Test Report BT LE

FCC ID: I4L-BM25SD

Test Report

Download: PDF
FCCID_4471437

                                                       Partial FCC Test Report

                       Report No.: RF190816C17-1

                            FCC ID: I4L-BM25SD

                       Test Model: 124000-99

                   Series Model: GFX-350, XCN-750 (Refer to section 3.1 for more details)

                 Received Date: Aug. 16, 2019

                         Test Date: Sep. 13, 2019 ~ Sep. 18, 2019

                     Issued Date: Sep. 25, 2019


                         Applicant: Micro Star International Co., Ltd.

                          Address: No. 69, Li-De Street, Jung He City, Taipei Hsien, R.O.C. TAIWAN


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Lin Kou Laboratories
                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan

                  Test Location: No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, Taiwan
            FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: RF190816C17-1                                                 Page No. 1 / 26                                    Report Format Version: 6.1.1


                                                                Table of Contents
Release Control Record .................................................................................................................................. 3
1 Certificate of Conformity ........................................................................................................................... 4
2 Summary of Test Results ........................................................................................................................... 5
    2.1 Measurement Uncertainty ..................................................................................................................... 5
    2.2 Modification Record .............................................................................................................................. 5
3 General Information ................................................................................................................................... 6
    3.1 General Description of EUT .................................................................................................................. 6
    3.2 Description of Test Modes..................................................................................................................... 7
        3.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 8
    3.3 Description of Support Units ................................................................................................................. 9
        3.3.1 Configuration of System under Test ........................................................................................... 9
    3.4 General Description of Applied Standards ............................................................................................ 9
4 Test Types and Results ............................................................................................................................ 10
    4.1 Radiated Emission and Bandedge Measurement .............................................................................. 10
        4.1.1 Limits of Radiated Emission and Bandedge Measurement ..................................................... 10
        4.1.2 Test Instruments ........................................................................................................................ 11
        4.1.3 Test Procedures ........................................................................................................................ 12
        4.1.4 Deviation from Test Standard ................................................................................................... 12
        4.1.5 Test Set Up ............................................................................................................................... 13
        4.1.6 EUT Operating Conditions ........................................................................................................ 14
        4.1.7 Test Results .............................................................................................................................. 15
    4.2 Conducted Emission Measurement .................................................................................................... 20
        4.2.1 Limits of Conducted Emission Measurement ........................................................................... 20
        4.2.2 Test Instruments ....................................................................................................................... 20
        4.2.3 Test Procedures ........................................................................................................................ 21
        4.2.4 Deviation from Test Standard ................................................................................................... 21
        4.2.5 Test Setup ................................................................................................................................. 21
        4.2.6 EUT Operating Conditions ........................................................................................................ 21
        4.2.7 Test Results .............................................................................................................................. 22
    4.3 Conducted Output Power Measurement ............................................................................................ 24
        4.3.1 Limits of Conducted Output Power Measurement.................................................................... 24
        4.3.2 Test Setup ................................................................................................................................. 24
        4.3.3 Test Instruments ....................................................................................................................... 24
        4.3.4 Test Procedures ........................................................................................................................ 24
        4.3.5 Deviation from Test Standard ................................................................................................... 24
        4.3.6 EUT Operating Conditions ........................................................................................................ 24
        4.3.7 Test Results .............................................................................................................................. 24
5 Pictures of Test Arrangements................................................................................................................ 25
Appendix – Information of the Testing Laboratories ................................................................................. 26




Report No.: RF190816C17-1                                             Page No. 2 / 26                                   Report Format Version: 6.1.1


                                           Release Control Record


 Issue No.              Description                                            Date Issued
 RF190816C17-1          Original Release                                       Sep. 25, 2019




Report No.: RF190816C17-1                        Page No. 3 / 26    Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Display System

              Brand: Trimble

        Test Model: 124000-99

      Series Model: GFX-350, XCN-750

    Sample Status: Identical Prototype

          Applicant: Micro Star International Co., Ltd.

          Test Date: Sep. 13, 2019 ~ Sep. 18, 2019

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247)
                        ANSI C63.10:2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                                ,   Date:     Sep. 25, 2019
                                 Rona Chen / Specialist




     Approved by :                                                 ,   Date:     Sep. 25, 2019
                            Dylan Chiou / Project Engineer




Report No.: RF190816C17-1                        Page No. 4 / 26                    Report Format Version: 6.1.1


                                                                                                               ooocc



2      Summary of Test Results

                                 47 CFR FCC Part 15, Subpart C (Section 15.247)

        FCC
                                   Test Item                    Result                    Remarks
       Clause
                                                                          Meet the requirement of limit.
       15.207          AC Power Conducted Emission               Pass     Minimum passing margin is —3.03 dB
                                                                          at 0.25526 MHz.
                                                                          Meet the requirement of limit.
    15.205 & 209              Radiated Emissions                 Pass     Minimum passing margin is —7.37 dB
                                                                          at 304.51 MHz.
      15.247(d)             Band Edge Measurement                 N/A     Refer to Note
      15.247(d)              Antenna Port Emission                N/A     Refer to Note
     15.247(a)(2)               6 dB Bandwidth                    N/A     Refer to Note
      15.247(b)                Conducted Power                   Pass     Meet the requirement of limit.

      15.247(e)             Power Spectral Density                N/A     Refer to Note
       15.203                Antenna Requirement                 Pass     No antenna connector is used.
Note:
1. This report is a partial report, only test item of AC Power Conducted Emission, Conducted Power and
       Radiated Emissions tests were performed for this report. Other testing data please refer to BV CPS report
       no.: RF180518C15—2 for module (Brand: MSI, Model: BM25}).
2.     Determining compliance based on the results of the compliance measurement, not taking into account
       measurement instrumentation uncertainty.

2.1      Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16—4—2:


                     Measurement                                   Frequency              Expanded Uncertainty
                                                                                                   (k=2) (+)
          Conducted Emissions at mains ports                   150 kHz ~ 30 MHz                    2.94 dB
                                                                9 kHz ~ 30 MHz                     3.04 dB
            Radiated Emissions up to 1 GHz                    30 MHz ~ 200 MHz                     2.93 dB
                                                             200 MHz ~ 1000 MHz                    2.95 dB
               .       20.                                      1 GHz ~ 18 GHz                     2.26 dB
           Radiated Emissions above 1 GHz                      78 Griz ~ 40 ariz                   7 o1 dp



2.2       Modification Record

There were no modifications required for compliance.




Report No.: RF190816C17—1                            Page No. 5 / 26                      Report Format Version: 6.1.1


3      General Information
3.1      General Description of EUT

 Product                         Display System
 Brand                           Trimble
 Test Model                      124000-99
 Series Model                    GFX-350, XCN-750
 Status of EUT                   Identical Prototype
 Power Supply Rating             12 Vdc (DC Power Supply)
 Modulation Type                 GFSK
 Transfer Rate                   1 Mbps
 Operating Frequency             2402 ~ 2480 MHz
 Number of Channel               40
 Output Power                    3.936 mW
 Antenna Type                    Monopole antenna with 2.83 dBi gain
 Antenna Connector               N/A
 Accessory Device                N/A
 Data Cable Supplied             N/A
Note:
1. The BT/WLAN module (Brand: MSI, Model: BM25) was installed in EUT.
2. All models are listed as below. (Tested model: 124000-99)
               Brand                        Model                                    Difference
                                           GFX-350
                                        124000-99              All models are electrically identical, different model
               Trimble
                                                               names are for marketing purpose.
                                           XCN-750
3. The above EUT information is declared by manufacturer and for more detailed features description,
      please refers to the manufacturer's specifications or User's Manual.




Report No.: RF190816C17-1                              Page No. 6 / 26                     Report Format Version: 6.1.1


3.2   Description of Test Modes

40 channels are provided to this EUT:
  Channel      Freq. (MHz)   Channel    Freq. (MHz)    Channel   Freq. (MHz)   Channel        Freq. (MHz)
      0            2402         10         2422           20        2442           30             2462
      1            2404         11         2424           21        2444           31             2464
      2            2406         12         2426           22        2446           32             2466
      3            2408         13         2428           23        2448           33             2468
      4            2410         14         2430           24        2450           34             2470
      5            2412         15         2432           25        2452           35             2472
      6            2414         16         2434           26        2454           36             2474
      7            2416         17         2436           27        2456           37             2476
      8            2418         18         2438           28        2458           38             2478
      9            2420         19         2440           29        2460           39             2480




Report No.: RF190816C17-1                     Page No. 7 / 26                  Report Format Version: 6.1.1


3.2.1       Test Mode Applicability and Tested Channel Detail

 EUT Configure                                 Applicable To
                                                                                                         Description
     Mode                RE1G         RE<1G              PLC                  APCM

        -                  √               √                   √                √                               -
Where           RE1G: Radiated Emission above 1 GHz                 RE<1G: Radiated Emission below 1 GHz
                PLC: Power Line Conducted Emission                   APCM: Antenna Port Conducted Measurement

Note: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on X-plane.


Radiated Emission Test (Above 1 GHz):

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure
                           Available Channel              Tested Channel               Modulation Type              Data Rate (Mbps)
      Mode

            -                    0 to 39                           0, 19, 39                GFSK                           1



Radiated Emission Test (Below 1 GHz):

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure
                           Available Channel              Tested Channel               Modulation Type              Data Rate (Mbps)
      Mode

            -                    0 to 39                              0                     GFSK                           1



Power Line Conducted Emission Test:

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure
                           Available Channel              Tested Channel               Modulation Type              Data Rate (Mbps)
      Mode

            -                    0 to 39                              0                     GFSK                           1



Antenna Port Conducted Measurement:

     This item includes all test value of each mode, but only includes spectrum plot of worst value of each
     mode.
     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure
                           Available Channel              Tested Channel               Modulation Type              Data Rate (Mbps)
      Mode

            -                    0 to 39                           0, 19, 39                GFSK                           1




Report No.: RF190816C17-1                                           Page No. 8 / 26                       Report Format Version: 6.1.1


Test Condition:
      Applicable To              Environmental Conditions                  Input Power                      Tested by

         RE1G                      25 deg. C, 65 % RH                    120 Vac, 60 Hz                    Tim Chen

         RE<1G                      25 deg. C, 65 % RH                    120 Vac, 60 Hz                    Tim Chen

          PLC                       25 deg. C, 65 % RH                    120 Vac, 60 Hz                   Thomas Wei

         APCM                       25 deg. C, 65 % RH                         12 Vdc                       Wayne Lin




3.3      Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
  No.             Product                Brand              Model No.                   Serial No.               FCC ID
 1.            DC Power Supply          Topward              33010D                       807748                    N/A


No.                                 Signal Cable Description Of The Above Support Units
 1.     N/A




3.3.1      Configuration of System under Test




                                                         EUT                      DC Power
                                                                                   Supply
                                             (Power from DC power supply)



              *Test Table




3.4      General Description of Applied Standards

The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:


FCC Part 15, Subpart C (15.247)
KDB 558074 D01 15.247 Meas Guidance v05r02
ANSI C63.10-2013


All test items have been performed and recorded as per the above standards.




Report No.: RF190816C17-1                                    Page No. 9 / 26                         Report Format Version: 6.1.1


4     Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement

Radiated emissions which fall in the restricted bands must comply with the radiated emission limits specified
as below table. Other emissions shall be at least 20 dB below the highest level of the desired power:
            Frequencies                         Field Strength                 Measurement Distance
               (MHz)                          (microvolts/meter)                     (meters)
            0.009 ~ 0.490                         2400/F (kHz)                            300
            0.490 ~ 1.705                        24000/F (kHz)                             30
            1.705 ~ 30.0                                30                                 30
               30 ~ 88                                 100                                  3
              88 ~ 216                                 150                                  3
              216 ~ 960                                200                                  3
             Above 960                                 500                                  3
Note:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
3. For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
   peak field strength of any emission shall not exceed the maximum permitted average limits, specified
   above by more than 20 dB under any condition of modulation.




Report No.: RF190816C17-1                          Page No. 10 / 26                 Report Format Version: 6.1.1


4.1.2   Test Instruments
      Description &                                                        Date of             Due Date of
                                Model No.            Serial No.
      Manufacturer                                                        Calibration          Calibration
Test Receiver
                                 N9038A             MY51210203          Mar. 18, 2019         Mar. 17, 2020
Agilent
Spectrum Analyzer
                                 N9010A             MY52220314          Dec. 13, 2018         Dec. 12, 2019
Agilent
Spectrum Analyzer
                                  FSU43                101261            Apr. 15, 2019        Apr. 14, 2020
ROHDE & SCHWARZ
Broadband Horn Antenna
                                BBHA 9170                148            Nov. 25, 2018         Nov. 24, 2019
SCHWARZBECK
HORN Antenna
                               BBHA 9120D            9120D-969          Nov. 25, 2018         Nov. 24, 2019
SCHWARZBECK
BILOG Antenna
                                VULB 9168             9168-472          Nov. 23, 2018         Nov. 22, 2019
SCHWARZBECK
Fixed Attenuator
                              MDCS18N-10          MDCS18N-10-01          Apr. 15, 2019        Apr. 14, 2020
WORKEN
Loop Antenna                    HLA 6121                45745            Jul. 01, 2019        Jun. 30, 2020
Preamplifier
                               EMC001340               980201            Oct. 12, 2018        Oct. 11, 2019
EMCI
Bluetooth Tester                   CBT                 100946           Aug. 09, 2018         Aug. 08, 2020
Preamplifier
                               EMC 012645              980115            Oct. 12, 2018        Oct. 11, 2019
EMCI
Preamplifier
                               EMC 184045              980116            Oct. 12, 2018        Oct. 11, 2019
EMCI
Preamplifier
                                EMC 330H               980112            Oct. 12, 2018        Oct. 11, 2019
EMCI
Power Meter
                                 ML2495A              1012010           Sep. 04, 2019         Sep. 03, 2020
Anritsu
Power Sensor
                                MA2411B               1315050           Sep. 04, 2019         Sep. 03, 2020
Anritsu
RF Coaxial Cable            EMC104-SM-SM-8
                                                  140811+170717          Oct. 12, 2018        Oct. 11, 2019
HUBER+SUHNNER                  000&3000
RF Coaxial Cable                                 EMC104-SM-SM-1
                             SUCOFLEX 104                                Oct. 12, 2018        Oct. 11, 2019
HUBER+SUHNNER                                      000(140807)
RF Coaxial Cable
                                  8D-FB            Cable-Ch10-01         Oct. 12, 2018        Oct. 11, 2019
Worken
Software                            E3
                                                          NA                  NA                    NA
BV ADT                           6.120103
Antenna Tower
                                MFA-440H                  NA                  NA                    NA
MF
Turn Table
                               MFT-201SS                  NA                  NA                    NA
MF
Antenna Tower &Turn
Table Controller                 MF-7802                  NA                  NA                    NA
MF


Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Chamber 10.




Report No.: RF190816C17-1                        Page No. 11 / 26                   Report Format Version: 6.1.1


4.1.3    Test Procedures

For Radiated Emission below 30 MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
     room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c. Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
     from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum
     Hold Mode.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9 kHz at frequency
     below 30 MHz.


For Radiated Emission above 30 MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30 MHz ~ 1 GHz) / 1.5 meters (for
     above 1 GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
     determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c. The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
     heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
     the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test-receiver system was set to peak and average detected function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.


Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
     Quasi-peak detection (QP) or Peak detection (PK) at frequency below 1 GHz.
2. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
     for Peak detection (PK) at frequency above 1 GHz.
3. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98 %) or 10 Hz (Duty cycle ≥ 98 %) for Average detection (AV) at frequency above 1 GHz.
     (RBW = 1 MHz, VBW = 3 kHz)
4. All modes of operation were investigated and the worst-case emissions are reported.


4.1.4    Deviation from Test Standard

No deviation.


Report No.: RF190816C17-1                          Page No. 12 / 26                   Report Format Version: 6.1.1


4.1.5   Test Set Up
 <Radiated Emission below 30 MHz>


                                                                     1m
            EUT&                       3m
            Support Units

                              Turn Table

               80 cm


                                    Ground Plane
                                    Test Receiver




 <Radiated Emission 30 MHz to 1 GHz>

                                                        Ant. Tower
                                                                      1-4m
                                                                      Variable
                                       3m
                                        10m
              EUT&
              Support Units

                                  Turn Table

                  80cm


                                       Ground Plane

                                       Test Receiver




Report No.: RF190816C17-1                   Page No. 13 / 26          Report Format Version: 6.1.1


 <Radiated Emission above 1 GHz>



                                                            Ant. Tower             1-4 m
                                                                                   Variable
            EUT&                              3m
            Support Units

                                    Turn Table
                                                   Absorber

              150 cm


                                           Ground Plane
                                           Test Receiver




 For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF190816C17-1                          Page No. 14 / 26                    Report Format Version: 6.1.1


4.1.7      Test Results

Above 1 GHz Data:
EUT Test Condition                                    Measurement Detail
Channel                     Channel 0                 Frequency Range                  1 GHz ~ 25 GHz
                                                                                       Peak (PK)
Input Power                 120 Vac, 60 Hz            Detector Function
                                                                                       Average (AV)
Environmental
                            25 deg. C, 65 % RH        Tested By                        Tim Chen
Conditions


                             Antenna Polarity & Test Distance: Horizontal at 3 m
                Emission
 Frequency                  Read Level   Factor      Limit                     Antenna      Table Angle
                  Level                                         Margin (dB)                                 Remark
   (MHz)                      (dBuV)     (dB/m)    (dBuV/m)                   Height (cm)    (Degree)
                (dBuV/m)
    2390          38.98       43.98          -5        54            -15.02      132            79          Average
    2390          48.76       53.76          -5        74            -25.24      132            79            Peak
    2402         101.51       106.51         -5                                  132            79          Average
    2402         102.88       107.88         -5                                  132            79            Peak
    4804          35.56       50.03      -14.47        54            -18.44      137            198         Average
    4804          43.85       58.32      -14.47        74            -30.15      137            198           Peak
                               Antenna Polarity & Test Distance: Vertical at 3 m
                Emission
 Frequency                  Read Level   Factor      Limit                     Antenna      Table Angle
                  Level                                         Margin (dB)                                 Remark
   (MHz)                      (dBuV)     (dB/m)    (dBuV/m)                   Height (cm)    (Degree)
                (dBuV/m)
    2390          39.9         44.9          -5        54            -14.1       201            212         Average
    2390          48.39       53.39          -5        74            -25.61      201            212           Peak
    2402          96.25       101.25         -5                                  201            212         Average
    2402          97.66       102.66         -5                                  201            212           Peak
    4804          35.44       49.91      -14.47        54            -18.56      152            233         Average
    4804          44.01       58.48      -14.47        74            -29.99      152            233           Peak
Remarks:
1. Emission Level = Read Level + Factor
   Margin value = Emission level – Limit value
2. 2402 MHz: Fundamental frequency.
3. The emission levels of other frequencies were very low against the limit.




Report No.: RF190816C17-1                         Page No. 15 / 26                       Report Format Version: 6.1.1


EUT Test Condition                                    Measurement Detail
Channel                     Channel 19                Frequency Range                  1 GHz ~ 25 GHz
                                                                                       Peak (PK)
Input Power                 120 Vac, 60 Hz            Detector Function
                                                                                       Average (AV)
Environmental
                            25 deg. C, 65 % RH        Tested By                        Tim Chen
Conditions


                             Antenna Polarity & Test Distance: Horizontal at 3 m
               Emission
 Frequency                  Read Level   Factor      Limit                     Antenna      Table Angle
                 Level                                          Margin (dB)                                 Remark
   (MHz)                      (dBuV)     (dB/m)    (dBuV/m)                   Height (cm)    (Degree)
               (dBuV/m)
    2440        101.33        106.31      -4.98                                  152            80          Average
    2440        102.39        107.37      -4.98                                  152            80            Peak
    4880         35.85        49.93      -14.08        54            -18.15      169            215         Average
    4880         44.44        58.52      -14.08        74            -29.56      169            215           Peak
                               Antenna Polarity & Test Distance: Vertical at 3 m
               Emission
 Frequency                  Read Level   Factor      Limit                     Antenna      Table Angle
                 Level                                          Margin (dB)                                 Remark
   (MHz)                      (dBuV)     (dB/m)    (dBuV/m)                   Height (cm)    (Degree)
               (dBuV/m)
    2440         94.9         99.88       -4.98                                  245            216         Average
    2440         96.1         101.08      -4.98                                  245            216           Peak
    4880         35.72         49.8      -14.08        54            -18.28      176            100         Average
    4880         44.98        59.06      -14.08        74            -29.02      176            100           Peak
Remarks:
1. Emission Level = Read Level + Factor
   Margin value = Emission level – Limit value
2. 2440 MHz: Fundamental frequency.
3. The emission levels of other frequencies were very low against the limit.




Report No.: RF190816C17-1                         Page No. 16 / 26                       Report Format Version: 6.1.1


EUT Test Condition                                    Measurement Detail
Channel                     Channel 39                Frequency Range                  1 GHz ~ 25 GHz
                                                                                       Peak (PK)
Input Power                 120 Vac, 60 Hz            Detector Function
                                                                                       Average (AV)
Environmental
                            25 deg. C, 65 % RH        Tested By                        Tim Chen
Conditions


                             Antenna Polarity & Test Distance: Horizontal at 3 m
               Emission
 Frequency                  Read Level   Factor      Limit                     Antenna      Table Angle
                 Level                                          Margin (dB)                                 Remark
   (MHz)                      (dBuV)     (dB/m)    (dBuV/m)                   Height (cm)    (Degree)
               (dBuV/m)
    2480         98.48        103.33      -4.85                                  119            78          Average
    2480         99.74        104.59      -4.85                                  119            78            Peak
   2483.5        39.15         44         -4.85        54            -14.85      119            78          Average
   2483.5        47.78        52.63       -4.85        74            -26.22      119            78            Peak
    4960         35.86        49.75      -13.89        54            -18.14      142            184         Average
    4960         44.48        58.37      -13.89        74            -29.52      142            184           Peak
                               Antenna Polarity & Test Distance: Vertical at 3 m
               Emission
 Frequency                  Read Level   Factor      Limit                     Antenna      Table Angle
                 Level                                          Margin (dB)                                 Remark
   (MHz)                      (dBuV)     (dB/m)    (dBuV/m)                   Height (cm)    (Degree)
               (dBuV/m)
    2480         95.01        99.86       -4.85                                  214            211         Average
    2480         96.16        101.01      -4.85                                  214            211           Peak
   2483.5        38.13        42.98       -4.85        54            -15.87      214            211         Average
   2483.5        48.58        53.43       -4.85        74            -25.42      214            211           Peak
    4960         35.96        49.85      -13.89        54            -18.04      164            223         Average
    4960         44.63        58.52      -13.89        74            -29.37      164            223           Peak
Remarks:
1. Emission Level = Read Level + Factor
   Margin value = Emission level – Limit value
2. 2480 MHz: Fundamental frequency.
3. The emission levels of other frequencies were very low against the limit.




Report No.: RF190816C17-1                         Page No. 17 / 26                       Report Format Version: 6.1.1


9 kHz ~ 30 MHz Data:
The amplitude of spurious emissions attenuated more than 20 dB below the permissible value is not required
to be report.


30 MHz ~ 1 GHz Worst-Case Data:
EUT Test Condition                                   Measurement Detail
Channel                     Channel 0                Frequency Range          30 MHz ~ 1 GHz
                                                                              Peak (PK)
Input Power                 120 Vac, 60 Hz           Detector Function
                                                                              Quasi-peak (QP)
Environmental
                            25 deg. C, 65 % RH       Tested By                Tim Chen
Conditions

Horizontal




Vertical




Report No.: RF190816C17-1                        Page No. 18 / 26                Report Format Version: 6.1.1


                             Antenna Polarity & Test Distance: Horizontal at 3 m
               Emission
 Frequency                  Read Level   Factor      Limit                     Antenna      Table Angle
                 Level                                          Margin (dB)                                Remark
   (MHz)                      (dBuV)     (dB/m)    (dBuV/m)                   Height (cm)    (Degree)
               (dBuV/m)
   43.58         27.75         44.7      -16.95        40            -12.25      193            15           Peak
   304.51        38.63        55.15      -16.52        46            -7.37       202           144           Peak
   577.08        33.91        43.42       -9.51        46            -12.09      196           155           Peak
   775.93        37.23         41.7       -4.47        46            -8.77       178           308           Peak
   900.09        36.06        40.67       -4.61        46            -9.94       199           101           Peak
   953.44        34.99        37.99        -3          46            -11.01      188           227           Peak
                               Antenna Polarity & Test Distance: Vertical at 3 m
               Emission
 Frequency                  Read Level   Factor      Limit                     Antenna      Table Angle
                 Level                                          Margin (dB)                                Remark
   (MHz)                      (dBuV)     (dB/m)    (dBuV/m)                   Height (cm)    (Degree)
               (dBuV/m)
    39.7         28.21        45.42      -17.21        40            -11.79      103           121           Peak
   199.75        27.71         47.5      -19.79       43.5           -15.79      101           299           Peak
   399.57        27.93        41.97      -14.04        46            -18.07      131           177           Peak
   499.48        33.38        43.95      -10.57        46            -12.62      123           169           Peak
   729.37        35.88        42.44       -6.56        46            -10.12      114            68           Peak
   899.12        35.53        40.15       -4.62        46            -10.47      126           122           Peak
Remarks:
1. Emission Level = Read Level + Factor
   Margin value = Emission level – Limit value
2. The emission levels of other frequencies were very low against the limit.




Report No.: RF190816C17-1                         Page No. 19 / 26                      Report Format Version: 6.1.1


4.2     Conducted Emission Measurement
4.2.1    Limits of Conducted Emission Measurement

                                                          Conducted Limit (dBuV)
        Frequency (MHz)
                                            Quasi-Peak                                  Average
           0.15 - 0.5                          66 - 56                                   56 - 46
           0.50 - 5.0                            56                                        46
           5.0 - 30.0                            60                                        50

Note: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.


4.2.2    Test Instruments

        Description &                                                      Date of              Due Date of
                                Model No.             Serial No.
        Manufacturer                                                      Calibration           Calibration
Test Receiver
                                   ESCI                  100613          Dec. 10, 2018          Dec. 09, 2019
ROHDE & SCHWARZ
RF signal cable
                                   5D-FB           Cable-cond1-01        Sep. 05, 2019          Sep. 04, 2020
Woken
LISN
ROHDE & SCHWARZ                   ENV216                 101826          Feb. 21, 2019          Feb. 20, 2020
(EUT)
LISN
ROHDE & SCHWARZ                  ESH3-Z5                 100311          Aug. 22, 2019          Aug. 21, 2020
(Peripheral)
Software                      BV ADT_Cond_
                                                           NA                 NA                     NA
ADT                              V7.3.7.4

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-12040.




Report No.: RF190816C17-1                         Page No. 20 / 26                   Report Format Version: 6.1.1


                                                                                                              ooocc



4.2.3    Test Procedures

a.    The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected
     to the power mains through a line impedance stabilization network (LISN). Other support units were
     connected to the power mains through another LISN. The two LISNs provide 50 ohm/50 uH of coupling
     impedance for the measuring instrument.
     Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
     The frequency range from 150 kHz to 30 MHz was searched. Emission levels under (Limit — 20 dB) was
     not recorded.


Note: The resolution bandwidth and video bandwidth of test receiver is 9 kHz for quasi—peak detection (QP)
and average detection (AV) at frequency 0.15 MHz — 30 MHz.


4.2.4    Deviation from Test Standard
No deviation.


4.2.5     Test Setup
                                Vertical Ground
                                 Reference Plane                              / Test Receiver

                                                                                    E——41
                                                                                    6 6 0 o
                                 EUT                                           M\“" 6 0 0 o




                                              | |       80cm                  | |


                                              L1                              L1
                                                                       N                        T
                                                        \ Horizontal Ground
                                                                       Reference Plane

                       Note: 1.Support units were connected to second LISN.
                            2.Both of LISNs (AMN) are 80 cm from EUT and at least 80
                              from other units and other metal planes



4.2.6    EUT Operating Conditions

a.   Placed the EUT on the testing table.
b.   Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF190816C17—1                           Page No. 21 / 26                     Report Format Version: 6.1.1


                                                                                                                         ommert
                                                                                                                         [vexiras)]



4.2.7   Test Results
CONDUCTED WORST—CASE DATA
                                                             Detector Function &             .
Frequency Range             150kHz ~ 30MHz                   Resolution             Suis"Pefv(QQI_q
                                                             Bandwidth                verage (AV),            9kHz
                                                             Environmental             s
Input Power                 120Vac, 60Hz                     Conditions             25°C, 65%RH

Tested by                   Thomas Wei                       Test Date              2019/9/16

                                             Phase Of Power : Line (L)
        Frequency      |Correction|   Reading Value        Emission Level             Limit                          Margin
 No                         Factor         (dBuV)               (dBuV)               (dBuV)                      (dB)
           (MHz)             (dB)      Q.P.      AV.        Q.P.      LVA        Q.P.       AV.             QP.        AV.
  1       0.15391            9.67     47.74     37.47      57.41     47.14      65.79     55.79            —8.38      —8.65
  2       0.20865            9.66     50.04     35.20      59.70     44.86      63.26     53.26            —3.56      —8.40
  3       0.25526            9.67     48.88     36.32      58.55     45.99      61.58     51.58            —3.03      —5.59
  4       0.28294            9.67     47.72     34.42      57.39     44.09      60.73     50.73            —3.34      —6.64
  5       0.34941            9.68     41.49     30.51      51.17     40.19      58.98     48.98            —7.81      —8.79
  6       0.42370            9.69     36.26     24.27      45.95     33.96      57.38     47.38            1143      —13.42
Remarks:
          1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value


                                                                             PM Trace ——
                                                                             ar timit |.——
                                                                             cay Limt |ow—




Report No.: RF190816C17—1                             Page No. 22 / 26                           Report Format Version: 6.1.1


                                                                                                                               ommert
                                                                                                                               [vexiras)]



                                                             Detector Function &                      .
Frequency Range             150kHz ~ 30MHz                   Resolultion                    S:;i;e(i{(vg(}&éz
                                                             Bandwidth                                           "
Input Power                 120Vac, 60Hz                     Eg‘r’]'é‘i’fi”omn:”‘a'          25°C, 65%RH
Tested by                   Thomas Wei                       Test Date                      2019/9/16


                                           Phase Of Power : Neutral (N)
        Frequency      |Correction|   Reading Value        Emission Level                      Limit                     Margin
 No                         Factor         (dBuV)              (dBuV)                        (dBuV)                         (dB)
           (MHz)             (dB)      Q.P.      AV.        QP.      AV.                 Q.P.       AV.               QP.         AV.
  1       0.16569            9.64     42.81     28.42      5245     38.06               65417     §547               1272       —17.11
  2       0.18910            9.64     48.52     35.56      58.16    45.20               64.08     54.08               —5.92      —8.88
  3       0.21647            9.64     48.67     34.27      58.31    43.91               62.95     52.95               —4.64      —9.04
  4       0.24215            9.64     46.55     35.27      5619     44.91               62.02     52.02               —5.83      —7.11
  5       0.26730            9.65     45.91     33.06      55.56    42.71               61.20     51.20               —5.64      —8.49
  6       0.34941            9.65     88.76     24.71      48.41    34.36               58.98     48.98              —10.57     —14.62
Remarks:
          1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value


                                                                                     io Trace _
                                                                                     ar timit |.=—
                                                                                     Cay Limit |.o—




Report No.: RF190816C17—1                             Page No. 23 / 26                                    Report Format Version: 6.1.1


4.3     Conducted Output Power Measurement
4.3.1        Limits of Conducted Output Power Measurement

For systems using digital modulation in the 2400–2483.5 MHz bands: 1 Watt (30 dBm)


4.3.2        Test Setup




               EUT                                Power Sensor                    Power Meter
                                   Attenuator




4.3.3        Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.3.4        Test Procedures

A peak power sensor was used on the output port of the EUT. A power meter was used to read the response
of the peak power sensor. Record the power level.


4.3.5        Deviation from Test Standard

No deviation.


4.3.6        EUT Operating Conditions

The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.


4.3.7        Test Results

                      Frequency             Peak Power             Peak Power        Limit
  Channel                                                                                           Pass / Fail
                        (MHz)                  (mW)                  (dBm)          (dBm)
        0                   2402                3.936                      5.95      30                 Pass
        19                  2440                3.784                      5.78      30                 Pass
        39                  2480                3.926                      5.94      30                 Pass




Report No.: RF190816C17-1                               Page No. 24 / 26              Report Format Version: 6.1.1


5    Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: RF190816C17-1                         Page No. 25 / 26   Report Format Version: 6.1.1


Appendix – Information of the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                    Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF190816C17-1                        Page No. 26 / 26              Report Format Version: 6.1.1



Document Created: 2019-10-09 02:05:05
Document Modified: 2019-10-09 02:05:05

© 2025 FCC.report