Test Report_co-location

FCC ID: I88EMG3425Q10A

Test Report

Download: PDF
FCCID_3792551

            FCC Co-Location Test Report
            FCC ID                 : I88EMG3425Q10A
            Equipment              : Simultaneous Dual-Band Wireless AC2200
                                     Gigabit Ethernet Gateway
            Model No.              : EMG3425-Q10A
            Brand Name             : ZyXEL
            Applicant              : ZyXEL Communications Corporation
            Address                : No. 2, Gongye E. 9th Road, Hsinchu Science
                                     Park, Hsinchu, Taiwan.
            Standard               : 47 CFR FCC Part 15.247
                                     47 CFR FCC Part 15.407
            Received Date          : Dec. 19, 2017
            Tested Date            : Jan. 16 ~ Jan. 17, 2018


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Reviewed by:                        Approved by:




      Along Chen / Assistant Manager      Gary Chang / Manager




Report No.: FR570601-07CO                                                             Page : 1 of 15
Report Version: Rev. 01


                                                         Table of Contents
1        GENERAL DESCRIPTION .................................................................................................................... 5

1.1      Information.............................................................................................................................................. 5
1.2      The Equipment List ................................................................................................................................ 6
1.3      Test Standards ....................................................................................................................................... 6
1.4      Measurement Uncertainty ...................................................................................................................... 7

2        TEST CONFIGURATION ....................................................................................................................... 8

2.1      Testing Condition ................................................................................................................................... 8
2.2      The Worst Test Modes and Channel Details ......................................................................................... 8

3        TRANSMITTER TEST RESULTS.......................................................................................................... 9

3.1      Unwanted Emissions into Restricted Frequency Bands ........................................................................ 9

4        TEST LABORATORY INFORMATION ...............................................................................................15




Report No.: FR570601-07CO                                                                                                           Page : 2 of 15
Report Version: Rev. 01


                                      Release Record
     Report No.             Version                   Description      Issued Date
 FR570601-07CO              Rev. 01   Initial issue                   Mar. 09, 2018




Report No.: FR570601-07CO                                           Page : 3 of 15
Report Version: Rev. 01


                                     Summary of Test Results
    FCC Rules                        Test Items               Measured                      Result
     15.247(d)
                                                  [dBuV/m at 3m]: 49.99MHz
     15.407(b)            Radiated Emissions                                                 Pass
                                                  35.90 (Margin -4.10dB) - QP
       15.209




Report No.: FR570601-07CO                                                       Page : 4 of 15
Report Version: Rev. 01


1              General Description
1.1            Information
This is a FCC Class II Permissive Change report (C2PC).
This report is issued as a supplementary report to original ICC report no. FR570601CO. The modifications are
concerned with following items:
           2.4G Power amplifier is changed.
           Increase output power of 5725 ~ 5850 MHz to comply with new emission limits by software setting.
           2nd source components into power portion of Non-RF part: 12V(Q1), 5V(L4, L5) and 1.2V(L17).
           Remove one adapter.


1.1.1          Specification of the Equipment under Test (EUT)
                                  802.11b/g/n: 2412 MHz ~ 2462 MHz
Operating Frequency
                                  802.11a/n/ac: 5180 MHz ~ 5240 MHz; 5745 MHz ~ 5825 MHz
                                  802.11b: DSSS (DBPSK / DQPSK / CCK)
Modulaton Type
                                  802.11a/g/n/ac: OFDM (BPSK / QPSK / 16QAM / 64QAM / 256QAM)


1.1.2          Antenna Details

    Ant.                                       Operating Frequency / Gain (dBi)
                        Type                                                                   Connector
    No.                                        2.4GHz                     5GHz
        1              Dipole                    1.53                     1.92                     UFL


1.1.3          Power Supply Type of Equipment under Test (EUT)
Power Supply Type                     12Vdc from AC adapter


1.1.4          Accessories
                                                     Accessories
 No.               Equipment          Description
                                      Brand Name: APD
                                      Model Name: WA-36A12FU
                                      Power Rating:
    1              AC adapter         I/P: 100-240Vac, 50-60Hz, 0.9A Max
                                      O/P: 12Vdc, 3A
                                      Power Line:
                                      DC 1.5m non-shielded cable with one core
    2              RJ45 cable         1.0m non-shielded cable w/o core.




Report No.: FR570601-07CO                                                                   Page : 5 of 15
Report Version: Rev. 01


1.2       The Equipment List
      Test Item        Radiated Emission
      Test Site        966 chamber 3 / (03CH03-WS)
    Tested Date        Jan. 16 ~ Jan. 17, 2018
      Instrument           Manufacturer             Model No.            Serial No.      Calibration Date      Calibration Until
 Spectrum Analyzer              R&S                   FSV40               101498          Dec. 04, 2017         Dec. 03, 2018
       Receiver                 R&S                   ESR3                101658          Nov. 20, 2017         Nov. 19, 2018
    Bilog Antenna         SCHWARZBECK               VULB9168           VULB9168-685       Apr. 28, 2017          Apr. 27, 2018
    Horn Antenna
                          SCHWARZBECK             BBHA 9120 D         BBHA 9120 D 1206    Feb. 09, 2017         Feb. 08, 2018
      1G-18G
    Horn Antenna
                          SCHWARZBECK              BBHA 9170           BBHA 9170517       Nov. 23, 2017         Nov. 22, 2018
      18G-40G
    Loop Antenna                R&S                  HFH2-Z2              100330          Nov. 13, 2017         Nov. 12, 2018
 Loop Antenna Cable        KOAX KABEL              101354-BW             101354-BW        Dec. 07, 2017         Dec. 06, 2018
     Preamplifier              EMC                  EMC02325              980187          Sep. 04, 2017         Sep. 03, 2018
     Preamplifier             Agilent                83017A             MY53270014        Aug. 21, 2017         Aug. 20, 2018
     Preamplifier              EMC                EMC184045B              980192          Aug. 22, 2017         Aug. 21, 2018
    RF cable-3M           HUBER+SUHNER           SUCOFLEX104             MY22620/4        Nov. 27, 2017         Nov. 26, 2018
    RF cable-8M           HUBER+SUHNER           SUCOFLEX104             MY32487/4        Nov. 27, 2017         Nov. 26, 2018
    RF cable-1M           HUBER+SUHNER           SUCOFLEX104             MY22624/4        Nov. 27, 2017         Nov. 26, 2018
                                                                      EMC8D-NM-NM-800
    LF cable-0.8M              EMC             EMC8D-NM-NM-800                            Nov. 27, 2017         Nov. 26, 2018
                                                                           -001
                                               EMC8D-NM-NM-300
    LF cable-3M                EMC                                        131103          Nov. 27, 2017         Nov. 26, 2018
                                                      0
                                               EMC8D-NM-NM-130
    LF cable-13M               EMC                                        131104          Nov. 27, 2017         Nov. 26, 2018
                                                     00
    Measurement
                              AUDIX                     e3               6.120210g             NA                     NA
     Software
Note: Calibration Interval of instruments listed above is one year.



1.3       Test Standards
According to the specification of EUT, the EUT must comply with following standards and KDB documents.
47 CFR FCC Part 15.247
47 CFR FCC Part 15.407
ANSI C63.10-2013
FCC KDB 558074 D01 DTS Meas Guidance v04
FCC KDB 662911 D01 Multiple Transmitter Output v02r01
FCC KDB 789033 D02 General UNII Test Procedures New Rules v02r01
FCC KDB 412172 D01 Determining ERP and EIRP v01r01




Report No.: FR570601-07CO                                                                                 Page : 6 of 15
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




1.4        Measurement Uncertainty
I1SO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test
results be included in the report. The measurement uncertainties given below are based on a 95% confidence
level (based on a coverage factor (k=2)

                                          Measurement Uncertainty
                                    Parameters                                            Uncertainty
Radiated emission         1GHz                                                             +3.66 dB
Radiated emission > 1GHz                                                                   +5.37 dB




Report No.: FR570601—07CO                                                              Page : 7 of 15
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




2          Test Configuration
2.1        Testing Condition
          Test Item                Test Site         Ambient Condition       Tested By
Radiated Emissions               O3CHO3—WS             20—24°C / 62%        Vincent Yeh
> FCC Designation No.:      TW0009
» FCC site registration No.:   390588
» IC site registration No.: 10807C—1


2.2         The Worst Test Modes and Channel Details
          Test item            Modulation Mode      Test Frequency (MHz)     Data Rate

Radiated Emissions          2.4G 11n HT20 + 5G fa       CH6 + CH157        MCS 0 + MCS 0
NOTE: The selected channel is the maximum power channel of Wi—Fi mode.




Report No.: FR570601—07CO                                                  Page : 8 of 15
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




3          Transmitter Test Results
3.1        Unwanted Emissions into Restricted Frequency Bands
3.1.1      Limit of Unwanted Emissions into Restricted Frequency Bands

                                         Restricted Band Emissions Limit
Frequency Range (MHz)|           Field Strength (uV/m)      |Field Strength (dBuV/m)|      Measure Distance (m)

         0.009~0.490                  2400/F(kHz)                   48.5 — 13.8                      300
         0.490~1.705                  24000/F(kHz)                   33.8 — 23                       30
          1.705~30.0                        30                           29                          30
             30~88                         100                           40                           3
            88~216                         150                         43.5                           3
           216~960                         200                           46                           3
          Above 960                        500                           54                           3
Note 1:
Qusai—Peak value is measured for frequency below 1GHz except for 9—90 kHz, 110—490 kHz frequency
band. Peak and average value are measured for frequency above 1GHz. The limit on average radio
frequency emission is as above table. The limit on peak radio frequency emissions is 20 dB above the
maximum permitted average emission limit
Note 2:
Measurements may be performed at a distance other than what is specified provided. When performing
measurements at a distance other than that specified, the results shall be extrapolated to the specified
distance using an extrapolation factor as below, Frequency at or above 30 MHz: 20 dB/decade Frequency
below 30 MHz: 40 dB/decade.


3.1.2       Test Procedures
1.      Measurement is made at a semi—anechoic chamber that incorporates a turntable allowing a EUT
        rotation of 360°. A continuously—rotating, remotely—controlled turntable is installed at the test site to
        support the EUT and facilitate determination of the direction of maximum radiation for each EUT
        emission frequency. The EUT is placed at test table. For emissions testing at or below 1 GHz, the table
        height is 80 cm above the reference ground plane. For emission measurements above 1 GHz, the table
        height is 1.5 m
2.       Measurement is made with the antenna positioned in both the horizontal and vertical planes of
        polarization. The measurement antenna is varied in height (1m ~4m) above the reference ground plane
        to obtain the maximum signal strength. Distance between EUT and antenna is 3 m.
3.      This investigation is performed with the EUT rotated 360°, the antenna height scanned between 1 m
        and 4 m, and the antenna rotated to repeat the measurements for both the horizontal and vertical
        antenna polarizations.
Note:
1.      120kHz measurement bandwidth of test receiver and Quasi—peak detector is for radiated emission below 1GHz.
2.      RBW=1MHz, VBW=3MHz and Peak detector is for peak measured value of radiated emission above 1GHz.
3.      RBW=1MHz, VBW=1/T and Peak detector is for average measured value of radiated emission above 1GHz.




Report No.: FR570601—07CO                                                                      Page : 9 of 15
Report Version: Rev. 01


3.1.3     Test Setup
Radiated Emissions below 1 GHz




Radiated Emissions above 1 GHz




Report No.: FR570601-07CO        Page : 10 of 15
Report Version: Rev. 01


3.1.4     Transmitter Radiated Unwanted Emissions (Below 1GHz)
Modulation                  2.4G 11n HT20 + 5G 11a         Test Freq. (MHz)       CH6 + CH157
Polarization                Horizontal




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).
Note 3: All spurious emissions below 30MHz are more than 20 dB below the limit.



Report No.: FR570601-07CO                                                           Page : 11 of 15
Report Version: Rev. 01


Modulation                  2.4G 11n HT20 + 5G 11a         Test Freq. (MHz)       CH6 + CH157
Polarization                Vertical




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).
Note 3: All spurious emissions below 30MHz are more than 20 dB below the limit.




Report No.: FR570601-07CO                                                           Page : 12 of 15
Report Version: Rev. 01


3.1.5     Transmitter Radiated Unwanted Emissions (Above 1GHz)
Modulation                  2.4G 11n HT20 + 5G 11a        Test Freq. (MHz)   CH6 + CH157
Polarization                Horizontal




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).




Report No.: FR570601-07CO                                                      Page : 13 of 15
Report Version: Rev. 01


Modulation                  2.4G 11n HT20 + 5G 11a        Test Freq. (MHz)   CH6 + CH157
Polarization                Vertical




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).




Report No.: FR570601-07CO                                                      Page : 14 of 15
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




4          Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp (EMC and Wireless Communication Laboratory), it is our definitive objective is
to institute long term, trust—based associations with our clients. The expectation we set up with our clients is
based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to
grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our
website http://www.icertifi.com.tw.


Linkou                                 Kwei Shan                            Kwei Shan Site II
Tel: 886—2—2601—1640                   Tel: 886—3—271—8666                  Tel: 886—3—271—8640
No. 30—2, Ding Fwu Tsuen, Lin          No. 3—1, Lane 6, Wen San 3rd St.,    No. 14—1, Lane 19, Wen San 3rd
Kou District, New Taipei City,         Kwei Shan District, Tao Yuan City    St., Kwei Shan District, Tao Yuan
Taiwan, R.0.C.                         333, Taiwan, R.O.C.                  City 333, Taiwan, R.O.C.

If you have any suggestion, please feel free to contact us as below information.

Tel: 886—3—271—8666
Fax: 886—3—318—0155