Test Report (Co-located)

FCC ID: I88EMG3435Q20B

Test Report

Download: PDF
FCCID_4235993

                       Supplemental “Transmit Simultaneously” Test Report

                       Report No.: RF181219E02-2

                            FCC ID: I88EMG3435Q20B

                       Test Model: EMG3435-Q20A

                   Series Model: SoMA5200

                 Received Date: Dec. 19, 2018

                         Test Date: Jan. 23 to 29, 2019

                     Issued Date: Mar. 12, 2019


                         Applicant: Zyxel Communications Corporation

                          Address: No.2 Industry East RD. IX, Hsinchu Science Park, Hsinchu 30075, Taiwan


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.
            Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                           Taiwan R.O.C.
       FCC Registration /
                           723255 / TW2022
      Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. This report
should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: RF181219E02-2                                            Page No. 1 / 29                                            Report Format Version: 6.1.1
Reference No.: {ref-reports}


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.1.1    Test Mode Applicability and Tested Channel Detail ............................................................................. 8
    3.2      Description of Support Units ............................................................................................................. 10
    3.2.1    Configuration of System under Test ................................................................................................... 11
4         Test Types and Results ...................................................................................................................... 13
    4.1      Radiated Emission and Bandedge Measurement ............................................................................. 13
    4.1.1    Limits of Radiated Emission and Bandedge Measurement .............................................................. 13
    4.1.2    Test Instruments ................................................................................................................................ 14
    4.1.3    Test Procedures ................................................................................................................................. 16
    4.1.4    Deviation from Test Standard ............................................................................................................ 17
    4.1.5    Test Setup .......................................................................................................................................... 17
    4.1.6    EUT Operating Conditions................................................................................................................. 18
    4.1.7    Test Results ....................................................................................................................................... 19
    4.2      Conducted Emission Measurement .................................................................................................. 22
    4.2.1    Limits of Conducted Emission Measurement .................................................................................... 22
    4.2.2    Test Instruments ................................................................................................................................ 22
    4.2.3    Test Procedures ................................................................................................................................. 23
    4.2.4    Deviation from Test Standard ............................................................................................................ 23
    4.2.5    Test Setup .......................................................................................................................................... 23
    4.2.6    EUT Operating Conditions................................................................................................................. 23
    4.2.7    Test Results ....................................................................................................................................... 24
    4.3      Conducted Out of Band Emission Measurement .............................................................................. 26
    4.3.1    Limits of Conducted Out of Band Emission Measurement................................................................ 26
    4.3.2    Test Setup .......................................................................................................................................... 26
    4.3.3    Test Instruments ................................................................................................................................ 26
    4.3.4    Test Procedures ................................................................................................................................. 26
    4.3.5    Deviation from Test Standard ............................................................................................................ 26
    4.3.6    EUT Operating Conditions................................................................................................................. 26
    4.3.7    Test Results ....................................................................................................................................... 26
5         Pictures of Test Arrangements .......................................................................................................... 28
Appendix – Information of the Testing Laboratories ................................................................................. 29




Report No.: RF181219E02-2                                            Page No. 2 / 29                                             Report Format Version: 6.1.1
Reference No.: {ref-reports}


                                               Release Control Record


Issue No.                      Description                                     Date Issued
RF181219E02-2                  Original release.                               Mar. 12,2019




Report No.: RF181219E02-2                          Page No. 3 / 29      Report Format Version: 6.1.1
Reference No.: {ref-reports}


1    Certificate of Conformity


              Product: Dual-Band Wireless AC2600 Gigabit Ethernet Gateway

                Brand: ZYXEL

          Test Model: EMG3435-Q20A

       Series Model: SoMA5200

     Sample Status: ENGINEERING SAMPLE

           Applicant: Zyxel Communications Corporation

            Test Date: Jan. 23 to 29, 2019

          Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247)
                           47 CFR FCC Part 15, Subpart E (Section 15.407)
                           ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                                ,   Date:       Mar. 12, 2019
                                  Claire Kuan / Specialist




      Approved by :                                                ,   Date:       Mar. 12, 2019
                                   May Chen / Manager




Report No.: RF181219E02-2                        Page No. 4 / 29                     Report Format Version: 6.1.1
Reference No.: {ref-reports}


                                                                                                                       Eooert
                                                                                                                        venitas



2      Summary of Test Results


                             47 CFR FCC Part 15, Subpart C, E (SECTION 15.247, 15.407)

           FCC
                                              Test Item                   Result                   Remarks
         Clause
          15.207                                                                    Meet the requirement of limit.
          5.20                      AC Power Conducted                    PASS      Minimum passing margin is —10.14dB
      15.407(b)(6)                       Emission                                   at 0.43906MHz.
    15.205 / 15.209 /
                                    .              faai                             Meet the requirement of limit.
        15.247              at                E               Band
         5     (d)               ad|aév‘ajd       HSSIOHS andt an         PASS      Minimum passing margin is —1.30B at
        15.407(b)                        ge Measuremen                              4874.00MHz.
      (1/2/3/4(i/ii}6)
Note:
Determining compliance based on the results of the compliance measurement, not taking into account
measurement instrumentation uncertainty.

2.1      Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16—4—2:



                         Measurement                                          Frequency             ExpancéESQl)Jr(]f? rlainty

         Conducted Emissions at mains ports                              150kHz ~ 30MHz                      1.8 dB
            Radiated Emissions up to 1 GHz                                30MHz ~ 1GHz                       5.1 dB
                                                                           1GHz ~ 6GHz                       5.1 dB
           Radiated Emissions above 1 GHz                                 6GHz ~ 18GHz                       5.0 dB
                                                                          18GHz ~ 40GHz                      5.2 dB



2.2       Modification Record
There were no modifications required for compliance.




Report No.: RF181219E202—2                                  Page No. 5 / 29                          Report Format Version: 6.1.1


3     General Information
3.1     General Description of EUT
 Product                         Dual-Band Wireless AC2600 Gigabit Ethernet Gateway
 Brand                           ZYXEL
 Test Model                      EMG3435-Q20A
 Series Model                    SoMA5200
 Status of EUT                   ENGINEERING SAMPLE
 Power Supply Rating             DC 12V from adapter
                                 CCK, DQPSK, DBPSK for DSSS
 Modulation Type                 64QAM, 16QAM, QPSK, BPSK for OFDM
                                 256QAM for OFDM in 11ac mode
 Modulation Technology           DSSS,OFDM
                                 802.11b: up to 11Mbps
                                 802.11a/g: up to 54Mbps
 Transfer Rate                   802.11n: up to 600Mbps
                                 802.11ac: up to 1733.3Mbps
                                 2.4GHz: 2.412GHz ~ 2.462GHz
 Operating Frequency             5GHz: 5.18GHz ~ 5.24GHz, 5.745GHz ~ 5.825GHz
                                 2.4GHz:
                                 802.11b, 802.11g, 802.11n (HT20): 11
                                 802.11n (HT40): 7
 Number of Channel               5GHz:
                                 802.11a, 802.11n (HT20), 802.11ac (VHT20): 9
                                 802.11n (HT40), 802.11ac (VHT40): 4
                                 802.11ac (VHT80): 2
 Antenna Type                    Refer to Note
 Antenna Connector               Refer to Note
 Accessory Device                NA
 Data Cable Supplied             Ethernet Cable x 1 (Unshielded 1.8m)
Note:
1. The EUT has below model names, which are identical to each other in all aspects except for the following:
        Brand                    Model No.                                      Difference
                               EMG3435-Q20A                  The Variation of model number is for strategy of
        ZYXEL
                                SoMA5200                     marketing. The circuit of each model is identical.

From the above models, model: EMG3435-Q20A was selected as representative model for the test and its
data are recorded in this report.
2. Simultaneously transmission condition.
     Condition                                           Technology
          1                        WLAN 2.4GHz                               WLAN 5GHz
Note: The emission of the simultaneous operation has been evaluated and no non-compliance was found.
3. The EUT must be supplied with a power adapter (for test only, not for sale) as following table:
   Brand        Model No.                                           Spec.
                                AC Input: 100-240Vac, 0.9A, 50/60Hz
APD        WA-36A12R            DC Output: 12V, 3A
                                DC Output Cable: 1.5m unshielded with one core




Report No.: RF181219E02-2                        Page No. 6 / 29                           Report Format Version: 6.1.1
Reference No.: {ref-reports}


4. The antennas provided to the EUT, please refer to the following table:
                                                           Antenna Net   Frequency
Antenna                                                                                                Connector
             Chain No.         Brand       Model              Gain          range     Antenna type
  No.                                                                                                    Type
                                                              (dBi)         (GHz)
              Chain 0                                           3.5      2.4~2.4835
    1                          WHA YU   C107-511211-A           6.0      5.15~5.25
              Chain 3
                                                                5.3      5.725~5.85
              Chain 1                                           3.5      2.4~2.4835
    2                          WHA YU   C107-511211-A           6.0      5.15~5.25
              Chain 2
                                                                5.3      5.725~5.85
                                                                                         Dipole          N type
              Chain 2                                           3.5      2.4~2.4835
    3                          WHA YU   C107-511211-A           6.0      5.15~5.25
              Chain 1
                                                                5.3      5.725~5.85
              Chain 3                                           3.5      2.4~2.4835
    4                          WHA YU   C107-511211-A           6.0      5.15~5.25
              Chain 0
                                                                5.3      5.725~5.85
5. The EUT incorporates a MIMO function.
                                                    2.4GHz Band
     MODULATION MODE                                           TX & RX CONFIGURATION
              802.11b                                 4TX                                   4RX
              802.11g                                 4TX                                   4RX
         802.11n (HT20)                               4TX                                   4RX
         802.11n (HT40)                               4TX                                   4RX
                                                     5GHz Band
     MODULATION MODE                                           TX & RX CONFIGURATION
              802.11a                                 4TX                                   4RX
         802.11n (HT20)                               4TX                                   4RX
         802.11n (HT40)                               4TX                                   4RX
        802.11ac (VHT20)                              4TX                                   4RX
        802.11ac (VHT40)                              4TX                                   4RX
        802.11ac (VHT80)                       4TX                                   4RX
Note:
1. All of modulation mode support beamforming function except 802.11b/g/a modulation mode.
6. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF181219E02-2                          Page No. 7 / 29                        Report Format Version: 6.1.1
Reference No.: {ref-reports}


3.1.1       Test Mode Applicability and Tested Channel Detail

     EUT                                   APPLICABLE TO
  CONFIGURE                                                                                          DESCRIPTION
    MODE              RE1G            RE<1G              PLC                OB

        -                √                √                 √                 √                             -

             RE1G: Radiated Emission above 1GHz &
Where                                                      RE<1G: Radiated Emission below 1GHz
             Bandedge Measurement
             PLC: Power Line Conducted Emission            OB: Conducted Out-Band Emission Measurement

Note: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on Z-plane.


Radiated Emission Test (Above 1GHz):
    Following channel(s) was (were) selected for the final test as listed below.
                                   AVAILABLE                                         MODULATION
            MODE                                         TESTED CHANNEL                                     MODULATION TYPE
                                    CHANNEL                                          TECHNOLOGY

            802.11b                   1 to 11                     6                      DSSS                        1
              +
                                    5180-5240,
            802.11a                                              157                     OFDM                        6
                                    5745-5825


Radiated Emission Test (Below 1GHz):
    Following channel(s) was (were) selected for the final test as listed below.
                                   AVAILABLE                                         MODULATION
            MODE                                         TESTED CHANNEL                                     MODULATION TYPE
                                    CHANNEL                                          TECHNOLOGY

            802.11b                   1 to 11                     6                      DSSS                        1
              +
                                    5180-5240,
            802.11a                                              157                     OFDM                        6
                                    5745-5825


Power Line Conducted Emission Test:
    Following channel(s) was (were) selected for the final test as listed below.
                                   AVAILABLE                                         MODULATION
            MODE                                         TESTED CHANNEL                                     MODULATION TYPE
                                    CHANNEL                                          TECHNOLOGY

            802.11b                   1 to 11                     6                      DSSS                        1
              +
                                    5180-5240,
            802.11a                                              157                     OFDM                        6
                                    5745-5825


Conducted Out-Band Emission Measurement:
    Following channel(s) was (were) selected for the final test as listed below.
                                   AVAILABLE                                         MODULATION
            MODE                                         TESTED CHANNEL                                     MODULATION TYPE
                                    CHANNEL                                          TECHNOLOGY

            802.11b                   1 to 11                     6                      DSSS                        1
              +
                                    5180-5240,
            802.11a                                              157                     OFDM                        6
                                    5745-5825




Report No.: RF181219E02-2                             Page No. 8 / 29                                Report Format Version: 6.1.1
Reference No.: {ref-reports}


Test Condition:

   APPLICABLE TO               ENVIRONMENTAL CONDITIONS           INPUT POWER             TESTED BY

        RE1G                       23deg. C, 63%RH               120Vac, 60Hz           Frank CHuang

        RE<1G                       22deg. C, 70%RH               120Vac, 60Hz              Andy Ho

          PLC                       23deg. C, 74%RH               120Vac, 60Hz              Andy Ho

          OB                        25deg. C, 60%RH               120Vac, 60Hz          Anderson Chen




Report No.: RF181219E02-2                       Page No. 9 / 29                  Report Format Version: 6.1.1
Reference No.: {ref-reports}


3.2      Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.

 ID          Product                 Brand                Model No.            Serial No.        FCC ID              Remarks
 A.           Laptop                 DELL                   E6420              B92T3R1          FCC DoC          Provided by Lab
 B.          Adapter                  APD                WA-36A12R                NA               NA            Supplied by client
Note:
1. All power cords of the above support units are non-shielded (1.8m).


 ID        Descriptions               Qty.               Length (m)       Shielding (Yes/No)   Cores (Qty.)          Remarks
 1.        RJ-45 Cable                  1                        10               No                0            Provided by Lab
 2.         DC Cable                    1                    1.5                  No                1            Supplied by client
Note: The core(s) is(are) originally attached to the cable(s).




Report No.: RF181219E02-2                                   Page No. 10 / 29                            Report Format Version: 6.1.1
Reference No.: {ref-reports}


                                                                                             Eooert
                                                                                              venitas



3.2.1    Configuration of System under Test



For conducted emission test:




                                                             EUT




    (B) Adapter
                                       WAN                  LAN Port 1~4




                                                                               Remote Site




                                     (A)Laptop




Report No.: RF181219E202—2                       Page No. 11 / 29          Report Format Version: 6.1.1


                                                                                                   Eooert
                                                                                                    venitas



For other test items:




                                                    EUT




                              RJ45                  LAN Port 1~4     DC IN




                                                                         (2)


                                  (1)                                                 Under Table




                                                                   (B) Adapter




                             (A)Laptop




Report No.: RF181219E202—2               Page No. 12 /29                         Report Format Version: 6.1.1


                                                                                                                         C
                                                                                                                       Eooert
                                                                                                                        venitas



4          Test Types and Results
4.1        Radiated Emission and Bandedge Measurement

4.1.1        Limits of Radiated Emission and Bandedge Measurement

Radiated emissions which fall in the restricted bands must comply with the radiated emission limits
specified as below table.

                Frequencies                              Field Strength                       Measurement Distance
                     (MHz)                              (microvolts/meter)                            (meters)
               0.009 ~ 0.490                              2400/F(kHz)                                    300
               0.490 ~ 1.705                              24000/F (kHz)                                  30
                1.705 ~ 30.0                                    30                                       30
                     30 ~ 88                                   100                                        3
                  88 ~216                                      150                                        3
                 216 ~ 960                                     200                                        3
                 Above 960                                     500                                        3
Note:
1.    The lower limit shall apply at the transition frequencies.
2.         Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.         For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
           peak field strength of any emission shall not exceed the maximum permitted average limits, specified
           above by more than 20dB under any condition of modulation.
Limits of unwanted emission out of the restricted bands
                       Applicable To                                                      Limit

     789033 DO2 General UNIl Test Procedure                                       Field Strength at 3m
               New Rules v02r01                                  PK:74 (dBuV/m)                      AV:54 (dBuV/m)
                                                                                               Equivalent Field Strength at
      Frequency Band               Applicable To                     EIRP Limit                            3m

      5150~5250 MHz                15.407(b)(1)
      5250~5350 MHz                15.407(b)(2)                PK:—27 (dBm/MHz)                     PK:68.2(dBuV/im)
      5470~5725 MHz                15.407(b)(3)
                                                              PK=27 (dBm/MHz) 2‘                   PK: 68.2(dBuV/m) 12
                                                    .         PK:10 (dBm/MHz) *                   PK:105.2 (dBuV/m)
      5725~5850 MHz            B       15.407(b)(4)()        PK15.6 (dBm/MHz) *                   PK: 110.8(dBuVim)
                                                               PK:27 (dBm/MHz) *                  PK:122.2 (dBuV/im) *
                               C    15.407(b)(4)(ii)                       Emission limits in section 15.247(d)
                                                                     * below the band edge increasing linearly to 10
    "‘ beyond 75 MHz or more above of the band edge.       dBm/MHz at 25 MHz above.
    * below the band edge increasing linearly to a level * from 5 MHz above or below the band edge
         of 15.6 dBm/MHz at 5 MHz above.                              increasing linearly to a level of 27 dBm/MHz at
                                                                      the band edge.
Note:
The following formula is used to convert the equipment isotropic radiated power (eirp) to field strength:

s         1000000~/30P
                               uV/m, where P is the eirp (Watts).
     C           3


Report No.: RF181219E202—2                              Page No. 13 / 29                             Report Format Version: 6.1.1


4.1.2 Test Instruments
For radiated test:
DESCRIPTION &                                                                CALIBRATED         CALIBRATED
                                  MODEL NO.                  SERIAL NO.
MANUFACTURER                                                                 DATE               UNTIL
Test Receiver
                                 N9038A                      MY50010156      July 12, 2018      July 11, 2019
Agilent
Pre-Amplifier
                                  EMC001340                  980142          Jan. 25, 2019      Jan. 24, 2020
EMCI
Loop Antenna
                                  EM-6879                    269             Sep. 07, 2018      Sep. 06, 2019
Electro-Metrics
RF Cable                          NA                         LOOPCAB-001 Jan. 14, 2019          Jan. 13, 2020
RF Cable                          NA                         LOOPCAB-002 Jan. 14, 2019          Jan. 13, 2020
Pre-Amplifier
                                  ZFL-1000VH2B               AMP-ZFL-05      May 05, 2018       May 04, 2019
Mini-Circuits
Trilog Broadband Antenna
                                  VULB 9168                  9168-361        Nov. 22, 2018      Nov. 21, 2019
SCHWARZBECK
RF Cable                          8D                         966-3-1         Mar. 20, 2018      Mar. 19, 2019
RF Cable                          8D                         966-3-2         Mar. 20, 2018      Mar. 19, 2019
RF Cable                          8D                         966-3-3         Mar. 20, 2018      Mar. 19, 2019
Fixed attenuator
                                  UNAT-5+                    PAD-3m-3-01     Sep. 27, 2018      Sep. 26, 2019
Mini-Circuits
Horn_Antenna
                                  BBHA9120-D                 9120D-406       Nov. 25, 2018      Nov. 24, 2019
SCHWARZBECK
Pre-Amplifier
                                  EMC12630SE                 980384          Jan. 28, 2019      Jan. 27, 2020
EMCI
RF Cable                          EMC104-SM-SM-1200          160922          Jan. 28, 2019      Jan. 27, 2020
RF Cable                          EMC104-SM-SM-2000          180601          June 12, 2018      June 11, 2019
RF Cable                          EMC104-SM-SM-6000          180602          June 12, 2018      June 11, 2019
Spectrum Analyzer
                                 N9030A                      MY54490679      July 23, 2018      July 22, 2019
Keysight
Pre-Amplifier
                                  EMC184045SE                980387          Jan. 28, 2019      Jan. 27, 2020
EMCI
Horn_Antenna
                                  BBHA 9170                  BBHA9170519     Nov. 25, 2018      Nov. 24, 2019
SCHWARZBECK
RF Cable                          EMC102-KM-KM-1200 160924                   Jan. 28, 2019      Jan. 27, 2020
RF Cable                          EMC102-KM-KM-1200 160925                   Jan. 28, 2019      Jan. 27, 2020
Software                          ADT_Radiated_V8.7.08 NA                    NA                 NA
Antenna Tower & Turn Table
                                  MF-7802                    MF780208406     NA                 NA
Max-Full
Boresight Antenna Fixture         FBA-01                     FBA-SIP01       NA                 NA
Spectrum Analyzer
                                  FSV40                      100964          June 20, 2018      June 19, 2019
R&S
Power meter
                                  ML2495A                    1014008         May 09, 2018       May 08, 2019
Anritsu
Power sensor
                                  MA2411B                    0917122         May 09, 2018       May 08, 2019
Anritsu

Note:
 1. The calibration interval of the above test instruments is 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in 966 Chamber No. 3.
 3. The CANADA Site Registration No. is 20331-1
 4. Loop antenna was used for all emissions below 30 MHz.
 5. Tested Date: Jan. 29, 2019




Report No.: RF181219E02-2                     Page No. 14 / 29                         Report Format Version: 6.1.1
Reference No.: {ref-reports}


For other test items:
DESCRIPTION &                                                                 CALIBRATED CALIBRATED
                                 MODEL NO.                  SERIAL NO.
MANUFACTURER                                                                  DATE              UNTIL
Spectrum Analyzer
                                 FSV40                      100964            June 20, 2018 June 19, 2019
R&S
Fixed Attenuator
                                 MDCS18N-10                 MDCS18N-10-01 Apr. 16, 2018          Apr. 15, 2019
Mini-Circuits

Note:
 1. The calibration interval of the above test instruments is 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in 966 Chamber No. 3.
 3. The CANADA Site Registration No. is 20331-1
 4. Loop antenna was used for all emissions below 30 MHz.
 5. Tested Date: Jan. 25, 2019




Report No.: RF181219E02-2                     Page No. 15 / 29                         Report Format Version: 6.1.1
Reference No.: {ref-reports}


4.1.3      Test Procedures

For Radiated emission below 30MHz
 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
        room. The table was rotated 360 degrees to determine the position of the highest radiation.

     b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.

     c. Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
        measurement.

     d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
        from 0 degrees to 360 degrees to find the maximum reading.

     e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
        Maximum Hold Mode.
Note:
     1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
        below 30MHz.

For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.      The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.
c.      The height of antenna is varied from one meter to four meters above the ground to determine the
        maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
        make the measurement.
d.      For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
        to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
        find the maximum reading.
e.      The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
        hold mode when the test frequency is below 1 GHz.
f.      The test-receiver system was set to peak and average detect function and specified bandwidth with
        maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
        average limit, measurement with the average detector is unnecessary.


Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2.      The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
        for Peak detection (PK) at frequency above 1GHz.
3.      The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
        (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4.      All modes of operation were investigated and the worst-case emissions are reported.




Report No.: RF181219E02-2                         Page No. 16 / 29                        Report Format Version: 6.1.1
Reference No.: {ref-reports}


4.1.4    Deviation from Test Standard

 No deviation.


4.1.5    Test Setup

 For Radiated emission below 30MHz


                                                                         1m
             EUT&                           3m
             Support Units

                                  Turn Table

                80cm


                                         Ground Plane
                                         Test Receiver




  For Radiated emission 30MHz to 1GHz

                                                            Ant. Tower
                                                                          1-4m
                                                                          Variable
                                               3m
                                                10m
                EUT&
                Support Units

                                        Turn Table

                    80cm


                                           Ground Plane

                                           Test Receiver




Report No.: RF181219E02-2                    Page No. 17 / 29                 Report Format Version: 6.1.1
Reference No.: {ref-reports}


  For Radiated emission above 1GHz



                                                             Ant. Tower            1-4m
                                                                                   Variable
             EUT&                             3m
             Support Units

                                    Turn Table
                                                   Absorber

                150cm


                                           Ground Plane
                                           Test Receiver




 For the actual test configuration, please refer to the attached file (Test Setup Photo).




4.1.6    EUT Operating Conditions

a. Connected the EUT with the Laptop which is placed on remote site.
b. Controlling software (QDART_1.0.38 (Version: V3.0.210.0)) has been activated to set the EUT on specific
   status.




Report No.: RF181219E02-2                       Page No. 18 / 29                            Report Format Version: 6.1.1
Reference No.: {ref-reports}


4.1.7    Test Results
Above 1GHz Data

                                                       DETECTOR                 Peak (PK)
FREQUENCY RANGE                1GHz ~ 40GHz
                                                       FUNCTION                 Average (AV)


                    ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                      EMISSION                            ANTENNA     TABLE        RAW          CORRECTION
         FREQ.                      LIMIT     MARGIN
NO.                    LEVEL                               HEIGHT     ANGLE       VALUE           FACTOR
         (MHz)                    (dBuV/m)     (dB)
                      (dBuV/m)                               (m)     (Degree)     (dBuV)           (dB/m)
  1      4874.00       45.9 PK      74.0       -28.1        1.00 H     32           44.0              1.9
  2      4874.00       43.5 AV      54.0       -10.5        1.00 H     32           41.6              1.9
  3      7311.00       44.2 PK      74.0       -29.8        1.42 H     11           36.4              7.8
  4      7311.00       34.7 AV      54.0       -19.3        1.42 H     11           26.9              7.8
  5     11570.00       63.0 PK      74.0       -11.0        1.68 H     46           50.5             12.5
  6     11570.00       50.7 AV      54.0        -3.3        1.68 H     46           38.2             12.5
  7     17355.00       60.3 PK      68.2        -7.9        1.41 H     39           43.7             16.6
                      ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                      EMISSION                            ANTENNA     TABLE        RAW          CORRECTION
         FREQ.                      LIMIT     MARGIN
NO.                    LEVEL                               HEIGHT     ANGLE       VALUE           FACTOR
         (MHz)                    (dBuV/m)     (dB)
                      (dBuV/m)                               (m)     (Degree)     (dBuV)           (dB/m)
  1      4874.00       53.4 PK      74.0       -20.6        1.56 V     353          51.5              1.9
  2      4874.00       52.7 AV      54.0        -1.3        1.56 V     353          50.8              1.9
  3      7311.00       47.5 PK      74.0       -26.5        1.39 V     346          39.7              7.8
  4      7311.00       41.1 AV      54.0       -12.9        1.39 V     346          33.3              7.8
  5     11570.00       57.3 PK      74.0       -16.7        2.17 V     325          44.8             12.5
  6     11570.00       45.1 AV      54.0        -8.9        2.17 V     325          32.6             12.5
  7     17355.00       57.8 PK      68.2       -10.4        1.64 V     40           41.2             16.6
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. The other emission levels were very low against the limit.
   4. Margin value = Emission Level – Limit value




Report No.: RF181219E02-2                       Page No. 19 / 29                           Report Format Version: 6.1.1
Reference No.: {ref-reports}


Below 1GHz Data:
                                                      DETECTOR
FREQUENCY RANGE                9kHz ~ 1GHz                                     Quasi-Peak (QP)
                                                      FUNCTION

                    ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                      EMISSION                           ANTENNA     TABLE        RAW         CORRECTION
         FREQ.                      LIMIT    MARGIN
NO.                    LEVEL                              HEIGHT     ANGLE       VALUE          FACTOR
         (MHz)                    (dBuV/m)    (dB)
                      (dBuV/m)                              (m)     (Degree)     (dBuV)          (dB/m)
  1       30.10        33.3 QP      40.0       -6.7        2.95 H     344         43.0             -9.7
  2      125.06        32.7 QP      43.5      -10.8        2.50 H     179         42.7            -10.0
  3      225.94        37.1 QP      46.0       -8.9        2.00 H     243         47.5            -10.4
  4      406.36        32.2 QP      46.0      -13.8        1.50 H     169         36.7             -4.5
  5      499.48        36.1 QP      46.0       -9.9        1.00 H     163         38.1             -2.0
  6      610.06        37.6 QP      46.0       -8.4        1.00 H     264         37.4              0.2
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF181219E02-2                      Page No. 20 / 29                          Report Format Version: 6.1.1
Reference No.: {ref-reports}


                                                      DETECTOR
FREQUENCY RANGE                9kHz ~ 1GHz                                     Quasi-Peak (QP)
                                                      FUNCTION

                      ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                      EMISSION                           ANTENNA     TABLE        RAW         CORRECTION
         FREQ.                      LIMIT    MARGIN
NO.                    LEVEL                              HEIGHT     ANGLE       VALUE          FACTOR
         (MHz)                    (dBuV/m)    (dB)
                      (dBuV/m)                              (m)     (Degree)     (dBuV)          (dB/m)
  1       30.68        36.3 QP      40.0      -3.7         1.00 V     238         46.1             -9.8
  2       55.90        34.8 QP      40.0      -5.2         1.00 V     245         43.7             -8.9
  3      125.06        36.2 QP      43.5      -7.3         1.50 V     163         46.2            -10.0
  4      499.96        36.2 QP      46.0      -9.8         2.00 V     179         38.2             -2.0
  5      613.75        42.0 QP      46.0      -4.0         1.50 V     243         41.7              0.3
  6      875.06        37.2 QP      46.0      -8.8         2.00 V     162         32.9              4.3
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF181219E02-2                      Page No. 21 / 29                          Report Format Version: 6.1.1
Reference No.: {ref-reports}


4.2     Conducted Emission Measurement
4.2.1    Limits of Conducted Emission Measurement

                                                            Conducted Limit (dBuV)
        Frequency (MHz)
                                                Quasi-peak                              Average
          0.15 - 0.5                              66 - 56                                56 - 46
          0.50 - 5.0                                 56                                     46
          5.0 - 30.0                                 60                                     50
Note: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.


4.2.2    Test Instruments

DESCRIPTION &                                                         CALIBRATED            CALIBRATED
                               MODEL NO.         SERIAL NO.
 MANUFACTURER                                                         DATE                  UNTIL
Test Receiver
                               ESCS 30           847124/029           Oct. 24, 2018        Oct. 23, 2019
R&S
Line-Impedance
Stabilization Network (for
                               ESH3-Z5           848773/004           Oct. 22, 2018        Oct. 21, 2019
EUT)
R&S
Line-Impedance
Stabilization Network
                               ENV216            100072               June 04, 2018        June 03, 2019
(for Peripheral)
R&S
50 ohms Terminator             N/A               3                    Oct. 22, 2018        Oct. 21, 2019
RF Cable                       5D-FB             COCCAB-001           Sep. 28, 2018        Sep. 27, 2019
Fixed attenuator
                               STI02-2200-10     003                  Mar. 16, 2018        Mar. 15, 2019
EMCI
Software                       BVADT_Cond_
                                                 NA                   NA                   NA
BVADT                          V7.3.7.4

Note:
 1. The calibration interval of the above test instruments are 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in Conduction 1.
 3. Tested Date: Jan. 23, 2019




Report No.: RF181219E02-2                      Page No. 22 / 29                        Report Format Version: 6.1.1
Reference No.: {ref-reports}


                                                                                                              uces
                                                                                                              venitas



4.2.3     Test Procedures


  a.    The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
        connected to the power mains through a line impedance stabilization network (LISN). Other support
        units were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH
        of coupling impedance for the measuring instrument.
  b.    Both lines of the power mains connected to the EUT were checked for maximum conducted
        interference.
  c.    The frequency range from 150kHz to 30MHz was searched. Emission levels under (Limit — 20dB) was
        not recorded.

 Note: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi—peak detection (QP)
        and average detection (AV) at frequency 0.15MHz—30MHz.


4.2.4     Deviation from Test Standard

 No deviation.


4.2.5     Test Setup
                                    Vertical Ground
                                    Reference Plane                          / Test Receiver

                        m                                                          L___]
                                                                                o o o o
                        40cm        EUT                                      E* s o o 0




                                                         80cm
                        LISN
                                L               L1                           L
                                                         \ IN
                                                                                              1
                                                          Horizontal
                                                                     Ground
                                                                    Refere       Plane
                                                                           nce

                         Note: 1.Support units were connected to second LISN.




 For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.2.6     EUT Operating Conditions

 Same as 4.1.6.




Report No.: RF181219E202—2                       Page No. 23 / 29                           Report Format Version: 6.1.1


4.2.7    Test Results

                                                                                   Quasi-Peak (QP) /
Phase                          Line (L)                      Detector Function
                                                                                   Average (AV)

                                            Phase Of Power : Line (L)
        Frequency         Correction   Reading Value Emission Level              Limit            Margin
 No                        Factor          (dBuV)          (dBuV)               (dBuV)              (dB)
           (MHz)             (dB)       Q.P.     AV.    Q.P.      AV.        Q.P.      AV.     Q.P.      AV.
  1       0.15000           10.03      29.34   16.89   39.37     26.92      66.00    56.00    -26.63 -29.08
  2       0.17734           10.04      24.86   14.49   34.90     24.53      64.61    54.61    -29.71 -30.08
  3       0.43906           10.08      27.94   26.86   38.02     36.94      57.08    47.08    -19.06 -10.14
  4       3.41406           10.28      13.78    6.19   24.06     16.47      56.00    46.00    -31.94 -29.53
  5       9.14844           10.65      17.29    11.94  27.94     22.59      60.00    50.00    -32.06 -27.41
  6       21.28906          11.39      15.12    6.39   26.51     17.78      60.00    50.00    -33.49 -32.22
Remarks:
       1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
       2. The emission levels of other frequencies were very low against the limit.
       3. Margin value = Emission level – Limit value
       4. Correction factor = Insertion loss + Cable loss
       5. Emission Level = Correction Factor + Reading Value




Report No.: RF181219E02-2                       Page No. 24 / 29                       Report Format Version: 6.1.1
Reference No.: {ref-reports}


                                                                                   Quasi-Peak (QP) /
Phase                          Neutral (N)                   Detector Function
                                                                                   Average (AV)

                                          Phase Of Power : Neutral (N)
        Frequency         Correction   Reading Value Emission Level              Limit            Margin
 No                        Factor          (dBuV)          (dBuV)               (dBuV)              (dB)
           (MHz)             (dB)       Q.P.    AV.     Q.P.     AV.         Q.P.      AV.     Q.P.      AV.
  1       0.15000            9.94      28.55   13.70   38.49    23.64       66.00    56.00    -27.51 -32.36
  2       0.23203            9.95      15.53    0.68   25.48    10.63       62.38    52.38    -36.90 -41.75
  3       0.44297            9.98      24.89   19.48   34.87    29.46       57.01    47.01    -22.14 -17.55
  4       0.83750            9.99      12.96    5.00   22.95    14.99       56.00    46.00    -33.05 -31.01
  5       13.44922          10.74      16.07   11.04   26.81    21.78       60.00    50.00    -33.19 -28.22
  6       20.48438          11.15      14.57    7.17   25.72    18.32       60.00    50.00    -34.28 -31.68
Remarks:
       1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
       2. The emission levels of other frequencies were very low against the limit.
       3. Margin value = Emission level – Limit value
       4. Correction factor = Insertion loss + Cable loss
       5. Emission Level = Correction Factor + Reading Value




Report No.: RF181219E02-2                       Page No. 25 / 29                       Report Format Version: 6.1.1
Reference No.: {ref-reports}


4.3     Conducted Out of Band Emission Measurement
4.3.1    Limits of Conducted Out of Band Emission Measurement

Below 30dB of the highest emission level of operating band (in 100kHz Resolution Bandwidth).


4.3.2    Test Setup


                                                                  Spectrum
                  EUT
                                         Attenuator               Analyzer



4.3.3    Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.3.4    Test Procedures

MEASUREMENT PROCEDURE REF
1. Set the RBW = 100 kHz.
2. Set the VBW ≥ 300 kHz.
3. Detector = peak.
4. Sweep time = auto couple.
5. Trace mode = max hold.
6. Allow trace to fully stabilize.
7. Use the peak marker function to determine the maximum power level in any 100 kHz band segment within
   the fundamental EBW.

MEASUREMENT PROCEDURE OOBE
1. Set RBW = 100 kHz.
2. Set VBW ≥ 300 kHz.
3. Detector = peak.
4. Sweep = auto couple.
5. Trace Mode = max hold.
6. Allow trace to fully stabilize.
7. Use the peak marker function to determine the maximum amplitude level.


4.3.5    Deviation from Test Standard

No deviation.


4.3.6    EUT Operating Conditions

The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.

4.3.7    Test Results

The spectrum plots are attached on the following pages. D1 line indicates the highest level, and D2 line
indicates the 30dB offset below D1. It shows compliance with the requirement.




Report No.: RF181219E02-2                      Page No. 26 / 29                       Report Format Version: 6.1.1
Reference No.: {ref-reports}


 2.4GHz_802.11b CH6 + 5GHz_802.11a CH157
  Chain 0                                   Chain 1




  Chain 2                                   Chain 3




Report No.: RF181219E02-2             Page No. 27 / 29   Report Format Version: 6.1.1
Reference No.: {ref-reports}


5    Pictures of Test Arrangements


 Please refer to the attached file (Test Setup Photo).




Report No.: RF181219E02-2                      Page No. 28 / 29   Report Format Version: 6.1.1
Reference No.: {ref-reports}


Appendix – Information of the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                    Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF181219E02-2                     Page No. 29 / 29                  Report Format Version: 6.1.1
Reference No.: {ref-reports}



Document Created: 2019-04-11 22:10:26
Document Modified: 2019-04-11 22:10:26

© 2024 FCC.report