Test Report

FCC ID: HWFA4CIS-USB

Test Report

Download: PDF
FCCID_84126

                                 Test Report
                                  Class II Change

                                            For

            Applicant                : Mustek Systems Inc.
            Equipment Type : Scanner
            Model                    : 1200 CU PLUS, 1200 CUB, 1248 BU
            FCC ID                   : HWFA4CIS-USB




                                 Report No. : 001H016FI




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)         QuieTek Corporation          Page: 1 of 2
NVLAP Lab. Code : 200347-0             EMC Test Laboratory          Rev.1


                                 Test Report Certification

                              Q u i e Te k C o r p o r a t i o n
                                 No.75-1, Wang-Yeh Valley, Yung-Hsing, Chiung-Lin,
                                          Hsin-Chu County, Taiwan, R.O.C.
                                     Tel : 886-3-592-8858, Fax: 886-3-592-8859
                                           E-Mail : quietek@ms24.hinet.net
                        Accredited by NIST(NVLAP), VCCI, BSMI, DNV, TUV


      Applicant                      : Mustek Systems Inc.

      Address                        : No.25, R&D Road II, Science-Based Industrial Park,
                                       Hsin-Chu, Taiwan, R.O.C.
      Equipment Type                 : Scanner

      Model                          : 1200 CU PLUS, 1200 CUB, 1248 BU

      FCC ID.                        : HWFA4CIS-USB

      Measurement Standard           : CISPR 22/1994

      Measurement Procedure : ANSI C63.4 /1992

      Operation Voltage              : 120VAC/60Hz

      Classification                 : Class B

      Test Result                    : Complied

      Test Date                      : Jan.24, 2000

      Report No.                     : 001H016FI


  The Test Results relate only to the samples tested.
  The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
  This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government
  Documented by: Lisa Chen                Test Engineer: Jimmy Huang Approved: Gene Chang




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)                  QuieTek Corporation                                  Page: 2 of 2
NVLAP Lab. Code : 200347-0                      EMC Test Laboratory                                  Rev.1


                                                  TABLE OF CONTENTS
               Description                                                                                                                                          Page
1.      GENERAL INFORMATION............................................................................................................................ 4
1.1     EUT Description ................................................................................................................................................. 4
1.2     Tested System Details.......................................................................................................................................... 5
1.3     EUT Configuration.............................................................................................................................................. 8
1.4     EUT Exercise Software ....................................................................................................................................... 9
1.5     Test performed .................................................................................................................................................... 9
1.6     Test Facility ...................................................................................................................................................... 10

2.      CONDUCTED EMISSION ............................................................................................................................. 11
2.1     Test Equipment List........................................................................................................................................... 11
2.2     Test Setup ......................................................................................................................................................... 11
2.3     Limits ............................................................................................................................................................... 11
2.4     Test Procedure................................................................................................................................................... 12
2.5     Test Results....................................................................................................................................................... 12

3.      RADIATED EMISSION ................................................................................................................................. 13
3.1     Test Equipment ................................................................................................................................................. 13
3.2     Test Setup ......................................................................................................................................................... 13
3.3     Limits ............................................................................................................................................................... 14
3.4     Test Procedure................................................................................................................................................... 14
3.5     Test Results....................................................................................................................................................... 14

4.      EMI REDUCTION METHOD DURING COMPLIANCE TESTING .......................................................... 15

5.      ATTACHMENT .............................................................................................................................................. 16

                ATTACHMENT 1: SUMMARY OF TEST RESULTS
                ATTACHMENT 2: EUT TEST PHOTOGRAPHS
                ATTACHMENT 3: EUT DETAILED PHOTOGRAPHS

REFERENCE
                LABORATORY OF LICENSE




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)                                      QuieTek Corporation                                                           Page: 3 of 2
NVLAP Lab. Code : 200347-0                                          EMC Test Laboratory                                                           Rev.1


1.       General Information

1.1      EUT Description


         Applicant                       : Mustek Systems Inc.

         Address                         : No.25, R&D Road II, Science-Based Industrial
                                           Park, Hsin-Chu, Taiwan, R.O.C.

         Equipment Type                  : Scanner

         Model                           : 1200 CU PLUS, 1200 CUB, 1248 BU

         FCC ID                          : HWFA4CIS-USB

         Operation Voltage               : 120VAC/60Hz

         Data Cable(USB)                  : shielded, 1.2m, Bonded a ferrite cord




         Remark:
                     1. The EUT is a 600dpi×1200dpi USB Scanner.
                     2.The different between original device and the changing of EUT is the power
                        source.The original EUT was AC mains devices. The modification of the EUT
                        was powered from USB interface, refer to the red mart of the photograph.
                     3. QuieTek had verified the construction and function in typical operation, then
                        shown in this test report.




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)             QuieTek Corporation                        Page: 4 of 2
NVLAP Lab. Code : 200347-0                 EMC Test Laboratory                        Rev.1


1.2      Tested System Details
         The types for all equipment, plus descriptions of all cables used in the tested system
         (including inserted cards ) are:

1.2.1    Scanner(EUT)
         Model Number                  : 1200 CU PLUS, 1200 CUB, 1248 BU
         Serial Number                 : N/A
         FCC ID                        : HWFA4CIS-USB
         Manufacturer                  : Mustek
         Data Cable                    : Shielded, 1.2m, Bonded a ferrite cord

1.2.2    Host Personal Computer
         Model Number                  : P2L97
         Serial Number                 : 92M1Y00768
         FCC ID                        : DoC
         Manufacturer                  : ASUS
         Power Cord                    : Non-Shielded, 1.8m

1.2.3    Monitor
         Model Number                  : CM752ET-311
         Serial Number                 : T8D003312
         FCC ID                        : DoC
         Manufacturer                  : HITACHI
         Data Cable                    : Shielded, 1.6m
         Power Cord                    : Shielded, 1.8m

1.2.4    Keyboard
         Model Number                  : 6311-TW4C
         Serial Number                 : 916590704C91F24438
         FCC ID                        : DoC
         Manufacturer                  : ACER
         Data Cable                    : Shielded, 1.8m




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)            QuieTek Corporation                          Page: 5 of 2
NVLAP Lab. Code : 200347-0                EMC Test Laboratory                          Rev.1


1.2.5    Modem
         Model Number            : 1414
         Serial Number           : 980033032
         FCC ID                  : IFAXDM1414
         Manufacturer            : ACEEX
         Data Cable              : Shielded, 1.5m
         Power Adapter           : ACCEX, SCP41-91000A
                                 Cable Output : Shielded, 1.5m

1.2.6    Modem
         Model Number            : 1414
         Serial Number           : 980033039
         FCC ID                  : IFAXDM1414
         Manufacturer            : ACEEX
         Data Cable              : Shielded, 1.5m
         Power Adapter           : ACCEX, SCP41-91000A
                                   Cable Output : Shielded, 1.5m

1.2.7    Printer
         Model Number            : C2642A
         Serial Number           : MY75N1D2Y1
         FCC ID                  : B94C2642X
         Manufacturer            : HP
         Data Cable              : Shielded, 1.2m
         Power Adapter           : NMB, C2175A
                                 Cable for AC IN: Non-Shielded, 0.7m
                                 Cable for AC Out: Non-Shielded, 1.5m

1.2.8    Mouse
         Model Number            : M-S34
         Serial Number           : LZA82474119
         FCC ID                  : DZL211029
         Manufacturer            : Logitech
         Data Cable              : Shielded, 1.8m




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)     QuieTek Corporation                  Page: 6 of 2
NVLAP Lab. Code : 200347-0         EMC Test Laboratory                  Rev.1


1.2.9    Video Camera
         Model Number            : Wcam 3X
         Serial Number           : N/A
         FCC ID                  : DoC
         Manufacturer            : Mustek
         Data Cable (USB)        : Shielded, 1.5m

1.2.10   Speaker
         Model Number            : J-009
         Serial Number           : 97-C-019790-T
         FCC ID                  : DoC
         Manufacturer            : JS
         Data Cable              : Non-Shielded, 1.2m




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)     QuieTek Corporation   Page: 7 of 2
NVLAP Lab. Code : 200347-0         EMC Test Laboratory   Rev.1


1.3       EUT Configuration




              Monitor
            HHHHHHHH
            HHHHHHHH                                          EUT
            HHHHHHHH
            HHHHHHHH
            HHHH                                                             Printer
                                                        Scanner


                          Keyboard
                                             PC


                                                                     Modem     Modem




                                 Mouse
            Speaker

                                         Video Camera




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)                 QuieTek Corporation           Page: 8 of 2
NVLAP Lab. Code : 200347-0                     EMC Test Laboratory           Rev.1


1.4      EUT Exercise Software
         The EUT exercise program used during conducted testing was designed to exercise the EUT
         in a manner similar to a typical use. The exercise sequence is listed as below:
         1.4.1 Setup the EUT and simulators as shown on 1.3
         1.4.2 Turn on the power of all equipment.
         1.4.3 Boot the PC from Hard Disk.
         1.4.4 PC reads test software from the control BIOS of scanner and then sent to scanner.
         1.4.5 The Scanner (EUT) will start to operate and scan the video figure into PC.
         1.4.6 PC will display “video figure” on monitor.
         1.4.7 Printer and modem will keep at standby mode during Scanner operation.
         1.4.8 Repeat the above procedure 1.4.4 to 1.4.7

1.5      Test performed

         Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz
         using a receiver bandwidth of 9kHz.

         Radiated emissions were invested over the frequency range from 30MHz to 1000MHz
         using a receiver bandwidth of 120kHz. Radiated testing was performed at an antenna to EUT
         distance of 10 meters.




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)          QuieTek Corporation                        Page: 9 of 2
NVLAP Lab. Code : 200347-0              EMC Test Laboratory                        Rev.1


1.6      Test Facility
         Ambient conditions in the laboratory:
                    Items                 Required (IEC 68-1)              Actual

         Temperature (°C)              15-35                    20-35
         Humidity (%RH)                25-75                    50-65
         Barometric pressure (mbar)    860-1060                 950-1000


         Site Description: November 3, 1998 File on
                                 Federal Communications Commission
                                 FCC Engineering Laboratory
                                 7435 Oakland Mills Road
                                 Columbia, MD 21046
                                 Reference 31040/SIT1300F2

                                 September 30, 1998 Accreditation on NVLAP
                                 NVLAP Lab Code: 200347-0

                                 February 23, 1999 Accreditation on DNV
                                 Statement No. : 413-99-LAB11

                                 December 8, 1998 Registration on VCCI
                                 Registration No. for No.2 Shielded Room C-858
                                 Registration No. for No.1 Open Area Test Site R-823
                                 Registration No. for No.2 Open Area Test Site R-835

                                 January 04, 1999 Accreditation on TUV Rheinland
                                 Certificate No.: I9865712-9901


         Name of firm : QuieTek Corporation

         Site location      : No.75-1, Wang-Yeh Valley, Yung-Hsing Tsuen,
                                 Chiung-Lin, Hsin-Chu County, Taiwan, R.O.C.




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)                 QuieTek Corporation                     Page: 10 of 2
NVLAP Lab. Code : 200347-0                     EMC Test Laboratory                     Rev.1


2.       Conducted Emission
2.1      Test Equipment List

         The following test equipment are used during the conducted emission test:
         Item Instrument                    Manufacturer Type No./Serial No                      Last Cal..     Remark
         1       Test Receiver              R&S                ESCS 30/825442/17                 May, 1999
         2       L.I.S.N.                   R&S                ESH3-Z5/825016/6                  May, 1999      EUT
         3       L.I.S.N.                   Kyoritsu           KNW-407/8-1420-3                  May, 1999      Peripherals
         4       Pulse Limiter              R&S                ESH3-Z2                           N/A
         5        N0.2 Shielded Room                                                             N/A
         Note: All equipment upon which need to calibrated are with calibration period of 1 year.

2.2      Test Setup

                                                                               Reference Plane

                         Test Receiver
                                                                                                   40cm


                      12dBuV                                                  EUT
                      ooo                                          Load
                      ooo




                                                  LISN                                       LISN


                                                                                 LISN
                                         Ground Plane

2.3      Limits

                     CISPR 22 Limits (dBuV)                                   FCC Part 15 Subpart B (dBuV)

             Frequency            Class A                Class B          Frequency              Class A       Class B

                MHz             QP         AV      MHz        AV            MHz            uV        dBuV     uV    dBuV

             0.15 - 0.50        79         66      66-56 56-46            0.45-1.705      1000       60.0     250     48.0

              0.50-5.0          73         60           56    46          1.705-30        3000       69.5     250     48.0

              5.0 - 30          73         60           60    50

         Remarks : In the above table, the tighter limit applies at the band edges.


FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)                          QuieTek Corporation                                   Page: 11 of 2
NVLAP Lab. Code : 200347-0                              EMC Test Laboratory                                   Rev.1


2.4      Test Procedure
         The EUT and simulators are connected to the main power through a line impedance
         stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the
         measuring equipment. The peripheral devices are also connected to the main power through a
         LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please
         refers to the block diagram of the test setup and photographs.)
         Both sides of A.C. line are checked for maximum conducted interference. In order to find the
         maximum emission, the relative positions of equipment and all of the interface cables must be
         changed according to ANSI C63.4 /1992 on conducted measurement.
         The bandwidth of the field strength meter (R & S Test Receiver ESCS 30) is set at 9kHz.


2.5      Test Results
         The conducted emission from the EUT is measured and shown in Attachment 1 of test report.
         The acceptance criterion was met and the EUT passed the test.




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)           QuieTek Corporation                         Page: 12 of 2
NVLAP Lab. Code : 200347-0               EMC Test Laboratory                         Rev.1


3.       Radiated Emission

3.1      Test Equipment

         The following test equipment are used during the radiated emission test:

          Test Site              Equipment               Manufacturer      Model No./Serial No.         Last Cal.

         Site # 1        X       Test Receiver         R&S               ESCS 30 / 825442/14            May, 1999
                                 Spectrum Analyzer Advantest             R3261C / 71720140              May, 1999
                                 Pre-Amplifier         HP                8447D/3307A01812               May, 1999

                         X       Bilog Antenna         Chase             CBL6112B / 12452               Sep., 1999

                         X       Horn Antenna          EM                EM6917 / 103325                May, 1999
         Site # 2        X       Test Receiver         R&S               ESCS 30 / 825442/17            May, 1999
                                 Spectrum Analyzer Advantest             R3261C / 71720609              May, 1999
                                 Pre-Amplifier         HP                8447D/3307A01814               May, 1999

                         X       Bilog Antenna         Chase             CBL6112B / 2455                Sep., 1999

                         X       Horn Antenna          EM                EM6917 / 103325                May, 1999
            Note:      1. All equipment upon which need to calibrated are with calibration period of 1 year.
                       2.. Mark “X” test instruments are used to measure the final test results.

3.2      Test Setup

                                                                           3m or 10m


                             FRP Dome
                                                                                                                 1m to 4m




                                                                                   Antenna Mast
                                                                                   Broadband or
                                                                                   Dipole Antenna
                                                                                   Antenna height can
                                                                                   be moved from 1m
                                                 EUT                               to 4m, Antenna and
                             Non-Condu                                             turntable distance
                             cted Table                                            3m or 10m
                                                            80cm

                                                                   Fully Soldered Metal Ground            To controller
                        Test                                                                                  To receiver
                      Receiver




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)                         QuieTek Corporation                               Page: 13 of 2
NVLAP Lab. Code : 200347-0                             EMC Test Laboratory                               Rev.1


3.3      Limits

                    CISPR 22 Limits (dBuV)                     FCC Part 15 Subpart B (dBuV)

           Frequency        Class A        Class B        Frequency     Class A            Class B

                        Distance        Distance
             MHz                 dBuV/m          dBuV/m                uV    dBuV     uV       dBuV
                          (m)             (m)

           30 – 230       10      40      10      30       30 – 88     90     39      100       40.0

          230 – 1000      10      47      10      37      88 – 216     150   43.5     150       43.5

                                                          216 –960     210   46.5     200       46.0

                                                          960 - 2000   300   49.5     500       54.0

         Remark: 1. The tighter limit shall apply at the edge between two frequency bands.

                    2. Distance refers to the distance in meters between the measuring instrument
                       antenna and the closed point of any part of the device or system.
                    3. RF Line Voltage (dBuV) = 20 log RF Line Voltage (uV)

3.4      Test Procedure
         The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The
         turn table can rotate 360 degrees to determine the position of the maximum emission level.
         The EUT was positioned such that the distance from antenna to the EUT was 10 meters .
         The antenna can move up and down between 1 meter and 4 meters to find out the maximum
         emission level.
         Both horizontal and vertical polarization of the antenna are set on measurement. In order to
         find the maximum emission, all of the interface cables must be manipulated according to
         ANSI C63.4 /1992 on radiated measurement.
         The bandwidth below 1GHz setting on the field strength meter (R&S Test Receiver ESCS 30 )
          is 120 kHz.


3.5      Test Results
         The radiated emission from the EUT is measured and shown in Attachment 1 of test report.
         The acceptance criterion was met and the EUT passed the test.




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)             QuieTek Corporation                             Page: 14 of 2
NVLAP Lab. Code : 200347-0                 EMC Test Laboratory                             Rev.1


4.       EMI Reduction Method During Compliance Testing


         No modification was made during testing.




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)          QuieTek Corporation   Page: 15 of 2
NVLAP Lab. Code : 200347-0              EMC Test Laboratory   Rev.1


5.       Attachment

         Attachment 1: Summary of Test Results         Number of Pages: 5

         Attachment 2: EUT Test Photographs            Number of Pages: 2

         Attachment 3: EUT detailed photographs        Number of Pages: 10




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)         QuieTek Corporation                   Page: 16 of 2
NVLAP Lab. Code : 200347-0             EMC Test Laboratory                   Rev.1


Attachment 1 : Summary of Test Results
         The test results in the emission was performed according to the requirements of measurement
         standard and process. QuieTek Corporation is assumed full responsibility for the accuracy and
         completeness of these measurements. The test data of the emission is listed as the attached
         data.
         All the tests were carried out with the EUT in normal operation, which was defined as:
         1).Mode 1 : Normal Operation(1200 CU PLUS)


         The EUT passed all the tests.


         The uncertainty is calculated in accordance with NAMAS NIS 81, The total uncertainty for
         this test is as follows:
         Ø Emission Test
            • Uncertainty in the Conducted Emission Test:                    < ± 2.0 dB
            • Uncertainty in the field strength measured:                    < ± 4.0 dB




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)            QuieTek Corporation                       Page: 1 of 2
NVLAP Lab. Code : 200347-0                EMC Test Laboratory                       Rev.1


                                    CONDUCTED EMISSION DATA
  Date of Test :                   Jan.17, 2000         EUT            :         Scanner
  Test Mode           :               Mode 1            Detect Mode    :   Quasi-Peak & Average


  Frequency         Cable          LISN   Reading Level        Measurement Level     Limits
                     Loss        Factor         Line1                  Line1
           MHz         dB            dB         dBuV                   dBuV           dBuV
  ========================================================================
      0.150    0.00    0.10       39.24              39.34          65.99
        0.187        0.01          0.10        35.22                  35.33          64.17
        0.231        0.02          0.10        29.47                  29.59          62.42
      11.253         0.29          0.24        35.38                  35.91          60.00
     *17.251         0.34          0.40        40.08                  40.82          60.00
      18.752         0.35          0.43        39.32                  40.09          60.00


Average:


        0.150        0.00          0.10        35.30                  35.40          56.00
        0.187        0.01          0.10        33.20                  33.31          54.17
       0.231         0.02          0.10        27.30                  27.42          52.41
      11.253         0.29          0.24        35.00                  35.53          50.00
      17.251         0.34          0.40        39.60                  40.34          50.00
      18.752         0.35          0.43        38.80                  39.57          50.00

         Remarks :
                  1. “ * ” means that this data is the worst emission level.




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)             QuieTek Corporation                     Page: 2 of 2
NVLAP Lab. Code : 200347-0                 EMC Test Laboratory                     Rev.1


                                    CONDUCTED EMISSION DATA
  Date of Test :                   Jan.24, 2000        EUT            :         Scanner
  Test Mode           :               Mode 1           Detect Mode    :   Quasi-Peak & Average


  Frequency         Cable          LISN   Reading Level       Measurement Level     Limits
                     Loss        Factor       Line2                 Line2
        MHz      dB      dB        dBuV               dBuV           dBuV
  ========================================================================
        0.150        0.00          0.10        38.61                 38.71          66.00
        0.190        0.01          0.10        36.33                 36.44          64.02
       0.401         0.05          0.10        27.83                 27.98          57.83
      12.753         0.30          0.29        35.85                 36.44          60.00
     *17.252         0.34          0.40        40.64                 41.38          60.00
      18.752         0.35          0.43        38.17                 38.94          60.00


Average:


        0.150        0.00          0.10        32.30                 32.40          56.00
        0.190        0.01          0.10        27.80                 27.91          54.04
        0.401        0.05          0.10        26.10                 26.25          47.83
      12.753         0.30          0.29        35.40                 35.99          50.00
      17.252         0.34          0.40        40.10                 40.84          50.00
      18.752         0.35          0.43        37.30                 38.07          50.00



         Remarks :
                      1. “ * ” means that this data is the worst emission level.




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)             QuieTek Corporation                    Page: 3 of 2
NVLAP Lab. Code : 200347-0                 EMC Test Laboratory                    Rev.1


                                     RADIATED EMISSION DATA
  Date of Test :                 Jan.24, 2000        EUT             :           Scanner
  Test Mode           :             Mode 1           Test Site       : No.2 Open Test Site
      Freq.      Cable     Probe PreAMP Reading Measurement Margin Limit Ant Turn
                  Loss Factor                Level   Horizontal
         MHz        dB   dB/m         dB      dBuV     dBuV/m            dB dBuV/m   cm   deg
  ========================================================================
    36.000   1.21 14.59    0.00    4.19     19.99   10.01 30.00 401    60
     48.000       1.33      8.92    0.00      1.92         12.17   17.83     30.00 401       77
     59.250       1.43      5.52    0.00      2.47          9.42   20.58     30.00 401       94
     60.000       1.44      5.49    0.00      4.35         11.28   18.72     30.00 401       94
     65.250       1.49      5.93    0.00      2.58          9.99   20.01     30.00 401       94
     72.000       1.55      6.94    0.00      2.64         11.14   18.86     30.00 401       77
    120.000       2.02     12.02    0.00      2.60         16.64   13.36     30.00 401       77
    144.000       2.24     11.16    0.00      2.72         16.12   13.88     30.00 401       77
    168.000       2.48      9.59    0.00      5.47         17.53   12.47     30.00 401       77
    180.000       2.60      9.47    0.00      5.63         17.69   12.31     30.00 401       77
    192.000       2.71      9.00    0.00      4.84         16.55   13.45     30.00 401       77
   216.023        2.94      9.11    0.00      8.26         20.31    9.69     30.00 401       87
  *228.023        3.06     10.08    0.00      8.95         22.08    7.92     30.00 401       77
    240.023       3.17     11.32    0.00      8.58         23.07   13.93    37.00 401      87
    252.023       3.29     12.84    0.00     10.12         26.25   10.75    37.00 401     114
    264.022       3.40     14.08    0.00      9.02         26.50   10.50     37.00 401    134
    288.022       3.63     13.11    0.00      6.06         22.80   14.20     37.00 401    164
    300.022       3.76     13.36    0.00      7.42         24.53   12.47     37.00 401    163
    312.035       3.82     13.50    0.00     10.13         27.45    9.55     37.00 318    175
    384.040       4.19     15.11    0.00      3.67         22.97   14.03     37.00 244    125



      Remarks:
                   1. All Readings below 1GHz are Quasi-Peak, above are average value.
                   2. “ * ”, means this data is the worst emission level.
                   3. Emission Level = Reading Level + Antenna Factor + Cable loss




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)             QuieTek Corporation                       Page: 4 of 2
NVLAP Lab. Code : 200347-0                 EMC Test Laboratory                       Rev.1


                                     RADIATED EMISSION DATA
  Date of Test :                 Jan.24, 2000        EUT             :           Scanner
  Test Mode           :             Mode 1           Test Site       : No.2 Open Test Site


      Freq.      Cable     Probe PreAMP Reading Measurement Margin Limit Ant Turn
                  Loss Factor                Level   Vertical
         MHz        dB   dB/m         dB      dBuV     dBuV/m            dB dBuV/m   cm   deg
  ========================================================================
   *36.000   1.21 14.68    0.00    6.96     22.84    7.16 30.00 103    73
     48.000       1.33      8.03    0.00     10.05         19.41   10.59     30.00 103       80
     60.000       1.44      6.00    0.00     11.10         18.54   11.46     30.00 103       80
     72.000       1.55      6.10    0.00     11.32         18.97   11.03     30.00 103     95
     84.000       1.67      8.26    0.00     12.06         21.99    8.01     30.00 103    110
    120.000       2.02     11.56    0.00      2.74         16.32   13.68     30.00 103     94
    288.000       3.63     13.17    0.00      0.49         17.30   19.70     37.00 103    110
    312.030       3.82     13.93    0.00      3.87         21.61   15.39     37.00 103    110




      Remarks:
                   1. All Readings below 1GHz are Quasi-Peak, above are average value.
                   2. “ * ”, means this data is the worst emission level.
                   3. Emission Level = Reading Level + Antenna Factor + Cable loss




FCC Report No.: 001H016FI
Accredited Lab. of NVLAP(NIST)             QuieTek Corporation                       Page: 5 of 2
NVLAP Lab. Code : 200347-0                 EMC Test Laboratory                       Rev.1



Document Created: 2000-01-28 15:48:24
Document Modified: 2000-01-28 15:48:24

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC