07 sar report part 2.pdf

FCC ID: HLZA6002

RF Exposure Info

Download: PDF
FCCID_2981694

           Compliance Certification Services Inc.
             Date of Issue: April 8, 2016                                                       Report No .: C160323S01-SF

WiFi 802.11b -Body Rear High CH11 ............................................................................................... 2
WIFI 802.11n40 -Body Rear CH54 ..................................................................................................... 3
WIFI 802.11n40-Body Front CH102................................................................................................... 4
WIFI 802.11n40-Body Rear CH151 .................................................................................................... 5




                                                     Page 1 of 5


               Compliance Certification Services Inc.
                Date of Issue: April 8, 2016                        Report No .: C160323S01-SF

Test Laboratory: Compliance Certification Services Inc.             Date: 4/5/2016
WiFi 802.11b -Body Rear High CH11
Communication System: UID 0, IEEE 802.11b (0); Communication System Band: ISM 2.4GHz Band;
Frequency: 2462 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2462 MHz; σ = 1.908 S/m; εr = 51.614; ρ = 1000 kg/m3
Room Ambient Temperature: 22°C; Liquid Temperature: 21.5°C
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)
DASY Configuration:
   • Probe: EX3DV4 - SN3798; ConvF(7.08, 7.08, 7.08); Calibrated: 7/24/2015;
   • Sensor-Surface: 2mm (Mechanical Surface Detection)
   • Electronics: DAE4 Sn1245; Calibrated: 7/22/2015
   • Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP:xxxx
   • DASY52 52.8.8(1222);
   • SEMCAD X Version 14.6.10 (7331)

WiFi/Body Rear High CH11/Area Scan (11x11x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 1.24 W/kg

WiFi/Body Rear High CH11/Zoom Scan (7x7x5)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 0 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 2.61 W/kg
SAR(1 g) = 0.995 W/kg; SAR(10 g) = 0.426 W/kg
Maximum value of SAR (measured) = 1.64 W/kg




            0 dB = 1.64 W/kg = 2.15 dBW/kg




                                               Page 2 of 5


               Compliance Certification Services Inc.
                Date of Issue: April 8, 2016                         Report No .: C160323S01-SF

Test Laboratory: Compliance Certification Services Inc.             Date: 4/5/2016
WIFI 802.11n40 -Body Rear CH54
Communication System: UID 0, IEEE802.11 n40 5G (0); Communication System Band: 5G Band II;
Frequency: 5270 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5270 MHz; σ = 5.32 S/m; εr = 48.337; ρ = 1000 kg/m3
Room Ambient Temperature: 22°C; Liquid Temperature: 21.5°C
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)
DASY Configuration:
   • Probe: EX3DV4 - SN3798; ConvF(4.42, 4.42, 4.42); Calibrated: 7/24/2015;
   • Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   • Electronics: DAE4 Sn1245; Calibrated: 7/22/2015
   • Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP:xxxx
   • DASY52 52.8.8(1222);
   • SEMCAD X Version 14.6.10 (7331)

WIFI/IEEE802.11n40 Body Rear CH54/Area Scan (12x12x1): Measurement grid: dx=10mm,
dy=10mm
Maximum value of SAR (measured) = 2.03 W/kg

WIFI/IEEE802.11n40 Body Rear CH54/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 0.6460 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 4.88 W/kg
SAR(1 g) = 0.975 W/kg; SAR(10 g) = 0.291 W/kg

Maximum value of SAR (measured) = 2.74 W/kg




            0 dB = 2.74 W/kg = 4.38 dBW/kg




                                               Page 3 of 5


               Compliance Certification Services Inc.
                Date of Issue: April 8, 2016                          Report No .: C160323S01-SF

Test Laboratory: Compliance Certification Services Inc.             Date: 4/6/2016
WIFI 802.11n40-Body Front CH102
Communication System: UID 0, IEEE802.11 n40 5G (0); Communication System Band: 5G Band III;
Frequency: 5510 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5510 MHz; σ = 5.489 S/m; εr = 48.114; ρ = 1000 kg/m3
Room Ambient Temperature: 22°C; Liquid Temperature: 21.5°C
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)
DASY Configuration:
   • Probe: EX3DV4 - SN3798; ConvF(4.01, 4.01, 4.01); Calibrated: 7/24/2015;
   • Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   • Electronics: DAE4 Sn1245; Calibrated: 7/22/2015
   • Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP:xxxx
   • DASY52 52.8.8(1222);
   • SEMCAD X Version 14.6.10 (7331)

WIFI/IEEE802.11n40 Body Front CH102/Area Scan (13x13x1): Measurement grid: dx=10mm,
dy=10mm
Maximum value of SAR (measured) = 2.04 W/kg

WIFI/IEEE802.11n40 Body Front CH102/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 0.4960 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 5.53 W/kg
SAR(1 g) = 1.10 W/kg; SAR(10 g) = 0.317 W/kg

Maximum value of SAR (measured) = 3.08 W/kg




            0 dB = 3.08 W/kg = 4.89 dBW/kg




                                               Page 4 of 5


               Compliance Certification Services Inc.
                Date of Issue: April 8, 2016                         Report No .: C160323S01-SF

Test Laboratory: Compliance Certification Services Inc.             Date: 4/6/2016
WIFI 802.11n40-Body Rear CH151
Communication System: UID 0, IEEE802.11 n40 5G (0); Communication System Band: 5G Band IV;
Frequency: 5755 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5755 MHz; σ = 5.83 S/m; εr = 47.252; ρ = 1000 kg/m3
Room Ambient Temperature: 22°C; Liquid Temperature: 21.5°C
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)
DASY Configuration:
   • Probe: EX3DV4 - SN3798; ConvF(4.16, 4.16, 4.16); Calibrated: 7/24/2015;
   • Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   • Electronics: DAE4 Sn1245; Calibrated: 7/22/2015
   • Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP:xxxx
   • DASY52 52.8.8(1222);
   • SEMCAD X Version 14.6.10 (7331)

WIFI/IEEE802.11n40 Body Rear CH151/Area Scan (12x12x1): Measurement grid: dx=10mm,
dy=10mm
Maximum value of SAR (measured) = 1.91 W/kg

WIFI/IEEE802.11n40 Body Rear CH151/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 0.4280 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 6.59 W/kg
SAR(1 g) = 1.06 W/kg; SAR(10 g) = 0.230 W/kg

Maximum value of SAR (measured) = 3.27 W/kg




            0 dB = 3.27 W/kg = 5.15 dBW/kg




                                               Page 5 of 5