MPE

FCC ID: HLZWPC3

RF Exposure Info

Download: PDF
FCCID_3899594

                                                                                                                                  Report No.: ER/2018/50050
                                                                                                                                   Page: 1 of 7



1       MAXIMUM PERMISSIBLE EXPOSURE (MPE)
1.1        Standard Applicable
     According to §1.1307(b)(1) and , systems operating under the provisions of this section shall be
     operated in a manner that ensure that the public is not exposed to radio frequency energy level
     in excess of the Commission’s guideline.
     According to §1.1310 and §2.1093 RF exposure is calculated.


     According to the specifications of the manufacturer, the EUT must comply with the requirements of
     the following standards:
     FCC KDB 680106


1.2        Limits for Maximum Permissive Exposure (MPE)
           Frequency        Electric Field     Magnetic Field     Power Density                                                                                   Averaging Time
              Range       Strength(E) (V/m) Strength(H) (A/m)        (mW/cm2)                                                                                        (minute)
              (MHz)
                               Limits for Occupational / Controlled Exposure
              0.3-3.0            614                1.63                *(100)                                                                                          6
              3.0-30           1842/f              4.89/f             *(900/f2 )                                                                                        6
             30-300              61.4              0.163                  1.0                                                                                           6
            300-1500               /                  /                 F/300                                                                                           6
           1500-15000              /                  /                    5                                                                                            6
           Frequency        Electric Field     Magnetic Field     Power Density                                                                                   Averaging Time
              Range       Strength(E) (V/m) Strength(H) (A/m)        (mW/cm2)                                                                                        (minute)
              (MHz)
                            Limits for General Population/Uncontrolled Exposure
             0.3-1.34            614                1.63                *(100)                                                                                                   30
             1.34-30            824/f              2.19/f             *(180/f2 )                                                                                                 30
             30-300              27.5              0.073                  0.2                                                                                                    30
            300-1500               /                  /                F/1500                                                                                                    30
           1500-15000              /                  /                   1.0                                                                                                    30
  F = frequency in MHz
  * = Plane-wave equipment power density




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                          SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                      f (886-2) 2298-0488                     www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                  Report No.: ER/2018/50050
                                                                                                                                   Page: 2 of 7



1.3        Equipment Used in Tested System
                                                                                          Model
          Item              Equipment                      Mfr/Brand                                                  Series No. Data Cable Power Cord
                                                                                        /Type No.
             1.                     NA                             ---                          ---                           ---                       ---                       ---


1.4        The Worst Charging Condition:
                          Ancillary Equipment                                           Charging Condition                                                  Verdict
                                          Load                                                   Full Loading                                                 PASS
                                          Load                                                  99% Loading                                                   PASS
                                          Load                                                  50% Loading                                                   PASS
                         Load                         1% Loading                  PASS
         Note: For Wireless Power Consortium Qi specification, a lower operating frequency or
               high duty cycle result in the transfer of a higher amount of power and charging
               current.


1.5     Measurement Procedure:
      1. For devices designed for typical desktop applications, such a wireless charging pads, RF
          exposure evaluation should be conducted assuming a user separation distance of 15 cm
          and 20 cm. E and H field strength measurements or numerical modeling may be used to
          demonstrate compliance. Measurements should be made from all sides and the top of the
          primary/client pair, with the 15 cm and 20 cm measured from the center of the probe(s) to
          the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed
          versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                          SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                      f (886-2) 2298-0488                     www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                  Report No.: ER/2018/50050
                                                                                                                                   Page: 3 of 7



1.6        Measurement Equipment Used:
                 EQUIPMENT                                        MFR                        MODEL                       SERIAL                         LAST                CAL DUE.
                   TYPE                                                                     NUMBER                       NUMBER                         CAL.
               EM RADIATION                                   Wandel&
                                                                                              EMR-30                        M-0006                10/14/2017 10/13/2018
                       METER                               Goltermann


1.7        Test Set-up:




1.8        Maximum Permissible Exposure (MPE) Evaluation:
Full Loading
                                                                  Maximum Permissible Exposure
                    Probe from EUT Side                                      Test Distance                                   E-field                              H-field
                                       Front                                          15 cm                                     6.75                                0.023
                                        Left                                          15 cm                                     6.98                                0.029
                                       Right                                          15 cm                                     6.38                                0.039
                                        Top                                           15 cm                                     6.33                                0.033
                                     Bottom                                           15 cm                                     6.98                                0.031
                                                            Limit                                                               614                                  1.63

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                          SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                      f (886-2) 2298-0488                     www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                  Report No.: ER/2018/50050
                                                                                                                                   Page: 4 of 7



99% Loading
                                                                  Maximum Permissible Exposure
                    Probe from EUT Side                                      Test Distance                                   E-field                              H-field
                                       Front                                          15 cm                                     6.98                                0.031
                                        Left                                          15 cm                                     6.55                                0.039
                                       Right                                          15 cm                                     6.33                                0.032
                                        Top                                           15 cm                                     6.12                                0.033
                                     Bottom                                           15 cm                                     6.09                                0.021
                                                            Limit                                                               614                                  1.63


50% Loading
                                                                  Maximum Permissible Exposure
                    Probe from EUT Side                                      Test Distance                                   E-field                              H-field
                                       Front                                          15 cm                                     6.03                                0.033
                                        Left                                          15 cm                                     6.34                                0.035
                                       Right                                          15 cm                                     6.55                                0.039
                                        Top                                           15 cm                                     6.53                                0.031
                                     Bottom                                           15 cm                                     6.43                                0.028
                                                            Limit                                                               614                                  1.63


1% Loading
                                                                  Maximum Permissible Exposure
                    Probe from EUT Side                                      Test Distance                                   E-field                              H-field
                                       Front                                          15 cm                                     6.33                                0.033
                                        Left                                          15 cm                                     6.77                                 0.04
                                       Right                                          15 cm                                     6.34                                0.033
                                        Top                                           15 cm                                     6.98                                0.037
                                     Bottom                                           15 cm                                     6.93                                0.034
                                                            Limit                                                               614                                  1.63




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                          SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                      f (886-2) 2298-0488                     www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                  Report No.: ER/2018/50050
                                                                                                                                   Page: 5 of 7



Full Loading
                                                                  Maximum Permissible Exposure
                    Probe from EUT Side                                      Test Distance                                   E-field                              H-field
                                       Front                                          20 cm                                     6.12                                 0.03
                                        Left                                          20 cm                                     6.23                                0.026
                                       Right                                          20 cm                                     6.32                                0.033
                                        Top                                           20 cm                                     6.44                                0.029
                                     Bottom                                           20 cm                                     6.54                                0.028
                                                            Limit                                                               614                                  1.63


99% Loading
                                                                  Maximum Permissible Exposure
                    Probe from EUT Side                                      Test Distance                                   E-field                              H-field
                                       Front                                          20 cm                                     6.21                                0.032
                                        Left                                          20 cm                                     6.24                                0.035
                                       Right                                          20 cm                                     6.44                                 0.04
                                        Top                                           20 cm                                     6.45                                0.027
                                     Bottom                                           20 cm                                     6.21                                0.026
                                                            Limit                                                               614                                  1.63


50% Loading
                                                                  Maximum Permissible Exposure
                    Probe from EUT Side                                      Test Distance                                   E-field                              H-field
                                       Front                                          20 cm                                     6.32                                0.021
                                        Left                                          20 cm                                     6.37                                0.032
                                       Right                                          20 cm                                     6.13                                0.023
                                        Top                                           20 cm                                     6.36                                0.021
                                     Bottom                                           20 cm                                     6.44                                0.021
                                                            Limit                                                               614                                  1.63




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                          SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                      f (886-2) 2298-0488                     www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                  Report No.: ER/2018/50050
                                                                                                                                   Page: 6 of 7



1% Loading
                                                                  Maximum Permissible Exposure
                    Probe from EUT Side                                      Test Distance                                   E-field                              H-field
                                       Front                                          20 cm                                     6.12                                0.022
                                        Left                                          20 cm                                     6.03                                0.019
                                       Right                                          20 cm                                     6.22                                0.021
                                        Top                                           20 cm                                     6.12                                0.019
                                     Bottom                                           20 cm                                     6.17                                0.012
                                                            Limit                                                               614                                  1.63




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                          SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號