User Manual

FCC ID: HZB-NGP1058B

Users Manual

Download: PDF
FCCID_3839600

                                                                                                            4. Next, wrap a layer of the butyl mastic tape over the adhesive side of the tape, covering all of the      1. Plug one end of the straight-through Cat5e cable into the Ethernet Port 1 of the device by
         What’s in the Kit                                        Image                                        tape and connector.                                                                                         following the Weatherproofing steps explained under section Weatherproofing RJ45
                                                                                                            5. Wrap vinyl tape over the butyl layer and cover the entire tape assembly.                                    Connections. Connect the other end of the cable into the Data & Power Out / PWR LAN-OUT
    Quick Installation Guide                                                                                                                                                                                               / OUT port on the PoE Injector.
                                                                                                            6. Place a small zip tie over the last wrap of tape to prevent it from unwrapping over time.
                                                                                                           For a detailed explanation of weatherproofing RJ45 connectors and RF connections, refer to                   2. Plugging in the second Cat5e cable to the Ethernet Port 2 is optional.
                                                                                                           Tsunami ® MP-10200 Series Hardware Installation Guide and Tsunami ® MP-10200 Series Antenna                    Notes:
                                                                                                           Installation Guide respectively, at http://support.proxim.com.                                                    • 56 V DC (8 W maximum) is available on the Ethernet Port 2; hence, ensure that
                                                                                                                                                                                                                                 connected device is rated to use the above voltage and maximum power.

Device Overview                                                                                           Assemble the Mounting Hardware                                                                                     • When PoE IN receives 56 V DC, PoE OUT delivers the same voltage, i.e., 56 V DC.
                                                                                                                                                                                                                             • By default, the Ethernet Port 2 is for Data only; however, it is possible to enable the PoE
                                                                                                            1. Fix the Mounting Plate (A) onto the bottom of the device using the provided screws and washers
                                                                                                                                                                                                                                 OUT and Data feature through Web configuration. Please make sure to disconnect the
                                                                                                               such that the antennas will be vertically and horizontally polarized when mounted; also, it is
                                                                                                                                                                                                                                 Ethernet Port 2 cable from the PC before enabling this feature.
                                                                                                               recommended to partially fasten the screws with washers into all the mounting holes, prior to
                                                                                                               final tightening of each screw. Torque the screws to 75 Lbf-in (86 Kgf-cm).                              3. To connect the device through a hub or a switch to a Personal Computer, connect an Ethernet
                                                                                                                                                                                                                           cable between the network interface card in the Personal Computer and the hub, and between
                                                                                                            2. Fix the Extension Arm (B) to the fixed Mounting Plate (A) with the provided screw, nut, and
                                                                                                                                                                                                                           the hub and the RJ45 Data In / LAN-IN / IN port on the PoE Injector.
                                                                                                               washers. The Extension Arm (B) gives the device more possible tilt, letting you adjust for azimuth
                                                                                                               or elevation over a larger angle.                                                                        4. To connect the device directly to a Personal Computer, connect an Ethernet cable between the
                                                                                                                                                                                                                           network interface card in the Personal Computer and the RJ45 Data In / LAN-IN / IN port on
                                                                                                            3. Fix the Mounting Bracket (C) to the fixed Extension Arm (B) with the provided screw, nut, and
                                                                                                                                                                                                                           the PoE Injector.
                                                                                                               washers. Partially tighten the joints J1 and J2 to allow for alignment of the device.
                                                                                                                                                                                                                        5. The PoE Power injector is a Gigabit Ethernet port and can supply up to 60 Watts.
                                                                                                            4. Once satisfied with the alignment, tighten the assembled parts by applying torque
                                                                                                               130 Lbf-in (150 Kgf-cm).
                                       Figure 1: MP-10250-BSX
                                                                                                            5. The last image in Figure 3 shows the fully assembled mounting hardware attached to the device.        Install Surge Protector
  The features of the device are as follows:
                                                                                                                                                                                                                       Tsunami® MP-10200 Series comes with a built-in Ethernet surge protection; however, it is mandatory
                                                                                                                                                                                                                       to install an approved lightning surge protector at the building ingress point. Moreover, if you are
                 Features                                        Description
                                                                                                                                                                                                                       installing the device in a region subjected to violent thunderstorms or severe weather conditions, then
   Ethernet Port 1                        •    PoE IN and Data                                                                                                                                                         installation of an additional approved lightning surge protector near the device is recommended.
                                          •    Debugging and Management                                                                                                                                                Note: To buy an additional Surge Protector (Part Number: 235-00001), place an order separately
   Ethernet Port 2                        •    Manageable PoE OUT and Data (Default Data only)                                                                                                                                with your distributor.

   Access Port                            •    Antenna Alignment                                                                                                                                                       Perform the following steps to ensure proper surge protection:
                                          •    12 V DC Power IN/OUT                                                                                                                                                      1. Mount a surge protector near the building ingress and use 10 AWG or larger wire to connect the
                                                                                                                                                                                                                            surge protector’s ground lug to earth ground.
   Grounding Points                       •    A provision to ground the device
                                                                                                                                                                                                                         2. The outdoor device and co-located surge protector should have a common grounding point
                                                                                                                                                                                                                            using the shortest possible grounding cable.
Weatherproofing RJ45 Connections                                                                                                                                                                                       Note: Use Outdoor-rated, UV protected, shielded CAT5e cable for the following.
  The following steps explain how to weatherproof the RJ45 connections:
                                                                                                                                                                                                                         3. Connect an RJ45 terminated cable between the indoor equipment and to the port on the surge
                                                                                                                                   Figure 3: Assemble the Mounting Hardware                                                 protector at the building ingress.
                                                                                                           Note: This figure is for illustration only. Device should be mounted in square position with                  4. Connect an RJ45 terminated cable between the surge protector and the outdoor device on
                                                                                                                 connectors facing downward.                                                                                Ethernet Port 1.


                                                                                                          Mount the Device
                                                                                                            1. To pole-mount the device, insert the provided bolts through Bracket (F), mate with Bracket (C)
                                                                                                               around the pole, and secure with supplied nuts and washers torquing to
                                                                                                               100 Lbf-in (115 Kgf-cm). The supplied screws (hex. Cap 5/16” x 80 mm long) are designed for
                                                                                                               pole diameters from 38 to 76 mm (1.5 to 3 inches).
                            Figure 2: Weatherproofing RJ45 Connections
   1. Use an outdoor rated CAT5e cable with a straight-through terminated on both ends.
   2. Slide the Flat Washer (A) onto the Connector Body (B) and screw the Connector Body (B) into the
      Ethernet port hole and torque to 10 Lbf-in (12 Kgf-cm).
   3. Next slide the Sealing Nut (E) and then the Compression Ring (D) over the cable end.
   4. Place and press the two piece Compression Washer Assembly (C) onto the cable in front of the
      Compression Ring (D) and Sealing Nut (E), then slide the Compression Ring (D) over the
      Compression Washer (C). Do not tighten the Sealing Nut (E) to the Connector Body (B).
   5. Connect the CAT5e cable by pushing the RJ45 connector through the Connector Body (B) and
      into the Radio Ethernet port. The RJ45 connector should lock into the port.
                                                                                                                                              Figure 4: Pole Mounting
   6. Next slide the Sealing Nut (E) over the Compression Washer Assembly (C) and slide the
      Compression Washer Assembly (C) until the Sealing Nut (E) can be screwed it onto on the fixed         2. To wall-mount the device, mount the bracket to a wall using 4 screws (not provided).                                                       Figure 6: Surge Protector
      end of the Connector Body (B). Torque the connection to 15 Lbf-in (17 Kgf-cm) making sure the
      Compression Washer (C) is tight to the cable and Connector Body (B) completely sealing the cable.                                                                                                                                                     IMPORTANT!
   7. Finally, ensure the plastic caps are tight on the secondary Ethernet Port 2 and Access Port and                                                                                                                  Ensure to loop the cable before entering the premise to prevent water ingress.
      torqued to 9 Lbf-in (10 Kgf-cm), if those ports are unused.

Additional Weatherproofing Steps                                                                                                                                                                                     Ground the Device
  To add an additional layer of protection to the connectors against the environment, do the following:
                                                                                                                                                                                                                       To ensure proper grounding, attach a ground wire of at least 12 AWG stranded to the device at either
   1. Wrap vinyl tape in a half-lapped fashion, from the weatherproof connector end and continue                                                                                                                       of the ground points which are located at the bottom corners of the device and use the grounding
      wrapping down 3 inches onto the CAT5e cable.                                                                                           Figure 5: Wall Mounting                                                   screw provided. It is important to follow the grounding guidelines below to protect the device against
   2. Wrap a second layer of vinyl tape in the reverse direction over the first layer of tape.                                                                                                                         lighting or ESD events:
   3. Now, wrap a third layer of vinyl tape over the other two layers but with the adhesive side up as    Plug in the Cables                                                                                            1. Connect one end of the grounding cable to the device and the other end to the closest earth
      this provides a sticky surface for the next layer.                                                   Note: Unscrew the sealing cap port cover for installation of cables.                                            ground point at the installation site.


                                WORP Driving the Internet of Things®                                                                     WORP Driving the Internet of Things®                                                                       WORP Driving the Internet of Things®
P/N 765-00321     Version 1.0                   2                   Copyrights © 2018 Proxim Wireless     P/N 765-00321    Version 1.0              3                       Copyright © 2018 Proxim Wireless         P/N 765-00321    Version 1.0              4                       Copyright © 2018 Proxim Wireless


                                                                                                                                                                                                                                            Tsunami® MP-10250-BSX
                                                                                                                                                                                                                                                       Quick Installation Guide

       2. Remove any extra ground wire length when finished connecting it to the single point earth
          ground.                                                                                                                                                                                                                                                IMPORTANT!
       3. Avoid sharp bends, loops or coiling the ground wire, always connect it straight to ground.                                                                                                                  For regulatory information and latest product updates, including the firmware and the
       4. A proper earth ground impedance is less than 1.0 ohm.                                                                                                                                                       MIBs, please visit Proxim’s support site at http://support.proxim.com.
       5. Measure ground impedance at the point where the surge protector ground wire is connected                                                                                                                    The device must be installed by a trained professional who is familiar with Radio
          and not at the grounding rod.                                                                                                                                                                               Frequency planning issues and the regulatory limits.
       6. Connect the surge protector ground wire and equipment ground (both power ground and                                                                                                                         The installation procedure is explained by taking connectorized device as an example.
          telecomm ground) to a single common ground.                                                                                                                                                                 Follow the same procedure for the integrated antenna device as well.
       7. Make sure all connections are fastened securely and tight.
       8. Never install a link during a storm and always follow your local safety codes.                                                         Figure 8: RSSI Light Pipe
.
                                                                                                                                                                                                                    Introduction
                                                                                                                                                                                                                      Proxim’s Tsunami® MP-10250 Base Station leverages the core abilities of the Tsunami 10000 series and
                                                                                                             Initialize the Device                                                                                    adds to them Proxim SmartConnect™ improvements: BeamX™(a Beam Forming Antenna system) and
                                                                                                               You can configure the IP address of the device by using HTTP, SNMP, PV Advanced (Proxim’s Network      Proxim SmartScan™ (a Scanning Radio). BeamX improves the average SNR by 6dB compared to a
                                                                                                               Management System), CLI or Proxim’s ScanTool. The default IP values used to access the device are      standard 60° sector, while the SmartScan Radio allows uninterrupted operation in the DFS bands.
                                                                                                               shown below:                                                                                           With the already high capacity and high power, the Tsunami® MP-10250-BSX is extremely robust in
                                                                                                                  •   IP address: 169.254.128.132                                                                     the face of interference, delivers more Mbps at a given point in the network and opens up additional
                                                                                                                  •   Subnet Mask: 255.255.255.0                                                                      5GHz spectrum.
                                                                                                                  •   Gateway: 169.254.128.132
                                                                                                                  •   Username: admin                                                                               Products Covered
                                                                                                                  •   Password: public
                                       Figure 7: Grounding the Device                                             •   SNMP Read Write Community String: public
                                                                                                                                                                                                                             Model                                           Description
    Power on the Device                                                                                      Download Software & Documentation                                                                        MP-10250-BSX               Outdoor Tsunami®  Base Station Unit with BeamX Antenna, SmartScan
                                                                                                                                                                                                                                                 Radio, 867 Mbps data rate and 2x2 MIMO radio operating in 5.150 -
      After connecting the PoE Injector and the device using straight-through CAT5e cable plug the power       To download the Software and Documentation, please visit Proxim’s support site                                                    5.850 GHz frequency band.
      cord into a power outlet. There is no ON/OFF switch on the device. To power down the unit, unplug        at http://support.proxim.com. Once you log on, select the product category Tsunami® MP-10200
      the RJ45 connector from the Data & Power Out / PWR LAN-OUT / OUT port on the PoE injector.               Series from Product Downloads Page and links to the latest software, SNMP MIB file and
                                                                                                               documentation will be available for download from the Tsunami® MP-10200 Series download and          Package Contents
    Port LED Indicators                                                                                        documentation page.                                                                                    Each shipment includes the items listed in the following table. Please verify that you have received all
      When the device is powered on, it performs                                                               Note: You need Acrobat Reader to view the PDF documents.                                               the parts in the shipment, prior to the installation.
      startup diagnostics. When startup is complete,
      the LEDs show the device’s operational state. The                                                      Warning                                                                                                          What’s in the Kit                                       Image
      LEDs are located on the Ethernet port inside the
                                                                                                               Modifications not expressly approved by the manufacturer could void the user authority to operate        MP-10250-BSX
      device enclosure.
                                                                                                               the equipment under FCC Rules.
       Note: The LEDs will not be visible when the                                                             Note: This equipment has been tested and found to comply with the limits for a Class A
             weather-sealing caps are installed.                                                                     digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
      The LEDs can be seen at the bottom of each                                                                     provide reasonable protection against harmful interference when the equipment is
      Ethernet port. The following table describes the                                                               operated in a commercial environment. This equipment generates, uses, and can
      status of LEDs:                                                                                                radiate radio frequency energy and, if not installed and used in accordance with the
                                                                                                                     instruction manual, may cause harmful interference to radio communications.                        Power Injector with Country
                                                                                                                     Operation of this equipment in a residential area is likely to cause harmful                       specific Power Cord
                                                                                                                     interference in which case the user will be required to correct the interference at his
        LED State                   Power/Ethernet LED*                          Wireless LED                        own expense.
                                                                                                                                                                                                                        WD - US and EU power cords
                                              Ethernet Port 1                                                                                                                                                           US - US power cord
                                                                                                             Technical Support
     Off                 No Power*                                      Radio is not present or failed to                                                                                                               Grounding Kit
                                                                                                                • Proxim Customer Support Website is available 7x24x365 at http://support.proxim.com
                                                                        detect
                                                                                                                • Telephone Support:
     Amber               Application Image is not detected*             Power is ON and the device
                                                                                                                        •   US and Canada: +1-408-383-7700; +1-866-674-6626
                                                                        detects reload signal
                                                                                                                        •   International: +1-408-383-7700
     Blinking Green      Power is ON, but the Ethernet link is          Radio is ON and the wireless link
                                                                                                                • Business Hours: 24x7 live response. Tier 3 support: 8 a.m. to 5 p.m. M-F PDT (UTC/GMT -7 hrs)         Connector Weather Proofing Kit
                         down*                                          is yet to be established
                                                                                                                                                                                                                        (2 sets)
     Solid Green         Power is ON and the Ethernet link is up*       Wireless link has been
                                                                        established

                                              Ethernet Port 2                                                                                                                                                           Mounting Kit and Hardware

     Off                 Application Image is not detected*             Not Applicable
     Amber               Not Applicable*                                Not Applicable
     Blinking Green      Power is ON, but the Ethernet link is          Not Applicable
                         down*
     Solid Green         Power is ON and the Ethernet link is up*       Not Applicable
     * The Power LED indication will start approximately about 10 seconds after powering up the device.
                                                                                                                                                                                                                        RSSI Light Pipe
                                                                                                                                                                                Proxim Wireless Corporation
    Align the Antenna                                                                                                                                                                  47633 Westinghouse Drive,
                                                                                                                                                                                   Fremont, California 94539, USA
      To assist alignment, the device can use the RSSI Light Pipe (supplied) to easily view the RSSI LEDs
                                                                                                                                                                                         Phone: +1 408-383-7600
      implemented in device’s Access Port.
                                                                                                                                                                                            Fax: +1 408-383-7680
                                                                                                                                                                                       http://www.proxim.com

                                    WORP Driving the Internet of Things®                                                                WORP Driving the Internet of Things®                                                                WORP Driving the Internet of Things®
    P/N 765-00321     Version 1.0              5                      Copyrights © 2018 Proxim Wireless     P/N 765-00321 Version 1.0                  6                     Copyright © 2018 Proxim Wireless       P/N 765-00321 Version 1.0               1                            Copyright © 2018 Proxim Wireless



Document Created: 2018-03-28 11:34:20
Document Modified: 2018-03-28 11:34:20