Test Report 2400 Series

FCC ID: HWFBEARPAW

Test Report

Download: PDF
FCCID_119212

                                 Test Report
                                   Class II Change

                                           For

               Applicant              : Mustek Systems Inc.
               Equipment Type : Scanner
               Model                  : BearPaw 2400, BP 2400, 2400 DU
               FCC ID                 : HWFBEARPAW
               Project Name           : B12U14K




                                 Report No. : 007H038FI



FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)        QuieTek Corporation          Page: 1 of 14
NVLAP Lab. Code : 200347-0            EMC Test Laboratory          Rev.1


                                  Test Report Certification

                                 QuieTek Corporation
                                  No.75-1, Wang-Yeh Valley, Yung-Hsing, Chiung-Lin,
                                           Hsin-Chu County, Taiwan, R.O.C.
                                    Tel : 886-3-592-8858, Fax: 886-3-592-8859
                                           E-Mail : quietek@ms24.hinet.net
                          Accredited by NIST(NVLAP), VCCI, BSMI, DNV, TUV


       Applicant                     : Mustek Systems Inc.

       Address                       : No. 25, R&D Road II, Science-Based Industrial Park,
                                       Hsin-Chu, Taiwan, R.O.C.

       Equipment Type                : Scanner

       Model                         : BearPaw 2400, BP 2400, 2400 DU

       FCC ID.                       : HWFBEARPAW

       Measurement Standard          : CISPR 22/1985

       Measurement Procedure : ANSI C63.4 /1992

       Operation Voltage             : 120VAC/60Hz

       Classification                : Class B

       Test Result                   : Complied

       Test Date                     : Aug.07, 2000

       Report No.                    : 007H038FI


   The Test Results relate only to the samples tested.
   The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
   This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government
   Documented by: Lisa Chen               Test Engineer: Jimmy Huang           Approved: Kevin Wang




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)                   QuieTek Corporation                                Page: 2 of 14
NVLAP Lab. Code : 200347-0                       EMC Test Laboratory                                Rev.1


                                                      TABLE OF CONTENTS
                Description                                                                                                                                                        Page
1.      GENERAL INFORMATION ........................................................................................................................................4
1.1     EUT Description................................................................................................................................................................4
1.2     Tested System Details........................................................................................................................................................5
1.3     EUT Configuration............................................................................................................................................................7
1.4     EUT Exercise Software.....................................................................................................................................................7
1.5     Test performed...................................................................................................................................................................7
1.6     Test Facility........................................................................................................................................................................8
2.      CONDUCTED EMISSION ............................................................................................................................................9
2.1     Test Equipment List...........................................................................................................................................................9
2.2     Test Setup ...........................................................................................................................................................................9
2.3     Limits..................................................................................................................................................................................9
2.4     Test Procedure..................................................................................................................................................................10
2.5     Test Results ......................................................................................................................................................................10
3.      RADIATED EMISSION...............................................................................................................................................11
3.1     Test Equipment ................................................................................................................................................................11
3.2     Test Setup .........................................................................................................................................................................11
3.3     Limits................................................................................................................................................................................12
3.4     Test Procedure..................................................................................................................................................................12
3.5     Test Results ......................................................................................................................................................................12
4.      EMI REDUCTION METHOD DURING COMPLIANCE TESTING ................................................................13

5.      ATTACHMENT.............................................................................................................................................................14

                 ATTACHMENT 1: SUMMARY OF TEST RESULTS
                 ATTACHMENT 2: EUT TEST PHOTOGRAPHS
                 ATTACHMENT 3: EUT DETAILED PHOTOGRAPHS




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)                                            QuieTek Corporation                                                                   Page: 3 of 14
NVLAP Lab. Code : 200347-0                                                EMC Test Laboratory                                                                   Rev.1


1.       General Information

1.1      EUT Description



         Applicant                        : Mustek Systems Inc.

         Address                          : No. 25, R&D Road II, Science-Based Industrial
                                            Park, Hsin-Chu, Taiwan, R.O.C.

         Equipment Type                   : Scanner

         Model                            : BearPaw 2400, BP 2400, 2400 DU

         FCC ID                           : HWFBEARPAW

         Adapter                      :    MFR:HIGH Power, M/N:HPW-1512A

                                           BSMI No:3872B620


         Remark:

                  1. This EUT is a Scanner.FCC ID: HWFBFARPAW.

                  2. The variation of model name is for different market. The circuit of each model is
                     identical.

                  3. The second type CCD of Toshiba is selected as another source. so, class II change
                     procedure is adopted.

                  4. QuieTek had verified both construction and function of the above model in typical
                     operation, then shown in the test report.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)             QuieTek Corporation                       Page: 4 of 14
NVLAP Lab. Code : 200347-0                 EMC Test Laboratory                       Rev.1


1.2      Tested System Details

         The types for all equipment, plus descriptions of all cables used in the tested system
         (including inserted cards ) are:

1.2.1    Host Personal Computer
         Model Number                   : DESK PRO 2000
         Manufacturer                   : Compaq
         Serial Number                  : N/A
         FCC ID                         : DoC
         Power Cord                     : Non-Shielded,1.8m

1.2.2    Scanner (EUT)
         Model Number                   : BearPaw 2400, BP 2400, 2400 DU
         Serial Number                  : N/A
         FCC ID                         : DoC
         Manufacturer                   : Mustek
         Adapter                        : MFR:HIGH Power, M/N:HPW-1512A
                                          BSMI No:3872B620

1.2.3    Transparency Adapter
         Model Number                   : TA5
         Serial Number                  : N/A
         FCC ID                         : DoC
         Manufacturer                   : MUSTEK

1.2.4    Monitor
         Model Number                   : KM-511
         Serial Number                  : 829H0684
         FCC ID                         : ARFKM411511
         Manufacturer                   : SAMPO
         Data Cable                     : Shielded, 1.5m, Bonded Cord 1 pc
         Power Cord                     : Non-Shielded, 1.8m

1.2.5    Keyboard
         Model Number                   : 6311-TW4C
         Serial Number                  : 916590704C91F24438
         FCC ID                         : DoC
         Manufacturer                   : ACER
         Data Cable                     : Shielded, 1.8m



FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)             QuieTek Corporation                           Page: 5 of 14
NVLAP Lab. Code : 200347-0                 EMC Test Laboratory                           Rev.1


1.2.6    Printer
         Model Number            : C2642A
         Serial Number           : MY75N1D2Y1
         FCC ID                  : B94C2642X
         Manufacturer            : HP
         Data Cable              : Shielded, 1.2m
         Power Adapter           : NMB, C2175A
                                   Cable for AC IN: Non-Shielded, 0.7m
                                   Cable for AC Out: Non-Shielded, 1.5m

1.2.7    Mouse
         Model Number            : M-S34
         Serial Number           : LZA71178588
         FCC ID                  : DZL211029
         Manufacturer            : HP
         Data Cable              : Shielded, 1.8m

1.2.8    Earphone
         Model Number            : PH136
         Serial Number           : N/A
         Manufacturer            : BSD
         Data Cable              : Shielded, 1.2m

1.2.9    Video Camera
         Model Number            : Wcam 3X
         Serial Number           : N/A
         FCC ID                  : DoC
         Manufacturer            : Mustek
         Data Cable (USB)        : Shielded, 1.5m




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)     QuieTek Corporation                    Page: 6 of 14
NVLAP Lab. Code : 200347-0         EMC Test Laboratory                    Rev.1


1.3      EUT Configuration


        Transparency
        Adapter                                       Monitor


                                                            PC                  Printer

                  EUT



                                       Earphone



                                                                     Mouse

                                                                                    Modem


                                                        Keyboard                                      CCD



1.4      EUT Exercise Software

         The EUT exercise program used during conducted testing was designed to exercise the EUT
         in a manner similar to a typical use. The exercise sequence is listed as below:
         1.4.1 Setup the EUT and simulators as shown on 1.3
         1.4.2    Turn on the power of all equipment.
         1.4.3    Boot the PC from Hard Disk .
         1.4.4    PC reads test software from disk.
         1.4.5    The EUT will start to operate and then the scanner capture the video figure into PC.
         1.4.6    PC will display “video figure” on monitor.
         1.4.7    Printer and modem will keep at standby mode during EUT operation.
         1.4.8    Repeat the above procedure 1.4.4 to 1.4.7


1.5      Test performed

         Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz
         using a receiver bandwidth of 9kHz.

         Radiated emissions were invested over the frequency range from 30MHz to 1000MHz
         using a receiver bandwidth of 120kHz. Radiated testing was performed at an antenna to EUT
         distance of 10 meters .


FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)              QuieTek Corporation                           Page: 7 of 14
NVLAP Lab. Code : 200347-0                  EMC Test Laboratory                           Rev.1


1.6      Test Facility
         Ambient conditions in the laboratory:
                    Items                 Required (IEC 68-1)              Actual

         Temperature (°C)              15-35                    20-35
         Humidity (%RH)                25-75                    50-65
         Barometric pressure (mbar) 860-1060                    950-1000


         Site Description: November 3, 1998 File on
                           Federal Communications Commission
                           FCC Engineering Laboratory
                           7435 Oakland Mills Road
                           Columbia, MD 21046
                           Reference 31040/SIT1300F2

                                 September 30, 1998 Accreditation on NVLAP
                                 NVLAP Lab Code: 200347-0

                                 February 23, 1999 Accreditation on DNV
                                 Statement No. : 413-99-LAB11

                                 December 8, 1998 Registration on VCCI
                                 Registration No. for No.2 Shielded Room C-858
                                 Registration No. for No.1 Open Area Test Site R-823
                                 Registration No. for No.2 Open Area Test Site R-835

                                 January 04, 1999 Accreditation on TUV Rheinland
                                 Certificate No.: I9865712-9901


         Name of firm       : QuieTek Corporation

         Site location      : No.75-1, Wang-Yeh Valley, Yung-Hsing Tsuen,
                                 Chiung-Lin, Hsin-Chu County, Taiwan, R.O.C.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)                 QuieTek Corporation                     Page: 8 of 14
NVLAP Lab. Code : 200347-0                     EMC Test Laboratory                     Rev.1


2.       Conducted Emission
2.1      Test Equipment List

         The following test equipment are used during the conducted emission test:
         Item Instrument                    Manufacturer Type No./Serial No                      Last Cal..      Remark
         1      Test Receiver               R&S                ESCS 30/825442/17                 May, 2000
         2      L.I.S.N.                    R&S                ESH3-Z5/825016/6                  May, 2000       EUT
         3      L.I.S.N.                    Kyoritsu           KNW-407/8-1420-3                  May, 2000       Peripherals
         4      Pulse Limiter               R&S                ESH3-Z2                           N/A
         5        N0.2 Shielded Room                                                             N/A
         Note: All equipment upon which need to calibrated are with calibration period of 1 year.

2.2      Test Setup

                                                                               Reference Plane

                         Test Receiver
                                                                                                   40cm


                      12dBuV                                                  EUT
                      ooo                                          Load
                      ooo




                                                  LISN                                           LISN


                                                                                 LISN
                                         Ground Plane

2.3      Limits

                     CISPR 22 Limits (dBuV)                                   FCC Part 15 Subpart B (dBuV)

             Frequency            Class A                Class B          Frequency              Class A        Class B

               MHz             QP          AV           QP    AV            MHz             uV       dBuV      uV    dBuV

             0.15 - 0.50        79          66     66-56 56-46            0.45-1.705      1000          60.0   250     48.0

              0.50-5.0          73          60          56    46          1.705-30        3000          69.5   250     48.0

              5.0 - 30          73          60          60    50

         Remarks : In the above table, the tighter limit applies at the band edges.


FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)                          QuieTek Corporation                                    Page: 9 of 14
NVLAP Lab. Code : 200347-0                              EMC Test Laboratory                                    Rev.1


2.4      Test Procedure
         The EUT and simulators are connected to the main power through a line impedance
         stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the
         measuring equipment. The peripheral devices are also connected to the main power through a
         LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please
         refers to the block diagram of the test setup and photographs.)
         Both sides of A.C. line are checked for maximum conducted interference. In order to find the
         maximum emission, the relative positions of equipment and all of the interface cables must be
         changed according to ANSI C63.4 /1992 on conducted measurement.
         The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz.


2.5      Test Results
         The conducted emission from the EUT is measured and shown in attachment 1 of test report.
         The acceptance criterion was met and the EUT passed the test.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)            QuieTek Corporation                          Page: 10 of 14
NVLAP Lab. Code : 200347-0                EMC Test Laboratory                          Rev.1


3.       Radiated Emission

3.1      Test Equipment

         The following test equipment are used during the radiated emission test:

          Test Site               Equipment           Manufacturer           Model No./Serial No.         Last Cal.

         Site # 1         X       Test Receiver     R&S                    ESCS 30 / 825442/14            May, 2000
                                  Spectrum Analyzer Advantest              R3261C / 71720140              May, 2000
                                  Pre-Amplifier     HP                     8447D/3307A01812               May, 2000

                          X       Bilog Antenna     Chase                  CBL6112B / 12452               Sep., 1999

                          X       Horn Antenna      EM                     EM6917 / 103325                May, 2000
         Site # 2         X       Test Receiver     R&S                    ESCS 30 / 825442/17            May, 2000
                                  Spectrum Analyzer Advantest              R3261C / 71720609              May, 2000
                                  Pre-Amplifier     HP                     8447D/3307A01814               May, 2000

                          X       Bilog Antenna     Chase                  CBL6112B / 2455                Sep., 1999

                          X       Horn Antenna      EM                     EM6917 / 103325                May, 2000
             Note:       1. All equipment upon which need to calibrated are with calibration period of 1 year.
                         2.. Mark “X” test instruments are used to measure the final test results.

3.2      Test Setup

                                                                             3m or 10m


                              FRP Dome
                                                                                                                   1m to 4m




                                                                                     Antenna Mast
                                                                                     Broadband or
                                                                                     Dipole Antenna
                                                                                     Antenna height can
                                                                                     be moved from 1m
                                              EUT                                    to 4m, Antenna and
                     Non-Conducted Table                                             turntable distance
                                                         80cm                        3m or 10m


                                                                Fully Soldered Metal Ground Plane           To Controller
                         Test                                                                                   To Receiver
                       Receiver




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)                      QuieTek Corporation                                    Page: 11 of 14
NVLAP Lab. Code : 200347-0                          EMC Test Laboratory                                    Rev.1


3.3      Limits

                         CISPR 22 Limits                             FCC Part 15 Subpart B

           Frequency         Class A        Class B       Frequency       Class A        Class B

                        Distance        Distance
              MHz                dBuV/m          dBuV/m                uV/m dBuV/m uV/m dBuV/m
                          (m)             (m)

            30 – 230       10      40      10     30       30 – 88      90      39     100     40.0

          230 – 1000       10      47      10     37      88 – 216      150    43.5    150     43.5

                                                          216 –960      210    46.5    200     46.0

                                                          960 - 2000    300    49.5    500     54.0

         Remark: 1. The tighter limit shall apply at the edge between two frequency bands.
                     2. Distance refers to the distance in meters between the measuring instrument
                        antenna and the closed point of any part of the device or system.
                     3. RF Line Voltage (dBuV/m) = 20 log RF Line Voltage (uV/m)

3.4      Test Procedure
         The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The
         turn table can rotate 360 degrees to determine the position of the maximum emission level.
         The EUT was positioned such that the distance from antenna to the EUT was 10 meters .
         The antenna can move up and down between 1 meter and 4 meters to find out the maximum
         emission level.
         Both horizontal and vertical polarization of the antenna are set on measurement. In order to
         find the maximum emission, all of the interface cables must be manipulated according to
         ANSI C63.4 /1992 on radiated measurement.
         The bandwidth below 1GHz setting on the field strength meter (R&S Test Receiver ESCS 30 )
          is 120 kHz.


3.5      Test Results
         The radiated emission from the EUT is measured and shown in attachment 1 of test report.
         The acceptance criterion was met and the EUT passed the test.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)              QuieTek Corporation                          Page: 12 of 14
NVLAP Lab. Code : 200347-0                  EMC Test Laboratory                          Rev.1


4.       EMI Reduction Method During Compliance Testing


         No modification was made during testing.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)           QuieTek Corporation   Page: 13 of 14
NVLAP Lab. Code : 200347-0               EMC Test Laboratory   Rev.1


5.       Attachment

         Attachment 1: Summary of Test Results           Number of Pages: 9

         Attachment 2: EUT Test photographs              Number of Pages: 4

         Attachment 3: EUT Detailed photographs          Number of Pages: 3




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)          QuieTek Corporation                   Page: 14 of 14
NVLAP Lab. Code : 200347-0              EMC Test Laboratory                   Rev.1


Attachment 1 : Summary of Test Results
         The test results in the emission were performed according to the requirements of
         measurement standard and process. QuieTek Corporation is assumed full responsibility for the
         accuracy and completeness of these measurements. The test data of the emission are listed as
         the attached data.
         All the tests were carried out with the EUT in normal operation, which was defined as:
         (1) Mode 1: NEC CCD
         (2) Mode 2: Toshiba CCD



         The EUT passed all the tests.


         The uncertainty is calculated in accordance with NAMAS NIS 81, The total uncertainty for
         this test is as follows:
         Ø Emission Test
             • Uncertainty in the Conducted Emission Test:                  < ± 2.0 dB
             • Uncertainty in the field strength measured:                  < ± 4.0 dB




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)            QuieTek Corporation                       Page: 1 of 9
NVLAP Lab. Code : 200347-0                EMC Test Laboratory                       Rev.1


                                   CONDUCTED EMISSION DATA
  Date of Test :                  Aug.07, 2000           EUT           :         Scanner
  Test Mode           :                 Mode 1           Detect Mode   :   Quasi-Peak & Average


  Frequency   Cable    LISN    Reading Level    Measurement Level   Limits
               Loss Factor         Line1              Line1
        MHz      dB      dB        dBuV               dBuV           dBuV
  ========================================================================
     *0.176    0.01    0.10       50.12              50.23          64.65
      0.354    0.05    0.10       34.32              34.47          58.87
      0.449    0.06    0.10       37.10              37.26          56.90
      0.715    0.08    0.10       35.67              35.85          56.00
      2.994    0.17    0.15       34.58              34.90          56.00
      5.717    0.21    0.18       33.51              33.90          60.00


Average:
      0.177          0.01        0.10            42.50             42.61           54.63
      0.354          0.05        0.10            30.10             30.25           48.87
      0.449          0.06        0.10            30.40             30.56           46.89
      0.715          0.08        0.10            25.50             25.68           46.00
      2.994          0.17        0.15            21.80             22.12           46.00
      5.717          0.21        0.18            31.10             31.49           50.00



         Remarks :
                  1. “ * ” means that this data is the worst emission level.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)               QuieTek Corporation                    Page: 2 of 9
NVLAP Lab. Code : 200347-0                   EMC Test Laboratory                    Rev.1


                                   CONDUCTED EMISSION DATA
  Date of Test :                  Aug.07, 2000           EUT           :         Scanner
  Test Mode           :                 Mode 1           Detect Mode   :   Quasi-Peak & Average


  Frequency   Cable    LISN    Reading Level    Measurement Level   Limits
               Loss Factor         Line2              Line2
        MHz      dB      dB        dBuV               dBuV           dBuV
  ========================================================================
     *0.179    0.01    0.10       53.63              53.74          64.54
      0.271    0.03    0.10       41.48              41.61          61.08
      0.450    0.06    0.10       39.27              39.43          56.88
      0.810    0.09    0.10       34.04              34.23          56.00
      0.810    0.09    0.10       34.02              34.21          56.00
      2.857    0.17    0.15       34.61              34.92          56.00
      2.857    0.17    0.15       34.47              34.78          56.00
      5.600    0.21    0.17       33.42              33.81          60.00


Average:
      0.179          0.01        0.10            49.90             50.01           54.53
      0.271          0.03        0.10            35.50             35.63           51.09
      0.450          0.06        0.10            34.53             34.69           46.88
      0.810          0.09        0.10            25.60             25.79           46.00
      2.857          0.17        0.15            19.30             19.61           46.00
      5.600          0.21        0.17            29.30             29.69           50.00



         Remarks :
                  1. “ * ” means that this data is the worst emission level.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)               QuieTek Corporation                    Page: 3 of 9
NVLAP Lab. Code : 200347-0                   EMC Test Laboratory                    Rev.1


                                   CONDUCTED EMISSION DATA
  Date of Test :                  Aug.07, 2000           EUT           :         Scanner
  Test Mode           :                 Mode 2           Detect Mode   :   Quasi-Peak & Average


  Frequency   Cable    LISN    Reading Level    Measurement Level   Limits
               Loss Factor         Line1              Line1
        MHz      dB      dB        dBuV               dBuV           dBuV
  ========================================================================
     *0.187    0.01    0.10       52.50              52.61          64.15
      0.281    0.03    0.10       45.08              45.21          60.79
      0.472    0.06    0.10       39.39              39.55          56.48
      0.472    0.06    0.10       39.55              39.71          56.48
      0.849    0.09    0.10       38.28              38.47          56.00
      1.132    0.11    0.11       36.85              37.06          56.00
      5.185    0.20    0.17       36.76              37.14          60.00


Average:
      0.187          0.01        0.10            44.30             44.41           54.17
      0.281          0.03        0.10            31.50             31.63           50.79
      0.472          0.06        0.10            33.80             33.96           46.48
      0.849          0.09        0.10            28.50             28.69           46.00
      1.131          0.11        0.11            25.30             25.51           46.00
      5.185          0.20        0.17            34.60             34.98           50.00



         Remarks :
                  1. “ * ” means that this data is the worst emission level.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)               QuieTek Corporation                    Page: 4 of 9
NVLAP Lab. Code : 200347-0                   EMC Test Laboratory                    Rev.1


                                   CONDUCTED EMISSION DATA
  Date of Test :                  Aug.07, 2000           EUT           :         Scanner
  Test Mode           :                 Mode 2           Detect Mode   :   Quasi-Peak & Average


  Frequency   Cable    LISN    Reading Level    Measurement Level   Limits
               Loss Factor         Line2              Line2
        MHz      dB      dB        dBuV               dBuV           dBuV
  ========================================================================
     *0.188    0.01    0.10       54.11              54.22          64.10
      0.283    0.03    0.10       41.55              41.68          60.73
      0.283    0.03    0.10       41.49              41.62          60.73
      0.474    0.06    0.10       39.43              39.59          56.44
      0.565    0.07    0.10       36.29              36.46          56.00
      1.230    0.11    0.11       33.90              34.12          56.00
      1.230    0.11    0.11       33.82              34.04          56.00
      5.223    0.20    0.17       36.75              37.13          60.00


Average:
      0.189          0.01        0.10            49.60             49.71           54.08
      0.283          0.03        0.10            36.20             36.33           50.73
      0.474          0.06        0.10            34.50             34.66           46.44
      0.565          0.07        0.10            30.30             30.47           46.00
      1.230          0.11        0.11            23.10             23.32           46.00
      5.333          0.21        0.17            34.00             34.38           50.00



         Remarks :
                  1. “ * ” means that this data is the worst emission level.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)               QuieTek Corporation                    Page: 5 of 9
NVLAP Lab. Code : 200347-0                   EMC Test Laboratory                    Rev.1


                                     RADIATED EMISSION DATA
  Date of Test :                 Aug.07, 2000     EUT          :        Scanner
  Test Mode           :             Mode 1         Test Site   :   No.2 Open Test Site


      Freq. Cable Probe PreAMP Reading Measurement Margin Limit Ant Turn
             Loss Factor          Level Horizontal
       MHz     dB   dB/m     dB    dBuV    dBuV/m      dB dBuV/m cm deg
  ========================================================================
  *192.000   2.71   9.00   0.00 15.34       27.05    2.95 30.00 398 104
   213.000   2.92   9.03   0.00   13.42     25.37    4.63 30.00 398 132
   219.003   2.97   9.38   0.00   12.64     25.00    5.00 30.00 398 132
   233.137   3.11 10.71    0.00   11.84     25.66   11.34 37.00 398    10
   276.000   3.52 12.91    0.00   14.00     30.44    6.56 37.00 300    55
   336.000   3.94 13.76    0.00   13.90     31.60    5.40 37.00 300    81
   363.753   4.09 14.66    0.00    7.72     26.47   10.53 37.00 300 169
   384.000   4.19 15.11    0.00   12.49     31.79    5.21 37.00 300 185
   532.885   4.96 18.11    0.00    5.80     28.86    8.14 37.00 195 129



   Remarks:
                1.All Readings below 1GHz are Quasi-Peak, above are average value.
                2.“ * ”, means this data is the worst emission level.
                3.Emission Level = Reading Level + Antenna Factor + Cable loss




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)           QuieTek Corporation               Page: 6 of 9
NVLAP Lab. Code : 200347-0               EMC Test Laboratory               Rev.1


                                     RADIATED EMISSION DATA
  Date of Test :                 Aug.07, 2000     EUT          :        Scanner
  Test Mode           :             Mode 1        Test Site    :   No.2 Open Test Site


      Freq. Cable Probe PreAMP Reading Measurement Margin Limit Ant Turn
             Loss Factor          Level Vertical
       MHz     dB   dB/m     dB    dBuV    dBuV/m      dB dBuV/m cm deg
  ========================================================================
    45.580   1.30   9.96   0.00    9.41     20.67    9.33 30.00 100 166
    58.750   1.43   6.30   0.00   16.76     24.49    5.51 30.00 100    66
    73.420   1.57   6.63   0.00   12.55     20.75    9.25 30.00 100 111
  *111.679   1.93 11.72    0.00 11.40       25.05    4.95 30.00 100    17
   192.000   2.71   8.88   0.00    9.04     20.63    9.37 30.00 100    35
   216.000   2.94   9.13   0.00   10.98     23.05    6.95 30.00 100    40
   276.000   3.52 12.66    0.00   12.20     28.38    8.62 37.00 100     3
   336.000   3.94 14.63    0.00   11.80     30.37    6.63 37.00 100 181



   Remarks:
                1.All Readings below 1GHz are Quasi-Peak, above are average value.
                2.“ * ”, means this data is the worst emission level.
                3.Emission Level = Reading Level + Antenna Factor + Cable loss.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)           QuieTek Corporation               Page: 7 of 9
NVLAP Lab. Code : 200347-0               EMC Test Laboratory               Rev.1


                                     RADIATED EMISSION DATA
  Date of Test :                 Aug.07, 2000     EUT          :        Scanner
  Test Mode           :             Mode 2         Test Site   :   No.2 Open Test Site


      Freq. Cable Probe PreAMP Reading Measurement Margin Limit Ant Turn
             Loss Factor          Level Horizontal
       MHz     dB   dB/m     dB    dBuV    dBuV/m      dB dBuV/m cm deg
  ========================================================================
    57.745   1.42   5.52   0.00    4.97     11.91   18.09 30.00 398    60
   216.000   2.94   9.11   0.00   10.00     22.05    7.95 30.00 398 155
   308.997   3.80 13.55    0.00   11.50     28.85    8.15 37.00 300    73
  *336.000   3.94 13.76    0.00 15.90       33.60    3.40 37.00 310    73
   357.000   4.05 14.45    0.00   13.50     32.00    5.00 37.00 300    73
   364.000   4.09 14.66    0.00    5.50     24.25   12.75 37.00 283 195
   384.000   4.19 15.11    0.00   12.50     31.80    5.20 37.00 257 114



   Remarks:
                1.All Readings below 1GHz are Quasi-Peak, above are average value.
                2.“ * ”, means this data is the worst emission level.
                3.Emission Level = Reading Level + Antenna Factor + Cable loss




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)           QuieTek Corporation               Page: 8 of 9
NVLAP Lab. Code : 200347-0               EMC Test Laboratory               Rev.1


                                     RADIATED EMISSION DATA
  Date of Test :                 Aug.07, 2000     EUT          :        Scanner
  Test Mode           :             Mode 2        Test Site    :   No.2 Open Test Site


      Freq. Cable Probe PreAMP Reading Measurement Margin Limit Ant Turn
             Loss Factor          Level Vertical
       MHz     dB   dB/m     dB    dBuV    dBuV/m      dB dBuV/m cm deg
  ========================================================================
    57.748   1.42   6.40   0.00    4.06     11.88   18.12 30.00 99     90
    70.000   1.53   5.38   0.00    8.88     15.80   14.20 30.00 99     87
    78.000   1.61   6.93   0.00    7.90     16.44   13.56 30.00 99 202
   120.000   2.02 11.56    0.00    1.49     15.07   14.93 30.00 99 202
   192.000   2.71   8.88   0.00    7.87     19.46   10.54 30.00 99 202
   216.000   2.94   9.13   0.00    8.20     20.27    9.73 30.00 100 187
   233.140   3.11 10.51    0.00    9.18     22.80   14.20 37.00 99     32
   324.000   3.88 14.29    0.00    5.90     24.07   12.93 37.00 100 179
  *479.247   4.69 17.30    0.00    8.60     30.59    6.41 37.00 100 190



   Remarks:
                1.All Readings below 1GHz are Quasi-Peak, above are average value.
                2.“ * ”, means this data is the worst emission level.
                3.Emission Level = Reading Level + Antenna Factor + Cable loss.




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)           QuieTek Corporation               Page: 9 of 9
NVLAP Lab. Code : 200347-0               EMC Test Laboratory               Rev.1


Attachment 2: EUT Test Setup Photographs
                                 Front View of Conducted Test (Mode 1)




                                 Back View of Conducted Test (Mode 1)




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)            QuieTek Corporation            Page: 1 of 4
NVLAP Lab. Code : 200347-0                EMC Test Laboratory            Rev.1


                                 Front View of Conducted Test (Mode 2)




                                 Back View of Conducted Test (Mode 2)




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)            QuieTek Corporation            Page: 2 of 4
NVLAP Lab. Code : 200347-0                EMC Test Laboratory            Rev.1


                                 Front View of Radiated Test (Mode 1)




                                 Back View of Radiated Test (Mode 1)




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)           QuieTek Corporation            Page: 3 of 4
NVLAP Lab. Code : 200347-0               EMC Test Laboratory            Rev.1


                                 Front View of Radiated Test (Mode 2)




                                 Back View of Radiated Test (Mode 2)




FCC Report No.: 007H038FI
Accredited Lab. of NVLAP(NIST)           QuieTek Corporation            Page: 4 of 4
NVLAP Lab. Code : 200347-0               EMC Test Laboratory            Rev.1



Document Created: 2000-09-28 18:26:27
Document Modified: 2000-09-28 18:26:27