Revised Test Report

FCC ID: HYQ12BBT

Test Report

Download: PDF
FCCID_244469

                                                                                                         Page: 1 of 16

                              EMI TEST REPORT
                             Test Report No. : 22HE0022—HO—1

                     Applicant                         :        DENSO CORPORATION

                     Type of Equipment                 :        Keyless Entry System (Transmitter)

                     Model No.                         :        12BBT

                     Test standard                     :        FCC Part 15 Subpart C Section 15.231

                     FCCID                             :        HYQ12BBT

                     Test Result                       :        Complied

      1. This test report shall not be reproduced in full or partial, without the written approval of
         A—PEX International Co., Ltd.

      2. The results in this report apply only to the sample tested.

      3. This equipmentis in compliance with above regulation. We hereby certify that the data
             contain a true representation of the EMC profile.

      4. The test results in this report are traceable to the national or international standards.

      5. This test report does not constitute an endorsement by NIST/NVLAP or U.S. Government.

      Date of test             :                   April 11 and 12, 2002


      Issued date              :                   April 26, 2002


      Tested by                :      >    W
                                          <«H-imka_Ume§/ama
                                                                    i
                                              24           J i——fz——
      Approved by              :      /fi /Z%IMSWW
                                             Tetsuya Hashimoto
                                       Site Manager of Head Office EMC Division




A—PEX International Co., Ltd. EMC Head Office Division.
4383—326 Asama—cho, Ise—shi, Mic—ken 516—0021 JAPAN
Telephone: +81 596 24 8116    Facsimile: +81 596 24 8124
                                                                                          MEFOGOb(22.05.01)


                                                              Test report No.: 22HE0022—HO—1
                                                              Page          :2 of 16
                                                              Issued date   : April 26, 2002
                                                              FCC IP        :HYQIZBBT




                                                   CONTENTS


PAGE


SECTION 1:        Client information

SECTION 2:        Equipment under test (E.U.T.)

SECTION 3:        Test specification, procedures & results

SECTION 4:        Operation of E.U.T. during testing

SECTION 5:        Radiated emission



APPENDIX 1:         Photographs of test setup

APPENDIX 2:          Test instruments

APPENDIX 3:         Data of EMI test




A—PEX International Co., Ltd. EMC Head Office Division.
4383—326 Asama—cho, Ise—shi, Mic—ken 516—0021 JAPAN

Telephone: +81 596 24 8116   Facsimile: +81 596 24 8124


                                                                                        Test report No.: 22HE0022—HO—1
                                                                                        Page          :3 of 16
                                                                                        Issued date   : April 26, 2002
                                                                                        FCC IPD       :HYQ1ZBBT



SECTION 1:           Client information


Company name                               :        DENSO CORPORATION

Trade name                                 :        DENSO CORPORATION

Address                                    :        1—1 showa—cho, kariya—shi, Aichi—ken. 448—8661 Japan


Telephone Number                           :0       +81—566—61—2537

Facsimile Number                           :        +481—566—25—4915

Contact Person                             :        MITSUGI OHTSUKA


SECTION 2:            _Equipment under test (E.U.T.)

2.1          Identification of E.U.T.

Type of Equipment                          :        Remote Keyless Entry System (Transmitter)

Model No.                                      :    12BBT

Serial No.                                     :    002

Rating                                         :    3V DC (Lithium Battery CR2016)

Country of Manufacture                          :   JAPAN

Receipt Date of Sample                          :   April 11, 2002

Condition of EUT                                :   production prototype


2.2 Product Description


Model: 12BBT Remote Keyless Entry System (Transmitter) is mainly used for locking or unlocking the doors of the
vehicle.
They are referred to as the EUT in this report.

The specification is as following :
Carrier Frequency                               :©314.35 MHz
Modulation                                      : ASK
Other Clock Frequency                           : 1.31 MHz
Information antenna                             : Built—in Type (Fixed)
Operation Voltage                               : Lithium Battery DC 3.0V(CR2016)




A—PEX International Co., Ltd. EMC Head Office Division.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN

Telephone: +81 596 24 8116      Facsimile: +81 596 24 8124


                                                                                       Test report No.: 22HE0022—HO—1
                                                                                       Page            :4 of 16
                                                                                       Issued date     : April 26, 2002
                                                                                       FCC ID          :HYQIZBBT

SECTION 3:              Test specification, procedures & results


3.1     Test Specification


Test Specification                  FCC Part 15 Subpart C
Title                                FCC 47CFR Part15 Radio Frequency Device

                                   Subpart C Intentional Radiators

                                 Section 15.231 Periodic operation in the band 40.66 — 40.70 MHz and above 7OMHz



3.2     Procedures and results

             Item              Test Procedure           Specification         Deviation|      Worst margin          Result

Automatically Deactivate       ANSI C63.4:2000        Section 15.231(a)(1)       N/A                 —             Complied


Electric
   ectric Field
           Peld Strength
                 SenE O° of    ANSI C63.4:2000|       Section 15.231(b)                    $s
Fundamental Emission
                                                                                 N/A       [314.33MHz
                                                                                           Horizontal
                                                                                                                   Complied
        h:                                            Section 15.205                       7.70B
}Sfl“‘.“c F}‘;ld. Strength Of   angr £63,4:2000|       Section 15.209             N/A       |2514.64MHz             Complied
 purious     Emission                                 Section 15.231(b)                    Horizontal/Vertical


—20dB Bandwidth                ANSI C63.4:2000        Section 15.231(c)          N/A                 —             Complied




 3.3    Additions to standards
         No addition, deviation or exclusion has been made from standards.


 3.4    Confirmation
 A—PEX INTERNATIONAL hereby confirms that E.U.T. , in the configuration tested, complies with the
 specifications FCC Part15 SubpartC Section 15.231.




 3.5         Uncertainty

 Radiated Emission Test
 The measurement uncertainty (with a 95% confidence level)       for this test using Biconical antenna is £4.4dB.
 The measurement uncertainty (with a 95% confidence level)       for this test using Logperiodic antenna is +5.00B.
 The measurement uncertainty (with a 95% confidence level)       for this test using Horn antenna is +5.5dB.
 The data listed in this test report may exceed the test limit   because it does not have enough margin.
 El The data listed in this test report has enough margin.




 A—PEX International Co., Ltd. EMC Head Office Division.
 4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN

 Telephone: +81 596 24 8116      Facsimile: +81 596 24 $124


                                                                                    Test report No.: 22HE0022—HO—1
                                                                                    Page          15 of 16
                                                                                    Issued date   : April 26, 2002
                                                                                    FCC ID        :HYQL1ZBBT




3.6    Test location

A—PEX International Co., Ltd. EMC Head Office Division. No.1 semi Anechoic Chamber, 19.2 x 11.2 x 7.7 m
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN
Telephone: +81 596 24 8116      Facsimile: +81 596 24 8124
This site has been fully described in a report submitted to FCC office, and listed on February, 2002 (Registration
number: 313583).
*NVLAP Lab. code: 200572—0



3.7       Test Setup, Data of EMI & Test instruments,

Refer to Appendix 1 to 3.




A—PEX International Co., Ltd. EMC Head Office Division.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN

Telephone: +81 596 24 8116    Facsimile: +81 596 24 8124


                                                                                    Test report No.: 22HE0022—HO—1
                                                                                    Page            : 6 of 16
                                                                                    Issued date      : April 26, 2002
                                                                                    FCC ID           :HYQLZBBT



SECTION 4:            Operation of E.U.T. during testing



4.1       Operating Modes

The EUT exercise program used during radiated and conducted testing was designed to exercise the various system
components in a manner similar to typical use.
The operating mode/system was as follows:

          Operation mode    _: Transmitting




Justification: The system was configured in typical fashion (as a customer would normally use it) for testing.

4.2       Configuration and peripherals

Top View




          *Test data was taken under worse case conditions.

Description of EUT
 No. Item                          Model number      I Serial number   Manufacturer                   FCC ID
      A    Transmitter              12BBT            [ 002             DENSO                          HYQ12BBT




A—PEX International Co., Ltd. EMC Head Office Division.
4383—326 Asama—cho, Ise—shi, Mic—ken 516—0021 JAPAN

Telephone: +81 596 24 8116       Facsimile: +81 596 24 $124


                                                                                    Test report No.: 22HE0022—HO—1
                                                                                    Page          :7 of 16
                                                                                    Issued date   : April 26, 2002
                                                                                    FCC ID        :HYQLZBBT



SECTION 5:            Radiated emission


5.1     Operating environment
The test was carried out in a No.1 semi Anechoic Chamber, 19.2 x 11.2 x 7.7 m.

Temperature            :     See data
Humidity               :     See data



5.2     Test configuration
EUT was placed on a platform of nominal size, 1m by 1.5m, raised 80cmabove the conducting ground plane.
The EUT was set on the center of the tabletop and the rear the peripheral was aligned and flushed with rear of tabletop.
Test was made with the antenna positioned in both the horizontal
and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane
to obtain the maximum signal strength.
A drawing of the set up is shown in the photos of Appendix 1.


5.3     Test conditions
Frequency range                     :   30MHz—3200MHz
Test distance                       :   3m
EUT position                        :   Tabletop
EUT operation mode                  :   Transmitting


5.4      Test procedure
The Radiated Electric Field Strength intensity has been measured on an open test site with a ground plane and at a
distance of 3m.
Measurements were performed with a quasi—peak detector.
The measuring antenna height was varied between 1 to 4m and EUT was rotated a full revolution in order to obtain
the maximum value of the electric field intensity.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver.

                           Below 1GHz          Above 1 GHz
      Detector Type        : Quasi—Peak/Peak   :Average/Peak
      IF Bandwidth         : 120 kHz           :1 MHz

—The noise was measured at each position of all three axes X, Y and Z to compare the level, and the maximum noise
occurred at the position showed in the photograph.
—The relative measurements were performed on the fundamental and the spurious emissions with each condition of
the key folded and the key set up. The key set—up condition was worse case under both the fundamental and the
spurious emissions, we, therefore, tested while the key was set up. See the photograph.
—The reading level was reduced by 6dB for comparison to the limits as this EUT had 50% duty cycle.
See the data in Appendix 3.

5.5     Results

Summary of the test results:        Pass

Date:     April 11 and 12, 2002                          Tested by:   H. Umeyama


A—PEX International Co., Ltd. EMC Head Office Division.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN

Telephone: +81 596 24 $116         Facsimile: +81 596 24 8124


                                                                                Test report No.: 22HE0022—HO—1
                                                                                Page          :8 of 16
                                                                                Issued date   : April 26, 2002
                                                                                FCC ID        :HYQLZBBT



APPENDIX 1:         Photographs of test setup


Page 9             : Radiated emission




APPENDIX 2:         Test instruments

Page 10            : Test instruments




APPENDIX 3:         Data of EMI test

Page 11—12         : Automatically Deactivate

Page13              : Radiated emission (Electric Field Strength of Fundamental and Spurious Emission)

Page14—15           : Duty cycle Under Normal Operation

Page16              : —20dB Bandwidth




A—PEX International Co., Ltd. EMC Head Office Division.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN

Telephone: +81 596 24 8116   Facsimile: +81 596 24 8124


                                                                        Test report No.: 22HE0022—HO—1
                                                                        Page          :9 of 16
                                                                        Issued date   : April 26, 2002
                                                                        FCC ID        :HYQL2BBT



APPENDIX 1:         Photographs of test setup

                               Radiated emission(Worst case position)




A—PEX International Co., Ltd. EMC Head Office Division.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN
Telephone: +81 596 24 8116   Facsimile: +81 596 24 8124


                                                                                                             Page             1 O




Test Report No :22HE00022—HO—1
o
         APPENDIX 2
          Test Instruments


EMI test equipment

   Gontral No:            Instrument                   Manufacturer      Madel No       Test tem         Callbration Date *
                                                                                                          Interval{month)
    MAT—06        Attenuator(6dB)            Weinschel Gorp           2                RE               2001/12/27 * 12
    MBA—01        Biconical Antenna          Schwarebeck              5BA9106          RE               2001/12/01 * 12
    MGC—01        Coaxial Cable              Suhner/storm/Agilent     421—014—10m.4    |RE              2001/12/27 * 12
                                                                      21—014—16m,42
                                                                      1—014~7.5m,SF
                                                                      MBGPE—1 5om,87
                                                                      65C,SFM141—15
                                                                      cm,SFM141—156
                                                                      m,87650,SFM14
                                                                      1—100m,87650.4
                                                                      21—010—Im
    MAEC—O1       Anechoic Chamber           TDK                      Semi Anechioc    [RE              2001/12/29 * 12
                                                                      Chamber 10m
    MLA—01        Logperiodic Antenna        Schwarzbeck              USLP9143         RE               2001/12/01 * 12
    MTR—01        EMI TEST RECEIVER          Rohde & Schwarz          ESI40            RE               2001/11/13 * 12
    MPA—02        Pre Amplifier              Agilent                  87405A           RE               2001/12/27 * 12
                  EMI TEST RECEIVER          Rohde & Schwarz          ESI40
                  Anechoic Chamber           TOK                      Semi Anechioc
                                                                      Chamber 10m




All equipment is calibrated with traceable calibrations. Each calibration is traceable to the national or
international standards.
CE: Conducted emission,
RE: Radiated emission,
H/F: Harmonics and voltage fluctuation
RFE: RFI Power test,
AT: Antenna terminal disturbance voltage


EMS test equipment

   Control.No..       O           iment ..   :                           Model No            sst ltem




All equipment is calibrated with traceable calibrations. Each calibration is traceable to the national or
international standards.
ESD: Electrostatic discharge,
RS: Radiated RF electromagnetic field,
EFT/B: Electrical fast transient burst,
SG: Surge,
CS: Radio—frequency conducted disturbances,
MF: Power frequency magnetic field,
Dip: Voltage dips and short interruptions




A—PEX INTERNATIONAL CO., LTD.


                                                                                                              11
                              DATA OF AUTOMATICALLY DEACTIVATE
                                                         A-PEX INTERNATIONAL CO., LTD.
                                                         EMC HEAD OFFICE DIVISION No.1 SEMI ANECHOIC CHAMBER

COMPANY        : DENSO CORPORATION                       REPORT NO         : 22HE0022-HO
EQUIPMENT      : Keyless Entry System (Transmitter)      REGULATION        : Fcc Part15 Subpart C 231(a)(1)
MODEL           : 12BBT                                  TEST DISTANCE    : 3m
S/N             : 006                                    DATE              : 04/12/2002
FCC ID           :-                                      Temperature     : 22℃
POWER          : DC3.0V                                  Humidity         : 39%
Mode           : Transmitting




                                                         ENGINEER   : Hiroka Umeyama



Time of Transmitting         Limit              Result

       [sec]                  [sec]
       0.44                   5.00               Pass


                           12

AUTOMATICALLY DEACTIVATE


                                                                                                                                        13
                                          DATA OF RADIATED EMISSIONS
                                                                 A-PEX INTERNATIONAL CO., LTD.
                                                                 EMC HEAD OFFICE DIVISION No.1 SEMI ANECHOIC CHAMBER

COMPANY         : DENSO CORPORATION                              REPORT NO              : 22HE0022-HO
EQUIPMENT       : Keyless Entry System (Transmitter)             REGULATION            : Fcc Part15 Subpart C 231(b) / 205
MODEL            : 12BBT                                         TEST DISTANCE        : 3m
S/N              : 002                                           DATE                  : 04/11/2002
FCC ID            :-                                             Temperature          : 21℃
POWER            : DC3.0V                                        Humidity              : 37%
Mode            : Transmitting



                                                                 ENGINEER        : Hiroka Umeyama

No.    FREQ      T/R READING : PK           ANT         AMP         LOSS       Duty             RESULT               Limit       MARGIN
                  HOR      VER              Factor      GAIN                   Factor       HOR      VER                     HOR      VER
      [MHz]     [dBuV/m]                     [dB]       [dB]        [dB]        [dB]      [dBuV/m]              [dBuV/m]     [dB]     [dB]
 1    314.33      74.5     69.9             14.8        23.8        9.8         -6.0        69.3     64.7         75.6        6.3     10.9

No.    FREQ      T/R READING : QP           ANT         AMP         LOSS       Duty             RESULT               Limit      MARGIN
                  HOR      VER              Factor      GAIN                   Factor       HOR      VER                     HOR     VER
      [MHz]     [dBuV/m]                     [dB]       [dB]        [dB]        [dB]      [dBuV/m]              [dBuV/m]     [dB]    [dB]
 2    628.66      27.3     29.5             19.4        24.0        11.5        0.0         34.2     36.4         55.6       21.4    19.2
 3    942.99      25.0     24.5             22.4        24.0        12.8        0.0         36.2     35.7         55.6       19.4    19.9

No.    FREQ      T/R READING : PK           ANT         AMP         LOSS       Duty            RESULT                Limit      MARGIN
                  HOR      VER              Factor      GAIN                   Factor       HOR     VER                      HOR     VER
      [MHz]     [dBuV/m]                     [dB]       [dB]        [dB]        [dB]      [dBuV/m]              [dBuV/m]     [dB]    [dB]
4     1257.32      37.1         37.9        25.2        23.8        8.1         0.0         46.6        47.4         75.6    29.0     28.2
5     1571.65      41.4         40.7        25.7        23.9        9.0         0.0         52.2        51.5         74.0    21.8     22.5
6     1885.98      40.1         40.8        26.3        24.2        10.0        0.0         52.2        52.9         75.6    23.4     22.7
7     2200.31      41.5         43.2        27.0        24.8        10.8        0.0         54.5        56.2         74.0    19.5     17.8
8     2514.64      43.8         43.8        27.7        25.4        11.5        0.0         57.6        57.6         75.6    18.0     18.0
9     2828.97      39.8         40.0        28.1        25.4        12.4        0.0         54.9        55.1         74.0    19.1     18.9
10    3143.30      38.8         38.1        28.4        25.2        12.9        0.0         54.9        54.2         75.6    20.7     21.4

No.    FREQ      T/R READING : AV           ANT         AMP         LOSS       Duty             RESULT               Limit       MARGIN
                  HOR       VER             Factor      GAIN                   Factor       HOR      VER                     HOR      VER
       [MHz]    [dBuV/m]                     [dB]       [dB]        [dB]        [dB]      [dBuV/m]              [dBuV/m]     [dB]     [dB]
4     1257.32     24.1      25.7            25.2        23.8        8.1         0.0         33.6     35.2         55.6       22.0     20.4
5     1571.65     30.1      29.5            25.7        23.9        9.0         0.0         40.9     40.3         54.0       13.1     13.7
6     1885.98     28.5      29.8            26.3        24.2        10.0        0.0         40.6     41.9         55.6       15.0     13.7
7     2200.31     30.9      32.0            27.0        24.8        10.8        0.0         43.9     45.0         54.0       10.1      9.0
8     2514.64     34.1      34.1            27.7        25.4        11.5        0.0         47.9     47.9         55.6        7.7      7.7
9     2828.97     26.8      26.5            28.1        25.4        12.4        0.0         41.9     41.6         54.0       12.1     12.4
10    3143.30     25.7      25.5            28.4        25.2        12.9        0.0         41.8     41.6         55.6       13.8     14.0

REMARKS
ANTENNA TYPE:30-300MHz Biconical / 300-1000MHz Logperiodic / 1-3.2GHz Horn
CALCULATION RESULT=Reading + ANT Factor - Amp Gain + LOSS (Cable+ ATTEN.)+Duty factor
*Except for the above table : All other spurious emissions were less than 20dB for the limit.
*EUT was placed in X axis when the measurement antenna was positioned horizontally.
*EUT was placed in Y axis when the measurement antenna was positioned vertically.
*The noise was measured at each position of all three axes X, Y and Z to compare the level, and the maximum noise.

Duty cycle Factor Measurement
The duty cycle factor = 20log( Δ1: 80 + Δ2 : 1433 + Δ3 : 681 + Δ4 : 311 / 5000) = -6.00


                                    14

DUTY CYCLE UNDER NORMAL OPERATION


Duty cycle :


Data type :         ON

                                              Tw 1 —P

                   OFF
                                            4————— Tw2 ————p
Frame Format :
      Header                   Parity bit                 Function bit   ID and Counter bit
       (Sbit)                    (8Sbit)                    (16bit)           (64bit)

                      |                       88bit
Data Time :

                                   Twl/Tw2

Header                             0.78msec/ 1.56msec

Parity bit                         Data"0"     0.78msec/ 1.56msec
Function bit                                          j                                  x
ID and Counter bit                 Data"1"     1.56msec/ 1.56msec or Omsec/ 1.56msec


* Data"1"
   Pattern A                                                 Pattern B

     ON                                                        ON



    OFF                            ——————         or          OFF
                     1.56msec                                             1.56msec

                      (1bit)                                               (1bit)


Calculation of the duty factor
  header=0.78msec/ 1.56msec X 8Sbit = 0.5

  Duty of Parity bit, Function bit, ID and Counter bit are as follows;

       In case of all data="0"

              0. 7Smsec/ 1.56msec X 88bit = 0.5

       In case of all data="1"

             Ppattern A and Pattern B are appeared alternately.

              (1.56msec/ 1.56msec) * (88bit/2)+(Omsec," 1.56msec) X (88bit/2) = 0.5

 Duty Factor = 20l0g 0.5= — 6.0


                                                                                                           16
                                             DATA OF -20dB-Bandwidth
                                                         A-PEX INTERNATIONAL CO., LTD.
                                                         EMC HEAD OFFICE DIVISION No.1 SEMI ANECHOIC CHAMBER

COMPANY        : DENSO CORPORATION                       REPORT NO         : 22HE0022-HO
EQUIPMENT      : Keyless Entry System (Transmitter)      REGULATION        : Fcc Part15 Subpart C 231(c)
MODEL           : 12BBT                                  TEST DISTANCE    : 3m
S/N             : 002                                    DATE              : 04/11/2002
FCC ID           :-                                      Temperature     : 21℃
POWER          : DC3.0V                                  Humidity         : 37%
Mode           : Transmitting



                                                         ENGINEER    : Hiroka Umeyama

Bandwidth Limit : Fundamental Frequency 314.35MHz X 0.25% = 785.875kHz

  -20dB Bandwidth       Bandwidth Limit         Result

       [kHz]                 [kHz]
      225.45                785.88               Pass