Annex E_Part 15.407_UNII-1

FCC ID: HZB-NGP1058B

Test Report

Download: PDF
FCCID_3839577

            Annex E
A/C powerline Conducted Emission




              p17c0012_Annex E_FCC_Part 15.407_U-NII-1_Rev 1.0
                                                   Page 1 of 4


                               Conducted Emissions Test Results

                                       Line 1 Peak Plot
                                                                                    Points of Interest
                                    Compliance Testing                              Corrected Peak Data
                                  Conducted Emissions - Class A                     CISPRA_QP
                                        Line 1 (Neutral)                            CISPRA_AV
                    100.0

                     90.0

                     80.0
   Amplitude dBuV




                     70.0

                     60.0

                     50.0

                     40.0

                     30.0

                     20.0

                     10.0

                       0
                      150.0K            1.0M                                10.0M                   30.0M
                                                Frequency MHz
Operator: PS
EN55032 Class A_15 207.til                                         Job #:




                                       Line 2 Peak Plot
                                                                                    Points of Interest
                                    Compliance Testing                              Corrected Peak Data
                                  Conducted Emissions - Class A                     CISPRA_QP
                                         Line 2 (Phase)                             CISPRA_AV
                    100.0

                     90.0

                     80.0
   Amplitude dBuV




                     70.0

                     60.0

                     50.0

                     40.0

                     30.0

                     20.0

                     10.0

                       0
                      150.0K            1.0M                                10.0M                   30.0M
                                                Frequency MHz
Operator: PS
EN55032 Class A_15 207.til                                         Job #:




                                               p17c0012_Annex E_FCC_Part 15.407_U-NII-1_Rev 1.0
                                                                                    Page 2 of 4


                                        Line 1 Neutral Avg Detector
                                   LISN
                                                 Cable                   L1 Final                Avg
              Measured Value     Correction                Attenuator                Limit
  Frequency                                       Loss                    Data                  Margin
                 (dBuV)           Factor                      (dB)                  (dBuV)
                                                  (dB)                   (dBuV)                  (dB)
                                    (dB)
 17.972 MHz       42.923              0            0.2         10.3      53.423       60         -6.577
 18.478 MHz       44.063             0.1           0.2         10.3      54.663       60         -5.337
 18.734 MHz       39.467             0.1           0.2         10.3      50.067       60         -9.933
 19.243 MHz       39.437             0.1          0.21         10.3      50.047       60         -9.953
 20.507 MHz       38.64              0.1          0.22         10.3      49.26        60         -10.74
 21.775 MHz       38.053             0.1          0.22         10.3      48.673       60        -11.327

                                    Line 2 Phase Avg Detector
              Measured     LISN Correction      Cable                   L2 Final                  Avg
                                                         Attenuator                  Limit
 Frequency      Value          Factor           Loss                      Data                  Margin
                                                            (dB)                    (dBuV)
               (dBuV)           (dB)             (dB)                   (dBuV)                    (dB)
 18.48 MHz       43.1            0.1              0.2       10.3         53.703       60         -6.297
 18.734 MHz     39.55            0.1              0.2       10.3         50.153       60         -9.847
 19.243 MHz     38.93            0.1             0.21       10.3         49.537       60        -10.463
 20.502 MHz     36.57            0.1             0.22       10.3         47.19        60         -12.81
 21.774 MHz     38.23            0.1             0.22        10.3        48.853       60        -11.147
 23.034 MHz      42.5            0.1             0.23        10.3        53.127       60         -6.873

                                       Line 1 Neutral QP Detector
              Measured     LISN Correction     Cable                    L1 Final                  QP
                                                         Attenuator                  Limit
Frequency       Value          Factor          Loss                      Data                   Margin
                                                            (dB)                    (dBuV)
               (dBuV)           (dB)            (dB)                    (dBuV)                   (dB)
17.972 MHz      43.47             0              0.2        10.3         53.97       73         -19.03
18.478 MHz     44.25             0.1             0.2        10.3         54.85       73         -18.15
18.734 MHz     43.91             0.1             0.2        10.3         54.51       73         -18.49
19.243 MHz     43.83             0.1            0.21        10.3         54.44       73         -18.56
20.507 MHz     42.35             0.1            0.22        10.3         52.97       73         -20.03
21.775 MHz     42.07             0.1            0.22        10.3         52.69       73         -20.31

                                        Line 2 Phase QP Detector
              Measured     LISN Correction      Cable                    L2 Final                   QP
                                                         Attenuator                    Limit
Frequency       Value          Factor           Loss                      Data                    Margin
                                                            (dB)                      (dBuV)
               (dBuV)           (dB)            (dB)                     (dBuV)                    (dB)
18.48 MHz      43.07             0.1             0.2         10.3          53.67           73      -19.33
18.734 MHz     42.77             0.1             0.2         10.3          53.37           73      -19.63
19.243 MHz      43.6             0.1            0.21         10.3          54.21           73      -18.79
20.502 MHz     37.57             0.1            0.22         10.3          48.19           73      -24.81
21.774 MHz     41.83             0.1            0.22         10.3          52.45           73      -20.55
23.034 MHz     43.65             0.1            0.23         10.3          54.28           73      -18.72




                                              p17c0012_Annex E_FCC_Part 15.407_U-NII-1_Rev 1.0
                                                                                   Page 3 of 4



Document Created: 2018-01-19 16:19:38
Document Modified: 2018-01-19 16:19:38

© 2024 FCC.report