        RF Exposure Evaluation Report                                              Report No. : FA622001




                   RF Exposure Evaluation Report

               APPLICANT          : ACER INCORPORATED

               EQUIPMENT          : Acer Wireless Power Bank

               BRAND NAME         : Acer

               MODEL NAME         : WPB1

               FCC ID             : HLZWPB1
               STANDARD           : FCC CFR 47 part 1, 1.1307(b) and 1.1310
                                    KDB 680106 D01v02

     We, SPORTON INTERNATIONAL INC., would like to declare that the device has been
     evaluated in accordance with FCC CFR 47 part 1, 1.1307(b) and 1.1310, and pass the limit.
     Without written approval of SPORTON INTERNATIONAL INC., the test report shall not be
     reproduced except in full.




     Reviewed by: Eric Huang / Deputy Manager




         Approved by: Jones Tsai / Manager



                             SPORTON INTERNATIONAL INC.
No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan City, Taiwan (R.O.C.)




SPORTON INTERNATIONAL INC.                                          Page Number        : 1 of 6
TEL : 886-3-327-3456                                                Report Issued Date : Apr. 07, 2016
FAX : 886-3-328-4978                                                Report Version     : Rev. 01
FCC ID : HLZWPB1


            RF Exposure Evaluation Report                                                                                         Report No. : FA622001

                                                         Table of Contents
1. ADMINISTRATION DATA ........................................................................................................................... 4
2. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 4
3. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 5
4. TEST MODE ................................................................................................................................................ 6
5. MEASUREMENT EQUIPMENT................................................................................................................... 6
6. RF EXPOSURE EVALUATION ................................................................................................................... 6
Appendix A. Test Setup Photo
Appendix B. Calibration Certificate




SPORTON INTERNATIONAL INC.                                                                                    Page Number        : 2 of 6
TEL : 886-3-327-3456                                                                                          Report Issued Date : Apr. 07, 2016
FAX : 886-3-328-4978                                                                                          Report Version     : Rev. 01
FCC ID : HLZWPB1


        RF Exposure Evaluation Report                                           Report No. : FA622001


                                        Revision History
  REPORT NO.       VERSION                         DESCRIPTION                     ISSUED DATE

    FA622001        Rev. 01   Initial issue of report                               Apr. 07, 2016




SPORTON INTERNATIONAL INC.                                       Page Number        : 3 of 6
TEL : 886-3-327-3456                                             Report Issued Date : Apr. 07, 2016
FAX : 886-3-328-4978                                             Report Version     : Rev. 01
FCC ID : HLZWPB1


seorron cas. _RF Exposure Evaluation Report                                                               Report No. : FA622001
  1. Administration Data

                                                          Testing Laboratory

  Test Site                            SPORTON INTERNATIONAL INC.
                                          No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei—Shan District, Taoyuan City,
                                       Taiwan (R.O.C.)
  Test Site Location
                                       TEL: +886—3—327—3456
                                       FAX: +886—3—328—4978

                                                               Applicant

 Company Name                         ACER INCORPORATED

 ob                                   BF., No.88, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 22181, Taiwan (R.0.C)


                                                             Manufacturer
 Company Name                         ACER INCORPORATED

 Address                              BF., No.88, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 22181, Taiwan (R.0.C)




  2. Description of Equipment Under Test (EUT)


                                   Acer Wireless Power Bank
                                   Acer
                                   WPBI1
                                   HLZWPBI
                                   110KHz ~ 205 KHz
                                   * ASK
                                   SUN—G—161—01—ROC
                                   SNB8P2743S(SUN—G—161)
                                   Identical Prototype
  ¥                                Mar. 10, 2016
  Remark: The above EUT‘s information was declared by manufacturer. Please refer to the specifications or user‘s manual
  for more detailed description.




  SPORTON INTERNATIONAL INC.                                                              Page Number        : 4 of 6
  TEL : 886—3—327—3456                                                                    Report Issued Date : Apr.07, 2016
  FAX : 886—3—328—4978                                                                    Report Version     : Rev. 01
  FCC ID : HLZWPB1


          RF Exposure Evaluation Report                                                                 Report No. : FA622001
3. RF Exposure Limit Introduction
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radio

frequency(RF) radiation as specified in § 1.1307(b), except in the case of portable devices which shall be evaluated

according to the provisions of § 2.1093 of this chapter.




(1) Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their

employment provided those persons are fully aware of the potential for exposure and can exercise control over their

exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a

location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. The

phrase fully aware in the context of applying these exposure limits means that an exposed person has received written

and/or verbal information fully explaining the potential for RF exposure resulting from his or her employment. With the

exception of transient persons, this phrase also means that an exposed person has received appropriate training

regarding work practices relating to controlling or mitigating his or her exposure. Such training is not required for transient

persons, but they must receive written and/or verbal information and notification (for example, using signs) concerning

their exposure potential and appropriate means available to mitigate their exposure. The phrase exercise control means

that an exposed person is allowed to and knows how to reduce or avoid exposure by administrative or engineering

controls and work practices, such as use of personal protective equipment or time averaging of exposure.

(2) General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in

which persons who are exposed as a consequence of their employment may not be fully aware of the potential for

exposure or cannot exercise control over their exposure.




SPORTON INTERNATIONAL INC.                                                              Page Number        : 5 of 6
TEL : 886-3-327-3456                                                                    Report Issued Date : Apr. 07, 2016
FAX : 886-3-328-4978                                                                    Report Version     : Rev. 01
FCC ID : HLZWPB1


                 RF Exposure Evaluation Report                                                                 Report No. : FA622001
      4. Test Mode
      This device has been tested in the following charging conditions as below:
                      Test Mode                         Test Setup Configuration                  Charging Current Condition
                         TM1                           Test w/ Client Device installed                  < 1% Battery status
                         TM2                           Test w/ Client Device installed                  50% Battery status
                         TM3                           Test w/ Client Device installed              Near 100% Battery status

      Support Equipment:
                    Name                               Equipment Name                            Type Number
           Devant Technologies, Inc          Pond Wireless Charging for Iphone5                     6H70301
                  Apple Inc.                                Iphone5                                     NA


      5. Measurement Equipment
       Instrument                 Manufacturer           Model No.        Serial No.          Freq Rang        Last Cal.         Due Date
Electric and Magnetic field
                               Narda S.T.S / PMM         EHP 200A       160WX41006           9KHz~30MHz      Feb. 02, 2016     Feb. 01, 2017
     Probe-Analyzey



      6. RF Exposure Evaluation
      1.    The equipment under test was placed on a wooden desk inside of shield room. The isotropic field probe was used to
            measure the field strength for 6 EUT surfaces, and during measurement a separation of 10cm is maintained between
            EUT surface and the center of the field probe. The detail setup photo please refer to Appendix A.
      2.    Per KDB 680106 D01v02, for devices designed for typical desktop applications, such a wireless charging pads, RF
            exposure evaluation should be conducted assuming a user separation distance of 10 cm. E and H field strength
            measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from
            all sides and the top of the primary/client pair, with the 10 cm measured from the center. of the probe(s) to the edge of
            the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of
            Section 1.1310: 614 V/m and 1.63 A/m and aggregate leakage fields at 10 cm surrounding the device from all
            simultaneous transmitting coils are demonstrated to be less than 30% of the MPE limit.
               Position                                             E-Field Measurement (V/m)
           (Distance 10cm)          A            B            C           D              E          F            G         30% of limit
                TM1               1.502        0.412        0.339       0.611       0.446         0.441        1.531
                TM2                1.23        0.391        0.331       0.541       0.386         0.438        1.311           184
                TM3               1.096        0.331        0.328       0.326       0.464         0.366        1.15


               Position                                             H-Field Measurement (A/m)
           (Distance 10cm)          A            B            C           D              E          F            G         30% of limit
                TM1               0.0526      0.0522       0.0511      0.0531       0.0591        0.0551      0.0551
                TM2               0.0511      0.0519       0.0519      0.0533       0.0590        0.0562      0.0492          0.489
                TM3               0.0520      0.0515       0.0499      0.0541       0.0584        0.0566      0.0498


      Conclusion:
      The field strength limit refers to Part 1.1310 and the test result of exposure evaluation is compliant with 30%
      of the MPE limit. (E- Field: 184 V/m; H-field: 0.489A/m).



      SPORTON INTERNATIONAL INC.                                                                Page Number        : 6 of 6
      TEL : 886-3-327-3456                                                                      Report Issued Date : Apr. 07, 2016
      FAX : 886-3-328-4978                                                                      Report Version     : Rev. 01
      FCC ID : HLZWPB1



Document Created: 2017-11-23 14:38:43
Document Modified: 2017-11-23 14:38:43

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC