FCC Report

FCC ID: HYQ14AHC

Test Report

Download: PDF
FCCID_2013652

                                                                                       Test report No.    : 1002481 5H—A
                                                                                       Page               : 1 of 18
                                                                                       Issued date        : July 4, 2013
                                                                                       FCC ID             : HYQI4AHC




                                   RADIO TEST REPORT
                                   Test Report No. : 10024815H—A
       Applicant                                f     DENSO CORPORATION

       Type of Equipment                        $     Electronic Key

       Model No.                                f     14AHC

       Test regulation                                FCC Part 15 Subpart C: 2012

       FCC ID                                         HYQI4AHC

       Test Result                              :f    Complied


                      This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
         in & o f —




                      The results in this report apply only to the sample tested.
                      This sample tested is in compliance with above regulation.
                      The test results in this report are traceable to the national or international standards.
                      This test report must not be used by the customer to claim product certification, approval, or endorsement
                      by NVLAP, NIST, or any agency of the Federal Government.


                              Date of test:                           June 30, 2013


                              Representative test
                              engineer:                         2PA        amerer
                                                                 * Mot’oya Imura
                                                                Engineer of WiSE Japan,
                                                                UL Verification Service


                              Approved by:                   e                   2          TR
                                                                  Masanori N'gs’/lfyarfi
                                                                Manager of WiSE Japan,
                                                                UL Verification Service




          nviad
                                                                 This laboratory is accredited by the NVLAP LAB CODE
                                                     ®           200572—0, U.S.A. The tests reported herein have been
                                                                 performed in accordance with its terms of accreditation.
                                                                 *As for the range of Accreditation in NVLAP, you may
                                                                 refer to the WEB address,
                                                                 http://www.ul.com/japan/jpn/pages/services/eme/about/ma
                                                                 rk1/index.jsp#nvlap
           NVLAP LAB CODE: 200572—0




UL Japan, Inc.
Head Office EMC Lab.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN
                                                                                                                13—EM—FO429
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                      Test report No.   : 10024815H-A
                                                                      Page              : 2 of 18
                                                                      Issued date       : July 4, 2013
                                                                      FCC ID            : HYQ14AHC




                                  REVISION HISTORY
                               Original Test Report No.: 10024815H-A

Revision     Test report No.         Date             Page      Contents
                                                      revised
-            10024815H-A             July 4, 2013     -         -
(Original)




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                                          Test report No.         : 10024815H-A
                                                                                                          Page                    : 3 of 18
                                                                                                          Issued date             : July 4, 2013
                                                                                                          FCC ID                  : HYQ14AHC


CONTENTS                                                                                                                                      PAGE

SECTION 1: Customer information ·············································································· 4
SECTION 2: Equipment under test (E.U.T.) ···································································· 4
SECTION 3: Test specification, procedures & results························································· 5
SECTION 4: Operation of E.U.T. during testing ······························································· 8
SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission) 9
SECTION 6: Automatically deactivate ········································································· 10
SECTION 7: -20dB and 99% Occupied Bandwidth ························································· 10
APPENDIX 1: Data of EMI test ·················································································· 11
    Automatically deactivate................................................................................................................... 11
    Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 12
    Duty Cycle ........................................................................................................................................ 13
    -20dB and 99% Occupied Bandwidth ............................................................................................... 14
APPENDIX 2:Test Instruments ··················································································· 15
APPENDIX 3: Photographs of test setup ······································································· 16
    Radiated emission ............................................................................................................................. 16
    Worst case position ........................................................................................................................... 17




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                 Test report No.   : 10024815H-A
                                                                                 Page              : 4 of 18
                                                                                 Issued date       : July 4, 2013
                                                                                 FCC ID            : HYQ14AHC


SECTION 1: Customer information
Company Name                           :    DENSO CORPORATION
Address                                :    1-1 Showa-cho, Kariya-shi, Aichi-ken, 448-8661 Japan
Telephone Number                       :    +81-566-61-7252
Facsimile Number                       :    +81-566-25-4792
Contact Person                         :    HIROMICHI HANAI


SECTION 2: Equipment under test (E.U.T.)
2.1     Identification of E.U.T.

Type of Equipment                      :    Electronic Key
Model No.                              :    14AHC
Serial No.                             :    Refer to Clause 4.2
Rating                                 :    DC 3.0V
Receipt Date of Sample                 :    June 25, 2013
Country of Mass-production             :    Japan, United States of America
Condition of EUT                       :    Engineering prototype
                                            (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                    :    No Modification by the test lab

2.2     Product Description

Model No: 14AHC (referred to as the EUT in this report) is the Electronic Key.

General Specification

Clock frequency(ies) in the system     :    8MHz

Radio Specification

Radio Type                             :    Transceiver
Frequency of Operation                 :    314.35MHz
Modulation                             :    FSK (F1D)
Power Supply (radio part input)        :    DC 3.0V
Type of Battery                        :    One lithium battery
Antenna type                           :    Built-in type (Fixed)




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                   Test report No.       : 10024815H-A
                                                                                   Page                  : 5 of 18
                                                                                   Issued date           : July 4, 2013
                                                                                   FCC ID                : HYQ14AHC


 SECTION 3: Test specification, procedures & results

 3.1     Test Specification

 Test Specification        :    Test specification: FCC Part 15 Subpart C: 2012, final revised on December 27, 2012
                                and effective January 28, 2013

 Title                     :    FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                Section 15.231 Periodic operation in the band 40.66 - 40.70MHz
                                and above 70MHz


 3.2     Procedures and results

Item                       Test Procedure          Specification             Worst margin            Results     Remarks
                           FCC: ANSI C63.4:2003    FCC: Section 15.207
                           7. AC powerline
                           conducted emission
Conducted emission         measurements                                      N/A                     N/A*1)      -
                           IC: RSS-Gen 7.2.4       IC: RSS-Gen 7.2.4


                           FCC: ANSI C63.4:2003    FCC: Section
                           13. Measurement of      15.231(a)(1)
Automatically Deactivate   intentional radiators                             N/A                     Complied    Radiated
                           IC: -                   IC: RSS-210 A1.1.1
                           FCC: ANSI C63.4:2003    FCC: Section 15.231(b)    3.2dB
Electric Field Strength    13. Measurement of                                314.35MHz
                           intentional radiators                                                     Complied    Radiated
of Fundamental Emission                                                      Horizontal
                           IC: RSS-Gen 4.8         IC: RSS-210 A1.1.2        PK wit Duty factor
                           FCC: ANSI C63.4:2003    FCC: Section 15.205
                           13. Measurement of            Section 15.209      3.3dB
Electric Field Strength    intentional radiators         Section 15.231(b)   1886.100MHz
                                                                                                     Complied    Radiated
of Spurious Emission       IC: RSS-Gen 4.9         IC: RSS-210 A1.1.2,       Horizontal
                                                   2.5.1                     PK wit Duty factor
                                                        RSS-Gen 7.2.5
                           FCC: ANSI C63.4:2003    FCC: Section 15.231(c)
                           13. Measurement of
-20dB Bandwidth            intentional radiators                             N/A                     Complied    Radiated
                           IC: -                   IC: Reference data

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT does not have AC Mains.

 FCC 15.31 (e)
 This test was performed with the New Battery (DC 3.0V) and the constant voltage was supplied to the EUT during the
 tests. Therefore, the EUT complies with the requirement.

 FCC Part 15.203 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.




 UL Japan, Inc.
 Head Office EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone       : +81 596 24 8999
 Facsimile       : +81 596 24 8124


                                                                                              Test report No.       : 10024815H-A
                                                                                              Page                  : 6 of 18
                                                                                              Issued date           : July 4, 2013
                                                                                              FCC ID                : HYQ14AHC



3.3       Addition to standard

  Item                       Test Procedure       Specification             Worst margin         Results        Remarks
  99% Occupied
                             IC: RSS-Gen 4.6.1    IC: RSS-Gen 4.6.1         N/A                  N/A            Radiated
  Bandwidth
 Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4       Uncertainty

EMI
The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2.
   Test room                                               Radiated emission
   (semi-                              (3m*)(+dB)                               (1m*)(+dB)            (0.5m*)(+dB)
   anechoic            9kHz        30MHz       300MHz         1GHz          10GHz         18GHz          26.5GHz
   chamber)          -30MHz       -300MHz -1GHz              -10GHz        -18GHz       -26.5GHz          -40GHz
   No.1               4.3dB         5.0dB        5.1dB        4.9dB         5.8dB         4.4dB            4.3dB
   No.2               4.3dB         5.2dB        5.1dB        5.0dB         5.7dB         4.3dB            4.2dB
   No.3               4.6dB         5.0dB        5.1dB        5.0dB         5.7dB         4.5dB            4.2dB
   No.4               4.8dB         5.2dB        5.0dB        5.0dB         5.7dB         5.2dB            4.2dB
*3m/1m/0.5m = Measurement distance

Radiated emission test(3m)
The data listed in this report meets the limits unless the uncertainty is taken into consideration.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                    Test report No.    : 10024815H-A
                                                                                    Page               : 7 of 18
                                                                                    Issued date        : July 4, 2013
                                                                                    FCC ID             : HYQ14AHC



3.5      Test Location

UL Japan, Inc. Head Office EMC Lab. *NVLAP Lab. code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999          Facsimile : +81 596 24 8124
                        FCC           IC Registration    Width x Depth x      Size of                        Other
                        Registration Number              Height (m)           reference ground plane (m) /   rooms
                        Number                                                horizontal conducting plane
 No.1 semi-anechoic     313583        2973C-1            19.2 x 11.2 x 7.7m   7.0 x 6.0m                     No.1 Power
 chamber                                                                                                     source room
 No.2 semi-anechoic     655103        2973C-2            7.5 x 5.8 x 5.2m     4.0 x 4.0m                     -
 chamber
 No.3 semi-anechoic     148738        2973C-3            12.0 x 8.5 x 5.9m    6.8 x 5.75m                    No.3
 chamber                                                                                                     Preparation
                                                                                                             room
 No.3 shielded room    -              -                  4.0 x 6.0 x 2.7m     N/A                            -
 No.4 semi-anechoic    134570         2973C-4            12.0 x 8.5 x 5.9m    6.8 x 5.75m                    No.4
 chamber                                                                                                     Preparation
                                                                                                             room
 No.4 shielded room    -              -                  4.0 x 6.0 x 2.7m     N/A                            -
 No.5 semi-anechoic    -              -                                                                      -
                                                         6.0 x 6.0 x 3.9m     6.0 x 6.0m
 chamber
 No.6 shielded         -              -                  4.0 x 4.5 x 2.7m     4.75 x 5.4 m                   -
 room
 No.6 measurement      -              -                  4.75 x 5.4 x 3.0m    4.75 x 4.15 m                  -
 room
 No.7 shielded room    -              -                  4.7 x 7.5 x 2.7m     4.7 x 7.5m                     -
 No.8 measurement       -              -               3.1 x 5.0 x 2.7m      N/A                             -
 room
 No.9 measurement       -              -               8.8 x 4.6 x 2.8m      2.4 x 2.4m                      -
 room
 No.11 measurement      -              -               3.1 x 3.4 x 3.0m      2.4 x 3.4m                      -
 room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0m for No.1, No.2, No.3, and     No.4 semi-anechoic
chambers and No.3 and No.4 shielded rooms.



3.6    Data of EMI, Test instruments, and Test set up.

Refer to APPENDIX.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                Test report No.     : 10024815H-A
                                                                                Page                : 8 of 18
                                                                                Issued date         : July 4, 2013
                                                                                FCC ID              : HYQ14AHC


SECTION 4: Operation of E.U.T. during testing

4.1     Operating Modes

Test Item*                                             Mode
Automatically Deactivate                               Transmitting mode (Tx), 314.35MHz
Electric Field Strength of Fundamental Emission
Electric Field Strength of Spurious Emission
-20dB & 99% Occupied Bandwidth
* The system was configured in typical fashion (as a customer would normally use it) for testing.


4.2 Configuration and peripherals


                                                            A:EUT




                                     * Test data was taken under worse case conditions.

Description of EUT
 No. Item                         Model number        Serial number Manufacturer                  Remarks
 A    Electronic Key              14AHC               001 *1)       DENSO                         EUT
                                                      002 *2)       CORPORATION
*1) Used for Transmitting mode
*2) Used for Normal use mode




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                Test report No.    : 10024815H-A
                                                                                Page               : 9 of 18
                                                                                Issued date        : July 4, 2013
                                                                                FCC ID             : HYQ14AHC


SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious
Emission)
Test Procedure and conditions

EUT was placed on a urethane platform of nominal size, 0.5m by 1.0m, raised 0.8m above the conducting ground plane.
The EUT was set on the center of the tabletop.
Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement
antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.
Photographs of the set up are shown in Appendix 1.

[Transmitting mode]

(Below 30MHz)
The noise level was checked by moving a search-coil (Loop Antenna) close to the EUT.

(Above 30MHz)
The Radiated Electric Field Strength has been measured on Semi anechoic chamber with a ground plane and at a distance
of 3m.
The measuring antenna height was varied between 1 and 4m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver/spectrum
analyzer.

Test Antennas are used as below;
   Frequency          Below 30MHz              30MHz to 300MHz          300MHz to 1GHz            Above 1GHz
   Antenna Type       Loop                     Biconical                Logperiodic               Horn

                    From 9kHz       From 90kHz          From           From           From        Above 1GHz
                   to 90kHz and      to 110kHz        150kHz         490kHz          30MHz
                   From 110kHz                       to 490kHz      to 30MHz        to 1GHz
                     to 150kHz
   Detector             Peak            Peak           Peak           Peak         Peak and        Peak and Peak with
   Type                                                                           Peak with           Duty factor
                                                                                  Duty factor
   IF                  200Hz           200Hz          9.1kHz         9.1kHz        120kHz         PK: S/A:RBW 1MHz,
   Bandwidth                                                                                              VBW 3MHz

- The carrier level was measured at each position of all three axes X, Y and Z, and the position that has the maximum
noise was determined.
Noise levels of all the frequencies were measured at the position.

This EUT has two modes which mechanical key is inserted or not. The worst case was confirmed with and without
mechanical key, as a result, the test without mechanical key was the worst case. Therefore the test without mechanical
key was performed only.

*The result is rounded off to the second decimal place, so some differences might be observed.

Measurement range                  : 9kHz-3.2GHz
Test data                          : APPENDIX
Test result                        : Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                            Test report No.      : 10024815H-A
                                                                                            Page                 : 10 of 18
                                                                                            Issued date          : July 4, 2013
                                                                                            FCC ID               : HYQ14AHC


SECTION 6: Automatically deactivate
Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data                                : APPENDIX
Test result                              : Pass



SECTION 7: -20dB and 99% Occupied Bandwidth
Test Procedure

The measurement was performed in the antenna height to gain the maximum of Electric field strength.

Test               Span                       RBW           VBW             Sweep           Detector Trace            Instrument used
20dB Bandwidth     300kHz                     3kHz          9.1kHz          Auto            Peak        Max Hold      Spectrum Analyzer
99% Occupied       Enough width to display    1 % of Span   Three times     Auto            Peak *1)    Max Hold      Spectrum Analyzer
Bandwidth          20dB Bandwidth                           of RBW                                      *1)

*1) The measurement was performed with Peak detector, Max Hold since two peaks of the FSK moduration was not 100%.

Test data                                : APPENDIX
Test result                              : Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                       Test report No.   : 10024815H-A
                                                                       Page              : 11 of 18
                                                                       Issued date       : July 4, 2013
                                                                       FCC ID            : HYQ14AHC


APPENDIX 1: Data of EMI test

                                          Automatically deactivate

                Test place                No.4 Semi Anechoic Chamber
                Report No.                10024815H
                Date                      06/30/2013
                Temperature/ Humidity     24 deg. C / 61% RH
                Engineer                  Motoya Imura
                Mode                      Transmitting 314.35MHz

                             Time of                     Limit              Result
                           Transmitting
                              [sec]                      [sec]
                              0.617                      5.00                Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                                                       Test report No.             : 10024815H-A
                                                                                                                       Page                        : 12 of 18
                                                                                                                       Issued date                 : July 4, 2013
                                                                                                                       FCC ID                      : HYQ14AHC




           Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
                        Test place                               Head Office EMC Lab. No. 4 Semi Anechoic Chamber
                        Report No.                               10024815H
                        Date                                     06/30/2013
                        Temperature/ Humidity                    24 deg. C / 61% RH
                        Engineer                                 Motoya Imura
                        Mode                                     Transmitting 314.35MHz
  PK
   Frequency    Detector         Reading         Ant      Loss       Gain      Duty            Result       Limit           Margin                   Remark
                                 [dBuV]         Factor                        Factor        [dBuV/m]                         [dB]               Inside or Outside
    [MHz]                    Hor        Ver    [dB/m]     [dB]       [dB]      [dB]        Hor        Ver [dBuV/m]       Hor      Ver          of Restricted Bands
    314.350 PK                 77.7      72.9     16.6      10.0       32.0          -      72.3       67.5   95.5        23.2     28.0     Carrier
    628.700 PK                 41.9      38.0     20.7      11.9       32.2          -      42.3       38.4   75.5        33.2     37.1     Outside
    943.050 PK                 31.3      30.4     25.1      13.6       31.0          -      39.0       38.1   75.5        36.5     37.4     Outside
   1257.400 PK                 45.0      44.5     25.0        1.9      34.2          -      37.7       37.2   75.5        37.8     38.3     Outside
   1571.750 PK                 47.8      52.2     25.7        2.1      33.5          -      42.1       46.5   73.9        31.8     27.4     Inside
   1886.100 PK                 55.6      55.1     27.2        2.3      32.9          -      52.2       51.7   75.5        23.3     23.8     Outside
   2200.450 PK                 45.3      43.2     27.6        2.5      32.5          -      42.9       40.8   73.9        31.0     33.1     Inside
   2514.800 PK                 41.6      42.2     27.5        2.7      32.4          -      39.4       40.0   75.5        36.1     35.5     Outside
   2829.150 PK                 42.0      41.2     28.2        2.9      32.2          -      40.9       40.1   73.9        33.0     33.8     Inside
   3143.500 PK                 41.8      40.8     28.7        3.0      32.1          -      41.4       40.4   75.5        34.1     35.1     Outside
  Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier)



  PK with Duty factor
   Frequency Detector            Reading         Ant      Loss       Gain      Duty           Result          Limit           Margin                  Remark
                                 [dBuV]         Factor                        Factor        [dBuV/m]                           [dB]
    [MHz]                    Hor        Ver    [dB/m]     [dB]       [dB]      [dB]       Hor        Ver [dBuV/m] Hor               Ver
    314.350 PK                 77.7      72.9     16.6      10.0       32.0       0.0      72.3       67.5       75.5        3.2      8.0   Carrier
    628.700 PK                 41.9      38.0     20.7      11.9       32.2       0.0      42.3       38.4       55.5       13.2     17.1   Outside
    943.050 PK                 31.3      30.4     25.1      13.6       31.0       0.0      39.0       38.1       55.5       16.5     17.4   Outside
   1257.400 PK                 45.0      44.5     25.0        1.9      34.2       0.0      37.7       37.2       55.5       17.8     18.3   Outside
   1571.750 PK                 47.8      52.2     25.7        2.1      33.5       0.0      42.1       46.5       53.9       11.8      7.4   Inside
   1886.100 PK                 55.6      55.1     27.2        2.3      32.9       0.0      52.2       51.7       55.5        3.3      3.8   Outside
   2200.450 PK                 45.3      43.2     27.6        2.5      32.5       0.0      42.9       40.8       53.9       11.0     13.1   Inside
   2514.800 PK                 41.6      42.2     27.5        2.7      32.4       0.0      39.4       40.0       55.5       16.1     15.5   Outside
   2829.150 PK                 42.0      41.2     28.2        2.9      32.2       0.0      40.9       40.1       53.9       13.0     13.8   Inside
   3143.500 PK                 41.8      40.8     28.7        3.0      32.1       0.0      41.4       40.4       55.5       14.1     15.1   Outside
  Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier) + Duty factor (Refer to Duty factor data sheet)

  *Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).
  *NS : No signal detected.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                             Test report No.     : 10024815H-A
                                                                             Page                : 13 of 18
                                                                             Issued date         : July 4, 2013
                                                                             FCC ID              : HYQ14AHC




                                                      Duty Cycle
                     Test place                Head Office EMC Lab. No.4 Semi Anechoic Chamber
                     Report No.                10024815H
                     Date                      06/30/2013
                     Temperature/ Humidity     24 deg. C / 61% RH
                     Engineer                  Motoya Imura
                     Mode                      Transmitting 314.35MHz

                    【314.35MHz】: Duty is 100%




                                             The switch is pushed on




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                            Test report No.   : 10024815H-A
                                                                            Page              : 14 of 18
                                                                            Issued date       : July 4, 2013
                                                                            FCC ID            : HYQ14AHC


                                   -20dB and 99% Occupied Bandwidth
                Test place                 No.4 Semi Anechoic Chamber
                Report No.                 10024815H
                Date                       06/30/2013
                Temperature/ Humidity      24 deg. C / 61% RH
                Engineer                   Motoya Imura
                Mode                       Transmitting 314.35MHz


                Bandwidth Limit : Fundamental Frequency      314.35 MHz x 0.25% =    785.88   kHz



                     -20dB Bandwidth            Bandwidth Limit         Result
                          [kHz]                      [kHz]
                          61.28                     785.88               Pass

                  99% Occupied Bandwidth        Bandwidth Limit         Result
                          [kHz]                      [kHz]
                          59.06                     785.88               Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124


                                                                                      Test report No.      : 10024815H-A
                                                                                      Page                 : 15 of 18
                                                                                      Issued date          : July 4, 2013
                                                                                      FCC ID               : HYQ14AHC


APPENDIX 2:Test Instruments

EMI test equipment
  Control No.         Instrument          Manufacturer         Model No       Serial No        Test Item   Calibration Date *
                                                                                                            Interval(month)
   MAEC-04      Semi Anechoic          TDK               Semi Anechoic    DA-10005           RE            2013/02/28 * 12
                Chamber(NSA)                             Chamber 3m
   MOS-15       Thermo-Hygrometer      Custom            CTH-180          -                  RE            2013/02/26 * 12
   MJM-09       Measure                KDS               E19-55           -                  RE            -
 COTS-MEMI      EMI measurement        TSJ               TEPTO-DV         -                  RE            -
                program
  MRENT-95      Spectrum Analyzer      Agilent           E4440A           MY46185823         RE            2013/06/14 * 12
   MTR-07       Test Receiver          Rohde & Schwarz   ESCI             100635             RE            2013/04/10 * 12
   MBA-05       Biconical Antenna      Schwarzbeck       BBA9106          1302               RE            2012/11/18 * 12
   MLA-08       Logperiodic Antenna    Schwarzbeck       UKLP9140-A       N/A                RE            2012/11/18 * 12
   MCC-50       Coaxial Cable          UL Japan          -                -                  RE            2013/06/18 * 12
   MAT-68       Attenuator             Anritsu           MP721B           6200961025         RE            2012/11/21 * 12
   MPA-14       Pre Amplifier          SONOMA            310              260833             RE            2013/03/12 * 12
                                       INSTRUMENT
   MHA-21       Horn Antenna 1-18GHz   Schwarzbeck       BBHA9120D        9120D-557          RE            2012/08/17 * 12
   MCC-141      Microwave Cable        Junkosha          MWX221           1305S002R(1m) / RE               2013/05/28 * 12
                                                                          1204S062(5m)
   MPA-12       MicroWave System       Agilent           83017A           MY39500780         RE            2013/03/19 * 12
                Amplifier
   MLPA-06      Loop Antenna           UL Japan          -                -                  RE            Pre Check


The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test Item:
RE: Radiated emission, 99% Occupied Bandwidth, -20dB bandwidth , Automatically deactivate and Duty cycle tests




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124



Document Created: 2013-07-05 11:30:08
Document Modified: 2013-07-05 11:30:08

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC