Annex D_Part 15.407_UNII-2

FCC ID: HZB-NGP1058B

Test Report

Download: PDF
FCCID_3925254

            Annex E
A/C powerline Conducted Emission




              p17c0012_Annex D_FCC_Part 15.407_U-NII-2_Rev 1.0
                                                   Page 1 of 4


                               Conducted Emissions Test Results

                                       Line 1 Peak Plot
                                                                                    Points of Interest
                                    Compliance Testing                              Corrected Peak Data
                                  Conducted Emissions - Class A                     CISPRA_QP
                                        Line 1 (Neutral)                            CISPRA_AV
                    100.0

                     90.0

                     80.0
   Amplitude dBuV




                     70.0

                     60.0

                     50.0

                     40.0

                     30.0

                     20.0

                     10.0

                       0
                      150.0K            1.0M                                10.0M                   30.0M
                                                Frequency MHz
Operator: PS
EN55032 Class A_15 207.til                                         Job #:




                                       Line 2 Peak Plot
                                                                                    Points of Interest
                                    Compliance Testing                              Corrected Peak Data
                                  Conducted Emissions - Class A                     CISPRA_QP
                                         Line 2 (Phase)                             CISPRA_AV
                    100.0

                     90.0

                     80.0
   Amplitude dBuV




                     70.0

                     60.0

                     50.0

                     40.0

                     30.0

                     20.0

                     10.0

                       0
                      150.0K            1.0M                                10.0M                   30.0M
                                                Frequency MHz
Operator: PS
EN55032 Class A_15 207.til                                         Job #:




                                               p17c0012_Annex D_FCC_Part 15.407_U-NII-2_Rev 1.0
                                                                                    Page 2 of 4


                                 Line 1 Neutral Avg Detector


                          LISN                                  L1
              Measured               Cable                                        Avg
                          Corr                Attenuator       Final    Limit
 Frequency     Value                 Loss                                        Margin
                          Fact                                 Data
                                                                                  (dB)
                (dBuV)    (dB)        (dB)       (dB)         (dBuV)    (dBuV)
 17.972 MHz     42.923     0           0.2       10.3         53.423      60      -6.577
 18.478 MHz     44.063    0.1          0.2       10.3         54.663      60      -5.337
 18.734 MHz     39.467    0.1          0.2       10.3         50.067      60      -9.933
 19.243 MHz     39.437    0.1         0.21       10.3         50.047      60      -9.953
 20.507 MHz     38.64     0.1         0.22       10.3          49.26      60      -10.74
 21.775 MHz     38.053    0.1         0.22       10.3         48.673      60     -11.327

                           Line 2 Phase Avg Detector
   L2 Avg
                         LISN                               L2
              Measured              Cable                                         Avg
                         Corr                Attenuator    Final       Limit
 Frequency     Value                Loss                                         Margin
                         Fact                              Data
                                                                                  (dB)
               (dBuV)    (dB)        (dB)       (dB)       (dBuV)      (dBuV)
 18.48 MHz      43.1     0.1         0.2        10.3       53.703       60       -6.297
18.734 MHz     39.55     0.1         0.2        10.3       50.153       60       -9.847
19.243 MHz     38.93     0.1         0.21       10.3       49.537       60       -10.463
20.502 MHz     36.57     0.1         0.22       10.3       47.19        60       -12.81
21.774 MHz     38.23     0.1         0.22       10.3       48.853       60       -11.147
23.034 MHz      42.5     0.1         0.23       10.3       53.127       60       -6.873

                                 Line 1 Neutral QP Detector
L 1 QP
                          LISN                                  L1
              Measured               Cable                                         QP
                          Corr                Attenuator       Final    Limit
 Frequency     Value                 Loss                                        Margin
                          Fact                                 Data
                                                                                  (dB)
                (dBuV)    (dB)        (dB)       (dB)         (dBuV)    (dBuV)
 17.972 MHz     43.47      0           0.2       10.3          53.97      73      -19.03
 18.478 MHz     44.25     0.1          0.2       10.3          54.85      73      -18.15
 18.734 MHz     43.91     0.1          0.2       10.3          54.51      73      -18.49
 19.243 MHz     43.83     0.1         0.21       10.3          54.44      73      -18.56
 20.507 MHz     42.35     0.1         0.22       10.3          52.97      73      -20.03
 21.775 MHz     42.07     0.1         0.22       10.3          52.69      73      -20.31




                                       p17c0012_Annex D_FCC_Part 15.407_U-NII-2_Rev 1.0
                                                                            Page 3 of 4


                               Line 2 Phase QP Detector


                        LISN                               L2
             Measured             Cable                                       QP
                        Corr               Attenuator     Final    Limit
Frequency     Value               Loss                                      Margin
                        Fact                              Data
                                                                             (dB)
              (dBuV)    (dB)       (dB)       (dB)        (dBuV)   (dBuV)
18.48 MHz     43.07     0.1        0.2        10.3        53.67     73      -19.33
18.734 MHz    42.77     0.1        0.2        10.3        53.37     73      -19.63
19.243 MHz     43.6     0.1        0.21       10.3        54.21     73      -18.79
20.502 MHz    37.57     0.1        0.22       10.3        48.19     73      -24.81
21.774 MHz    41.83     0.1        0.22       10.3        52.45     73      -20.55
23.034 MHz    43.65     0.1        0.23       10.3        54.28     73      -18.72




                                    p17c0012_Annex D_FCC_Part 15.407_U-NII-2_Rev 1.0
                                                                         Page 4 of 4



Document Created: 2018-01-22 12:45:48
Document Modified: 2018-01-22 12:45:48

© 2024 FCC.report