FCC Report

FCC ID: HYQ1EA

Test Report

Download: PDF
FCCID_1922549

                                                                                       Test report No.   :   10005487H—B—R1
                                                                                       Page              :   1 of 25
                                                                                       Issued date       :   March 15, 2013
                                                                                       Revised date      :   March 21, 2013
                                                                                       FCC ID            :   HYQIEA




                                  RADIO TEST REPORT
                                  Test Report No. : 10005487H—B—R1

       Applicant                               $     DENSO CORPORATION

       Type of Equipment                       f     Electronic Key

       Model No.                               $     1EA

       Test regulation                         $     FCC Part 15 Subpart C: 2012

       FCC ID                                  $     HYQIEA

       Test Result                             s     Complied

                     This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
          in p o p




                     The results in this report apply only to the sample tested.
                     This sample tested is in compliance with above regulation.
                     The test results in this report are traceable to the national or international standards.
                     This test report must not be used by the customer to claim product certification, approval, or endorsement
                     by NVLAP, NIST, or any agency of the Federal Government.
           6.        This report is a revised version of 10005487H—B. 10005487H—B is replaced with this report.


                             Date of test:                      March 9 and 10, 2013



                                                               %V/jé/tg
                             Representative test
                             engineer:
                                                                   Katsunori Okai
                                                               Engineer of WiSE Japan,
                                                               UL Verification Service


                             Approved by:                %                                    *
                                                                 MasanorW
                                                               Manager of     WiSE Japan,
                                                               UL Verification Service



                                                               This laboratory is accredited by the NVLAP LAB CODE
                                                   ®           200572—0, U.S.A. The tests reported herein have been
                                                               performed in accordance with its terms of accreditation.
                                                               *As for the range of Accreditation in NVLAP, you may
          Nv                         Z&@                       refer to the WEB address,
                                                               http://www.ul.com/japan/jpn/pages/services/eme/about/ma
                                                               rk1/index.jsp#nvlap
          NVLAP LAB CODE: 200572—0




UL Japan, Inc.
Head Office EMC Lab.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN
Telephone        : +81 596 24 8116
Facsimile        : +81 596 24 8124
                                                                                                                13—EM—FO429


                                                                      Test report No.   : 10005487H-B-R1
                                                                      Page              : 2 of 25
                                                                      Issued date       : March 15, 2013
                                                                      Revised date      : March 21, 2013
                                                                      FCC ID            : HYQ1EA




                                  REVISION HISTORY
                               Original Test Report No.: 10005487H-B

Revision     Test report No.         Date             Page      Contents
                                                      revised
-            10005487H-B             March 15, 2013   -         -
(Original)
1            10005487H-B-R1          March 21, 2013   P,19      Correction of Modulation




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                                          Test report No.         : 10005487H-B-R1
                                                                                                          Page                    : 3 of 25
                                                                                                          Issued date             : March 15, 2013
                                                                                                          Revised date            : March 21, 2013
                                                                                                          FCC ID                  : HYQ1EA



CONTENTS                                                                                                                                      PAGE

SECTION 1: Customer information ·············································································· 4
SECTION 2: Equipment under test (E.U.T.) ···································································· 4
SECTION 3: Test specification, procedures & results························································· 5
SECTION 4: Operation of E.U.T. during testing ······························································· 8
SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission) 9
SECTION 6: Automatically deactivate ········································································· 10
SECTION 7: -20dB and 99% Occupied Bandwidth ························································· 10
APPENDIX 1: Data of EMI test ·················································································· 11
    Automatically deactivate................................................................................................................... 11
    Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 13
    -20dB and 99% Occupied Bandwidth ............................................................................................... 15
    Duty Cycle ........................................................................................................................................ 17
APPENDIX 2:Test Instruments ··················································································· 22
APPENDIX 3: Photographs of test setup ······································································· 23
    Radiated emission ............................................................................................................................. 23
    Worst case position ........................................................................................................................... 24




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                Test report No.   : 10005487H-B-R1
                                                                                Page              : 4 of 25
                                                                                Issued date       : March 15, 2013
                                                                                Revised date      : March 21, 2013
                                                                                FCC ID            : HYQ1EA



SECTION 1: Customer information
Company Name                           :     DENSO CORPORATION
Address                                :     1-1 Showa-cho, Kariya-shi, Aichi-ken, 448-8661 Japan
Telephone Number                       :     +81-566-61-7076
Facsimile Number                       :     +81-566-25-4792
Contact Person                         :     TAKAHIDE KITAHARA



SECTION 2: Equipment under test (E.U.T.)
2.1     Identification of E.U.T.

Type of Equipment                      :     Electronic Key
Model No.                              :     1EA
Serial No.                             :     Refer to Clause 4.2
Rating                                 :     DC 3.0V
Receipt Date of Sample                 :     February 23, 2013
Country of Mass-production             :     Japan, United States of America, China
Condition of EUT                       :     Engineering prototype
                                             (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                    :     No Modification by the test lab


2.2     Product Description

Model No: 1EA (referred to as the EUT in this report) is the Electronic Key.
The EUT (1EA) transmits radio wave signals of FSK and ASK.
The radio wave signals of FSK and ASK are not transmitted simultaneously.
Either one of FSK and ASK is transmitted by operator's action.
End users cannot control which of FSK and ASK to be transmitted.

General Specification
Clock frequency(ies) in the system     :     16 MHz RC oscillator (IC clock)
                                             13.08 MHz Crystal (RF)

Radio Specification
Radio Type                             :     Transceiver
Frequency of Operation                 :     433.92MHz
Modulation                             :     FSK (F1D) / ASK (A1D)
Power Supply (radio part input)        :     DC 3.0V
Type of Battery                        :     One lithium battery
Antenna type                           :     Built-in type (Fixed)




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                           Test report No.        : 10005487H-B-R1
                                                                                           Page                   : 5 of 25
                                                                                           Issued date            : March 15, 2013
                                                                                           Revised date           : March 21, 2013
                                                                                           FCC ID                 : HYQ1EA



 SECTION 3: Test specification, procedures & results

 3.1      Test Specification

 Test Specification          :     Test specification: FCC Part 15 Subpart C: 2012, final revised on December 27, 2012
                                   and effective January 28, 2013

 Title                       :     FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                   Section 15.231 Periodic operation in the band 40.66 - 40.70MHz
                                   and above 70MHz


 3.2      Procedures and results

Item                        Test Procedure              Specification               Worst margin             Results     Remarks
                            FCC: ANSI C63.4:2003        FCC: Section 15.207
                            7. AC powerline conducted
                            emission measurements
Conducted emission                                                                  N/A                      N/A*1)      -
                            IC: RSS-Gen 7.2.4           IC: RSS-Gen 7.2.4


                            FCC: ANSI C63.4:2003        FCC: Section 15.231(a)(1)
                            13. Measurement of
Automatically Deactivate    intentional radiators                                   N/A                      Complied    Radiated
                            IC: -                       IC: RSS-210 A1.1.1

                            FCC: ANSI C63.4:2003        FCC: Section 15.231(b)      [FSK]
                            13. Measurement of                                      10.1dB
                            intentional radiators                                   433.920MHz
                            IC: RSS-Gen 4.8             IC: RSS-210 A1.1.2          Horizontal
Electric Field Strength                                                             PK with Duty factor
                                                                                                             Complied    Radiated
of Fundamental Emission                                                             [ASK]
                                                                                    6.1dB
                                                                                    433.920MHz
                                                                                    Horizontal
                                                                                    PK with Duty factor
                            FCC: ANSI C63.4:2003        FCC: Section 15.205         [FSK]
                            13. Measurement of                Section 15.209        8.3dB
                            intentional radiators             Section 15.231(b)     3037.440MHz
                            IC: RSS-Gen 4.9             IC: RSS-210 A1.1.2, 2.5.1   Horizontal
Electric Field Strength                                     RSS-Gen 7.2.5           PK with Duty factor
                                                                                                             Complied    Radiated
of Spurious Emission                                                                [ASK]
                                                                                    7.8dB
                                                                                    3037.440MHz
                                                                                    Vertical
                                                                                    PK with Duty factor
                            FCC: ANSI C63.4:2003        FCC: Section 15.231(c)
                            13. Measurement of
                            intentional radiators
-20dB Bandwidth             KDB 926416                                              N/A                      Complied    Radiated
                            IC: -                       IC: Reference data

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT does not have AC Mains.




 UL Japan, Inc.
 Head Office EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone       : +81 596 24 8116
 Facsimile       : +81 596 24 8124


                                                                                         Test report No.       : 10005487H-B-R1
                                                                                         Page                  : 6 of 25
                                                                                         Issued date           : March 15, 2013
                                                                                         Revised date          : March 21, 2013
                                                                                         FCC ID                : HYQ1EA



FCC 15.31 (e)
This test was performed with the New Battery (DC 3.0V) and the constant voltage was supplied to the EUT during the
tests. Therefore, the EUT complies with the requirement.

FCC Part 15.203 Antenna requirement
It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
equipment complies with the antenna requirement of Section 15.203.


3.3       Addition to standard

Item                        Test Procedure       Specification            Worst margin      Results        Remarks
99% Occupied
                            IC: RSS-Gen 4.6.1    IC: RSS-Gen 4.6.1        N/A               Complied       Radiated
Bandwidth
Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4      Uncertainty

EMI
The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2.

      Test room                                              Radiated emission
      (semi-                       (3m*)(+dB)                                    (1m*)(+dB)            (0.5m*)(+dB)
      anechoic      9kHz       30MHz      300MHz                  1GHz       10GHz       18GHz            26.5GHz
      chamber)    -30MHz      -300MHz -1GHz                      -10GHz     -18GHz      -26.5GHz          -40GHz
   No.1            4.3dB        5.0dB      5.1dB                  4.9dB      5.8dB        4.4dB            4.3dB
   No.2            4.3dB        5.2dB      5.1dB                  5.0dB      5.7dB        4.3dB            4.2dB
   No.3            4.6dB        5.0dB      5.1dB                  5.0dB      5.7dB        4.5dB            4.2dB
   No.4            4.8dB        5.2dB      5.0dB                  5.0dB      5.7dB        5.2dB            4.2dB
*3m/1m/0.5m = Measurement distance


Radiated emission test(3m)
[FSK]
The data listed in this test report has enough margin, more than the site margin.
[ASK]
The data listed in this test report has enough margin, more than the site margin.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                    Test report No.    : 10005487H-B-R1
                                                                                    Page               : 7 of 25
                                                                                    Issued date        : March 15, 2013
                                                                                    Revised date       : March 21, 2013
                                                                                    FCC ID             : HYQ1EA



3.5      Test Location

UL Japan, Inc. Head Office EMC Lab. *NVLAP Lab. Code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8116          Facsimile : +81 596 24 8124
                        FCC           IC Registration    Width x Depth x      Size of                        Other
                        Registration Number              Height (m)           reference ground plane (m) /   rooms
                        Number                                                horizontal conducting plane
 No.1 semi-anechoic     313583        2973C-1            19.2 x 11.2 x 7.7m   7.0 x 6.0m                     No.1 Power
 chamber                                                                                                     source room
 No.2 semi-anechoic     655103        2973C-2            7.5 x 5.8 x 5.2m     4.0 x 4.0m                     -
 chamber
 No.3 semi-anechoic     148738        2973C-3            12.0 x 8.5 x 5.9m    6.8 x 5.75m                    No.3
 chamber                                                                                                     Preparation
                                                                                                             room
 No.3 shielded room    -              -                  4.0 x 6.0 x 2.7m     N/A                            -
 No.4 semi-anechoic    134570         2973C-4            12.0 x 8.5 x 5.9m    6.8 x 5.75m                    No.4
 chamber                                                                                                     Preparation
                                                                                                             room
 No.4 shielded room    -              -                  4.0 x 6.0 x 2.7m     N/A                            -
 No.5 semi-anechoic    -              -                                                                      -
                                                         6.0 x 6.0 x 3.9m     6.0 x 6.0m
 chamber
 No.6 shielded         -              -                  4.0 x 4.5 x 2.7m     4.75 x 5.4 m                   -
 room
 No.6 measurement      -              -                  4.75 x 5.4 x 3.0m    4.75 x 4.15 m                  -
 room
 No.7 shielded room    -              -                  4.7 x 7.5 x 2.7m     4.7 x 7.5m                     -
 No.8 measurement       -              -               3.1 x 5.0 x 2.7m      N/A                             -
 room
 No.9 measurement       -              -               8.0 x 4.5 x 2.8m      2.0 x 2.0m                      -
 room
 No.10 measurement      -              -               2.6 x 2.8 x 2.5m      2.4 x 2.4m                      -
 room
 No.11 measurement      -              -               3.1 x 3.4 x 3.0m      2.4 x 3.4m                      -
 room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0m for No.1, No.2, No.3, and     No.4 semi-anechoic
chambers and No.3 and No.4 shielded rooms.


3.6    Test set up, Data of EMI, Test instruments.

Refer to APPENDIX.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                              Test report No.     : 10005487H-B-R1
                                                                              Page                : 8 of 25
                                                                              Issued date         : March 15, 2013
                                                                              Revised date        : March 21, 2013
                                                                              FCC ID              : HYQ1EA



SECTION 4: Operation of E.U.T. during testing

4.1     Operating Modes

Test Item*                                             Mode
Automatically Deactivate                               Transmitting mode, FSK/ASK, 433.92MHz
Duty Cycle
Electric Field Strength of Fundamental Emission        Transmitting mode, FSK/ASK, 433.92MHz *1)
Electric Field Strength of Spurious Emission
-20dB & 99% Occupied Bandwidth
* The system was configured in typical fashion (as a customer would normally use it) for testing.
*1) The software of this mode is the same as one of normal product, except that EUT continues to transmit when
transceiver button is being pressed (For Normal use mode, EUT stops when transceiver button is being pressed.)
End users cannot change the settings of the output power of the product.


4.2 Configuration and peripherals


                                                          A:EUT




                                    * Test data was taken under worse case conditions.

Description of EUT
 No. Item                         Model number        Serial number Manufacturer                Remarks
 A    Electronic Key              1EA                 001           DENSO                       EUT
                                                                    CORPORATION




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                Test report No.    : 10005487H-B-R1
                                                                                Page               : 9 of 25
                                                                                Issued date        : March 15, 2013
                                                                                Revised date       : March 21, 2013
                                                                                FCC ID             : HYQ1EA


SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious
Emission)
Test Procedure and conditions

EUT was placed on a urethane platform of nominal size, 0.5m by 1.0m, raised 0.8m above the conducting ground plane.
The EUT was set on the center of the tabletop.
Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement
antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.
Photographs of the set up are shown in Appendix 1.

[Transmitting mode]

(Below 30MHz)
The noise level was checked by moving a search-coil (Loop Antenna) close to the EUT.

(Above 30MHz)
The Radiated Electric Field Strength has been measured on Semi anechoic chamber with a ground plane and at a distance
of 3m.
The measuring antenna height was varied between 1 and 4m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver/spectrum
analyzer.
- The carrier level (or, noise levels) was (or were) measured at each position of all three axes X, Y and Z, and the
position that has the maximum noise was determined. Noise levels of all the frequencies were measured at the position.

*The result is rounded off to the second decimal place, so some differences might be observed.

Test Antennas are used as below;
   Frequency          Below 30MHz              30MHz to 300MHz         300MHz to 1GHz             Above 1GHz
   Antenna Type       Loop                     Biconical               Logperiodic                Horn

                    From 9kHz       From 90kHz          From           From           From        Above 1GHz
                   to 90kHz and      to 110kHz        150kHz         490kHz          30MHz
                   From 110kHz                       to 490kHz      to 30MHz        to 1GHz
                     to 150kHz
   Detector             Peak            Peak           Peak           Peak         Peak and        Peak and Peak with
   Type                                                                           Peak with           Duty factor
                                                                                  Duty factor
   IF                  200Hz           200Hz          9.1kHz         9.1kHz        120kHz         PK: S/A:RBW 1MHz,
   Bandwidth                                                                                              VBW 3MHz

- The carrier level was measured at each position of all three axes X, Y and Z, and the position that has the maximum
noise was determined.
Noise levels of all the frequencies were measured at the position.

This EUT has two modes which mechanical key is inserted or not. The worst case was confirmed with and without
mechanical key, as a result, the test with mechanical key was the worst case. Therefore the test with mechanical key was
performed only.

*The result is rounded off to the second decimal place, so some differences might be observed.

Measurement range                  : 9kHz-4.4GHz
Test data                          : APPENDIX
Test result                        : Pass


UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                              Test report No.   : 10005487H-B-R1
                                                                                              Page              : 10 of 25
                                                                                              Issued date       : March 15, 2013
                                                                                              Revised date      : March 21, 2013
                                                                                              FCC ID            : HYQ1EA


SECTION 6: Automatically deactivate

Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data                                 : APPENDIX
Test result                               : Pass



SECTION 7: -20dB and 99% Occupied Bandwidth
Test Procedure

The measurement was performed in the antenna height to gain the maximum of Electric field strength.

Test              Span                      RBW           VBW            Sweep                Detector Trace         Instrument used
20dB Bandwidth 300kHz                       3kHz          9.1kHz         Auto                 Peak       Max Hold    Spectrum Analyzer
99% Occupied   Enough width to display      1 % of Span   Three times    Auto                 Peak *1)   Max Hold    Spectrum Analyzer
Bandwidth      20dB Bandwidth                             of RBW                                         *1)

*1) The measurement was performed with Peak detector, Max Hold since the duty cycle was not 100%.

Test data                                 : APPENDIX
Test result                               : Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                               Test report No.   : 10005487H-B-R1
                                                                               Page              : 11 of 25
                                                                               Issued date       : March 15, 2013
                                                                               Revised date      : March 21, 2013
                                                                               FCC ID            : HYQ1EA


APPENDIX 1: Data of EMI test

                                          Automatically deactivate

                Test place                No.2 Semi Anechoic Chamber
                Report No.                10005487H
                Date                      03/09/2013
                Temperature/ Humidity     24 deg. C / 33% RH
                Engineer                  Motoya Imura
                Mode                      Transmitting mode, FSK (433.92MHz)

                             Time of                     Limit                      Result
                           Transmitting
                              [sec]                      [sec]
                              0.250                      5.00                        Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                               Test report No.   : 10005487H-B-R1
                                                                               Page              : 12 of 25
                                                                               Issued date       : March 15, 2013
                                                                               Revised date      : March 21, 2013
                                                                               FCC ID            : HYQ1EA


                                          Automatically deactivate

                Test place                No.2 Semi Anechoic Chamber
                Report No.                10005487H
                Date                      03/09/2013
                Temperature/ Humidity     24 deg. C / 33% RH
                Engineer                  Motoya Imura
                Mode                      Transmitting mode, ASK (433.92MHz)

                             Time of                     Limit                      Result
                           Transmitting
                              [sec]                      [sec]
                              0.250                      5.00                        Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                                                   Test report No.              : 10005487H-B-R1
                                                                                                                   Page                         : 13 of 25
                                                                                                                   Issued date                  : March 15, 2013
                                                                                                                   Revised date                 : March 21, 2013
                                                                                                                   FCC ID                       : HYQ1EA


        Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
              Test place                              Head Office EMC Lab. No.2 Semi Anechoic Chamber
              Report No.                              10005487H
              Date                                    03/09/2013           /  03/10/2013
              Temperature/ Humidity                   24 deg. C / 33% RH /    23 deg. C / 30% RH
              Engineer                                Motoya Imura       /    Katsunori Okai
              Mode                                    Transmitting mode, FSK (433.92MHz)
       PK
        Frequency    Detector        Reading         Ant      Loss       Gain     Duty           Result       Limit            Margin                   Remark
                                     [dBuV]         Factor                       Factor        [dBuV/m]                         [dB]               Inside or Outside
         [MHz]                    Hor        Ver   [dB/m]     [dB]       [dB]     [dB]        Hor       Ver [dBuV/m]        Hor      Ver         of Restricted Bands
          433.920 PK               81.3       81.1     17.6       9.5      28.5         -      79.9      79.7  100.8         20.9     21.1     Carrier
          867.840 PK               31.7       33.1     22.2     11.2       27.9         -      37.2      38.6   80.8         43.6     42.2     Outside
        1301.760 PK                48.5       48.7     24.8       1.7      36.3         -      38.7      38.9   73.9         35.2     35.0     Inside
        1735.680 PK                56.0       57.3     26.0       2.0      35.9         -      48.1      49.4   80.8         32.7     31.4     Outside
        2169.600 PK                47.3       46.0     26.9       2.2      35.7         -      40.7      39.4   80.8         40.1     41.4     Outside
        2603.520 PK                58.7       57.0     26.9       2.5      35.6         -      52.5      50.8   80.8         28.3     30.0     Outside
        3037.440 PK                66.6       65.4     27.6       2.7      35.2         -      61.7      60.5   80.8         19.1     20.3     Outside
        3471.360 PK                48.6       48.7     28.1       2.9      34.9         -      44.7      44.8   80.8         36.1     36.0     Outside
        3905.280 PK                44.4       44.1     28.9       3.1      34.6         -      41.8      41.5   73.9         32.1     32.4     Inside
        4339.200 PK                42.4       42.5     29.5       3.3      34.7         -      40.5      40.6   73.9         33.4     33.3     Inside
       Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier)



       PK with Duty factor
        Frequency Detector           Reading         Ant      Loss       Gain     Duty           Result          Limit          Margin                   Remark
                                      [dBuV]        Factor                       Factor        [dBuV/m]                          [dB]
         [MHz]                    Hor        Ver   [dB/m]     [dB]       [dB]     [dB]       Hor        Ver [dBuV/m] Hor               Ver
          433.920 PK                81.3      81.1     17.6       9.5      28.5      -9.2     70.7       70.5      80.8       10.1      10.3   Carrier
          867.840 PK                31.7      33.1     22.2     11.2       27.9      -9.2     28.0       29.4      60.8       32.8      31.4   Outside
        1301.760 PK                 48.5      48.7     24.8       1.7      36.3      -9.2     29.5       29.7      53.9       24.4      24.2   Inside
        1735.680 PK                 56.0      57.3     26.0       2.0      35.9      -9.2     38.9       40.2      60.8       21.9      20.6   Outside
        2169.600 PK                 47.3      46.0     26.9       2.2      35.7      -9.2     31.5       30.2      60.8       29.3      30.6   Outside
        2603.520 PK                 58.7      57.0     26.9       2.5      35.6      -9.2     43.3       41.6      60.8       17.5      19.2   Outside
        3037.440 PK                 66.6      65.4     27.6       2.7      35.2      -9.2     52.5       51.3      60.8        8.3       9.5   Outside
        3471.360 PK                 48.6      48.7     28.1       2.9      34.9      -9.2     35.5       35.6      60.8       25.3      25.2   Outside
        3905.280 PK                 44.4      44.1     28.9       3.1      34.6      -9.2     32.6       32.3      53.9       21.3      21.6   Inside
        4339.200 PK                 42.4      42.5     29.5       3.3      34.7      -9.2     31.3       31.4      53.9       22.6      22.5   Inside
       Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier) + Duty factor (Refer to Duty factor data sheet)

       *Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                                                   Test report No.              : 10005487H-B-R1
                                                                                                                   Page                         : 14 of 25
                                                                                                                   Issued date                  : March 15, 2013
                                                                                                                   Revised date                 : March 21, 2013
                                                                                                                   FCC ID                       : HYQ1EA


      Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
              Test place                              Head Office EMC Lab. No.2 Semi Anechoic Chamber
              Report No.                              10005487H
              Date                                    03/09/2013           /  03/10/2013
              Temperature/ Humidity                   24 deg. C / 33% RH /    23 deg. C / 30% RH
              Engineer                                Motoya Imura       /    Katsunori Okai
              Mode                                    Transmitting mode, ASK (433.92MHz)
       PK
        Frequency    Detector        Reading         Ant      Loss       Gain     Duty           Result      Limit             Margin                   Remark
                                     [dBuV]         Factor                       Factor        [dBuV/m]                         [dB]               Inside or Outside
         [MHz]                    Hor        Ver   [dB/m]     [dB]       [dB]     [dB]        Hor      Ver [dBuV/m]         Hor      Ver         of Restricted Bands
          433.920 PK               91.1       90.8     17.6       9.5      28.5         -      89.7     89.4  100.8          11.1     11.4     Carrier
          867.840 PK               39.7       40.1     22.2     11.2       27.9         -      45.2     45.6   80.8          35.6     35.2     Outside
        1301.760 PK                54.1       56.7     24.8       1.7      36.3         -      44.3     46.9   73.9          29.6     27.0     Inside
        1735.680 PK                57.5       62.0     26.0       2.0      35.9         -      49.6     54.1   80.8          31.2     26.7     Outside
        2169.600 PK                60.8       60.0     26.9       2.2      35.7         -      54.2     53.4   80.8          26.6     27.4     Outside
        2603.520 PK                64.9       63.7     26.9       2.5      35.6         -      58.7     57.5   80.8          22.1     23.3     Outside
        3037.440 PK                72.6       72.9     27.6       2.7      35.2         -      67.7     68.0   80.8          13.1     12.8     Outside
        3471.360 PK                55.2       55.2     28.1       2.9      34.9         -      51.3     51.3   80.8          29.5     29.5     Outside
        3905.280 PK                51.1       52.3     28.9       3.1      34.6         -      48.5     49.7   73.9          25.4     24.2     Inside
        4339.200 PK                42.5       43.9     29.5       3.3      34.7         -      40.6     42.0   73.9          33.3     31.9     Inside
       Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier)



       PK with Duty factor
        Frequency Detector           Reading         Ant      Loss       Gain     Duty           Result          Limit          Margin                   Remark
                                     [dBuV]         Factor                       Factor        [dBuV/m]                          [dB]
         [MHz]                    Hor        Ver   [dB/m]     [dB]       [dB]     [dB]       Hor        Ver [dBuV/m] Hor               Ver
          433.920 PK               91.1       90.8     17.6       9.5      28.5    -15.0      74.7       74.4      80.8        6.1       6.4   Carrier
          867.840 PK               39.7       40.1     22.2     11.2       27.9    -15.0      30.2       30.6      60.8       30.6      30.2   Outside
        1301.760 PK                54.1       56.7     24.8       1.7      36.3    -15.0      29.3       31.9      53.9       24.6      22.0   Inside
        1735.680 PK                57.5       62.0     26.0       2.0      35.9    -15.0      34.6       39.1      60.8       26.2      21.7   Outside
        2169.600 PK                60.8       60.0     26.9       2.2      35.7    -15.0      39.2       38.4      60.8       21.6      22.4   Outside
        2603.520 PK                64.9       63.7     26.9       2.5      35.6    -15.0      43.7       42.5      60.8       17.1      18.3   Outside
        3037.440 PK                72.6       72.9     27.6       2.7      35.2    -15.0      52.7       53.0      60.8        8.1       7.8   Outside
        3471.360 PK                55.2       55.2     28.1       2.9      34.9    -15.0      36.3       36.3      60.8       24.5      24.5   Outside
        3905.280 PK                51.1       52.3     28.9       3.1      34.6    -15.0      33.5       34.7      53.9       20.4      19.2   Inside
        4339.200 PK                42.5       43.9     29.5       3.3      34.7    -15.0      25.6       27.0      53.9       28.3      26.9   Inside
       Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier) + Duty factor (Refer to Duty factor data sheet)

       *Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                               Test report No.   : 10005487H-B-R1
                                                                               Page              : 15 of 25
                                                                               Issued date       : March 15, 2013
                                                                               Revised date      : March 21, 2013
                                                                               FCC ID            : HYQ1EA




                                    -20dB and 99% Occupied Bandwidth
            Test place               Head Office EMC Lab. No.2 Semi Anechoic Chamber
            Report No.               10005487H
            Date                     03/09/2013
            Temperature/ Humidity    24 deg. C / 33% RH
            Engineer                 Motoya Imura
            Mode                     Transmitting mode, FSK / ASK (433.92MHz)


                 Bandwidth Limit : Fundamental Frequency    433.92 MHz x 0.25% =       1084.80 kHz
                FSK
                     -20dB Bandwidth            Bandwidth Limit       Result
                          [kHz]                      [kHz]
                          85.203                    1084.80             Pass

                ASK
                      -20dB Bandwidth          Bandwidth Limit         Result
                           [kHz]                   [kHz]
                           28.424                 1084.80               Pass




                Bandwidth Limit : Fundamental Frequency    433.92 MHz x 0.25% = 1084.80 kHz
               FSK
                 99% Occupied Bandwidth        Bandwidth Limit       Result
                         [kHz]                      [kHz]
                         84.55                     1084.80            Pass

               ASK
                99% Occupied Bandwidth         Bandwidth Limit         Result
                        [kHz]                      [kHz]
                       98.64                      1084.80               Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                Test report No.   : 10005487H-B-R1
                                                                Page              : 16 of 25
                                                                Issued date       : March 15, 2013
                                                                Revised date      : March 21, 2013
                                                                FCC ID            : HYQ1EA




                                   -20dB and 99% Occupied Bandwidth

                                                      FSK




                                                      ASK




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                     Test report No.      : 10005487H-B-R1
                                                                                     Page                 : 17 of 25
                                                                                     Issued date          : March 15, 2013
                                                                                     Revised date         : March 21, 2013
                                                                                     FCC ID               : HYQ1EA



                                                          Duty Cycle
            Test place                     Head Office EMC Lab. No.2 Semi Anechoic Chamber
            Report No.                     10005487H
            Date                           03/10/2013
            Temperature/ Humidity          21 deg. C / 30% RH
            Engineer                       Katsunori Okai
            Mode                           Transmitting mode, FSK (433.92MHz)

          (Total)
             ON time         Cycle                Duty               Duty
               [ms]           [ms]          (On time/Cycle)          [dB]
             34.620         100.00              0.3462              -9.21
          Duty = 20log10 (ON time/100ms)




                                                              A




                                                                            *A is intentional off time.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                   Test report No.   : 10005487H-B-R1
                                                                   Page              : 18 of 25
                                                                   Issued date       : March 15, 2013
                                                                   Revised date      : March 21, 2013
                                                                   FCC ID            : HYQ1EA



                                                      Duty Cycle


                                                       500mS




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                           Test report No.      : 10005487H-B-R1
                                                                                           Page                 : 19 of 25
                                                                                           Issued date          : March 15, 2013
                                                                                           Revised date         : March 21, 2013
                                                                                           FCC ID               : HYQ1EA




                                                             Duty Cycle
            Test place                     Head Office EMC Lab. No.2 Semi Anechoic Chamber
            Report No.                     10005487H
            Date                           03/10/2013
            Temperature/ Humidity          21 deg. C / 30% RH
            Engineer                       Katsunori Okai
            Mode                           Transmitting mode, ASK (433.92MHz)


                                        ON time(One pulse)      ON time(in 100ms)
           Type           Times               [ms]                    [ms]
             A              52                0.125                   6.500
             B              46                0.243                   11.192
       *1)ON time(in 100ms) = Times * ON time(One pulse)
       *2)The train of pulses was exceeding 100msec, and that sampled 100msec was the worst case against the pulse train.

       (Total)
          ON time          Cycle              Duty                 Duty
            [ms]           [ms]         (On time/Cycle)             [dB]
          17.692          100.00            0.1769                -15.04
       *3)ON time = Type A's ON time (in 100ms) + Type B's ON time (in 100ms)
       *4)Duty = 20log10 (ON time/100ms)




                                                                  C




                                                                                 *C is intentional off time.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                   Test report No.   : 10005487H-B-R1
                                                                   Page              : 20 of 25
                                                                   Issued date       : March 15, 2013
                                                                   Revised date      : March 21, 2013
                                                                   FCC ID            : HYQ1EA



                                                      Duty Cycle


                                                       20mS




                                                         20mS




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                   Test report No.   : 10005487H-B-R1
                                                                   Page              : 21 of 25
                                                                   Issued date       : March 15, 2013
                                                                   Revised date      : March 21, 2013
                                                                   FCC ID            : HYQ1EA


                                                      Duty Cycle


                            A         B                2mS




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                      Test report No.      : 10005487H-B-R1
                                                                                      Page                 : 22 of 25
                                                                                      Issued date          : March 15, 2013
                                                                                      Revised date         : March 21, 2013
                                                                                      FCC ID               : HYQ1EA


APPENDIX 2:Test Instruments

EMI test equipment
  Control No.         Instrument          Manufacturer        Model No        Serial No        Test Item   Calibration Date *
                                                                                                            Interval(month)
   MAEC-02      Semi Anechoic          TDK                Semi Anechoic   DA-06902           RE            2012/06/29 * 12
                Chamber(NSA)                              Chamber 3m
   MOS-22       Thermo-Hygrometer      Custom             CTH-201         0003               RE            2013/02/26 * 12
   MJM-14       Measure                KOMELON            KMC-36          -                  RE            -
 COTS-MEMI      EMI measurement        TSJ                TEPTO-DV        -                  RE            -
                program
  MRENT-95      Spectrum Analyzer      Agilent            E4440A          MY46185823         RE            2012/06/19 * 12
   MTR-03       Test Receiver          Rohde & Schwarz    ESCI            100300             RE            2012/04/03 * 12
   MBA-02       Biconical Antenna      Schwarzbeck        BBA9106         VHA91032008        RE            2012/10/08 * 12
   MLA-02       Logperiodic Antenna    Schwarzbeck        USLP9143        201                RE            2012/10/08 * 12
   MCC-12       Coaxial Cable          Fujikura/Agilent   -               -                  RE            2013/02/06 * 12
   MAT-07       Attenuator(6dB)        Weinschel Corp     2               BK7970             RE            2012/11/06 * 12
   MPA-09       Pre Amplifier          Agilent            8447D           2944A10845         RE            2012/09/11 * 12
   MHA-06       Horn Antenna 1-18GHz   Schwarzbeck        BBHA9120D       254                RE            2013/02/15 * 12
   MPA-10       Pre Amplifier          Agilent            8449B           3008A02142         RE            2013/01/10 * 12
   MCC-132      Microwave Cable        HUBER+SUHNER       SUCOFLEX104     336161/4(1m) /     RE            2012/09/05 * 12
                                                                          340639(5m)
   MSA-10       Spectrum Analyzer      Agilent            E4448A          MY46180655         RE            2013/02/22 * 12
   MLPA-06      Loop Antenna           UL Japan           -               -                  RE            Pre Check



The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test Item:
RE: Radiated emission, 99% Occupied Bandwidth, -20dB bandwidth , Automatically deactivate and Duty cycle tests




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124



Document Created: 2013-03-21 15:42:47
Document Modified: 2013-03-21 15:42:47

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC