RF Exposure Info MPE

FCC ID: I4L-BM25SD

RF Exposure Info

Download: PDF
FCCID_4471458

                                                           RF Exposure Report

                       Report No.: SA190816C17

                            FCC ID: I4L-BM25SD

                       Test Model: 124000-99

                   Series Model: GFX-350, XCN-750 (Refer to section 2.4 for more details)

                 Received Date: Aug. 16, 2019

          Date of Evaluation: Sep. 20, 2019

                     Issued Date: Sep. 25, 2019


                         Applicant: Micro Star International Co., Ltd.

                          Address: No. 69, Li-De Street, Jung He City, Taipei Hsien, R.O.C. TAIWAN


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Lin Kou Laboratories
                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan

                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, Taiwan
            FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA190816C17                                              Page No. 1 / 6                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
    2.4      Information of EUT .............................................................................................................................. 5
    2.5      Calculation Result of Maximum Conducted Power ............................................................................. 6




Report No.: SA190816C17                                              Page No. 2 / 6                                              Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA190816C17           Original Release                                   Sep. 25, 2019




Report No.: SA190816C17                     Page No. 3 / 6        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Display System

              Brand: Trimble

        Test Model: 124000-99

      Series Model: GFX-350, XCN-750

    Sample Status: Identical Prototype

          Applicant: Micro Star International Co., Ltd.

Date of Evaluation: Sep. 20, 2019

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.3 -2002



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:        Sep. 25, 2019
                                 Rona Chen / Specialist




     Approved by :                                              ,   Date:        Sep. 25, 2019
                             Dylan Chiou / Project Engineer




Report No.: SA190816C17                        Page No. 4 / 6                         Report Format Version: 6.1.1


2      RF Exposure

2.1     Limits for Maximum Permissible Exposure (MPE)

    Frequency Range            Electric Field        Magnetic Field        Power Density            Average Time
                                                                                    2
         (MHz)                Strength (V/m)         Strength (A/m)          (mW/cm )                 (minutes)
                               Limits For General Population / Uncontrolled Exposure
        0.3-1.34                   614                    1.63                  (100)*                   30
                                                                                       2
        1.34-30                   824/f                  2.19/f                (180/f )*                 30
        30-300                     27.5                  0.073                   0.2                     30
       300-1500                     …                      …                    f/1500                   30
      1500-100,000                  …                      …                     1.0                     30

f = Frequency in MHz ; *Plane-wave equivalent power density



2.2     MPE Calculation Formula

                          2
Pd = (Pout*G) / (4*pi*r )
where
                                   2
Pd = power density in mW/cm
Pout = output power to antenna in mW
G = gain of antenna in linear scale
pi = 3.1416
r = distance between observation point and center of the radiator in cm



2.3     Classification

The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.



2.4     Information of EUT


All models are listed as below.
           Brand                           Model                                       Difference
                                          GFX-350
                                         124000-99           All models are electrically identical, different model
          Trimble
                                                             names are for marketing purpose.
                                          XCN-750




Report No.: SA190816C17                              Page No. 5 / 6                             Report Format Version: 6.1.1


2.5     Calculation Result of Maximum Conducted Power

                Frequency Band    Max Power        Antenna Gain   Distance   Power Density       Limit
      Band                                                                            2                2
                    (MHz)           (dBm)              (dBi)        (cm)       (mW/cm )        (mW/cm )
      WLAN         2412-2462         23.58               2.83       20          0.087              1.00

        BT         2402-2480          5.95               2.83       20          0.002              1.00

Note:
1. Determining compliance based on the results of the compliance measurement, not taking into account
      measurement instrumentation uncertainty.


--- END ---




Report No.: SA190816C17                          Page No. 6 / 6                    Report Format Version: 6.1.1



Document Created: 2019-10-09 02:17:25
Document Modified: 2019-10-09 02:17:25

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC