 Prüfbericht - Nr.:             17039818 001                                      Seite 27 von 31
 Test Report No.                                                                  Page 27 of 31


  6. Safety Human exposure



  6.1 Radio Frequency Exposure Compliance


  6.1.1 Electromagnetic Fields

  RESULT:                                                                           Passed

  Test standard             :      FCC KDB Publication 447498
                                   RSS-102 Issue 4



  The minimum distance for the EUT is 5mm, since maximum peak output power of the
  transmitter is 0.258mW (-5.89dBm), which is far below the SAR exclusion threshold level 10
  mW (Appendix A, SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤50 mm),
  hence the EUT is excluded from SAR evaluation according to FCC KDB publication 447498
  D01: Mobile and Portable RF Exposure.Guidance v05.

  And the EUT is exempted from routine evaluation limits (SAR Evaluation) according to
  clause 2.5.1 of RSS-102 Issue 4 as well.