Report

FCC ID: HQXAXM-Q6

Test Report

Download: PDF
FCCID_1802243

                                                                                  Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1




                    FCC 47 CFR PART 15 SUBPART C
                                                           for
                                      Wireless Mini BlueScan Mouse
                                         Model: AXM-Q6 / 00033
                                        Brand: Sysgration / TUMI
                                           Test Report Number:
                                                 C120921Z04-RP1

                                                       Issued for

                                                  Sysgration Ltd.
            10FL, NO.868-3, Chung Rd, Chung Ho, Taipei, Taiwan, R.O.C.

                                                      Issued by:

                COMPLIANCE CERTIFICATION SERVICES (SHENZHEN) INC.

              No.10-1, Mingkeda Logistics Park, No.18, Huanguan South Rd.,
                    Guan Lan Town, Baoan District, Shenzhen, China
                                             TEL: 86-755-28055000
                                             FAX: 86-755-28055221
                                     Issued Date: September 21, 2012




Note: This report shall not be reproduced except in full, without the written approval of
Compliance Certification Services Inc. This document may be altered or revised by
Compliance Certification Services Inc. personnel only, and shall be noted in the revision
section of the document. The client should not use it to claim product endorsement by
TAF, A2LA, NVLAP, NIST or any government agencies. The test result of this report
relate only to the tested sample identified in this report.




FCC ID: HQXAXM-Q6                                                                                      Page 1/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



                                               Revision History

           Issue                                                                            Effect
                                                                                                         Revised By
 Rev.       No.                                             Revisions                       Page
  00 SZ120705B01-RP                                         Initial Issue                    ALL        Sunny Wang
   01     C120921Z04-RP1                                     Update                           ALL       Sunny Wang




Rev.01: (C120921Z04-RP1)
 Note: 1.The applicant company changed the sensor for the EUT. After the
         reassessment, the below 1GHz radiated emission was re-tested, the final test
         result and internal photos were changed.

          2. The other information, please refer to the Report No.: SZ120705B01-RP and
            this report.




FCC ID: HQXAXM-Q6                                                                                       Page 2/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                             Reference No.: SZ120705B01-RP
                                                                                                Report No.: C120921Z04-RP1



                                                   TABLE OF CONTENTS

1         TEST CERTIFICATION ...........................................................................................4
2         EUT DESCRIPTION.................................................................................................5
3         TEST METHODOLOGY...........................................................................................6
    3.1. DESCRIPTION OF TEST MODES.......................................................................................6
4         TEST METHODOLOGY...........................................................................................7
    4.1. EUT EXERCISE ...................................................................................................................7
    4.2. FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS............................................7
5         INSTRUMENT CALIBRATION ................................................................................8
6         SETUP OF EQUIPMENT UNDER TEST .................................................................8
    6.1. DESCRIPTION OF SUPPORT UNITS.................................................................................8
    6.2. CONFIGURATION OF SYSTEM UNDER TEST..................................................................8
7         FACILITIES AND ACCREDITATIONS ....................................................................9
    7.1. FACILITIES ..........................................................................................................................9
    7.2. ACCREDITATIONS..............................................................................................................9
    7.3. MEASUREMENT UNCERTAINTY .......................................................................................9
8         FCC PART 15.249 REQUIREMENTS ...................................................................10
    8.1. BAND EDGES MEASUREMENT .......................................................................................10
    8.2. POWER LINE CONDUCTED EMISSIONS MEASUREMENT ...........................................12
    8.3. SPURIOUS EMISSIONS MEASUREMENT .......................................................................19




FCC ID: HQXAXM-Q6                                                                                                    Page 3/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



1     TEST CERTIFICATION
Product                Wireless Mini BlueScan Mouse
Model                  AXM-Q6 / 00033
Brand                  Sysgration / TUMI
Tested                July 5~10, 2012 & September 20~21, 2012
                      Sysgration Ltd.
Applicant
                      10FL, NO.868-3, Chung Rd, Chung Ho, Taipei, Taiwan, R.O.C.
                      Sysgration (Shenzhen) Ltd.
Manufacturer
                      Egongling Village, Pinghu Town, Longgang Dist. Shenzhen City. China


                                           APPLICABLE STANDARDS
                         STANDARD                                                    TEST RESULT
            FCC 47 CFR Part 15 Subpart C                                      No non-compliance noted

                               DEVIATION FROM APPLICABLE STANDARD

                                                          None

We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data,
data evaluation, test procedures, and equipment configurations shown in this report
were made in accordance with the procedures given in ANSI C63.4:2009 and the energy
emitted by the sample EUT tested as described in this report is in compliance with the
requirements of FCC Rules Part 15.207, 15.209, 15.249.

The test results of this report relate only to the tested sample EUT identified in this
report.




Approved by:                                                     Reviewed by:




Tom Gan                                                          Aven Zhou
Supervisor of EMC Dept.                                          Supervisor of Report Dept.
Compliance Certification Service Inc.                            Compliance Certification Service Inc.




FCC ID: HQXAXM-Q6                                                                                       Page 4/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



2     EUT DESCRIPTION
 Product                             Wireless Mini BlueScan Mouse
 Model                               AXM-Q6 / 00033
 Brand                               Sysgration / TUMI
                                     All models are identical to each other, the brand name and the
                                     model names are different.
 Model Discrepancy
                                     1. The brand name of the model AXM-Q6 is Sysgration;
                                     2. The brand name of the model 00033 is TUMI.
 Identify Number                     C120921Z04-RP1

 Power Supply                        DC3V supplied by the battery

 Frequency Range                     2405-2476 MHz
                                     Peak: 84.31dBuV/m (Max.)
 Transmit Power
                                     Average: 60.84dBuV/m (Max.)
 Modulation Technique GFSK

 Number of Channels                  64 Channels

 Antenna Specification PCB Antenna with 2.0dBi gain(MAX)
 Temperature Range                   0°C ~ +40°C

Note: 1. The sample selected for test was engineering sample that approximated to production product
        and was provided by manufacturer.

       2. This submittal(s) (test report) is intended for FCC ID: HQXAXM-Q6 filing to comply with Section
         15.207, 15.209 and 15.249 of the FCC Part 15, Subpart C Rules.




FCC ID: HQXAXM-Q6                                                                                       Page 5/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



3     TEST METHODOLOGY
3.1. DESCRIPTION OF TEST MODES
The EUT had been tested under operating condition.
Test program used to control the EUT for staying in continuous transmitting and
receiving mode is programmed.
    The following test mode(s) were scanned during the preliminary test below 1G:
      Test Item                 Test mode                            Worse mode
                                Not applicable since the EUT
        Conducted Emission
                                supplied by the battery.
             Radiated Emission                Mode 1: TX



After verification, all tests were carried out with the worst case test modes as shown
below except radiated spurious emission below 1GHz, which worst case was in normal
link mode only.
Channel Low (2405MHz), Channel Mid (2439MHz) and Channel High (2476MHz) were
chosen for the final testing.


The field strength of spurious radiation emission was measured in the following position:
EUT stand-up position (Y mode) and lie-down position (X, Z mode) The following data
show only the worst case setup.
The worst case (X axis) was reported.




FCC ID: HQXAXM-Q6                                                                                       Page 6/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



4        TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI
C63.4:2009 and FCC CFR 15.209 and 15.249.

4.1. EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the
purpose of the measurements.
According to its specifications, the EUT must comply with the requirements of the
Section 15.209,15.249 under the FCC Rules Part 15 Subpart C.

4.2. FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
    (a) Except as shown in paragraph (d) of this section, only spurious emissions are
      permitted in any of the frequency bands listed below:
                 MHz                            MHz                          MHz                      GHz

             0.090 - 0.110      16.42 - 16.423     399.9 - 410                                    4.5 - 5.15
            1
             0.495 - 0.505   16.69475 - 16.69525    608 - 614                                    5.35 - 5.46
           2.1735 - 2.1905   16.80425 - 16.80475   960 - 1240                                    7.25 - 7.75
            4.125 - 4.128         25.5 - 25.67     1300 - 1427                                   8.025 - 8.5
          4.17725 - 4.17775       37.5 - 38.25    1435 - 1626.5                                    9.0 - 9.2
          4.20725 - 4.20775         73 - 74.6    1645.5 - 1646.5                                   9.3 - 9.5
            6.215 - 6.218         74.8 - 75.2      1660 - 1710                                   10.6 - 12.7
          6.26775 - 6.26825      108 - 121.94    1718.8 - 1722.2                                 13.25 - 13.4
          6.31175 - 6.31225        123 - 138       2200 - 2300                                   14.47 - 14.5
            8.291 - 8.294       149.9 - 150.05     2310 - 2390                                   15.35 - 16.2
            8.362 - 8.366        156.52475 -      2483.5 - 2500                                  17.7 - 21.4
          8.37625 - 8.38675        156.52525       2655 - 2900                                  22.01 - 23.12
          8.41425 - 8.41475      156.7 - 156.9     3260 - 3267                                   23.6 - 24.0
            12.29 - 12.293    162.0125 - 167.17    3332 - 3339                                   31.2 - 31.8
         12.51975 - 12.52025    167.72 - 173.2    3345.8 - 3358                                  36.43 - 36.5
         12.57675 - 12.57725       240 - 285       3600 - 4400                                         ( 2)
            13.36 - 13.41         322 - 335.4
     1
         Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
     2
         Above 38.6
    (b) Except as provided in paragraphs (d) and (e), the field strength of emissions
      appearing within these frequency bands shall not exceed the limits shown in Section
      15.209. At frequencies equal to or less than 1000 MHz, compliance with the limits in
      Section 15.209 shall be demonstrated using measurement instrumentation
      employing a CISPR quasi-peak detector. Above 1000 MHz, compliance with the
      emission limits in Section 15.209 shall be demonstrated based on the average value
      of the measured emissions. The provisions in Section 15.35 apply to these
      measurements.




FCC ID: HQXAXM-Q6                                                                                       Page 7/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



5       INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein,
has been calibrated in accordance with the manufacturer's recommendations for utilizing
calibration equipment, which is traceable to recognized national standards.

6       SETUP OF EQUIPMENT UNDER TEST
6.1. DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary
accessories or support units. The following support units or accessories were used to
form a representative test configuration during the tests.

 No.       Equipment         Model No.        Serial No.        FCC ID            Brand          Data Cable Power Cord

    1          N/A

Note:
1) Grounding was established in accordance with the manufacturer’s requirements and conditions for the
   intended use.

6.2. CONFIGURATION OF SYSTEM UNDER TEST
See test photographs attached in Appendix II for the actual connections between EUT
and support equipment.




FCC ID: HQXAXM-Q6                                                                                       Page 8/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



7     FACILITIES AND ACCREDITATIONS
7.1. FACILITIES
All measurement facilities used to collect the measurement data are located at
No.10-1, Mingkeda Logistics Park, No.18, Huanguan South Rd., Guan Lan Town,
Baoan District, Shenzhen, China

The sites are constructed in conformance with the requirements of ANSI C63.4:2009,
ANSI C63.7 and CISPR Publication 22. All receiving equipment conforms to CISPR
Publication 16-1, “Radio Interference Measuring Apparatus and Measurement Methods.”

7.2. ACCREDITATIONS
Our laboratories are accredited and approved by the following accreditation body
according to ISO/IEC 17025.
              USA               A2LA
              China             CNAS
The measuring facility of laboratories has been authorized or registered by the following
approval agencies.
              USA               FCC
              Japan             VCCI(C-3478, R-3135, T-652)
              Canada            INDUSTRY CANADA
              Taiwan            BSMI
              Norway            Nemko
Copies of granted accreditation certificates are available for downloading from our web
site, http://www.ccsrf.com

7.3. MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for
tests performed on the EUT as specified in CISPR 16-4-2:
          Measurement                   Frequency                   Uncertainty
      Conducted emissions              9kHz~30MHz                    +/- 3.18dB
                                    30MHz ~ 200MHz                   +/- 3.79dB
       Radiated emissions          200MHz ~1000MHz                   +/- 3.62dB
                                     Above 1000MHz                   +/- 5.04dB
           Band Edges                 +/-0.182 dB
This uncertainty represents an expanded uncertainty expressed at approximately
the 95% confidence level using a coverage factor of k=2.
The measured result is above (below) the specification limit by a margin less than the
measurement uncertainty; it is therefore not possible to state compliance based on the
95% level of confidence. However, the result indicates that compliance (non-compliance)
is more probable than non-compliance) with the specification limit.




FCC ID: HQXAXM-Q6                                                                                       Page 9/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



8     FCC PART 15.249 REQUIREMENTS
8.1. BAND EDGES MEASUREMENT
LIMIT
1. In the above emission table, the tighter limit applies at the band edges.

                                                        Field Strength                         Field Strength
               Frequency (Hz)
                                                     (μV/m at 3-meter)                     (dBμV/m at 3-meter)
                     30-88                                    100                                     40
                     88-216                                   150                                    43.5
                    216-960                                   200                                     46
                  Above 960                                   500                                     54
2. As shown in Section 15.35(b), for frequencies above 1000 MHz, the above field strength
     limits in paragraphs (a) and (b) of this section are based on average limits. However, the
     peak field strength of any emission shall not exceed the maximum permitted average
     limits specified above by more than 20 dB under any condition of modulation. For
     point-to-point operation under paragraph (b) of this section, the peak field strength shall
     not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.
3. As shown in Section 15.249(d) Emissions radiated outside of the specified frequency
     bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the
     fundamental or to the general radiated emission limits in Section 15.209, whichever is the
     lesser attenuation.

    MEASUREMENT EQUIPMENT USED
                                    Radiated Emission Test Site 966(2)
           Name of                                          Model              Serial           Last        Due
                                  Manufacturer
          Equipment                                        Number             Number         Calibration Calibration
     PSA Series Spectrum
                             Agilent                        E4446A          US44300399         03/19/2012      03/19/2013
          Analyzer
       ESCI EMI TEST
                         ROHDE&SCHWARZ                       ESCI              100783          03/17/2012      03/17/2013
        RECEIVE.ESCI
             Amplifier                 MITEQ            AM-1604-3000          1123808          03/18/2012      03/18/2013

            Turn Table                 EMCO                2081-1.21             N/A             N.C.R            N.C.R

            Controller                   CT                   N/A                N/A             N.C.R            N.C.R

       High Noise Amplifier            Agilent               8449B          3008A01838         03/18/2012      03/18/2013

          Bilog Antenna            SCHAFFNER               CBL6143              5082           03/17/2012      03/17/2013

          Horn Antenna           SCHWARZBECK              BBHA9120              D286           03/17/2012      03/17/2013

          Loop Antenna                A、R、A               PLA-1030/B            1029           03/23/2012      03/23/2013

     Temp. / Humidity Meter           VICTOR                VC230                N/A           03/19/2012      03/19/2013

         Antenna Tower                SUNOL                  TLT2                N/A             N.C.R            N.C.R

            Test S/W                  FARAD                                    LZ-RF / CCS-SZ-3A2

    Remark: Each piece of equipment is scheduled for calibration once a year.




FCC ID: HQXAXM-Q6                                                                                       Page 10/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



Test Configuration

                                                                              Antenna
                                                                               tower


                        3m                                                    Horn
                                                                             antenna
    EUT
                               4m
                                                                              Spectrum
                                                                              analyzer


         Turntable                  1m
                      0.8m
                                              30cm
                                                                                 Pre-amp



TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above the ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
   out the highest emission.
4. Set the spectrum analyzer in the following setting in order to capture the lower and
   upper band-edges of the emission:
    (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
    (b) AVERAGE: RBW=1MHz / VBW=510Hz / Sweep=AUTO
5. Repeat the procedures until all the PEAK and AVERAGE versus POLARIZATION are
   measured.

TEST RESULTS
Refer to attach spectrum analyzer data chart.




FCC ID: HQXAXM-Q6                                                                                       Page 11/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1



Test Data
Band Edges (CH-Low)
Detector mode: Peak                                             Polarity: Vertical




Detector mode: Average                                    Polarity: Vertical




FCC ID: HQXAXM-Q6                                                                                       Page 12/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                  Reference No.: SZ120705B01-RP
                                                                                     Report No.: C120921Z04-RP1




Detector mode: Peak                                         Polarity: Horizontal




Detector mode: Average                                Polarity: Horizontal




FCC ID: HQXAXM-Q6                                                                                       Page 13/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Reference No.: SZ120705B01-RP
                                                                                        Report No.: C120921Z04-RP1


   Band Edges (CH-High)

    Detector mode: Peak                                           Polarity: Vertical




    Detector mode: Average                                    Polarity: Vertical




FCC ID: HQXAXM-Q6                                                                                      Page 14/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1




    Detector mode: Peak                                         Polarity: Horizontal




    Detector mode: Average                                   Polarity: Horizontal




FCC ID: HQXAXM-Q6                                                                                      Page 15/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                      Reference No.: SZ120705B01-RP
                                                                                        Report No.: C120921Z04-RP1

8.2. POWER LINE CONDUCTED EMISSIONS MEASUREMENT
8.2.1. LIMITS OF CONDUCTED EMISSIONS MEASUREMENT
According to §15.207(a), except as shown in paragraphs (b) and (c) of this section, for an
intentional radiator that is designed to be connected to the public utility (AC) power line, the
radio frequency voltage that is conducted back onto the AC power line on any frequency or
frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following
table, as measured using a 50 µH/50 ohms line impedance stabilization network (LISN).
Compliance with the provisions of this paragraph shall be based on the measurement of the
radio frequency voltage between each power line and ground at the power terminal. The
lower limit applies at the boundary between the frequency ranges.
                                                                             Limits
      Frequency Range                                                       (dBμV)
           (MHz)
                                                   Quasi-peak                                     Average
          0.15 to 0.50                              66 to 56*                                     56 to 46*
            0.50 to 5                                   56                                            46
             5 to 30                                    60                                            50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.
(3) All emanations from a class A/B digital device or system, including any network of conductors and
    apparatus connected thereto, shall not exceed the level of field strengths specified above.

8.2.2. TEST INSTRUMENTS

                                        Conducted Emission Test Site
                                                                               Serial           Last        Due
Name of Equipment             Manufacturer           Model Number
                                                                              Number         Calibration Calibration
    ESCI EMI TEST
                            ROHDE&SCHWARZ                    ESCI              100783         03/17/2012       03/17/2013
    RECEIVE.ESCI
       LISN(EUT)               SCHAFFNER                   NNB42              2001/001        03/19/2012       03/19/2013

          LISN                     EMCO                    3825/2            8901-1459        03/19/2012       03/19/2013

Temp. / Humidity Meter            VICTOR                   HTC-1                  2           03/20/2012       03/20/2013

        Test S/W                   FARAD                                    EZ-EMC/ CCS-3A1-CE

NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.




FCC ID: HQXAXM-Q6                                                                                      Page 16/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1

8.2.3. TEST PROCEDURES (please refer to measurement standard)

z   The EUT and Support equipment, if needed, was placed on a non-conducted table,
    which is 0.8m above the ground plane and 0.4m away from the conducted wall.

z   The test equipment EUT installed received AC main power, through a Line Impedance
    Stabilization Network (LISN), which supplied power source and was grounded to the
    ground plane. All support equipment power received from a second LISN. The two
    LISNs provide 50 ohm/ 50uH of coupling impedance for the measuring instrument.
z   The EUT test program was started. Emissions were measured on each current carrying
    line of the EUT using an EMI Test Receiver connected to the LISN powering the EUT.
z   The frequency range from 150 kHz to 30 MHz was searched. The test data of the
    worst-case condition(s) was recorded. Emission levels under limit 20dB were not
    recorded.




FCC ID: HQXAXM-Q6                                                                                      Page 17/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1

8.2.4. TEST SETUP


                                                       Vert. reference plane

                                                                                                     EMI receiver



                           40cm
                                          EUT



                                                                80cm




               LISN                                                    Reference ground plane



    z     For the actual test configuration, please refer to the related item – Photographs of the Test
        Configuration.

8.2.5. DATA SAMPLE

Frequency QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average Remark
           Reading Reading   Factor     Result    Result   Limit    Limit   Margin   Margin
  (MHz)    (dBuV)   (dBuV)    (dB)      (dBuV)   (dBuV)   (dBuV)   (dBuV)    (dB)     (dB) (Pass/Fail)

 X.XXXX        32.69       25.65      11.52       44.21       37.17       65.78      55.79      -21.57      -18.62      Pass


Factor         = Insertion loss of LISN + Cable Loss
Result         = Quasi-peak Reading/ Average Reading + Factor
Limit          = Limit stated in standard
Margin         = Result (dBuV) – Limit (dBuV)


8.2.6. TEST RESULTS

Not applicable, since the EUT supplied by the battery.




FCC ID: HQXAXM-Q6                                                                                        Page 18/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1

8.3. SPURIOUS EMISSIONS MEASUREMENT
8.3.1. LIMITS OF RADIATED EMISSIONS MEASUREMENT

1. In the section 15.249(a):
   Except as provided in paragraph (b) of this section, the field strength of emissions from
   intentional radiators operated within these frequency bands shall comply with the following:

              Fundamental                 Field Strength of Fundamental              Field Strength of Harmonics
                Frequency                      Field Strength (mV/m)                               (μV/m)
              902-928 MHz                                   50                                       500
          2400 - 2483.5 MHz                                 50                                       500
            5725 - 5875 MHz                                 50                                       500
            24.0 - 24.25 GHz                               250                                      2500



2. Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall
    not exceed the field strength levels specified in the following table:

              Frequency (MHz)                      Field Strength (μV/m)              Measurement Distance (m)
                 0.009-0.490                            2400/F(kHz)                                  300
                 0.490-1.705                            24000/F(kHz)                                  30
                  1.705-30.0                                   30                                     30
                     30-88                                   100*                                      3
                     88-216                                  150*                                      3
                    216-960                                  200*                                      3
                Above 960                            500                         3
    Remark: Except as provided in paragraph (g), fundamental emissions from intentional radiators
    operating under this Section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz,
    174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under
    other sections of this Part, e.g., Sections 15.231 and 15.241.

3. In the above emission table, the tighter limit applies at the band edges.

                                                        Field Strength                         Field Strength
               Frequency (Hz)
                                                     (μV/m at 3-meter)                     (dBμV/m at 3-meter)
                     30-88                                    100                                     40
                     88-216                                   150                                    43.5
                    216-960                                   200                                     46
                  Above 960                                   500                                     54




FCC ID: HQXAXM-Q6                                                                                      Page 19/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                     Reference No.: SZ120705B01-RP
                                                                                       Report No.: C120921Z04-RP1

8.3.2. TEST INSTRUMENTS

                                 Radiated Emission Test Site 966(2)
                                                         Model             Serial            Last        Due
Name of Equipment              Manufacturer
                                                        Number            Number          Calibration Calibration
 PSA Series Spectrum
                                    Agilent              E4446A          US44300399         03/19/2012       03/19/2013
      Analyzer
   ESCI EMI TEST
                             ROHDE&SCHWARZ                ESCI              100783          03/17/2012       03/17/2013
    RECEIVE.ESCI
          Amplifier                 MITEQ            AM-1604-3000          1123808          03/18/2012       03/18/2013

         Turn Table                 EMCO                2081-1.21             N/A             N.C.R            N.C.R

          Controller                  CT                   N/A                N/A             N.C.R            N.C.R

     High Noise Amplifier           Agilent               8449B          3008A01838         03/18/2012       03/18/2013

        Bilog Antenna           SCHAFFNER               CBL6143              5082           03/17/2012       03/17/2013

        Horn Antenna          SCHWARZBECK              BBHA9120              D286           03/17/2012       03/17/2013

        Loop Antenna               A、R、A               PLA-1030/B            1029           03/23/2012       03/23/2013

 Temp. / Humidity Meter            VICTOR                VC230                N/A           03/19/2012       03/19/2013

       Antenna Tower                SUNOL                 TLT2                N/A             N.C.R            N.C.R

          Test S/W                  FARAD                                   LZ-RF / CCS-SZ-3A2

NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. The FCC Site Registration number is 101879.
      3. N.C.R = No Calibration Required.

8.3.3 TEST PROCEDURE (please refer to measurement standard)
1.     The EUT is placed on a turntable, which is 0.8m above ground plane.
2.     The turntable shall be rotated for 360 degrees to determine the position of maximum
       emission level.
3.     EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
       out the highest emissions.
4.     Maximum procedure was performed on the six highest emissions to ensure EUT
       compliance.
5.     And also, each emission was to be maximized by changing the polarization of
       receiving antenna both horizontal and vertical.
6.     Set the spectrum analyzer in the following setting as:
       Below 1GHz:
             RBW=100kHz / VBW=300kHz / Sweep=AUTO
       Above 1GHz:
             (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
             (b) AVERAGE: RBW=1MHz / VBW=10Hz / Sweep=AUTO
7.     Repeat above procedures until the measurements for all frequencies are complete.



FCC ID: HQXAXM-Q6                                                                                      Page 20/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1


8.3.2.1. TEST SETUP

Below 30MHz


                                                                                         Antenna
                                                                                          tower


                                      3m
                                                                                            Loop antenna
          EUT
                                        4m
                                                                                         Spectrum /
                                                                                          Receiver


                 Turntable                    1m
                               0.8m
                                                                                        Pre-amp




    Reference ground plane



Below 1 GHz


                                                                                              Antenna
                                                                                               tower


                                       3m                                                     Bi-log
                                                                                             antenna
                EUT
                                              4m
                                                                                            Spectrum
                                                                                            analyzer


                       Turntable                   1m
                                      0.8m




           Reference ground plane




FCC ID: HQXAXM-Q6                                                                                       Page 21/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1

Above 1 GHz


                                                                                       Antenna
                                                                                        tower


                                 3m                                                    Horn
                                                                                      antenna
            EUT
                                        4m
                                                                                      Spectrum
                                                                                      analyzer


                 Turntable                   1m
                               0.8m
                                                       30cm
                                                                                         Pre-amp



For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.


8.3.2.2. DATA SAMPLE
Below 1GHz
                                    Correction                                                       Antenna
   Frequency         Reading                           Result           Limit          Margin                       Remark
                                     Factor                                                           Pole
     (MHz)           (dBuV)                          (dBuV/m)         (dBuV/m)          (dB)
                                     (dB/m)                                                           (V/H)
   XXX.XXXX            37.47           -16.41           21.06           40.00          -18.94            V              QP


Above 1GHz
                                    Correction                                                       Antenna
   Frequency         Reading                           Result           Limit         Margin                        Remark
                                     Factor                                                           Pole
     (MHz)           (dBuV)                          (dBuV/m)         (dBuV/m)         (dB)
                                     (dB/m)                                                           (V/H)
  XXXX.XXXX            55.54            4.56            60.10           74.00          -13.90            V              Peak
  XXXX.XXXX            29.66            4.56            34.22           54.00          -19.78            V              AVG

Frequency (MHz)                       = Emission frequency in MHz
Reading (dBuV)                        = Uncorrected Analyzer / Receiver reading
Correction Factor (dB/m)              = Antenna factor + Cable loss – Amplifier gain
Result (dBuV/m)                       = Reading (dBuV) + Corr. Factor (dB/m)
Limit (dBuV/m)                        = Limit stated in standard
Margin (dB)                           = Result (dBuV/m) – Limit (dBuV/m)
Q.P.                                  = Quasi-peak Reading
Peak                                  = Peak Reading
AVG                                   = Average Reading




FCC ID: HQXAXM-Q6                                                                                      Page 22/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1

8.3.2.3. TEST RESULTS

Below 1 GHz
Operation Mode:              TX                                          Test Date:         September 20, 2012
Temperature:                 24°C                                        Tested by:         Sunday Hu
Humidity:                    52% RH                                      Polarity:          Ver. / Hor.


 Frequency        Reading        Correction Result     Limit                   Margin       Antenna
                                  Factor                                                     Pole          Remark
    (MHz)          (dBμV)         (dB/m)    (dBμV/m) (dBμV/m)                    (dB)
                                                                                             (V/H)
  363.0332          33.77           -16.63          17.14         46.00         -28.86           V            QP
  495.6000          33.33           -13.93          19.40         46.00         -26.60           V            QP
  686.3667          32.77           -11.74          21.03         46.00         -24.97           V            QP
  791.4500          33.36           -10.30          23.06         46.00         -22.94           V            QP
  860.9664          33.41           -9.31           24.10         46.00         -21.90           V            QP
  961.2000          32.65           -8.63           24.02         54.00         -29.98           V            QP


  295.1333          35.94           -19.19          16.75         46.00         -29.25           H            QP
  569.9664          34.28           -12.54          21.74         46.00         -24.26           H            QP
  613.6167          35.68           -12.23          23.45         46.00         -22.55           H            QP
  796.3000          33.48           -10.34          23.14         46.00         -22.86           H            QP
  827.0167           33.11          -9.73           23.38         46.00         -22.62           H            QP
  961.2000          33.73           -8.63           25.10         54.00         -28.90           H            QP

Remark: No emission found between lowest internal used/generated frequency to 30MHz.

Notes:

          1. Measuring frequencies from 9kHz to the 1GHz.
          2. Radiated emissions measured in frequency range from 30MHz to 1GHz were made with an
            instrument using Peak/Quasi-peak detector mode.
         3. Data of measurement within this frequency range shown “ --- ” in the table above means the
         reading of emissions are attenuated more than 20dB below the permissible limits or the field strength
         is too small to be measured.

      4. The IF bandwidth of SPA between 30MHz to 1GHz was 100kHz.




FCC ID: HQXAXM-Q6                                                                                      Page 23/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1

Above 1 GHz
Operation Mode:               TX / CH Low                            Test Date:                   July 5, 2012
Temperature:                  24°C                                   Tested by:                   Sunday Hu
Humidity:                     52% RH                                 Polarity:                    Ver. / Hor.
Fundamental
  Frequency          Reading       Correction         Result          Limit          Margin        Antenna         Remark
    (MHz)                           Factor                                            (dB)          Pole
                     (dBuV)          (dB/m)         (dBuV/m)        (dBuV/m)                         (V/H)
  2405.0000           91.47            -9.72           81.75         114.00          -32.25             V               Peak
  2405.0000           67.75            -9.72           58.03          94.00          -35.97             V               AVG
  2405.0000           94.03            -9.72          84.31          114.00          -29.69            H                Peak
  2405.0000           70.56            -9.72          60.84           94.00          -33.16            H                AVG



 Frequency          Reading       Correction   Result   Limit                       Margin         Antenna        Remark
                                   Factor                                                           Pole
    (MHz)            (dBuV)        (dB/m)    (dBuV/m) (dBuV/m)                        (dB)          (V/H)
 1450.0000            48.16         -7.38      40.78    74.00                        -33.22           V             Peak
 2890.0000            46.73         -3.70      43.03    74.00                        -30.97           V             Peak
 3235.0000            46.45         -2.98      43.47    74.00                        -30.53           V             Peak
 4135.0000            45.68         -0.58      45.10    74.00                        -28.90           V             Peak
 4810.0000            52.94          1.83      54.77    74.00                        -19.23           V             Peak
 4810.0000            34.42          1.83      36.25    54.00                        -17.75           V             AVG
 5230.0000            45.35          2.92      48.27    74.00                        -25.73           V             Peak

 1390.0000            48.82           -7.22           41.60           74.00          -32.40             H           Peak
 1525.0000            47.37           -7.70           39.67           74.00          -34.33             H           Peak
 2935.0000            47.08           -3.52           43.56           74.00          -30.44             H           Peak
 3685.0000            45.83           -1.66           44.17           74.00          -29.83             H           Peak
 4300.0000            45.78           0.09            45.87           74.00          -28.13             H           Peak
 4810.0000            53.19           1.83            55.02           74.00          -18.98             H           Peak
 4810.0000            34.76           1.83            36.59           54.00          -17.41             H           AVG

REMARKS:
      1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental
         frequency.
      2. Radiated emissions measured in frequency above 1000MHz were made with an
         instrument using peak/average detector mode.
      3. Average test would be performed if the peak result were greater than the average
         limit or as required by the applicant.
      4. Data of measurement within this frequency range shown “ --- ” in the table above
         means the reading of emissions are attenuated more than 20dB below the
         permissible limits or the field strength is too small to be measured.
      5. Measurements above show only up to 6 maximum emissions noted, or would be
         lesser, with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
         margin>20dB from the applicable limit) and considered that's already beyond the
         background noise floor.
      6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m).
FCC ID: HQXAXM-Q6                                                                                      Page 24/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1




Operation Mode:               TX / CH Mid                                   Test Date:         July 5, 2012
Temperature:                  24°C                                          Tested by:         Sunday Hu
Humidity:                     52% RH                                        Polarity:          Ver. / Hor.
Fundamental
  Frequency          Reading       Correction         Result          Limit          Margin        Antenna         Remark
    (MHz)                           Factor                                            (dB)          Pole
                     (dBuV)          (dB/m)         (dBuV/m)        (dBuV/m)                         (V/H)
  2439.0000           91.64            -9.77           81.87         114.00          -32.13             V               Peak
  2439.0000           68.20            -9.77           58.43          94.00          -35.57             V               AVG
  2439.0000           93.46            -9.77          83.69          114.00          -30.31            H                Peak
  2439.0000           70.29            -9.77          60.52           94.00          -33.48            H                AVG



 Frequency          Reading       Correction   Result   Limit                       Margin         Antenna        Remark
                                   Factor                                                           Pole
    (MHz)            (dBuV)        (dB/m)    (dBuV/m) (dBuV/m)                        (dB)          (V/H)
 1360.0000            48.15         -7.37      40.78    74.00                        -33.22           V             Peak
 3040.0000            46.86         -3.21      43.65    74.00                        -30.35           V             Peak
 3760.0000            45.79         -1.55      44.24    74.00                        -29.76           V             Peak
 4375.0000            45.10          0.47      45.57    74.00                        -28.43           V             Peak
 4885.0000            49.89          2.16      52.05    74.00                        -21.95           V             Peak
 5710.0000            45.09          3.92      49.01    74.00                        -24.99           V             Peak

 1465.0000            49.63           -7.45           42.18           74.00          -31.82             H           Peak
 3205.0000            46.43           -2.99           43.44           74.00          -30.56             H           Peak
 3490.0000            46.21           -2.41           43.80           74.00          -30.20             H           Peak
 3895.0000            46.34           -1.21           45.13           74.00          -28.87             H           Peak
 4405.0000            44.76           0.62            45.38           74.00          -28.62             H           Peak
 4885.0000            51.35           2.16            53.51           74.00          -20.49             H           Peak

REMARKS:
      1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental
         frequency.
      2. Radiated emissions measured in frequency above 1000MHz were made with an
         instrument using peak/average detector mode.
      3. Average test would be performed if the peak result were greater than the average
         limit or as required by the applicant.
      4. Data of measurement within this frequency range shown “ --- ” in the table above
         means the reading of emissions are attenuated more than 20dB below the
         permissible limits or the field strength is too small to be measured.
      5. Measurements above show only up to 6 maximum emissions noted, or would be
         lesser, with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
         margin>20dB from the applicable limit) and considered that's already beyond the
         background noise floor.
      6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m).

FCC ID: HQXAXM-Q6                                                                                      Page 25/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services


                                                                                    Reference No.: SZ120705B01-RP
                                                                                      Report No.: C120921Z04-RP1


Operation Mode:               TX / CH High                                    Test Date:         July 5, 2012
Temperature:                  24°C                                            Tested by:         Sunday Hu
Humidity:                     52% RH                                          Polarity:          Ver. / Hor.
Fundamental
  Frequency          Reading       Correction         Result          Limit          Margin        Antenna         Remark
    (MHz)                           Factor                                            (dB)          Pole
                     (dBuV)          (dB/m)         (dBuV/m)        (dBuV/m)                         (V/H)
  2476.0000           91.74            -9.78           81.96         114.00          -32.04             V               Peak
  2476.0000           68.60            -9.78           58.82          94.00          -35.18             V               AVG
  2476.0000           92.96            -9.78          83.18          114.00          -30.82            H                Peak
  2476.0000           69.87            -9.78          60.09           94.00          -33.91            H                AVG



 Frequency          Reading       Correction   Result   Limit                       Margin         Antenna        Remark
                                   Factor                                                           Pole
    (MHz)            (dBuV)        (dB/m)    (dBuV/m) (dBuV/m)                        (dB)          (V/H)
 1360.0000            49.35         -7.37      41.98    74.00                        -32.02           V             Peak
 2845.0000            47.29         -3.88      43.41    74.00                        -30.59           V             Peak
 3310.0000            47.17         -2.95      44.22    74.00                        -29.78           V             Peak
 3790.0000            46.79         -1.50      45.29    74.00                        -28.71           V             Peak
 4525.0000            44.79          1.15      45.94    74.00                        -28.06           V             Peak
 4945.0000            48.52          2.42      50.94    74.00                        -23.06           V             Peak

 2110.0000            47.40           -7.72           39.68           74.00          -34.32             H           Peak
 3325.0000            48.07           -2.95           45.12           74.00          -28.88             H           Peak
 3835.0000            46.76           -1.39           45.37           74.00          -28.63             H           Peak
 4660.0000            44.47           1.57            46.04           74.00          -27.96             H           Peak
 4945.0000            50.29           2.42            52.71           74.00          -21.29             H           Peak
 5665.0000            45.09           3.77            48.86           74.00          -25.14             H           Peak

REMARKS:
  1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental
     frequency.
  2. Radiated emissions measured in frequency above 1000MHz were made with an
     instrument using peak/average detector mode.
  3. Average test would be performed if the peak result were greater than the average limit
     or as required by the applicant.
  4. Data of measurement within this frequency range shown “ --- ” in the table above
     means the reading of emissions are attenuated more than 20dB below the permissible
     limits or the field strength is too small to be measured.
  5. Measurements above show only up to 6 maximum emissions noted, or would be lesser,
     with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
     margin>20dB from the applicable limit) and considered that's already beyond the
     background noise floor.
  6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m).


FCC ID: HQXAXM-Q6                                                                                      Page 26/26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services



Document Created: 2012-09-21 16:00:42
Document Modified: 2012-09-21 16:00:42

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC