Test report Zigbee

FCC ID: I38KHUB210ZB

Test Report

Download: PDF
FCCID_4441166

                         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE190800701

         1        Cover Page
                                          FCC REPORT
                                                       (ZIGBEE)

Applicant:                             Aztech Technologies Pte Ltd

Address of Applicant:                  31, Ubi Road 1, #01-05 Singapore 408694, SINGAPORE

Equipment Under Test (EUT)

    Product Name:                      ZigBee Hub

    Model No.:                         KHUB-210-ZB

    Trade mark:

FCC ID:                                I38KHUB210ZB

Applicable standards:                  FCC CFR Title 47 Part 15 Subpart C Section 15.247

Date of sample receipt:                06 Aug., 2019

Date of Test:                          06 Aug., to 28 Aug., 2019

Date of report issued:                 29 Aug., 2019

Test Result:                           PASS *

*   In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE190800701


2      Version
      Version No.                             Date                                  Description
            00                          29 Aug., 2019                                 Original




    Tested by:                                                           Date:          29 Aug., 2019

                                        Test Engineer


    Reviewed by:                                                         Date:          29 Aug., 2019

                                      Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 2 of 39


                                                                                                                       Report No: CCISE190800701

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT AND TEST MODE ................................................................................................................... 6
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.5         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.6         LABORATORY FACILITY.......................................................................................................................................... 6
    5.7         LABORATORY LOCATION ....................................................................................................................................... 6
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 8
    6.2     CONDUCTED EMISSIONS ....................................................................................................................................... 9
    6.3     CONDUCTED OUTPUT POWER ............................................................................................................................ 12
    6.4     OCCUPY BANDWIDTH .......................................................................................................................................... 14
    6.5     POWER SPECTRAL DENSITY ............................................................................................................................... 16
    6.6     BAND EDGE ......................................................................................................................................................... 18
       6.6.1 Conducted Emission Method...................................................................................................................... 18
       6.6.2 Radiated Emission Method ......................................................................................................................... 20
    6.7     SPURIOUS EMISSION ........................................................................................................................................... 25
       6.7.1 Conducted Emission Method...................................................................................................................... 25
       6.7.2 Radiated Emission Method ......................................................................................................................... 27
7       TEST SETUP PHOTO ........................................................................................................................................ 32
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 34




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                             Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                      Page 3 of 39


                                                                             Report No: CCISE190800701

 4      Test Summary
                Test Items                             Section in CFR 47                 Result
          Antenna requirement                          15.203 & 15.247 (c)                Pass
  AC Power Line Conducted Emission                            15.207                      Pass
     Conducted Peak Output Power                           15.247 (b)(3)                  Pass
        6dB Emission Bandwidth
                                                           15.247 (a)(2)                  Pass
        99% Occupied Bandwidth
         Power Spectral Density                             15.247 (e)                    Pass
                Band Edge                                   15.247 (d)                    Pass
           Spurious Emission                             15.205 & 15.209                  Pass
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                        Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 4 of 39


                                                                              Report No: CCISE190800701

5      General Information
5.1 Client Information
       Applicant:                       Aztech Technologies Pte Ltd
       Address:                         31, Ubi Road 1, #01-05 Singapore 408694, SINGAPORE
        Manufacturer:                   Aztech Technologies Pte Ltd
        Address:                        31, Ubi Road 1, #01-05 Singapore 408694, SINGAPORE
        Factory:                        Aztech Communication Device (DG) LTD
        Address:                        Jiu Jiang Shui Village, Chang Ping Town, 523500 Dong Guan City,
                                        Guang Dong Province, PEOPLE’S REPUBLIC OF CHINA

5.2 General Description of E.U.T.
       Product Name:                    ZigBee Hub
       Model No.:                       KHUB-210-ZB
       Operation Frequency:             2405MHz~2480MHz (IEEE 802.15.4)
       Channel numbers:                 16 for (IEEE 802.15.4)
       Channel separation:              5 MHz
       Modulation technology:
                                        OQPSK
       (IEEE 802.15.4)
       Data speed(IEEE 802.15.4): 250kbps
       Antenna Type:                    PCB antenna
       Antenna gain:                    1.5 dBi
       Test Sample Condition:           The applicant provided engineering samples for staying in continuously
                                        transmitting for testing.


 Operation Frequency each of channel for IEEE 802.15.4
    Channel         Frequency      Channel        Frequency      Channel   Frequency    Channel      Frequency
       1            2405MHz            5          2425MHz            9     2445MHz         13        2465MHz
       2            2410MHz            6          2430MHz           10     2450MHz         14        2470MHz
       3            2415MHz            7          2435MHz            11    2455MHz         15        2475MHz
       4            2420MHz            8          2440MHz           12     2460MHz         16        2480MHz
 Note:
 1. Channel 1, 8 & 16 selected for IEEE 802.15.4 as Lowest, Middle and Highest channel.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 5 of 39


                                                                                Report No: CCISE190800701

5.3 Test environment and test mode
 Operating Environment:
     Temperature:                    24.0 C
     Humidity:                       54 % RH
     Atmospheric Pressure:           1010 mbar
 Test mode:
     Transmitting mode               Keep the EUT in continuous transmitting with modulation
 The sample was placed 0.8m (below 1GHz)/1.5m (above 1GHz) above the ground plane of 3m chamber.
 Measurements in both horizontal and vertical polarities were performed. During the test, each emission was
 maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis
 (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables,
 rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The
 emissions worst-case are shown in Test Results of the following pages. Duty cycle setting during the
 transmission is 100% with maximum power setting for all modulations.

5.4 Description of Support Units
      Manufacturer             Description                Model                     S/N             FCC ID/DoC
              /                  Adapter         TEKA006-0501200JPU                  /                    /
          Lenovo                    PC               ThinkPad E450         PF-OKTSQQ 16/06              DoC

5.5 Measurement Uncertainty
                    Parameters                                              Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                      ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                      ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                     ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                       ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                      ±2.88 dB (k=2)

5.6 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
           FCC - Designation No.: CN1211
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
          ISED – CAB identifier.: CN0021
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been Registered
       by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
       No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of testing.
       The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.7 Laboratory Location
       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
       Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
       Bao’an District, Shenzhen, Guangdong, China
       Tel: +86-755-23118282, Fax: +86-755-23116366
       Email: info@ccis-cb.com, Website: http://www.ccis-cb.com
Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 6 of 39


                                                                                  Report No: CCISE190800701



5.8 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer            Model No.           Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                 9m*6m*6m                966         07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK             FMZB1519B              00044         03-18-2019         03-17-2020
   BiConiLog Antenna         SCHWARZBECK              VULB9163                497         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK             BBHA9120D                916         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK             BBHA9120D               1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK             BBHA 9170           BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software            AUDIX                    E3                            Version: 6.110919b
     Pre-amplifier                HP                   8447D             2944A09358       03-18-2019         03-17-2020
     Pre-amplifier                CD                  PAP-1G18              11804         03-18-2019         03-17-2020
   Spectrum analyzer        Rohde & Schwarz            FSP30               101454         03-18-2019         03-17-2020
   Spectrum analyzer        Rohde & Schwarz            FSP40               100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070       03-18-2019          03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458       03-18-2019          03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5      03-18-2019          03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE      03-18-2019          03-17-2020
    RF Switch Unit             MWRFTEST                MW200                  N/A            N/A                N/A
    Test Software              MWRFTEST               MTS8200                           Version: 2.0.0.0


 Conducted Emission:
                                                                                         Cal. Date          Cal. Due date
   Test Equipment             Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189       03-18-2019           03-17-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731        03-18-2019           03-17-2020
        LISN                    CHASE                 MN2050D               1447        03-18-2019           03-17-2020
        LISN                Rohde & Schwarz           ESH3-Z5            8438621/010    07-21-2019           07-20-2020
       Cable                      HP                   10503A                N/A        03-18-2019           03-17-2020
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 7 of 39


                                                                              Report No: CCISE190800701

6      Test results and Measurement Data
6.1 Antenna requirement:
        Standard requirement:           FCC Part 15 C Section 15.203 /247(b)
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(b) (4) requirement:
        (4) The conducted output power limit specified in paragraph (b) of this section is based on the use of
        antennas with directional gains that do not exceed 6 dBi. Except as shown in paragraph (c) of this
        section, if transmitting antennas of directional gain greater than 6 dBi are used, the conducted output
        power from the intentional radiator shall be reduced below the stated values in paragraphs (b)(1),
        (b)(2), and (b)(3) of this section, as appropriate, by the amount in dB that the directional gain of the
        antenna exceeds 6 dBi.
       E.U.T Antenna:
       The Zigbee antenna is an PCB antenna which cannot replace by end-user, the best-case gain of the
       antenna is 1.5 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 8 of 39


                                                                              Report No: CCISE190800701

6.2 Conducted Emissions
       Test Requirement:                FCC Part 15 C Section 15.207
       Test Method:                     ANSI C63.10:2013
       Test Frequency Range:            150 kHz to 30 MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9 kHz, VBW=30 kHz, Sweep time=auto
       Limit:                              Frequency range                          Limit (dBuV)
                                                (MHz)                  Quasi-peak                Average
                                               0.15-0.5                  66 to 56*               56 to 46*
                                                 0.5-5                      56                      46
                                                 5-30                       60                      50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure:                  1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network (L.I.S.N.). This provides a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refer to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Hopping mode
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 9 of 39


                                                                               Report No: CCISE190800701

Measurement Data:
Product name:               ZigBee Hub                        Product model:      KHUB-210-ZB

Test by:                    Carey                             Test mode:          ZIGBEE Tx mode

Test frequency:             150 kHz ~ 30 MHz                  Phase:              Line

Test voltage:               AC 120 V/60 Hz                    Environment:        Temp: 22.5℃        Huni: 55%




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 10 of 39


                                                                               Report No: CCISE190800701


Product name:               ZigBee Hub                        Product model:      KHUB-210-ZB

Test by:                    Carey                             Test mode:          ZIGBEE Tx mode

Test frequency:             150 kHz ~ 30 MHz                  Phase:              Neutral

Test voltage:               AC 120 V/60 Hz                    Environment:        Temp: 22.5℃       Huni: 55%




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 11 of 39


                                                                               Report No: CCISE190800701

6.3 Conducted Output Power
       Test Requirement:                FCC Part 15 C Section 15.247 (b)(3)
       Test Method:                     ANSI C63.10:2013 and KDB 558074
       Limit:                           30dBm
       Test setup:




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed


Measurement Data:
                               Maximum Conducted Output Power
         Test CH                                                              Limit(dBm)              Result
                                          (dBm)
          Lowest                                  6.38
           Middle                                 6.04                          30.00                  Pass
          Highest                                 5.34




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 12 of 39


                                                                                                                                      Report No: CCISE190800701

Test plot as follows:
                                                                                        * RBW   3 MHz    Marker 1 [T1 ]
                                                                                        * VBW   10 MHz               6.38 dBm
                                         Ref    17 dBm              * Att   20 dB        SWT 2.5 ms           2.404660000 GHz

                                               Offset    7 dB

                                         10                                         1
                                                                                                                                A


                                  1 PK
                                         0
                                  MAXH
                                                                                                                                LVL

                                         -10



                                         -20



                                         -30



                                         -40                                                                                    3DB




                                         -50



                                         -60



                                         -70



                                         -80

                                         Center 2.405 GHz                           1 MHz/                        Span 10 MHz




                                  Date: 17.AUG.2019             14:43:49


                                                                            Lowest channel


                                                                                        * RBW   3 MHz    Marker 1 [T1 ]
                                                                                        * VBW   10 MHz               6.04 dBm
                                         Ref    17 dBm              * Att   20 dB        SWT 2.5 ms           2.439600000 GHz

                                               Offset    7 dB

                                         10                                         1
                                                                                                                                A


                                  1 PK
                                         0
                                  MAXH
                                                                                                                                LVL

                                         -10



                                         -20



                                         -30



                                         -40                                                                                    3DB




                                         -50



                                         -60



                                         -70



                                         -80

                                         Center 2.44 GHz                            1 MHz/                        Span 10 MHz




                                  Date: 17.AUG.2019             14:44:52


                                                                            Middle channel


                                                                                        * RBW   3 MHz    Marker 1 [T1 ]
                                                                                        * VBW   10 MHz               5.34 dBm
                                         Ref    17 dBm              * Att   20 dB        SWT 2.5 ms           2.479440000 GHz

                                               Offset    7 dB

                                         10
                                                                                1                                               A


                                  1 PK
                                         0
                                  MAXH
                                                                                                                                LVL

                                         -10



                                         -20



                                         -30



                                         -40                                                                                    3DB




                                         -50



                                         -60



                                         -70



                                         -80

                                         Center 2.48 GHz                            1 MHz/                        Span 10 MHz




                                  Date: 17.AUG.2019             14:45:08


                                                                            Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                 Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                Page 13 of 39


                                                                               Report No: CCISE190800701

6.4 Occupy Bandwidth
       Test Requirement:                FCC Part 15 C Section 15.247 (a)(2)
       Test Method:                     ANSI C63.10:2013 and KDB 558074
       Limit:                           >500kHz
       Test setup:




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed


Measurement Data:
         Test CH               6dB Emission Bandwidth (MHz)                Limit(kHz)             Result
          Lowest                               1.65
          Middle                               1.66                          >500                 Pass
         Highest                               1.68
         Test CH                99% Occupy Bandwidth (MHz)                 Limit(kHz)             Result
          Lowest                               2.66
          Middle                               2.64                           N/A                  N/A
         Highest                               2.61




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                           Page 14 of 39


CCIS                                                                                            Report No: CCISE190800701

Test plot as follows:
                                6dB EBW                                                           99% OBW
  ® se    on ues




  dare: a7.w0.0000 ies                                           ontes ar aus.zors   resares

                              Lowest channel                                                    Lowest channel




  eare: a7.w0.0009 reseniee                                      ontes ar aus.zors   resarice

                              Middle channel                                                    Middle channel




  dare: a7.w0.0000 resoce                                        ontes ar aus.zors   rmsariss

                              Highest channel                                                   Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                              Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                             Page 15 of 39


                                                                              Report No: CCISE190800701

6.5 Power Spectral Density
       Test Requirement:                FCC Part 15 C Section 15.247 (e)
       Test Method:                     ANSI C63.10:2013 and KDB 558074
       Limit:                           8 dBm
       Test setup:




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed


Measurement Data:
           Test CH                 Power Spectral Density (dBm)            Limit(dBm)             Result
           Lowest                                2.44
            Middle                               2.23                         8.00                 Pass
           Highest                               1.63




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                           Page 16 of 39


CCIS                                                                               Report No: CCISE190800701

Test plots as follow:




                                  orte: in ago.zore resi ds
                                                                 Lowest channel




                                  ertes in age.zore resi o0

                                                                 Middle channel




                                  orte: i1 ags.zore   ressocse

                                                                 Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 17 of 39


                                                                                Report No: CCISE190800701

6.6 Band Edge
6.6.1 Conducted Emission Method
       Test Requirement:                FCC Part 15 C Section 15.247 (d)
       Test Method:                     ANSI C63.10:2013 and KDB 558074
       Limit:                           In any 100 kHz bandwidth outside the frequency band in which the spread
                                        spectrum intentional radiator is operating, the radio frequency power that
                                        is produced by the intentional radiator shall be at least 20 dB below that in
                                        the 100 kHz bandwidth within the band that contains the highest level of
                                        the desired power, based on either an RF conducted or a radiated
                                        measurement.
       Test setup:




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 18 of 39


CCIS                                                                                             Report No: CCISE190800701

Test plots as follow:

                    & ree        17 gan                  2o ao
                                                                      «naw 100 kn
                                                                      «vaw 200 kn
                                                                       sur 225 ne
                                                                                    marker i (ri d
                                                                                              ~50.07 dan
                                                                                         2.20¢«52000 onz




                             ~
                            stare 2.30 ons                       107 meny                 stop 2.107 onz




                    Date:    17.AUG.2019      14:52:39


                                                            Lowest channel



                                                                                    marker i (rid
                                                                                              —is.23 dan
                                                                                         2.483s00000 onz




                            stare 2.i7e ons                  2.2 miz/                       stop 2.5 on




                    Date: 17.AUG.2019         14:53:28

                                                            Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                               Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                              Page 19 of 39


                                                                              Report No: CCISE190800701

6.6.2     Radiated Emission Method
        Test Requirement:               FCC Part 15 C Section 15.205 and 15.209
        Test Method:                    ANSI C63.10: 2013 and KDB 558074
        Test Frequency Range:           2.3GHz to 2.5GHz
        Test Distance:                  3m
        Receiver setup:                  Frequency          Detector        RBW           VBW           Remark
                                                             Peak           1MHz          3MHz        Peak Value
                                        Above 1GHz
                                                             RMS            1MHz          3MHz       Average Value
        Limit:                                Frequency             Limit (dBuV/m @3m)              Remark
                                                                            54.00                Average Value
                                             Above 1GHz
                                                                            74.00                 Peak Value
        Test Procedure:                 1. The EUT was placed on the top of a rotating table 1.5 meters above
                                            the ground at a 3 meter camber. The table was rotated 360 degrees
                                            to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                            antenna, which was mounted on the top of a variable-height antenna
                                            tower.
                                        3. The antenna height is varied from one meter to four meters above
                                            the ground to determine the maximum value of the field strength.
                                            Both horizontal and vertical polarizations of the antenna are set to
                                            make the measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst
                                            case and then the antenna was tuned to heights from 1 meter to 4
                                            meters and the rota table was turned from 0 degrees to 360 degrees
                                            to find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                            Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10 dB lower than
                                            the limit specified, then testing could be stopped and the peak values
                                            of the EUT would be reported. Otherwise the emissions that did not
                                            have 10 dB margin would be re-tested one by one using peak, quasi-
                                            peak or average method as specified and then reported in a data
                                            sheet.
        Test setup:




        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 20 of 39


CCIS                                                                                        Report No: CCISE190800701



 Product Name:                       ZigBee Hub                             Product model:          KHUB—210—ZB

 Test By:                            YT                                     Test mode:              ZIGBEE Tx mode

 Test Channel:                       Lowest channel                         Polarization:           Vertical

 Test Voltage:                       AC 120V/60Hz                           Environment:            Temp: 24°C    Huni: 57%


    110 Level (dBuVim})


    100



     §8                                                                                                    FCC PART15(£;)\


     60                                                                                        taa
             w€ong‘ls,          wA        ueNY¥ n xi                              Ausrea~Whut" afe                    (AV)
                                                                                                          d



     40



     20



          02310          2320                                 2350                                                      2407
                                                                Frequency (MHz)

                                 Readintenna          Cable Preamp                Limit      Over
                         Freq   Level Factor            Loss Factor      Level     Line     Limit Remark

                                                                     dB dBu¥,/m dBu¥/m         dB

     1.      2390,.000           22.27]    21.07       4.69      0. 00   §55.71   74.00 —18. 29 Peak
     2       2390.000            12.44     27.07       4.69      0.00    45.88    54.00 —8.12 Average



 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                           Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 21 of 39


CCIS                                                                                       Report No: CCISE190800701


Product Name:               ZigBee Hub                                 Product model:           KHUB—210—ZB

Test By:                    YT                                         Test mode:               ZIGBEE Tx mode

Test Channel:               Lowest channel                             Polarization:            Horizontal

Test Voltage:               AC 120V/60Hz                               Environment:             Temp: 24°C         Huni: 57%


     110 Level (dBuV/im)


     100



      89                                                                                                     FCC PART 15     (PK)


      60                                                                                                     x
           [+~**us 2     poyprarvirni ons    w00 Pubeant sufhant‘he ermimeithtutiorceitTsd se   dA           .QL           (AV)



      40



      20



          G2310   2320                                      2350                                                            2407
                                                              Frequency (MHz)

                            Readintenna             Cable Preamp                  Limit     Over
                  Freq     Level Factor               Loss Factor       Level       Line   Linit Remark

            _____NHz dBu¥ dB/m —db _ dB dBuV/m dBu¥/m                                           dB_
      1      2390.000      21.81            27.08    4.69      0. 00    55.26     74.00 —18.74 Peak
      2      2390.000      10.78            27.08    4.69      0.00     44.23     54.00 —9.77 Average


Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 22 of 39


CCIS                                                                                   Report No: CCISE190800701


 Product Name:              ZigBee Hub                                 Product model:              KHUB—210—ZB

 Test By:                   YT                                         Test mode:                  ZIGBEE Tx mode

 Test Channel:              Highest channel                            Polarization:               Vertical

 Test Voltage:              AC 120V/60Hz                               Environment:                Temp: 24°C     Huni: 57%


      110 Level (dBuVim)

      100



       $0 /v\                                                                                           FCC PART 15 (PK)

                                    1
       S9                            kc

       40


       20


        0
            2478                                                                                                      2500
                                                        Frequency (MHz)

                            Readintenna         Cable Preamp                   Limit      Over
                   Freq    Level Factor          Loss Factor        Level       Line     Limit Remark

                                                               dB dBu¥/m dBu¥/n               dB

       1       2483.500    26.80        27.36    4.81       0. 00    60.67     74.00 —13.33 Peak
       2       2483.500    16.42        27.36    4.81       0.00     50.28     54.00 —3.71 Average


 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 23 of 39


c c I s                                                                              Report No: CCISE190800701



Product Name:             ZigBee Hub                            Product model:             KHUB—210—ZB

Test By:                  YT                                    Test mode:                ZIGBEE Tx mode

Test Channel:             Highest channel                       Polarization:              Horizontal

Test Voltage:             AC 120V/60Hz                          Environment:              Temp: 24°C            Huni: 57%


    110 Level (dBuV/im)


    100



      80
                                                                                                        FCC PART 15 (PK)
                                  x%
      68                             Mfi&%

      40


      20


         "3ara                                                                                                       2500
                                                        Frequency (MHz)

                           Readintenna        Cable Preamp                 Limit      Over
                 Freq     Level Factor          Loss Factor      Level      Line     Limit Remark

                  MHz      dBu¥        dB/n      dB        dB dBu¥/m dBu¥/m               dB

     1     2483.500       31.43    27.35       4.81      0.00    65.29     74.00     —8.71 Feak
     2      2483.500      18.63    27.35       4.81      0.00    52.49     54.00     —1.51 Average


Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 24 of 39


                                                                                Report No: CCISE190800701

6.7     Spurious Emission
6.7.1     Conducted Emission Method
        Test Requirement:               FCC Part 15 C Section 15.247 (d)
        Test Method:                    ANSI C63.10:2013 and KDB 558074
        Limit:                          In any 100 kHz bandwidth outside the frequency band in which the spread
                                        spectrum intentional radiator is operating, the radio frequency power that
                                        is produced by the intentional radiator shall be at least 20 dB below that in
                                        the 100 kHz bandwidth within the band that contains the highest level of
                                        the desired power, based on either an RF conducted or a radiated
                                        measurement.
        Test setup:




        Test Instruments:               Refer to section 5.8 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 25 of 39


CCIS                                                                             Report No: CCISE190800701

Test plot as follows:
                                                                Lowest channel




                                   oetes (rowws aoie iescs

                                                                SOMHz~25GHz


                                                                Middle channel




                                   oetes i7 us aote   issine

                                                                SOMHz~25GHz


                                                             Highest channel




                                   oetes (rowus aoie iesseien

                                                                30OMHz~25GHz


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                           Page 26 of 39


                                                                                Report No: CCISE190800701

 6.7.2 Radiated Emission Method
       Test Requirement:                FCC Part 15 C Section 15.205 and 15.209
       Test Method:                     ANSI C63.10:2013
       Test Frequency Range:            9kHz to 25GHz
       Test Distance:                   3m
       Receiver setup:                     Frequency       Detector         RBW        VBW             Remark
                                          30MHz-1GHz      Quasi-peak      120KHz     300KHz       Quasi-peak Value
                                                            Peak           1MHz        3MHz           Peak Value
                                          Above 1GHz
                                                            RMS            1MHz        3MHz         Average Value
       Limit:                                   Frequency           Limit (dBuV/m @3m)              Remark
                                              30MHz-88MHz                    40.0               Quasi-peak Value
                                             88MHz-216MHz                    43.5               Quasi-peak Value
                                            216MHz-960MHz                    46.0               Quasi-peak Value
                                              960MHz-1GHz                    54.0               Quasi-peak Value
                                                                             54.0                Average Value
                                               Above 1GHz
                                                                             74.0                 Peak Value
       Test Procedure:                  1.    The EUT was placed on the top of a rotating table 0.8m(below
                                              1GHz)/1.5m(above 1GHz) above the ground at a 3 meter camber.
                                              The table was rotated 360 degrees to determine the position of the
                                              highest radiation.
                                        2.    The EUT was set 3 meters away from the interference-receiving
                                              antenna, which was mounted on the top of a variable-height antenna
                                              tower.
                                        3.    The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                        4.    For each suspected emission, the EUT was arranged to its worst
                                              case and then the antenna was tuned to heights from 1 meter to 4
                                              meters and the rota table was turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                        5.    The test-receiver system was set to Peak Detect Function and
                                              Specified Bandwidth with Maximum Hold Mode.
                                        6.    If the emission level of the EUT in peak mode was 10 dB lower than
                                              the limit specified, then testing could be stopped and the peak values
                                              of the EUT would be reported. Otherwise the emissions that did not
                                              have 10 dB margin would be re-tested one by one using peak, quasi-
                                              peak or average method as specified and then reported in a data
                                              sheet.
       Test setup:                      Below 1GHz




                                        Above 1GHz

Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 27 of 39


                                                                              Report No: CCISE190800701




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found
                                           the Y-axis is the worst case.
                                        2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz in
                                           this report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 28 of 39


CCIS                                                                                   Report No: CCISE190800701

Measurement Data (worst case):
Below 1GHz:

 Product Name:                  ZigBee Hub                            Product model:               KHUB—210—ZB

 Test By:                       YT                                    Test mode:                   ZIGBEE Tx mode

 Test Frequency:                30 MHz ~ 1 GHz                        Polarization:                Vertical

 Test Voltage:                  AC 120V/60Hz                          Environment:                 Temp: 24°C       Huni: 57%


           Level (dBuVim)
      80

      70

      60
                                                                                                          FCC PART 15.247
      50

      40

      30

      20

      10


           30              50                    100                200                             500                1000
                                                          Frequency (MHz)

                             Read&ntenna       Cable Preamp                 Limit      Over
                   Freq     Level Factor         Loss Factor      Level       Line    Limit Remark

                    MHz         dBu¥    dB/n       db _     dB dBu¥/m dBu¥/n             dB               CCC

      1          31.955     41.23      10.84     0.86    29.97    22.95     40.00 —17.05      qP
      2          99.878     42.51      12.41     194     29B.55   21.35     43.50—16.17       9P
      3         125.886     42.40      10.47     2.24.   29.35    25.16     43.50 —17.74      gP
      4         308. 913    35.26      13.79     2.97°   S8.47    23.55     46.00 —22.45      gF
      5         §97.223     44.63      19.44     3.94    28.95    39.06     46.00 —6.94       QP
      &         842.130     36.49      22.44     4.22    28.03    35.12     46.00 —10.88      qP



 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 29 of 39


c c I s                                                                                     Report No: CCISE 190800701


 Product Name:               ZigBee Hub                                    Product model:           KHUB—210—2B

 Test By:                    YT                                           Test mode:                ZIGBEE Tx mode

 Test Frequency:             30 MHz ~ 1 GHz                                Polarization:            Horizontal

 Test Voltage:               AC 120V/60Hz                                  Environment:             Temp: 24°C       Huni: 57%


      so Level (dBuV/im)


      70

      60
                                                                                                          FCC PART 15.247
      50

      40

      30

      20

      10


           30           50                     100                       200                        500                1000
                                                             Frequency (MHz)

                              Readintenna        Cable Preamp                      Linit      Over
                    Freq     Level Factor          Loss Factor           Level       Line    Limit Remark

                """MHz       dBu¥ dB/m — db _ dB dBuV/m dBuV¥/m                                dB
       1          31.955     42.10    10. 84         D.85      29.907:    25.82    40.00 —16. 18     gF
       2          70. 832    44.36     $.37          1.54      29.71      24.56    40.00 —15.44      qP
       3         203.523     .42.31   10.16          2.81T     2881       21.13    43.50.—16.37      QP
       4         299. 316    47.85    13.60          2.94      28.45      35.94    46.00 —10.06      qP
       5         597.223     40.63    19.44          3.94      28.95      35.06    46.00 —10.94      QP
       6         896.997     38.75    22.51          3.1%:     21.88;     31.1L    465.00. —S8.Sg    QP


 Remark:
 1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                           Project No.: CCISE1908007
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 30 of 39


                                                                                    Report No: CCISE190800701

Above 1GHz
                                             Test channel: Lowest channel
                                                 Detector: Peak Value
                  Read       Antenna        Cable       Preamp                                     Over
 Frequency                                                            Level       Limit Line
                  Level       Factor        Loss         Factor                                    Limit    Polarization
   (MHz)                                                            (dBuV/m)      (dBuV/m)
                 (dBuV)       (dB/m)         (dB)         (dB)                                     (dB)
  4810.00        49.85         30.85        6.80       41.81       45.69            74.00         -28.31      Vertical
  4810.00        48.36         30.85        6.80       41.81       44.20            74.00         -29.80     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp                                       Over
 Frequency                                                         Level          Limit Line
                  Level       Factor        Loss       Factor                                      Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)       (dB)                                       (dB)
  4810.00         42.25        30.85        6.80       41.81       38.09            54.00         -15.91      Vertical
  4810.00         43.39        30.85        6.80       41.81       39.23            54.00         -14.77     Horizontal



                                              Test channel: Middle channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp                                       Over
 Frequency                                                          Level         Limit Line
                  Level       Factor        Loss       Factor                                      Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)       (dB)                                       (dB)
  4880.00         50.47        31.20        6.86       41.84       46.69            74.00         -27.31      Vertical
  4880.00         49.86        31.20        6.86       41.84       46.08            74.00         -27.92     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp                                       Over
 Frequency                                                          Level         Limit Line
                  Level       Factor        Loss       Factor                                      Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)       (dB)                                       (dB)
  4880.00         43.36        31.20        6.86       41.84       39.58            54.00         -14.42      Vertical
  4880.00         42.58        31.20        6.86       41.84       38.80            54.00         -15.20     Horizontal



                                              Test channel: Highest channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable      Preamp                                      Over
 Frequency                                                          Level         Limit Line
                  Level       Factor        Loss        Factor                                     Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)        (dB)                                      (dB)
  4960.00         52.26        31.63        6.91        41.87       48.93           74.00         -25.07      Vertical
  4960.00         53.48        31.63        6.91        41.87       50.15           74.00         -23.85     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable      Preamp                                      Over
 Frequency                                                          Level         Limit Line
                  Level       Factor        Loss        Factor                                     Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)        (dB)                                       (dB)
  4960.00         49.63        31.63        6.91        41.87       46.30           54.00          -7.70      Vertical
  4960.00         48.51        31.63        6.91        41.87       45.18           54.00          -8.82     Horizontal
 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1908007
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 31 of 39



Document Created: 2019-09-02 15:31:21
Document Modified: 2019-09-02 15:31:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC