RF Exposure Info (MPE).pdf

FCC ID: I88EX5510-B0

RF Exposure Info

Download: PDF
FCCID_4486788

                                                           RF Exposure Report

                       Report No.: SA190806E11

                            FCC ID: I88EX5510-B0

                       Test Model: EX5510-B0, PX7511-B0, DX5510-B0

                 Received Date: Aug. 06, 2019

                         Test Date: Aug. 26, 2019

                     Issued Date: Oct. 04, 2019


                         Applicant: Zyxel Communications Corporation

                          Address: No.2 Industry East RD. IX, Hsinchu Science Park, Hsinchu 30075, Taiwan



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan.
            Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                           Taiwan.
       FCC Registration /
                           723255 / TW2022
      Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: SA190806E11                                              Page No. 1 / 7                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits For Maximum Permissible Exposure (MPE) ............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
    2.4      Antenna Gain ...................................................................................................................................... 6
    2.5      Calculation Result of Maximum Conducted Power ............................................................................. 7




Report No.: SA190806E11                                              Page No. 2 / 7                                              Report Format Version: 6.1.1


                                              Release Control Record


Issue No.                 Description                                         Date Issued
SA190806E11               Original release.                                   Oct. 04, 2019




Report No.: SA190806E11                          Page No. 3 / 7        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Dual-Band Wireless AX Gigabit Ethernet Gateway,
                          Wireless AX 10G PON Gateway with VoIP,
                          Wireless AX VDSL Bonding Gateway
              Brand: ZYXEL

        Test Model: EX5510-B0, PX7511-B0, DX5510-B0

    Sample Status: ENGINEERING SAMPLE

          Applicant: Zyxel Communications Corporation

          Test Date: Aug. 26, 2019

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:       Oct. 04, 2019
                                 Wendy Wu / Specialist




     Approved by :                                              ,   Date:       Oct. 04, 2019
                                  May Chen / Manager




Report No.: SA190806E11                        Page No. 4 / 7                        Report Format Version: 6.1.1


2      RF Exposure

2.1      Limits for Maximum Permissible Exposure (MPE)

    Frequency Range            Electric Field     Magnetic Field       Power Density      Average Time
                                                                                2
         (MHz)                Strength (V/m)      Strength (A/m)         (mW/cm )           (minutes)
                               Limits For General Population / Uncontrolled Exposure
        0.3-1.34                   614                  1.63               (100)*                30
                                                                                  2
         1.34-30                  824/f                2.19/f             (180/f )*              30
         30-300                    27.5                0.073                0.2                  30
        300-1500                    …                    …                 f/1500                30
      1500-100,000                  …                    …                  1.0                  30

f = Frequency in MHz ; *Plane-wave equivalent power density



2.2      MPE Calculation Formula

                          2
Pd = (Pout*G) / (4*pi*r )
where
                                   2
Pd = power density in mW/cm
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm



2.3      Classification

      The antenna of this product, under normal use condition, is at least 27cm away from the body of the user.
         So, this device is classified as Mobile Device.




Report No.: SA190806E11                            Page No. 5 / 7                       Report Format Version: 6.1.1


                                                                                                                       soocert
                                                                                                                        veniras




24          Antenna Gain

                                                        Antenna                                                        Cable
fi"::'       Chain No.        Brand         Model          Gain      Frequ(egfi)zl)range   Aljrtenna    Co_ln_nector    Length
        -                                                 (dBi)                             yP°              y°°       (mm)
  1_|       2G Chain 2                 65—034—000014B     0.12          2.4~2.4835        Dipole     i—pex (MHE)        150
                                                                      2.4~2.4835
 2          2G Chain 3       Airgain   65—034—000015B     0.12     5.15~5.85 (5G for      Dipole     i—pex (MHF)        100
                                                                   RX zero wait DFS)
 3          2G Chain 0                 65—034—0000168     0.12          2.4~2.4835        Dipole     i—pex (MHEF)        65
 4          2G Chain 1                 65—034—000017B     0.12          2.4~2.4835        Dipole     i—pex (MHE)        130
 5_         5G   Chain   2             65—034—000018B       0           5.15~5.85         Dipole     i—pex   (MHEF)     195
 6          5G   Chain   0   Airgain   65—034—0000198       0           5.15~5.85         Dipole     i—pex   (MHE)      150
 7_|        5G   Chain   3             65—034—000020B       0           5.15~5.85         Dipole     i—pex   (MHE)      250
 8          5G   Chain   1             65—034—000021B       0           5.15~5.85         Dipole     i—pex   (MHEF)     230




Report No.: $A190806E11                                 Page No. 6 /7                                Report Format Version: 6.1.1


2.5     Calculation Result of Maximum Conducted Power



                    Evaluation
      Operation                   Max Power    Antenna Gain    Distance     Power Density        Limit
                    Frequency                                                        2                 2
       Mode                         (mW)           (dBi)         (cm)         (mW/cm )         (mW/cm )
                      (MHz)
 WLAN 2.4GHz              2437     995.204           6.14         27           0.44666               1

 WLAN U-NII-1             5200     975.47            6.02         27           0.42587               1

 WLAN U-NII-3             5785     988.981           6.02         27           0.43177               1

NOTE:
1. Determining compliance based on the results of the compliance measurement, not taking into account
    measurement instrumentation uncertainty.
2. 2.4GHz: Directional gain = 0.12dBi + 10log(4) = 6.14dBi
    5GHz: Directional gain = 0dBi + 10log(4) = 6.02dBi



Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density


WLAN 2.4GHz + WLAN 5GHz = 0.44666 / 1 + 0.43177 / 1 = 0.87843
Therefore the maximum calculations of above situations are less than the “1” limit.



--- END ---




Report No.: SA190806E11                       Page No. 7 / 7                       Report Format Version: 6.1.1



Document Created: 2019-10-24 00:56:05
Document Modified: 2019-10-24 00:56:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC