MPE

FCC ID: I88MAX206M2

RF Exposure Info

Download: PDF
FCCID_925377

                                                             FCC ID. : I88MAX206M2
                                                          Report No.: TS08030041-EME
                                                                       Page 1 of 7




Maximum Permissible Exposure (MPE)
        Evaluation Report

                   Report No.      : TS08030041-EME
                   Model No.       : MAX-206M2
                   Issued Date     : Mar. 11, 2008




Applicant     : ZyXEL Communications Corporation
               6, Innovation Rd II, Science-Based Industrial Park,
               Hsin-Chu, Taiwan

Test By       : Intertek Testing Services Taiwan Ltd.
                No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li,
                Shiang-Shan District, Hsinchu City, Taiwan



This test report consists of 7 pages in total. It may be duplicated completely
for legal use with the allowance of the applicant. It shall not be reproduced
except in full, without the written approval of Intertek Laboratory. The test
result(s) in this report only applies to the tested sample(s).


Report Engineer




 Sunny Liu


Project Engineer                                          Reviewed By




 Jimmie Liu                                               Kevin Chen


                                                                                                 FCC ID. : I88MAX206M2
                                                                                              Report No.: TS08030041-EME
                                                                                                           Page 2 of 7




                                                  Table of Contents

Summary of Tests ............................................................................................................. 3

1. Introduction .................................................................................................................. 4

2. RF Exposure Limit ....................................................................................................... 4

3. RF Exposure calculations ............................................................................................. 5

4. Test results .................................................................................................................... 5


                                                         FCC ID. : I88MAX206M2
                                                      Report No.: TS08030041-EME
                                                                   Page 3 of 7



Summary of Tests

MPE Evaluation meet FCC OET No. 65: 1997/ IEEE C95.1-1999

    WiMAX IEEE802.16e Indoor Simple CPE-2.5GHz -Model: MAX-206M2
                       FCC ID: I88MAX206M2


      Test                          Reference                       Results
 MPE Evaluation    FCC Guidelines for Human Exposure IEEE C95.1      Pass


                                                                 FCC ID. : I88MAX206M2
                                                              Report No.: TS08030041-EME
                                                                           Page 4 of 7



1. Introduction

The EUT operates in the 2.5GHz band about WiMAX IEEE 802.16e. Due to the EUT
(include antenna) at its normal operation distance is at least 20 cm from the human body,
the EUT was defined as a Mobile Device.


The reason to do the MPE Evaluation is to avoid the RF hazard to human body. The
maximum output power and gain of the antenna were used to calculate the limited
Power density (S) at 20cm distance away from the product. The limit for Maximum
Permissible Exposure (MPE) specified in FCC 1.1310 is followed.


According to 1.1307 (b)(1), systems operating under the provisions of this section shall
be operated in a manner that ensure that the public is not exposed to radio frequency
energy level in excess of the Commission’s guideline.



2. RF Exposure Limit

According to FCC 1.1310: The criteria listed in the following table shall be used to
evaluate the environmental impact of human exposure to radio-frequency (RF) radiation
as specified in 1.1307(b).

                   Limits for Maximum Permissible Exposure (MPE)

   Frequency       Electric Field Magnetic Field
                                                     Power Density       Average Time
     Range           Strength         Strength
                                                       (mW/cm2)           (minutes)
     (MHz)            (V/m)            (A/m)
                   (A) Limits for Occupational / Control Exposures
     30-300             61.4             0.163               1.0               6
   300-1500               -                 -              F/300               6
 1500-100,000             -                 -                5                 6
               (B) Limits for General Population / Uncontrolled Exposure
     30-300             27.5             0.073               0.2               30
   300-1500               -                 -              F/1500              30
 1500-100,000             -                 -                1.0               30

F= Frequency in MHz


                                                               FCC ID. : I88MAX206M2
                                                            Report No.: TS08030041-EME
                                                                         Page 5 of 7


3. RF Exposure calculations

From §FCC 1.1310 table 1, the maximum permissible RF exposure for an
uncontrolled environment is 1mW/(cm2)
Power density (S) is calculated by the following formula:

S = (P * G)/4πR2

where, S = Power density (mW/cm2)
       P = Output power to antenna (mW)
       R = Distance between radiating structure and observation point (cm)
       G = Gain of antenna in numeric
       π = 3.1416

Example:
         Assume a mobile device operates at 2412MHz and its maximum output power
is 50mW, and the maximum gain of antenna is 1 (numeric) /0dBi.

then the power density (S) = (50 * 1)/4*π*202 = 0.00995 (mW/cm2)

4. Test results

                    Environmental
  Input Power                       Antenna Type       Modulation      Coding Rate
                     Conditions
 120Vac, 60Hz        20℃, 65%       PCB antenna          QPSK                1/2


                  Maximum       Output       Power         Limit of
 Frequency         antenna      power        density        power       Band Width
   (MHz)            gain      to antenna                   density        (MHz)
                  (numeric      (mW)        (mW/cm2)      (mW/cm2)
    2500           3.98        496.5923 0.393305613               1.0             5
    2590           3.98        486.4072 0.385238909               1.0             5
    2685           3.98        393.5501 0.311695222               1.0             5
    2500           3.98        492.0395 0.389699766               1.0            10
    2590           3.98        432.5138 0.342554869               1.0            10
    2685           3.98        385.4784 0.305302348               1.0            10
The Notice in Installation Manual has been stated as below:
While installing and operating this transmitter, the radio frequency exposure limit of
1mW/(cm*cm) may be exceeded at distances close to the transmitter. therefore, the user
must maintain a minimum distance of 20 cm from the device at all time.


                                                               FCC ID. : I88MAX206M2
                                                            Report No.: TS08030041-EME
                                                                         Page 6 of 7




                  Environmental
  Input Power                       Antenna Type       Modulation      Coding Rate
                   Conditions
 120Vac, 60Hz      20℃, 65%         PCB antenna          QPSK               3/4


                Maximum        Output        Power         Limit of
 Frequency       antenna       power         density        power       Band Width
   (MHz)          gain       to antenna                    density        (MHz)
                (numeric       (mW)         (mW/cm2)      (mW/cm2)
    2500          3.98        490.9079     0.388803481        1.0             5
    2590          3.98        465.5861     0.36874840         1.0             5
    2685          3.98        387.2576     0.30671156         1.0             5
    2500          3.98        483.0588     0.382586943        1.0            10
    2590          3.98        425.5984     0.337077795        1.0            10
    2685          3.98        374.9730     0.296982012        1.0            10


                  Environmental
  Input Power                       Antenna Type       Modulation      Coding Rate
                   Conditions
 120Vac, 60Hz      20℃, 65%         PCB antenna          16QAM              1/2


                Maximum        Output        Power         Limit of
 Frequency       antenna       power         density        power       Band Width
   (MHz)          gain       to antenna                    density        (MHz)
                (numeric       (mW)         (mW/cm2)      (mW/cm2)
    2500           3.98        484.1724 0.383468897               1.0             5
    2590           3.98        448.7454 0.355410410               1.0             5
    2685           3.98        372.3917 0.294937602               1.0             5
    2500           3.98        449.7799 0.356229716               1.0            10
    2590           3.98        408.3194 0.323392650               1.0            10
    2685           3.98        361.4099 0.286239882               1.0            10
The Notice in Installation Manual has been stated as below:
While installing and operating this transmitter, the radio frequency exposure limit of
1mW/(cm*cm) may be exceeded at distances close to the transmitter. therefore, the user
must maintain a minimum distance of 20 cm from the device at all time.


                                                               FCC ID. : I88MAX206M2
                                                            Report No.: TS08030041-EME
                                                                         Page 7 of 7




                  Environmental
  Input Power                       Antenna Type       Modulation      Coding Rate
                   Conditions
 120Vac, 60Hz      20℃, 65%         PCB antenna          16QAM              3/4


                Maximum        Output        Power         Limit of
 Frequency       antenna       power         density        power       Band Width
   (MHz)          gain       to antenna                    density        (MHz)
                (numeric       (mW)         (mW/cm2)      (mW/cm2)
    2500          3.98        475.3352     0.376469801        1.0             5
    2590          3.98        444.6313     0.352151988        1.0             5
    2685          3.98        367.2823     0.290890906        1.0             5
    2500          3.98        437.5221     0.346521467        1.0            10
    2590          3.98        405.5085     0.321166430        1.0            10
    2685          3.98        344.3499     0.272728262        1.0            10


The Notice in Installation Manual has been stated as below:
While installing and operating this transmitter, the radio frequency exposure limit of
1mW/(cm*cm) may be exceeded at distances close to the transmitter. therefore, the user
must maintain a minimum distance of 20 cm from the device at all time.



Document Created: 2008-03-12 15:55:40
Document Modified: 2008-03-12 15:55:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC