                                                                                 Test report No.        : 12496758H-A-R1
                                                                                 Page                   : 1 of 20
                                                                                 Issued date            : November 1, 2018
                                                                                 FCC ID                 : HYQ12BFZ




                              RADIO TEST REPORT
                                Test Report No. : 12496758H-A-R1
        Applicant                             :     DENSO CORPORATION

        Type of Equipment                     :     Remote Keyless Entry System (Transmitter)

        Model No.                             :     12BFZ

        FCC ID                                :     HYQ12BFZ

        Test regulation                       :     FCC Part 15 Subpart C: 2018

        Test Result                           :     Complied
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           6.   This test report covers Radio technical requirements. It does not cover administrative issues
                such as Manual or non-Radio test related Requirements. (if applicable)
           7.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           8.   This report is a revised version of 12496758H-A. 12496758H-A is replaced with this report.

                         Date of test:                          September 20, 2018

                         Representative test
                         engineer:
                                                               Akihiko Maeda
                                                                  Engineer
                                                         Consumer Technology Division


                         Approved by:
                                                               Motoya Imura
                                                                   Leader
                                                         Consumer Technology Division

                                                            This laboratory is accredited by the NVLAP LAB CODE
                                                            200572-0, U.S.A. The tests reported herein have been
                                                            performed in accordance with its terms of accreditation.
                                                            *As for the range of Accreditation in NVLAP, you may
                                                            refer to the WEB address,
                                                            http://japan.ul.com/resources/emc_accredited/

       NVLAP LAB CODE: 200572-0

    The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
    There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                                             13-EM-F0429


                                                                     Test report No.     : 12496758H-A-R1
                                                                     Page                : 2 of 20
                                                                     Issued date         : November 1, 2018
                                                                     FCC ID              : HYQ12BFZ




                                  REVISION HISTORY
                             Original Test Report No.: 12496758H-A

Revision       Test report No.       Date             Page revised   Contents
-              12496758H-A           October 17,      -              -
(Original)                           2018
1              12496758H-A-R1        November 1,      P.9            Correction of description of Test Procedure
                                     2018                            and conditions in SECTION 5.
1              12496758H-A-R1        November 1,      P.16           Correction of “Total on time” in table for
                                     2018                            Duty Cycle;
                                                                     From 20 mS to 50 mS




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                Test report No.             : 12496758H-A-R1
                                                                                                Page                        : 3 of 20
                                                                                                Issued date                 : November 1, 2018
                                                                                                FCC ID                      : HYQ12BFZ


CONTENTS                                                                                                                                 PAGE

SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test specification, procedures & results..........................................................................5
SECTION 4: Operation of E.U.T. during testing ..................................................................................8
SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission)9
SECTION 6: Automatically deactivate ................................................................................................11
SECTION 7: -20 dB and 99 % Occupied Bandwidth .........................................................................11
APPENDIX 1: Test data ........................................................................................................................12
    Automatically deactivate................................................................................................................... 12
    Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 13
    -20dB and 99% Occupied Bandwidth ............................................................................................... 15
    Duty Cycle ........................................................................................................................................ 16
APPENDIX 2: Test instruments ...........................................................................................................18
APPENDIX 3: Photographs of test setup .............................................................................................19
    Radiated emission ............................................................................................................................. 19
    Worst case position ........................................................................................................................... 20




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.      : 12496758H-A-R1
                                                                       Page                 : 4 of 20
                                                                       Issued date          : November 1, 2018
                                                                       FCC ID               : HYQ12BFZ


SECTION 1:         Customer information
Company Name                           :    DENSO CORPORATION
Address                                :    1-1, Showa-cho, Kariya-shi, Aichi-ken, 448-8661, Japan
Telephone Number                       :    +81-566-20-3953
Facsimile Number                       :    +81-566-25-4837
Contact Person                         :    MASASHI URABE



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

Type of Equipment                      :    Remote Keyless Entry System (Transmitter)
Model No.                              :    12BFZ
Serial No.                             :    Refer to Section 4, Clause 4.2
Rating                                 :    DC 3.0 V
Receipt Date of Sample                 :    September 12, 2018
Country of Mass-production             :    Japan
Condition of EUT                       :    Production prototype
                                            (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                    :    No Modification by the test lab


2.2       Product Description

Model: 12BFZ (referred to as the EUT in this report) is a Remote Keyless Entry System (Transmitter).

Radio Specification

Radio Type                             :    Transmitter
Frequency of Operation                 :    433.92 MHz
Clock frequency(ies) in the system     :    33.6 MHz Crystal
Modulation                             :    ASK (A1D)
Type of Battery                        :    One lithium battery
Antenna type                           :    Built-in type (Fixed)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                    Test report No.          : 12496758H-A-R1
                                                                                    Page                     : 5 of 20
                                                                                    Issued date              : November 1, 2018
                                                                                    FCC ID                   : HYQ12BFZ


 SECTION 3:               Test specification, procedures & results

 3.1        Test Specification

 Test Specification            :      FCC Part 15 Subpart C
                                      FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

 Title                         :      FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                      Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.


 3.2        Procedures and results

Item                          Test Procedure          Specification                  Worst margin Results              Remarks
                              FCC: ANSI C63.10:2013 FCC: Section 15.207
                              6 Standard test methods
Conducted emission                                                                   N/A *1)           N/A             -
                              IC: RSS-Gen 8.8            IC: RSS-Gen 8.8


                              FCC: ANSI C63.10:2013 FCC: Section
                              6 Standard test methods 15.231(a)(1)
Automatically Deactivate                                                             N/A               Complied        Radiated
                              IC: -                      IC: RSS-210 A1.1
                              FCC: ANSI C63.10:2013 FCC: Section 15.231(b)
                              6 Standard test methods                                5.3 dB
Electric Field Strength
                                                                                     433.920 MHz       Complied        Radiated
of Fundamental Emission
                              IC: RSS-Gen 6.12           IC: RSS-210 A1.2            Horizontal

                              FCC: ANSI C63.10:2013 FCC: Section 15.205
                              6 Standard test methods      Section 15.209            11.6 dB
Electric Field Strength
                                                           Section 15.231(b)         4339.200 MHz Complied             Radiated
of Spurious Emission
                              IC: RSS-Gen 6.13        IC: RSS-210 A1.2, 4.4          Horizontal
                                                          RSS-Gen 8.9
                              FCC: ANSI C63.10:2013 FCC: Section 15.231(c)
                              6 Standard test methods
-20dB Bandwidth                                                                      N/A               Complied        Radiated
                              IC: -                      IC: Reference data

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT does not have AC Mains.
Symbols:
 Complied                The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#              The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.

 FCC 15.31 (e)
 This test was performed with the New Battery (DC 3.0 V) during the tests. Therefore, the EUT complies with the
 requirement.

 FCC Part 15.203 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone : +81 596 24 8999
 Facsimile : +81 596 24 8124


                                                                                  Test report No.        : 12496758H-A-R1
                                                                                  Page                   : 6 of 20
                                                                                  Issued date            : November 1, 2018
                                                                                  FCC ID                 : HYQ12BFZ


 3.3         Addition to standard

Item                        Test Procedure       Specification           Worst margin        Results      Remarks
99 % Occupied
                            IC: RSS-Gen 6.6      IC: RSS-210 A1.3        N/A                 Complied     Radiated
Bandwidth
 Other than above, no addition, exclusion nor deviation has been made from the standard.


 3.4         Uncertainty

 The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.


                                       Radiated emission
           Test distance                     (+/-)

                                        9 kHz to 30 MHz
   3m                                       3.8 dB
   10 m                                     3.6 dB
 *Measurement distance

                                                Radiated emission (Below 1 GHz)
       Polarity                     (3 m*)(+/-)                                 (10 m*)(+/-)
                     30 MHz to 200 MHz    200 MHz to 1000 MHz    30 MHz to 200 MHz    200 MHz to 1000 MHz
       Horizontal         4.8 dB                5.2 dB                  4.8 dB               5.0 dB
        Vertical          5.0 dB                6.3 dB                  4.9 dB               5.0 dB

                                              Radiated emission (Above 1 GHz)
                  (3 m*)(+/-)                                     (1 m*)(+/-)                             (10 m*)(+/-)
     1 GHz to 6 GHz      6 GHz to 18 GHz        10 GHz to 26.5 GHz      26.5 GHz to 40 GHz              1 GHz to 18 GHz
          5.2 dB              5.5 dB                   5.9 dB                 5.9 dB                         5.5 dB
 * Measurement distance




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone : +81 596 24 8999
 Facsimile : +81 596 24 8124


                                                                                       Test report No.          : 12496758H-A-R1
                                                                                       Page                     : 7 of 20
                                                                                       Issued date              : November 1, 2018
                                                                                       FCC ID                   : HYQ12BFZ


3.5         Test Location

UL Japan, Inc. Ise EM C Lab.
4383-326 Asama-cho, Ise-shi, M ie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                            M aximum
                        IC Registration   Width x Depth x       Size of reference ground plane (m) /
Test site                                                                                                Other rooms        measurement
                        Number            Height (m)            horizontal conducting plane
                                                                                                                            distance
No.1 semi-anechoic                                                                                       No.1 Power source
                        2973C-1           19.2 x 11.2 x 7.7     7.0 x 6.0                                                  10 m
chamber                                                                                                  room
No.2 semi-anechoic
                        2973C-2           7.5 x 5.8 x 5.2       4.0 x 4.0                                -                  3m
chamber
No.3 semi-anechoic                                                                                       No.3 Preparation
                        2973C-3           12.0 x 8.5 x 5.9      6.8 x 5.75                                                  3m
chamber                                                                                                  room
No.3 shielded room      -                 4.0 x 6.0 x 2.7       N/A                                      -                  -
No.4 semi-anechoic                                                                                       No.4 Preparation
                        2973C-4           12.0 x 8.5 x 5.9      6.8 x 5.75                                                  3m
chamber                                                                                                  room
No.4 shielded room      -                 4.0 x 6.0 x 2.7       N/A                                      -                  -
No.5 semi-anechoic
                        -                 6.0 x 6.0 x 3.9       6.0 x 6.0                                -                  -
chamber
No.6 shielded room      -                 4.0 x 4.5 x 2.7       4.0 x 4.5                                -                  -
No.6 measurement
                        -                 4.75 x 5.4 x 3.0      4.75 x 4.15                              -                  -
room
No.7 shielded room      -                 4.7 x 7.5 x 2.7       4.7 x 7.5                                -                  -
No.8 measurement
                        -                 3.1 x 5.0 x 2.7       N/A                                      -                  -
room
No.9 measurement
                        -                 8.8 x 4.6 x 2.8       2.4 x 2.4                                -                  -
room
No.11 measurement
                        -                 6.2 x 4.7 x 3.0       4.8 x 4.6                                -                  -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4 semi-
anechoic chambers and No.3 and No.4 shielded rooms.



3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.       : 12496758H-A-R1
                                                                          Page                  : 8 of 20
                                                                          Issued date           : November 1, 2018
                                                                          FCC ID                : HYQ12BFZ


SECTION 4:         Operation of E.U.T. during testing

4.1       Operating Mode(s)

Test Item*                                              Mode
Automatically Deactivate                                Normal use mode
Electric Field Strength of Fundamental Emission         Transmitting mode (Tx) *1)
Electric Field Strength of Spurious Emission
-20 dB & 99 % Occupied Bandwidth
Duty Cycle
* The system was configured in typical fashion (as a user would normally use it) for testing.
*1) End users cannot change the settings of the output power of the product.


4.2       Configuration and peripherals




                                                           A




* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.

Description of EUT
 No. Item                       Model number          Serial number         Manufacturer                      Remarks
 A     Remote Keyless Entry 12BFZ                     No.1 *1)              DENSO CORPORATION                 EUT
       System (Transmitter)                           No.2 *2)
*1) Used for Transmitting mode.
*2) Used for Normal use mode.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.       : 12496758H-A-R1
                                                                            Page                  : 9 of 20
                                                                            Issued date           : November 1, 2018
                                                                            FCC ID                : HYQ12BFZ


SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious
Emission)
Test Procedure and conditions

[For below 30 MHz]
The noise level was checked by moving a search-coil (Loop Antenna) close to the EUT.

[For 30 MHz to 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground
plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined
on a ground plane.

The measuring antenna height was varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver / spectrum
analyzer.

Test Antennas are used as below;
   Frequency            Below 30 MHz             30 MHz to 200 MHz          200 MHz to 1 GHz         Above 1 GHz
   Antenna Type         Loop                     Biconical                  Logperiodic              Horn

                   From 9 kHz        From           From           From                From              Above 1 GHz
                     to 90 kHz   90 kHz to 110    150 kHz        490 kHz              30 MHz
                        and          kHz         to 490 kHz     to 30 MHz            to 1 GHz
                  From 110 kHz
                   to 150 kHz
   Detector            Peak          Peak             Peak           Peak            Peak and     Peak and
   Type                                                                             Peak with     Peak with
                                                                                    Duty factor   Duty factor
   IF               200 Hz          200 Hz         9.1 kHz       9.1 kHz             120 kHz      PK: S/A: RBW 1 MHz,
   Bandwidth                                                                                              VBW: 3 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.        : 12496758H-A-R1
                                                                            Page                   : 10 of 20
                                                                            Issued date            : November 1, 2018
                                                                            FCC ID                 : HYQ12BFZ


Figure 1: Test Setup

Below 1 GHz
                                                               Test Distance: 3 m




1 GHz - 10 GHz
                                                               Distance Factor: 20 x log (3.75 m / 3.0 m) = 1.94 dB
                                                               * Test Distance: (3 + Test Volume /2) - r = 3.75 m

                                                               Test Volume : 1.5 m
                                                               (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                                r = 0.0 m

                                                               * The test was performed with r = 0.0 m since EUT is small
                                                               and it was the rather conservative condition.




- The carrier level (or, noise levels) was (or were) measured at each position of all three axes X, Y and Z, and the
position that has the maximum noise was determined.
Noise levels of all the frequencies were measured at the position.

*The result is rounded off to the second decimal place, so some differences might be observed.


Measurement range               : 9 kHz - 4.4 GHz
Test data                       : APPENDIX
Test result                     : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.      : 12496758H-A-R1
                                                                               Page                 : 11 of 20
                                                                               Issued date          : November 1, 2018
                                                                               FCC ID               : HYQ12BFZ


SECTION 6:            Automatically deactivate

Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data                           : APPENDIX
Test result                         : Pass



SECTION 7:            -20 dB and 99 % Occupied Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test               Span                       RBW        VBW           Sweep           Detector   Trace       Instrument used
20 dB Bandwidth     300 kHz                   3 kHz      9.1 kHz       Auto            Peak       Max Hold    Spectrum Analyzer
99 % Occupied       Enough width to display   1 to 5 %   Three times   Auto            Peak       Max Hold    Spectrum Analyzer
Bandwidth           emission skirts           of OBW     of RBW
Peak hold was applied as Worst-case measurement.

Test data                           : APPENDIX
Test result                         : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                Test report No.   : 12496758H-A-R1
                                                                Page              : 12 of 20
                                                                Issued date       : November 1, 2018
                                                                FCC ID            : HYQ12BFZ


APPENDIX 1: Test data

                                          Automatically deactivate

            Report No.                 12496758H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.2
            Date                       September 20, 2018
            Temperature / Humidity     23 deg. C / 63 % RH
            Engineer                   Akihiko Maeda
            Mode                       Normal use mode

                   Tx Freq                Time of             Limit               Result
                                        Transmitting
                    [MHz]                   [sec]             [sec]
                    433.92                 0.7417             5.00                 Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                  Test report No.            : 12496758H-A-R1
                                                                                                  Page                       : 13 of 20
                                                                                                  Issued date                : November 1, 2018
                                                                                                  FCC ID                     : HYQ12BFZ


      Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
               Report No.                         12496758H
               Test place                         Ise EMC Lab.
               Semi Anechoic Chamber              No.2
               Date                               September 20, 2018
               Temperature / Humidity             23 deg. C / 63 % RH
               Engineer                           Akihiko Maeda
               Mode                               Transmitting mode, 433.92 MHz

     QP or PK
      Frequency      Detector     Reading          Ant     Loss     Gain      Duty           Result       Limit       Margin                 Remark
                                  [dBuV]         Factor                      Factor        [dBuV/m]                    [dB]             Inside or Outside
        [MHz]                   Hor     Ver      [dB/m]    [dB]     [dB]      [dB]        Hor       Ver [dBuV/m]   Hor      Ver       of Restricted Bands
          433.920   PK           84.9     84.3      16.1      9.5     29.8            -    80.7      80.1  100.8    20.1     20.7   Carrier
          867.840   PK           35.3     34.3      21.8     11.2     28.2            -    40.1      39.1   80.8    40.7     41.7   Outside
         1301.760   PK           46.6     46.4      25.8      5.5     35.3            -    42.6      42.4   73.9    31.3     31.5   Inside
         1735.680   PK           45.5     46.3      24.9      5.1     34.8            -    40.7      41.5   80.8    40.1     39.3   Outside
         2169.600   PK           44.3     45.1      27.9      5.2     34.5            -    42.9      43.7   80.8    37.9     37.1   Outside
         2603.520   PK           44.5     44.2      27.4      5.3     34.4            -    42.8      42.5   80.8    38.0     38.3   Outside
         3037.440   PK           44.6     45.1      28.5      5.4     34.3            -    44.2      44.7   80.8    36.6     36.1   Outside
         3471.360   PK           44.7     45.3      29.2      5.6     33.9            -    45.6      46.2   80.8    35.2     34.6   Outside
         3905.280   PK           44.1     44.4      29.8      5.7     33.6            -    46.0      46.3   73.9    27.9     27.6   Inside
         4339.200   PK           44.5     44.1      30.6      6.0     33.6            -    47.5      47.1   73.9    26.4     26.8   Inside



     PK with Duty factor
       Frequency     Detector     Reading          Ant     Loss     Gain      Duty           Result       Limit       Margin                  Remark
                                  [dBuV]         Factor                      Factor        [dBuV/m]                    [dB]
        [MHz]                   Hor     Ver      [dB/m]    [dB]     [dB]      [dB]        Hor       Ver [dBuV/m]   Hor      Ver
          433.920   PK           84.9     84.3      16.1      9.5     29.8      -5.2       75.5      74.9   80.8     5.3      5.9   Carrier
          867.840   PK           35.3     34.3      21.8     11.2     28.2      -5.2       34.9      33.9   60.8    25.9     26.9   Outside
         1301.760   PK           46.6     46.4      25.8      5.5     35.3      -5.2       37.4      37.2   53.9    16.5     16.7   Inside
         1735.680   PK           45.5     46.3      24.9      5.1     34.8      -5.2       35.5      36.3   60.8    25.3     24.5   Outside
         2169.600   PK           44.3     45.1      27.9      5.2     34.5      -5.2       37.7      38.5   60.8    23.1     22.3   Outside
         2603.520   PK           44.5     44.2      27.4      5.3     34.4      -5.2       37.6      37.3   60.8    23.2     23.5   Outside
         3037.440   PK           44.6     45.1      28.5      5.4     34.3      -5.2       39.0      39.5   60.8    21.8     21.3   Outside
         3471.360   PK           44.7     45.3      29.2      5.6     33.9      -5.2       40.4      41.0   60.8    20.4     19.8   Outside
         3905.280   PK           44.1     44.4      29.8      5.7     33.6      -5.2       40.8      41.1   53.9    13.1     12.8   Inside
         4339.200   PK           44.5     44.1      30.6      6.0     33.6      -5.2       42.3      41.9   53.9    11.6     12.0   Inside


Sample calculation:
Result of PK = Reading + Ant Factor + Loss {Cable + Attenuator + Filter (above 1GHz) +Distance factor (above 1 GHz)} - Gain
(Amplifier)

Result of PK with Duty factor = Reading + Ant Factor + Loss {Cable + Attenuator + Filter (above 1 GHz) +Distance factor (above
1 GHz)} - Gain (Amplifier) + Duty factor (Refer to Duty factor data sheet)

For above 1GHz : Distance Factor: 20 x log (3.75 m/3.0 m) = 1.94 dB
*Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                Test report No.      : 12496758H-A-R1
                                                                                                Page                 : 14 of 20
                                                                                                Issued date          : November 1, 2018
                                                                                                FCC ID               : HYQ12BFZ


                                                                Radiated Spurious Emission
                                                                  (Plot data, Worst case)

                                      Report No.               12496758H
                                      Test place               Ise EMC Lab.
                                      Semi Anechoic Chamber    No.2
                                      Date                     September 20, 2018
                                      Temperature / Humidity   23 deg. C / 63 % RH
                                      Engineer                 Akihiko Maeda
                                      Mode                     Transmitting mode, 433.92 MHz




                                                                            Horizontal
                                 90

                                 80

                                 70
       Field strength [dBuV/m]




                                 60

                                 50

                                 40

                                 30

                                 20

                                 10
                                      10                              100                                 1000
                                                                              Frequency [MHz]

                                            QP         Peak       Average          QP Limit       Peak Limit       Average Limit




                                                                             Vertical
                                 90

                                 80

                                 70
       Field strength [dBuV/m]




                                 60

                                 50

                                 40

                                 30

                                 20

                                 10
                                      10                              100                                 1000
                                                                              Frequency [MHz]

                                            QP         Peak       Average          QP Limit       Peak Limit       Average Limit


                                 *These plots data contains sufficient number to show the trend of characteristic features for EUT.



UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                              Test report No.       : 12496758H-A-R1
                                                                              Page                  : 15 of 20
                                                                              Issued date           : November 1, 2018
                                                                              FCC ID                : HYQ12BFZ


                                     -20dB and 99% Occupied Bandwidth

            Report No.                    12496758H
            Test place                    Ise EMC Lab.
            Semi Anechoic Chamber         No.2
            Date                          September 20, 2018
            Temperature / Humidity        23 deg. C / 63 % RH
            Engineer                      Akihiko Maeda
            Mode                          Transmitting mode, 433.92 MHz

               Bandwidth Limit : Fundamental Frequency      433.92 MHz x 0.25% =         1084.80   kHz
                 * The above limit was calculated from more stringent nominal frequency.

                   -20dB Bandwidth             Bandwidth Limit           Result
                        [kHz]                      [kHz]
                       20.708                     1084.80                 Pass

               99% Occupied Bandwidth          Bandwidth Limit           Result
                       [kHz]                       [kHz]
                     195.1395                     1084.80                 Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                   Test report No.        : 12496758H-A-R1
                                                                                   Page                   : 16 of 20
                                                                                   Issued date            : November 1, 2018
                                                                                   FCC ID                 : HYQ12BFZ


                                                          Duty Cycle
             Report No.                     12496758H
             Test place                     Ise EMC Lab.
             Semi Anechoic Chamber          No.2
             Date                           September 20, 2018
             Temperature / Humidity         23 deg. C / 63 % RH
             Engineer                       Akihiko Maeda
             Mode                           Transmitting mode, 433.92 MHz


   Pulse   ON time(One pulse)             Pulse count (Sweep time : 10mS)              Pulse count     ON time(in 50ms)
   type          [ms]                1         2         3          4          5      sum (in 50ms)          [ms]
     A             0.713            4          3          1         4         5            17               12.121
     B             0.364            7          9         13         7         6            42               15.288
                                                                            Total on time in 50mS           27.409
 The train of pulses was exceeding 100msec, and that sampled 100msec was the worst case against the pulse train.


 (Total)
     ON time in 100mS *1)             Cycle                   Duty                   Duty
             [ms]                      [ms]             (On time/Cycle)               [dB]
            54.82                    100.00                  0.55                    -5.22
 *1)ON time in 100mS = Total on time in 50mS * 2
 *2)Duty = 20log10(ON time/Cycle)




                                                    Pulse Train in 100ms




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                   Test report No.     : 12496758H-A-R1
                                                                   Page                : 17 of 20
                                                                   Issued date         : November 1, 2018
                                                                   FCC ID              : HYQ12BFZ



                                                      Duty Cycle

                   Pulse count       1                                   Pulse count      2
       Type A     Type B




                   Pulse count       3                                   Pulse count      4




                   Pulse count       5




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                              Test report No.          : 12496758H-A-R1
                                                                              Page                     : 18 of 20
                                                                              Issued date              : November 1, 2018
                                                                              FCC ID                   : HYQ12BFZ


APPENDIX 2: Test instruments
Test Instruments
Test    LIMS     Description         Manufacturer        Model           Serial             Last             Calibration    Cal
item    ID                                                                                  Calibration      Due Date       Int
                                                                                            Date
RE      142006   AC2_Semi            TDK                 Semi Anechoic   DA-06902           4/2/2018         4/30/2019      12
                 Anechoic                                Chamber 3m
                 Chamber(SVSWR)
RE      141152   EMI measurement     TSJ                 TEPTO-DV        -                  -                -              -
                 program
RE      141556   Thermo-Hygrometer   CUSTOM              CTH-201         0003               12/21/2017       12/31/2018     12
RE      141542   Digital Tester      Fluke Corporation   FLUKE 26-3      78030611           8/21/2018        8/31/2019      12
RE      142228   Measure             KOMELON             KMC-36          -                  -                -              -
RE      141942   Test Receiver       Rohde & Schwarz     ESCI            100300             8/8/2018         8/31/2019      12
RE      141427   Biconical Antenna   Schwarzbeck         VHA9103B        8031               5/31/2018        5/31/2019      12
RE      141265   Logperiodic         Schwarzbeck         VUSLP9111B      911B-190           5/31/2018        5/31/2019      12
                 Antenna
                 (200-1000MHz)
RE      141317   Coaxial Cable       Fujikura/Agilent    -               -                  2/23/2018        2/28/2019      12
RE      141578   Pre Amplifier       AGILENT             8447D           2944A10845         9/19/2018        9/30/2019      12
RE      141512   Horn Antenna        Schwarzbeck         BBHA9120D       254                6/6/2018         6/30/2019      12
                 1-18GHz
RE      141392   Microwave Cable     Junkosha            MWX221          1604S253(1 m) /    8/8/2018         8/31/2019      12
                                                                         1608S087(5 m)
RE      141297   High Pass           TOKYO KEIKI         TF219CD1        1001               1/18/2018        1/31/2019      12
                 Filter(1.1-10GHz)
RE      141579   Pre Amplifier       AGILENT             8449B           3008A02142         1/23/2018        1/31/2019      12
RE      141203   Attenuator(6dB)     Weinschel Corp      2               BK7970             11/14/2017       11/30/2018     12
RE      142004   AC2_Semi            TDK                 Semi Anechoic   DA-06902           6/29/2018        6/30/2020      24
                 Anechoic                                Chamber 3m
                 Chamber(NSA)
RE      142645   Loop Antenna        UL Japan            -               -                  -                -              -

*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that
Calibration is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means
of an unbroken chains of calibrations.

Test item:
       RE: Radiated emission, 99 % Occupied Bandwidth, -20 dB bandwidth, Automatically deactivate and Duty cycle tests




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-04-02 06:59:06
Document Modified: 2019-04-02 06:59:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC