RF Exposure Info

FCC ID: I88C1100Z

RF Exposure Info

Download: PDF
FCCID_2599604

                                                 Report No.: FR531825




             Appendix B. Maximum Permissible Exposure




FCC ID: I88C1100Z                               Page No.   : B1 of B3


                                                                                                  Report No.: FR531825



1. Maximum Permissible Exposure
1.1. Applicable Standard

      Systems operating under the provisions of this section shall be operated in a manner that ensures that the
      public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure.
      In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a
      mobile device whereby that distance of at least 0.2 m is normally maintained between the user and the
      device.
      (A) Limits for Occupational / Controlled Exposure
                                                                                                      Averaging Time
        Frequency Range             Electric Field     Magnetic Field         Power Density (S)
                                                                                                       |E|²,|H|² or S
              (MHz)              Strength (E) (V/m)   Strength (H) (A/m)         (mW/ cm²)
                                                                                                         (minutes)
              0.3-3.0                   614                 1.63                    (100)*                   6
              3.0-30                  1842 / f             4.89 / f                (900 / f)*                6
              30-300                   61.4                 0.163                     1.0                    6
             300-1500                                                                F/300                   6
          1500-100,000                                                                   5                   6
      (B) Limits for General Population / Uncontrolled Exposure
                                                                                                      Averaging Time
        Frequency Range             Electric Field     Magnetic Field        Power Density (S)
                                                                                                       |E|²,|H|² or S
              (MHz)              Strength (E) (V/m)   Strength (H) (A/m)        (mW/ cm²)
                                                                                                         (minutes)
             0.3-1.34                  614                  1.63                    (100)*                  30
              1.34-30                  824/f                2.19/f                  (180/f)*                30
              30-300                   27.5                 0.073                     0.2                   30
             300-1500                                                               F/1500                  30
          1500-100,000                                                                1.0                   30
      Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

      E (V/m) =
                    30  P  G                   Power Density:      Pd (W/m²) =
                                                                                   E2
                        d                                                          377
      E = Electric field (V/m)
      P = Average RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)
      The formula can be changed to

      Pd =
              30  P  G
               377  d 2
      From the EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of
      the used antenna, the RF power density can be obtained.

FCC ID: I88C1100Z                                                                               Page No.   : B2 of B3


                                                                                           Report No.: FR531825


1.3. Calculated Result and Limit

      Exposure Environment: General Population / Uncontrolled Exposure
      Antenna Type : Dipole Antenna
      Conducted Power for IEEE 802.11g: 29.82 dBm
                                  Antenna     Average Output        Power       Limit of Power
       Distance     Antenna
                                   Gain           Power           Density (S)     Density (S)        Test Result
          (m)       Gain (dBi)
                                 (numeric)    (dBm)     (mW)      (mW/cm²)        (mW/cm²)
          0.2         3.70        2.3442     29.8200   959.4006   0.447662            1              Complies




FCC ID: I88C1100Z                                                                         Page No.    : B3 of B3



Document Created: 2015-04-21 10:52:16
Document Modified: 2015-04-21 10:52:16