DTS Test Report REV2

FCC ID: I28-ZBRZQ3BT

Test Report

Download: PDF
FCCID_4136055

RF TEST
REPORT

Report No.: FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
Supersede Report No.: FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev2.0

 Applicant                             :      Zebra Technologies Corporation
 Host Product Name                     :      Thermal Printer
 Module Model No.                             ZQ3BT
 Host Model No.                           : ZT610, ZT620
                                              47 CFR 15.247
 Test Standard                            :
                                              RSS247 Issue 2, 2017
                                              ANSI C63.10: 2013
 Test Method                              : RSS-Gen Issue 5, 2018
                                              558074 D01 DTS Meas Guidance v05
 FCC ID                                   : I28-ZBRZQ3BT
 IC                                       : 3798B-ZBRZQ3BT
 Dates of test                            : 12/10/2018 – 12/19/2018
 Issue Date                               : 01/04/2019
 Test Result                              : ☒ Pass             ☐ Fail
 Equipment complied with the specification        [X]
 Equipment did not comply with the specification [ ]




 This Test Report is Issued Under the Authority of:




                      Shuo Zhang                                                      Chen Ge
                     Test Engineer                                               Engineer Reviewer

                                                  Issued By:
                                             SIEMIC Laboratories
                                  775 Montague Expressway, Milpitas, 95035 CA




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                     Test report No.       FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                     Page                  2 of 18




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
           Country/Region                  Accreditation Body                                        Scope
                 USA                            FCC, A2LA                                 EMC, RF/Wireless, Telecom
              Canada                         IC, A2LA, NIST                               EMC, RF/Wireless, Telecom
               Taiwan                       BSMI, NCC, NIST                                EMC, RF, Telecom, Safety
             Hong Kong                         OFTA, NIST                                     RF/Wireless, Telecom
              Australia                        NATA, NIST                                  EMC, RF, Telecom, Safety
               Korea                         KCC/RRA, NIST                              EMI, EMS, RF, Telecom, Safety
               Japan                     VCCI, JATE, TELEC, RFT                            EMI, RF/Wireless, Telecom
               Mexico                    NOM, COFETEL, Caniety                         Safety, EMC, RF/Wireless, Telecom
               Europe                           A2LA, NIST                                 EMC, RF, Telecom, Safety
                Israel                          MOC, NIST                                  EMC, RF, Telecom, Safety


                                    Accreditations for Product Certifications
                Country                      Accreditation Body                                      Scope
                  USA                          FCC TCB, NIST                                   EMC, RF, Telecom
                Canada                          IC FCB, NIST                                   EMC, RF, Telecom
               Singapore                          iDA, NIST                                    EMC, RF, Telecom
                  EU                                 NB                                EMC & Radio Equipment Directive (RED)
                 Japan                         MIC (RCB 208)                                       RF, Telecom
               Hong Kong                       OFTA (US002)                                        RF, Telecom


          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                           Test report No.           FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                                           Page                      3 of 18




CONTENTS
1      REPORT REVISION HISTORY .......................................................................................................................................4
2      EXECUTIVE SUMMARY.................................................................................................................................................5
3      CUSTOMER INFORMATION ..........................................................................................................................................5
4      TEST SITE INFORMATION ............................................................................................................................................5
5      MODIFICATION .............................................................................................................................................................5
6      EUT INFORMATION ......................................................................................................................................................6
     6.1    EUT Description ........................................................................................................................................................6
     6.2    Radio Description ......................................................................................................................................................6
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION .........................................................................7
     7.1    Supporting Equipment ...............................................................................................................................................7
     7.2    Cabling Description ...................................................................................................................................................7
     7.3    Test Software Description ..........................................................................................................................................7
8      TEST SUMMARY ...........................................................................................................................................................8
9      MEASUREMENT UNCERTAINTY ...................................................................................................................................9
10          MEASUREMENTS, EXAMINATION AND DERIVED RESULTS .................................................................................. 10
     10.1       Antenna Requirement.......................................................................................................................................... 10
     10.2       Radiated Spurious Emissions below 1GHz ............................................................................................................ 11
     10.3       Radiated Spurious Emissions between 1GHz – 25GHz .......................................................................................... 13
ANNEX A. TEST INSTRUMENT ........................................................................................................................................... 16
ANNEX B. SIEMIC ACCREDITATION ................................................................................................................................... 17




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                          Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.   FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                              Page              4 of 18




1   Report Revision History
                                                    Report
                Report No.                                                       Description               Issue Date
                                                    Version
   FCC_IC_RF_SL18102402-ZBR-062_BLE                  None                         Original                 12/19/2018
FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev1.0               1.0                      Update EUT info             12/27/2018
FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev2.0               2.0                  Change Radio Description        01/03/2019
FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0               3.0                    Update Antenna Info           01/04/2019




     775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                         Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.       FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                               Page                  5 of 18




 2    Executive Summary

The purpose of this test program was to demonstrate compliance of following product
  Company:                  Zebra Technologies Corporation
  Host Product Name:        Thermal Printer
  Host Model No.:           ZT610, ZT620
  Module Model No.          ZQ3BT

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with
the Stipulated Standard listed on 1st page.


 3    Customer information
  Applicant Name                          Zebra Technologies Corporation
  Applicant Address                       3 Overlook Point, Lincolnshire, IL 60069
  Manufacturer Name                       Zebra Technologies Corporation
  Manufacturer Address                    3 Overlook Point, Lincolnshire, IL 60069



 4    Test site information

  Lab performing tests                    SIEMIC Laboratories
  Lab Address                             775 Montague Expressway, Milpitas, CA 95035
  FCC Test Site No.                       881796
  IC Test Site No.                        4842D-2
  VCCI Test Site No.                      A0133


 5    Modification
                  Index                           Item                           Description                      Note
                     -                              -                                     -                         -




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                  Test report No.    FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                  Page               6 of 18




 6     EUT Information
 6.1    EUT Description

  Host Product Name                          Thermal Printer
  Host Model No.                             ZT610, ZT620
  Module Model No.                           ZQ3BT
  Trade Name                                 Zebra Technologies Corporation
  Serial No.                                 76J184300386, 76J184400121
  Input Power                                100-240V, 50-60Hz
  Power Adapter Manu/Model                   N/A, internal PSU
  Power Adapter SN                           N/A, internal PSU
  Product Hardware version                   N/A
  Date of EUT received                       12/01/2018
  Equipment Class/ Category                  DTS, DSS
  Port/Connectors                            USB, USB host x2, Gig-Ethernet, RS232, Parallel
                                             Only model ZT620 is tested as worst case. ZT610 and ZT620
  Remark
                                             have the same internal power supply and control PCB


 6.2    Radio Description
Bluetooth LE:

              Radio Type                                                        Bluetooth LE
             Radio Module                                                          ZQ3BT
         Operating Frequency                                                  2402MHz-2480MHz
              Modulation                                                          DSSS (LE)
           Channel Spacing                                                        2MHz (LE)
             Antenna Type                                                            Chip
             Antenna Gain                                                          1.69 dBi
        Antenna Connector Type                                                       N/A
                                                                                  4.72 dBm
       Maximum conducted power                                   See FCC IC_SL17060501-ZBR-021_BLE_Rev2.0 pg24
                Maximum EIRP                                                        6.41 dBm




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                    Test report No.         FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                    Page                    7 of 18




 7      Supporting Equipment/Software and cabling Description
 7.1       Supporting Equipment

                  Supporting Equipment
      Item                                           Model                    Serial Number                   Manufacturer        Note
                      Description
       1                 Laptop                 ThinkPad T420s                        N/A                        Lenovo            -




 7.2       Cabling Description

                              Connection Start                  Connection Stop                        Length / shielding Info
           Name                                                                                                                   Note
                             From        I/O Port              To           I/O Port                  Length (m)     Shielding
           USB               EUT          I/O Port           Laptop           USB                         2          Unshielded    -



7.3        Test Software Description

       Test Item                         Software                                              Description
       RF Testing                      Zebra Toolbox                     Set the EUT to transmit continuously in diferent test mode




             775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                              Test report No.      FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                              Page                 8 of 18




 8       Test Summary

             Test Item                       Test standard                               Test Method/Procedure                        Pass / Fail
                                      FCC             15.203           FCC                     ANSI C63.10 – 2013                    ☒ Pass
        Antenna Requirement
                                       IC                -               IC             558074 D01 DTS Meas Guidance v05             ☐ N/A
                                      FCC             15.205           FCC                      ANSI C63.10:2013                     ☒ Pass
  Restricted Band of Operation
                                       IC          RSS Gen 8.10          IC             558074 D01 DTS Meas Guidance v05             ☐ N/A
                                      FCC            15.207(a)          FCC                       ANSI C63.10:2013                   ☒ Pass*
      AC Conducted Emissions
                                       IC          RSS Gen 8.8           IC                     RSS Gen Issue 5: 2018                ☐ N/A

DTS Band Requirement
             Test Item                       Test standard                               Test Method/Procedure                        Pass / Fail
                                        -               -                 -                               -                          ☒ Pass*
     99% Occupied Bandwidth
                                       IC          RSS Gen 6.6           IC                     RSS Gen Issue 5: 2018                ☐ N/A
                                      FCC          15.247(a)(2)         FCC                                                          ☒ Pass*
           6dB Bandwidth                                                                558074 D01 DTS Meas Guidance v05
                                       IC         RSS247 (5.2.1)         IC                                                          ☐ N/A

      Band Edge and Radiated          FCC            15.247(d)          FCC                     ANSI C63.10:2013                     ☒ Pass
        Spurious Emissions                                                              558074 D01 DTS Meas Guidance v05             ☐ N/A
                                       IC          RSS247 (5.5)          IC
                                      FCC            15.247(b)          FCC                                                          ☒ Pass*
           Output Power                                                                 558074 D01 DTS Meas Guidance v05
                                       IC         RSS247 (5.4.4)         IC                                                          ☐ N/A
                                                                                                                                     ☐ Pass
  Receiver Spurious Emissions          IC         RSS Gen (4.8)          IC                     RSS Gen Issue 5: 2018
                                                                                                                                     ☒ N/A
                                      FCC            15.247(e)          FCC                                  -                       ☐ Pass
        Antenna Gain > 6 dBi
                                       IC                -               IC                                  -                       ☒ N/A
                                      FCC            15.247(e)          FCC                                                          ☒ Pass*
       Power Spectral Density                                                           558074 D01 DTS Meas Guidance v05
                                      IC        RSS247 (5.2.2)          IC                                                           ☐ N/A
                                     FCC            15.247(i)          FCC                              -                             ☐ Pass
      RF Exposure requirement
                                      IC         RSS Gen(5.5)           IC                    RSS Gen Issue 5: 2018                   ☒ N/A
                      1. All measurement uncertainties do not take into consideration for all presented test results.
                      2. The applicant shall ensure frequency stability by showing that an emission is maintained within the band of operation
     Remark
                           under all normal operating conditions as specified in the user’s manual.
                      3. Pass* : Please refer to FCC IC_SL17060501-ZBR-021-BLE_Rev2.0 test report.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                    Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.    FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                              Page               9 of 18




9   Measurement Uncertainty

                                                       Emissions

            Test Item                    Frequency Range                          Description                        Uncertainty
                                                                Confidence level of approximately 95% (in the
     AC Conducted Emissions               150KHz – 30MHz         case where distributions are normal), with a          ±3.5dB
                                                                            coverage factor of 2
                                                                Confidence level of approximately 95% (in the
    RF conducted measurement              150KHz – 40GHz         case where distributions are normal), with a         ±0.95dB
                                                                            coverage factor of 2
                                                                Confidence level of approximately 95% (in the case
    Radiated Spurious Emissions             30MHz – 1GHz         where distributions are normal), with a coverage      ±6dB
                                                                   factor of 2 (for EUTs < 0.5m X 0.5m X 0.5m)
                                                                Confidence level of approximately 95% (in the case
    Radiated Spurious Emissions             1GHz – 40GHz         where distributions are normal), with a coverage      ±6dB
                                                                   factor of 2 (for EUTs < 0.5m X 0.5m X 0.5m)




     775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.    FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                 Page               10 of 18




10 Measurements, Examination and Derived Results
10.1 Antenna Requirement

 Spec            Requirement                                                                                        Applicable
                 An intentional radiator shall be designed to ensure that no antenna other than that furnished
                 by the responsible party shall be used with the device.

                 Antenna requirement must meet at least one of the following:
   §15.203                                                                                                               ☒
                 a) Antenna must be permanently attached to the device.
                 b) The antenna must use a unique type of connector to attach to the device.
                 c) Device must be professionally installed. The installer shall be responsible for ensuring that
                 the correct antenna is employed by the device.

    Remark       The EUT uses a Chip antenna that is permanently attached to the board which meets the requirement.

    Result       ☒ PASS             ☐ FAIL




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                      Test report No.      FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                      Page                 11 of 18



 10.2 Radiated Spurious Emissions below 1GHz
Requirement(s):

 Spec                   Item   Requirement                                                                                Applicable
                               Except higher limit as specified elsewhere in other section, the emissions from the
                               low-power radio-frequency devices shall not exceed the field strength levels
                               specified in the following table and the level of any unwanted emissions shall not
                               exceed the level of the fundamental emission. The tighter limit applies at the band
 47CFR§15.247(d)               edges                                                                                            ☒
                         a)
   RSS247 (5.5)                          Frequency range (MHz)                          Field Strength (uV/m)
                                                 30 – 88                                         100
                                                88 – 216                                         150
                                                216 960                                          200
                                               Above 960                                         500




     Test Setup




                        1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                        2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                  Maximization of the emissions, was carried out by rotating the EUT, changing the antenna
                                  polarization, and adjusting the antenna height in the following manner:
                                  a.         Vertical or horizontal polarisation (whichever gave the higher emission level over a full
     Procedure                               rotation of the EUT) was chosen.
                                  b.         The EUT was then rotated to the direction that gave the maximum emission.
                                  c.         Finally, the antenna height was adjusted to the height that gave the maximum emission.
                        3.        A Quasi-peak measurement was then made for that frequency point.
                        4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                  measured.
                        The EUT was scanned up to 1GHz. Both horizontal and vertical polarities were investigated. The results
        Remark
                        show only the worst case.
        Result          ☒ Pass            ☐ Fail


Test Data      ☒ Yes (See below)            ☐ N/A

Test Plot      ☒ Yes (See below)            ☐ N/A
Test was done by Shuo Zhang at 10m chamber.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                    Test report No.         FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                    Page                    12 of 18




Radiated Emission Test Results (Below 1GHz)

            Test specification             Below 1GHz
                                           Temp (°C):                                                     23
      Environmental Conditions:            Humidity (%)                                                   46
                                           Atmospheric (mbar):                                           1018
             Mains Power:                  120VAC, 60Hz                                                             Result     Pass
              Tested by:                   Shuo Zhang
              Test Date:                   12/12/2018
              Remarks:                     BLE, Middle Channel




                                                     Quasi Max Measurements


Frequency     Raw       Cable       AF       Level     Measurement      Pol           Hgt          Azt     Limit     Margin    Pass
   MHz        dBuV      Loss        dB      dBuV/m        Type         (V/H)          cm           Deg    dBuV/m      dB       /Fail

 913.06         38       15.9     -12.54     41.35      Quasi Max          V          137          102      46        -4.65    Pass
 724.11       36.77     15.19      -15.1     36.86      Quasi Max          V          100          13       46        -9.14    Pass
  30.00       24.37     11.12     -12.08      23.4      Quasi Max          V          105          281      40        -16.6    Pass
 254.42       46.78     12.96     -24.21     35.53      Quasi Max          H          104          12       46       -10.47    Pass
 733.91       32.28     15.17     -15.09     32.36      Quasi Max          V          165          28       46       -13.64    Pass
 816.97       29.03     15.52     -14.22     30.33      Quasi Max          V          137          100      46       -15.67    Pass


Note: Both horizontal and vertical polarities were investigated. The results above show only the worst case.

          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                          Test report No.    FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                          Page               13 of 18


   10.3 Radiated Spurious Emissions between 1GHz – 25GHz
  Requirement(s):
Spec                        Item          Requirement                                                                           Applicable
                                          For non-restricted band, In any 100 kHz bandwidth outside the frequency band in
                                          which the spread spectrum or digitally modulated intentional radiator is operating,
                                          the radio frequency power that is produced by the intentional radiator shall be at
                                          least 20 dB or 30dB below that in the 100 kHz bandwidth within the band that                 ☒
                                 a)
                                          contains the highest level of the desired power, determined by the measurement
  47CFR§15.247(d),                        method on output power to be used. Attenuation below the general limits
    RSS247(A8.5)                          specified in § 15.209(a) is not required
                                           ☐ 20 dB down           ☒ 30 dB down
                                          or restricted band, emission must also comply with the radiated emission limits
                                 b)                                                                                                    ☒
                                          specified in 15.209




       Test Setup




                            1.            The EUT was switched on and allowed to warm up to its normal operating condition.
                            2.            The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                          Maximization of the emissions, was carried out by rotating the EUT, changing the antenna polarization,
                                          and adjusting the antenna height in the following manner:
                                          a.        Vertical or horizontal polarisation (whichever gave the higher emission level over a full
       Procedure                                    rotation of the EUT) was chosen.
                                          b.        The EUT was then rotated to the direction that gave the maximum emission.
                                          c.        Finally, the antenna height was adjusted to the height that gave the maximum emission.
                            3.            An average measurement was then made for that frequency point.
                            4.            Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                          measured.

                            The EUT was scanned up to 40GHz. Both horizontal and vertical polarities were investigated. The results
        Remark
                            show only the worst case.

         Result             ☒ Pass                ☐ Fail

  Test Data       ☒ Yes (See below)             ☐ N/A

  Test Plot       ☐ Yes (See below)             ☒ N/A


  Test was done by Shuo Zhang at 10m chamber.



              775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                      Visit us at: www.siemic.com; Follow us at:


                                                                   Test report No.         FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                   Page                    14 of 18




Radiated Emission Test Results (Above 1GHz)
Above 1GHz-25GHz – BLE-2402MHz
Frequency      Raw      Cable      AF        Level     Measurement      Pol      Height           Azt       Limit    Margin    Pass
   MHz         dBuV     Loss       dB       dBuV/m        Type         (V/H)      cm              Deg      dBuV/m     dB       /Fail

1285.725       52.4     2.14      -5.98      48.56      Peak Max          V          136          285        74      -25.44    Pass
4804.46        47.99     4.1      -0.93      51.17      Peak Max          H          102              48     74      -22.84    Pass
3307.089       41.19    3.49       -1.6      43.09      Peak Max          V          231          286        74      -30.92    Pass
1285.725       30.09    2.14      -5.98      26.25    Average Max         V          136          285        54      -27.75    Pass
4804.46        39.09     4.1      -0.93      42.27    Average Max         H          102              48     54      -11.73    Pass
3307.089       29.14    3.49       -1.6      31.03    Average Max         V          231          286        54      -22.97    Pass

Above 1GHz-25GHz – BLE-2440MHz
Frequency      Raw      Cable      AF        Level     Measurement      Pol      Height           Azt       Limit    Margin    Pass
   MHz         dBuV     Loss       dB       dBuV/m        Type         (V/H)      cm              Deg      dBuV/m     dB       /Fail

4879.772       41.33    4.18        -1       44.51      Peak Max          V          142          193        74      -29.49    Pass
6177.435       40.1     4.71      -0.33      44.48      Peak Max          V          218          270        74      -29.52    Pass
1773.355       41.75    2.59      -3.91      40.44      Peak Max          V          170          135        74      -33.56    Pass
4879.772       28.11    4.18        -1       31.29    Average Max         V          142          193        54      -22.71    Pass
6177.435       27.08    4.71      -0.33      31.45    Average Max         V          218          270        54      -22.55    Pass
1773.355       29.31    2.59      -3.91       28      Average Max         V          170          135        54       -26      Pass

Above 1GHz-25GHz – BLE –2480MHz
Frequency      Raw      Cable      AF        Level     Measurement      Pol      Height           Azt       Limit    Margin    Pass
   MHz         dBuV     Loss       dB       dBuV/m        Type         (V/H)      cm              Deg      dBuV/m     dB       /Fail

4959.385       40.34    4.25      -1.06      43.53      Peak Max          V          257          151        74      -30.47    Pass
9558.358       40.14    5.64       0.47      46.24      Peak Max          V          200              74     74      -27.76    Pass
4171.481       40.76    3.91      -0.78      43.9       Peak Max          V          187          196        74      -30.1     Pass
4959.385        27      4.25      -1.06      30.19    Average Max         V          257          151        54      -23.81    Pass
9558.358       27.36    5.64       0.47      33.47    Average Max         V          200              74     54      -20.53    Pass
4171.481       27.83    3.91      -0.78      30.96    Average Max         V          187          196        54      -23.04    Pass




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.   FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                               Page              15 of 18



Restricted Band Test plot (BLE)




                                              Restricted Band BLE 2402MHz




                                              Restricted Band BLE 2480MHz




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.       FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                              Page                  16 of 18




Annex A. TEST INSTRUMENT

          Instrument                     Model             Serial #             Cal Date       Cal Cycle    Cal Due     In use

      Radiated Emissions
  Keysight EXA 44GHz Spectrum
                                     N9030B(PXA)        MY57140374              09/06/2018      1 Year     09/06/2019
            Analyzer
  Bi-Log antenna (30MHz~2GHz)             JB1             A030702               03/09/2018      1 Year     03/09/2019
  Horn Antenna (1GHz~26GHz)               3115             100059               11/09/2018      1 Year     11/09/2019
  Horn Antenna (18GHz~40GHz)             PA-840            181251               06/23/2018      1 Year     06/23/2019
   Preamplifier (100KHz-7GHz)           LPA-6-30          11170602              05/09/2018      1 Year     05/09/2019
    Pre-Amplifier (1-26.5GHz)            8449B           3008A00715             08/16/2018      1 Year     08/16/2019




      775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.     FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                Page                17 of 18




Annex B. SIEMIC Accreditation

        Accreditations         Document                                        Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio Equipment: EN45011:
                                           EN ISO/IEC 17065
EU NB
                                           Electromagnetic Compatibility:
                                           EN45011 – EN ISO/IEC 17065

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
Hong Kong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.   FCC_IC_RF_SL18102402-ZBR-062_BLE_Rev3.0
                                                                 Page              18 of 18




                                            Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                            Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                            1 of the Radio Law

                                            EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                            KN22: Test Method for EMI
                                            EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                            KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                     Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                            RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                            80, RRL Notice 2004-68

                                            Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                            attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                            LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                            PLMN08

Taiwan BSMI CAB Recognition                 CNS 13438

                                            R-3083: Radiation 3 meter site
Japan VCCI                                  C-3421: Main Ports Conducted Interference Measurement
                                            T-1597: Telecommunication Ports Conducted Interference Measuremet

                                            EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                            61000.6.3, AS/NZS 61000.6.4

                                            Radiocommunications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                            AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                            AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                            Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                            AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                            AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                            AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                  S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                            S043.2




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2019-01-04 09:37:36
Document Modified: 2019-01-04 09:37:36

© 2024 FCC.report