en en en en en en en evaveereereveevereeennennennenne 15

  3.7 PHOTOS OF OPEN STTE .. ....0.00 00000000 en en en nneneennennennrveneneveeveeneennennennenne n nnennennennennenne n ennenncveeveeververerernerncen 16

  3.7 PHOTOS OF OPEN SITE ... 002. e0 en en enememmmernvrververveennene n reeeeerervernernnennennennennennennennerneenveveneenneeneennennennenen en enc en 17


     Industrial Technology Research Institute
     Electronics Research & Service Organization                     FCC ID : I88NETGEARRH348
     Bldg. 17, 195—4 Sec. 4, Chung Hsing Rd., Chutung,Hsinchu, 310      Report No. : CEW—8703—008
     Taiwan,Republic Of China
     TEL : 886—3—5917069    FAX : 886—3—5825720                         Page   3   of   17




1. GENERAL INFORMATION


   1.1 DESCRIPTION OF EUT

     MANUFACTURER : ZyXEL COMMUNICATIONS CORPORATION.


     SAMPLE NAME                  _‘ ISDN Router Hub


     MODEL NUMBER : RH348


     SERIAL NO.                   1 enconoccccccclee


     POWER SUPPLY                 : 120VAC/60Hz


  Industrial Technology Research Institute
  Electronics Research & Service Organization
                                                                     FCC ID : I88NETGEARRH348
  Bldg. 17, 195—4 Sec. 4, Chung Hsing Rd., Chutung,Hsinchu, 310             Report No. : CEW—8703—008
  Taiwan,Republic Of China
  TEL : 886—3—5917069 FAX : 886—3—5825720                                   Page   4   of   1 7




1.2 DESCRIPTION OF PERIPHERALS

   (1) PC
         MODEL NUMBER                    _‘ NetServer LD Pro 6/180
         SERIAL NUMBER                   : $G70100107
         MANUFACTURER                    : HP CORP.
         F.CC ID                         kozcecee—.—
         POWER CORD                      : Unshielded , Detachable , 1.8m


   (2) MONITOR
         MODEL NUMBER                    _‘ JC—1404HMA
         SERIAL NUMBER                   _‘ 08D00346
         MANUFACTURER                    © NEC CORP.
         F.C.C. ID                       : A3D5YRIC—1404HMA
         POWER CORD                      : Unshielded , Detachable , 1.8m


   (3) KEYBOARD
         PRODUCT NUMBER : C1405C#ABO
         SERIAL NUMBER                   :‘ 3625M60145
         MANUFACTURER                    : HP CORP.
         F.C.C. ID                       : B94C1405X


   (4) PRINTER
         MODEL NUMBER                    : 5152—002
         SERIAL NUMBER                   : 0754365
         MANUFACTURER                    |IBM CORP.
         F.C.C. ID                       : BKM9A85152002


   (5) TELEPHONE(Z sets)
         MODEL NUMBER _‘ RS—802F
         SERIAL NUMBER : ————————
         MANUFACTURER | SWEETONE CORP.
         FCC ID                          pasaases>


Industrial Technology Research Institute
Electronics Research & Service Organization
                                                                     FCC ID : I88NETGEARRH348
Bldg. 17, 195—4 See. 4, Chung Hsing Rd., Chutung,Hsinchu, 310           Report No. : CEW—8703—008
Taiwan,Republic Of China
TEL : 886—3—5917069      FAX : 886—3—5825720
                                                                        Page   5_ of   17




 (6) PC
       MODEL NUMBER                    _‘ Vectra VE 5/133 series 3
       SERIAL NUMBER                   _‘ $G72200521
       MANUFACTURER                    :‘ HP CORP.
       FCC ID                          : BAVECTRAVE53


 (7) MONITOR
       MODEL NUMBER                    _‘ 8515A01
       SERIAL NUMBER                     —————————
       MANUFACTURER                    :‘ IBM CORP.
       FCC ID                         : ANO8515—A01


 (8) KEYBOARD
       MODEL NUMBER                    _‘ EO3633WLTW—C
       SERIAL NUMBER                     ———————
       MANUFACTURER                    /‘ HP CORP.
       FCC ID                         : CIGEO3633


 (9) PC
       MODEL NUMBER                    _‘ Vectra VE 5/133 series 3
       SERIAL NUMBER                   : $G72200556
       MANUFACTURER                    : HP CORP.
       FCC ID                         : BAVECTRAVE53


(10) MONITOR
       MODEL NUMBER                    _‘ JC—1571VMA—2
       SERIAL NUMBER                   _‘ 6201162EA
       MANUFACTURER                    © NEC CORP.
       FCC ID                         : A3DJC—1571VMA—2


 (11) KEYBOARD
       MODEL NUMBER                    _‘ EO3633WLTW—C
       SERIAL NUMBER                      ——————————
       MANUFACTURER                    :‘ HP CORP.
       FCC ID                         : CIGEO3633


Industrial Technology Research Institute
Electronics Research & Service Organization                     FCC ID : I88NETGEARRH348
Bldg. 17, 195—4 See. 4, Chung Hsing Rd., Chutung,Hsinchu, 310         Repor[ No.: CEW—8703—008
Taiwan,Republic Of China
TEL : 886—3—5917069 FAX : 886—3—5825720                               Page   6_   of    17




 (12) Fast Ether Pair
       MODEL NUMBER                     | EN1207—TX
       SERIAL NUMBER(1) : 633014578
       SERIAL NUMBER(2) : 645017820
       MANUFACTURER                    ‘ ACCTON CORP.
       FCC ID                         : HEDEN1207—TX

(13) Cable
NO.                  TYPE                      Connector        Shielded               Length
 A                 D Type                   RS232, metal        Yes                    1.8m
 B             Uncrossiover                 RJ—11, plastic      No                     2m
                twisted—pair
 C               Cross—over                 RJ—45, plastic      No                     2m
                 twisted—pair
 D             Uncross—over                 RJ—45, plastic      No                     SOft
                twisted—pair


          Industrial Technology Research Institute
          Electronics Research & Service Organization
                                                                                   FCC ID : I88NETGEARRH348
          Bldg. 17, 195—4 Sec. 4, Chung Hsing Rd., Chutung,Hsinchu, 310                   Report No.: CEW—8703—008
          Taiwan,Republic Of China
          TEL : 886—3—5917069 FAX : 886—3—5825720                                         Page   7       of   17




        1.3 EUT & PERIPHERALS SETUP DIAGRAM


                          NEC

                     L@E                                                   | TELEPHONE               |TELEPHON
                                |                                          |       (5)               '             (5)

  Tem                   mpreoyp |_®._| eur
 PRINTER
1@____|
! (4)
                                                          \]         I
                                                                               B          (B)
                          HPK/B(3)                         L
                       l                                       (C)
                     [—Ttem                                                        wEe
                          MONITOR                    (D              (D)           ’     MONITOR



                                                                           HP
                                         4                           —](2] PC(Q)


                          HPK/B(8)                                                       HPK/B(11
                    The indicated numbers (1)(2)(A)(B)—————please refer to item 1.2.


  Industrial Technology Research Institute
  Electronics Research & Service Organization
                                                                    FCC ID : I88NETGEARRH348
  Bldg. 17, 195—4 Sec. 4, Chung Hsing Rd., Chutung,Hsinchu, 310          Report No. : CEW—8703—008
  Taiwan,Republic Of China
  TEL : 886—3—5917069 FAX : 886—3—5825720                                Page      8   __of   17




1.4 EUT OPERATING CONDITION

  1. Powered on all equipments.

  2. Run software "ACCTEST.EXE"to transmit data packets for two PC‘s back and forth.

    The rest of ports connected to corss—over wire each other to simulate real condition.

  3. A D—type connector of EUT connected to HP PC(1), they would transmit data packets

    each other.

  4. Repeated these procedure untill test OK.

1.5 DESCRIPTION OF TEST SITE

  SITE DESCRIPTION                    : FCC certificate NO. :31040/8IT
                                        DNV certificate NO. :510—96—1016
                                        TUV certificate NO. : 19664582—9610
                                        Lloyd‘s certificate NO. :LA003
                                        BCIQ certificate NO. :SL2—IN—E—02
                                        NVLAP Lab code : 200118—0
                                        CNLA certificate NO. : CNLA—ZL97018
                                        VCCI certificate NO. : R—629, C—650


  NAME OF SITE                        : Electronics Research & Service Organization
                                        Industrial Technology Research Institute


  SITE LOCATION                       * K500, 195—4 , sec. 4, Chung Hsing Rd.,
                                        Chu—Tung Chen. Hsin—Chu, Taiwan 31015 R.O.C.


        Industrial Technology Research Institute
       Electronics Research & Service Organization                                FCC ID : I88NETGEARRH348
        Bldg. 17, 195—4 See. 4, Chung Hsing Rd., Chutung,Hsinchu, 310
        Taiwan,Republic Of China
                                                                                     Report No. : CEW—8703—008
        TEL : 886—3—5917069    FAX : 886—3—5825720
                                                                                     Page    9   of    17




2. CONDUCTED POWERLINE TEST


2.1 TEST EQUIPMENTS

      The following test equipments are used during the conducted powerline tests :


   MANUFACTURER OR TYPE                                       MODEL No               DATE OF CALIBRATION
SPECTRUM ANALYZER & DISPLAY                                    HP 8568 A                    MAR. 05, 1998
     QUASI—PEAK ADAPTER                                       HP 85650 A                    MAR. 05, 1998
   ISOLATION TRANSFORMER                                    SOLAR 7032—1                         N/A
               LLS.N.                                       EMCO 3850/2                     MAR. 25, 1997
               L.LS.N.                                      EMCO 3850/2                     MAR. 25, 1997
        TEST RECEIVER                                          R/S ESH3                     MAR. 13, 1998
       SHIELDED ROOM                                         KEENE 5983                          N/A




2.2 TEST SETUP



                                             POWERLINE of                 POWERLINE
                                             PERIPHERALS                    of EUT
          120vAC                                     i/                      J/
          60Hz «<———| LLSN.                                                          LLS.N. ———>
                                                                                            120VAC
                                                                                            60Hz

                                                            EUT &
                                                          PERIPHERALS



                                  120vAC
                                  5z          [isolate        SPECTRUM ANALYZER
                                  <           TRANSFORMER| _|/TEST RECEIVER


            Industrial Technology Research Institute
           Electronics Research & Service Organization                      FCC ID : I88NETGEARRH348
            Bldg. 17, 195—4 See. 4, Chung Hsing Rd., Chutung,Hsinchu, 310      Report No. : CEW—8703—008
            Taiwan,Republic Of China
            TEL : 886—3—5917069   FAX : 886—3—5825720                          Page    10   of   17




2.3 CONDUCTED POWER LINE EMISSION LIMIT

                     FREQUENCY                        MAXIMUM RF LINE VOLTAGE (dB L V)
                           (MHz)                           CLASS A             CLASS B
                       0.45 — 1.705                              60               48
                       1.705 — 30.0                            69.5               48

2.4 TEST PROCEDURE

The test procedure is performed in a 12ft X 12ft X 8ft(L x W X H) shielded room.
the EUT along with its peripherals were placed on a 1.0m(W)X 1.5m(L) and 0.8m in height wooden
table and the EUT was adjusted to maintain a 0.4 meter space from a vertical reference plane.         The
EUT was connected to power mains through a line impedance stabilization network (LISN) which
provides 50 ohm coupling impedance for measuring instrument and the chasis ground was bounded to
the horizontal ground plane of shielded room. All peripherals were connected to the second LISN and
the chasis ground also bounded to the horizontal ground plane of shielded room. The excess power
cable between the EUT and the LISN was bundled. The power cables of peripherals were unbundled.
All connecting cables of EUT and peripherals were moved to find the maximum emission.



2.5 UNCERTAINTY OF CONDUCTED EMISSION

           The uncertainty of conducted emission is +1.36dB.


       Industrial Technology Research Institute
       Electronics Research & Service Organization                                FCC ID : I88NETGEARRH348
       Bldg. 17, 195—4 Sec. 4, Chung Hsing Rd., Chutung,Hsinchu, 310                  Report No. : CEW—8703—008
       Taiwan,Republic Of China
       TEL : 886—3—5917069 FAX : 886—3—5825720                                        Page   11   of    17




2.6 LINE CONDUCTED RF VOLTAGE MEASUREMENT

       The frequency spectrum from 0.45 MHz to 30 MHz was investigated. All emissions not
       reported below are more than 20 dB below the prescribed limits.
       All readings are Quasi—peak values.
              Temperature : °C                                         Humidity        : 56 %RH.
  FREQUENCY                                      READING(dB L V)                                       LIMITS
    (MHz)                ONE END & GRD‘D                  THE OTHER END & GRD‘D                        (dB 4 V)
     0.450                             *                                   *                             48.0
     0.604                          32.91                                33.41                           48.0
     0.686                          33.12                                  *                            48.0
     5.005                          32.21                                33.31                          48.0
     6.557                          41.03                                  *                            48.0
     6.627                             *                                 39.43                          48.0
    11.317                          37.95                                  *                            48.0
    13.267                          40.06                                 *                             48.0
    13.337                             *                                 38.46                          48.0
    20.056                             *                                 48.98                          48.0
    20.162                          45.98                                 *                             48.0
     30.00                             *                                  *                             48.0
                     REMARKS : * Undetectable


          Industrial Technology Research Institute
         Electronics Research & Service Organization                              FCC ID : I88NETGEARRH348
          Bldg. 17, 195—4 See. 4, Chung Hsing Rd., Chutung,Hsinchu, 310              Repor[ No.: CEW—8703—008
          Taiwan,Republic Of China
          TEL : 886—3—5917069 FAX : 886—3—5825720                                    Page   13   of    17




3. RADIATED EMISSION TEST


3.1 TEST EQUIPMENTS

  The following test equipments are utilized in making the measurements contained in this report.


        MANUFACTURER OR TYPE                                         MODEL NO         DATE OF CALIBRATION
               CHASE ANTENNA                                          CBL6I11A              MAY. 26, 1997
             R/S TEST RECEIVER                                            ESMI              MAY. 22, 1997
       ANECHOIC/SHIELDED ROOM                                        KEENE 5981                  N/A



3.2 TEST SETUP

      The diagram below shows the test setup which is utilized to make these measurements.




                                             10m                             EUT &
                                                                          PERIPHERALS




                                                                                    PERIPHERAL


             Antenna Elevation Variable


                Industrial Technology Research Institute
            Electronics Research & Service Organization                         FCC ID : I88NETGEARRH348
                Bldg. 17, 195—4 See. 4, Chung Hsing Rd., Chutung.Hsinchu, 310       Report No.: CEW—8703—008
                Taiwan,Republic Of China
                TEL : 886—3—5917069 FAX : 886—3—5825720                             Page   7147 _   of   17




3.3 RADIATION LIMIT

All emanation from a class                B_      computing device or system, including any network of conductors
and apparatus connected thereto, shall not exceed the level of field strengths specified below :


                      FREQUENCY                  FIELD STRENGTHS(dB 4 V/M)
                          (MHz)                 CLASS A(10m) CLASS B(3m)
                         30—88                       39.0         40.0
                        88—216                       43.5         43.5
                         216—960                     46.4         46.0
                        960—1000                     49.5         54.0



           Note : (1)The tighter limit shall apply at the edge between two frequency bands.
                         (2)Distance refers to the distance in meters between the measuring instrument
                             antenna and the closest point of any part of the device or system.

3.4 TEST PROCEDURE

The devices under test were placed on a rotatable table top 0.8 meter above ground. The table was
rotated 360 degrees to determine the position of the highest radiation. EUT is set 10 meters from the
interference receiving antenna which is mounted on the top of a variable height mast. The antenna
height is varied between one meter and four meters above ground to find the maximum value of the
field strength Both horizontal polarization and vertical polarization of the antenna are set to make the
measurement.

The bandwidth setting on the E.M.I. meter (R/S TEST RECEIVER ESMI) is 120 KHz.
The levels are quasi peak value readings. The frequency spectrum from 30MHz to 1000MHz was
investigated.

3.5 UNCERTAINTY OF RADIATED EMISSION

                The uncertainty of radiated emission is +2.724B.


          Industrial Technology Research Institute
          Electronics Research & Service Organization                               FCC ID : I88NETGEARRH348
          Bldg. 17, 195—4 Sec. 4, Chung Hsing Rd., Chutung,Hsinchu, 310                    Repor{ No. : CEW—8703—008
          Taiwan,Republic Of China
          TEL : $86—3—5917069 FAX : 886—3—5825720                                          Page   15      of   17




   3.6 RADIATED RF NOISE MEASUREMENT

          The frequency spectrum from 30 MHz to 1000 MHz was investigated. All emissions not
          reported below are more than 20 dB below the prescribed limits.
          All readings are quasi—peak values.
                 Temperature : °C                                 Humidity : 75% RH

FREQ—       |ANTENNA|           CABLE             METER READING                   LIMITS          EMISSION LEVEL
UENCY        ractor              Loss             AT1Om (dB u V/M)                                AT3m (dB p V/M)
                                              HORIZON—| VERTICAL                              HORIZON—|        VERTICAL
(MHz)            (aB)             (aB)             TAL                           (dBa VM)|        __TAL
 30.00          19.71              1.20              *                    *        40.00           *                 *
110.00          11.17             2.10             2.24               8.68         43.50          25.50             31.94
120.00           9.13             2.20             5.32               9.80         43.50          29.35             33.83
122.88          11.92             2.26               *                5.60         43.50           *                29.78
180.00           5.72             2.70             3.92                   *        43.50          25.80              *
184.75           9.13             2.72               *                2.24         43.50           *                24.09
200.00           8.95             2.80               *                9.24         43.50           *                30.99
226.11          10.77             2.96               *                2.24         46.00           *                25.96
1000.00         24.69             5.70               *                    *        54.00           *                 *


          REMARKS : 1. * Undetectable
                              2. Emission level at 3m (dB { V/M) =Antenna Factor (dB) + Cable loss (dB)
                                                                          + Meter Reading at 10m (dB 4 V/M)+10(dB).
                             3. 10m measured data are transferred to 3m by the formula
                                 L2=L1(d1/d2) 4 V/M from CISPR 22
                                 20LogL2=20LogL1+20Log(d1/d2)dB L V/M


                         FCC ID:I 8 8 NETGEARRH348




Exhibit C__—   Measurement Report



Document Created: 2001-05-08 11:46:06
Document Modified: 2001-05-08 11:46:06

© 2024 FCC.report