SAR_Appendix C

FCC ID: HLZ9560NG

RF Exposure Info

Download: PDF
FCCID_4173014

                                                                                                                                                Report No. :E5/2019/10010
                                                                                                                                                Rev: 01
                                                                                                                                                Page : 1 of 25




                      Appendix C
                      Phantom Description




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                                Report No. :E5/2019/10010
                                                                                                                                                Rev: 01
                                                                                                                                                Page : 2 of 25



                      System Validation from Original Equipment Supplier




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                  hvks                                                     wl
                              Callbfatlon Laboratory of                                  \\\\\\J///        &    Schweizerischer Kalibrierdienst
                              Schmid & Partner                                          i‘a\E—@            c    Service sulsse d‘étalonnage
                                 Engineering AG                                         Tess                    Servizio svizzero di taratura
                              Zeughausstrasse 49, 8004 Zurich, Switzeriand              x;,fn\             5.   swiss Caltbration Service
                                                                                            uhi
                              Acoredited by the Swiss Accrediation Service (GAS)                            Accreditation No.: SCS 0108
                              The Swiss Accreditation Service is one of the signatories to the EA
                              Multilteral Agreement for the recognition of callbration certiicates
                              Glossary:
                              TSL                         tissue simulating liquid
                              ConvF                       sensitivity in TSL / NORM xy,z
                              N/A                         not applicable or not measured
                              Calibration is Performed According to the Following Standards:
                                 a) IEEE Std 1528—2013, "IEEE Recommended Practice for Determining the Peak Spatial—
                                     Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
                                     Communications Devices: Measurement Techniques®, June 2013
                                 b) IEC 62209—1, "Measurement procedure for the assessment of Specific Absorption Rate
                                     (SAR) from hand—held and body—mounted devices used next to the ear (frequency range of
                                     300 MHz to 6 GHz)®, July 2016
                                 c) IEC 62209—2, "Procedure to determine the Specific Absorption Rate (SAR) for wireless
                                     communication devices used in close proximity to the human body (frequency range of 30
                                     MHz to 6 GHz)*, March 2010
                                   d) KDB 865664, "SAR Measurement Requirements for 100 MHz to 6 GHz"

                              Additional Documentation:
                                 e) DASY4/5 System Handbook

                              Methods Applied and Interpretation of Parameters:
                                 * Measurement Conditions: Furtherdetails are available from the Validation Report at the end
                                   of the certificate. All figures stated in the certificate are valid at the frequency indicated.
                                 * Antenna Parameters with TSL: The dipole is mounted with the spacerto position its feed
                                   point exactly below the center marking of the flat phantom section, with the arms oriented
                                   parallel to the body axis.
                                 * Feed Point Impedance and Return Loss: These parameters are measured with the dipole
                                   positioned underthe liquid filled phantom. The impedance stated is transformed from the
                                   measurement at the SMA connector to the feed point. The Return Loss ensures low
                                   reflected power. No uncertainty required.
                                 * Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
                                   No uncertainty required.
                                 * SAR measured: SAR measured at the stated antenna input power.
                                 « SAR normalized: SAR as measured, normalized to an input powerof 1 W at the antenna
                                       connector.
                                   +   SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
                                       nominal SAR result.
                                The reported uncertainty of measurement is stated as the standard uncertainty of measurement
                                multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
                                probability of approximately 95%.




                              Certificate No: D2450V2—727_Apri8                              Page 2 of 8




                                                                                                                                ve
                                                                                                           noeuper sagy rrrranc e rvwi
w emrimemen rraniu on rimes


                            Measurement Conditions
                                  DASY system confiquration, as far as not iven on page 1.
                                    DASY Version                                              DASY5                             v52.10.0
                                    Extrapolation                                  Advanced Extrapolation

                                    Phantom                                         Modular Flat Phantom
                                    Distance Dipole Genter — TSL                              10 mm                            with Spacer
                                    Zoom Scan Resolution                              dx, dy, dz =5 mm

                                    Frequency                                         2450 MHz +1 MHz


                            Head TSL parameters
                              The following parameters and calculations were applied.
                                                                                              Temperature      Permittivity         Conductivity

                                    Nominal Head TSL parameters                                  22.0°C           30.2               1.80 mho/m
                                    Measured Head TSL parameters                              (22.0 0.2) °C    38.3 26 %          1.86 mho/m x 6 %
                                    Head TSL temperature change during test                      <0.5 °C           —                       w

                            SAR result with Head TSL

                                    SAR averaged over 1 cm? (1 g) of Head TSL                  Condition

                                    SAR measured                                       250 mW input power                     18.3 Wikg
                                    SAR for nominal Head TSL parameters                     normalized to 1W       52.1 Wikg = 17.0 % (k=2)

                                    SAR averaged over 10 om° (10 g) of Head TSL                condition
                                    SAR measured                                        250 mW input power                 6.16 Whg
                                    SAR for nominal Head TSL parameters                     normalized to 1W        24.3 Wikg 16.5 % (k=2)

                            Body TSL parameters
                                  The following parameters and calculations were applied.
                                                                                              Temperature      Permittivity         Conductivity

                                    Nominal Body TSL parameters                                  22.0 °C          52.7               1.95 mho/m

                                    Measured Body TSL parameters                              (22.00.2) °C     52.5 26 %          2.01 mho/m 26 %
                                    Body TSL temperature change during test                      <05°C             —                     —

                            SAR result with Body TSL

                                    SAR averaged over 1 em* (1 g) of Body TSL                  Condition
                                    SAR measured                                        250 mW input power                    12.9 Wig
                                    SAR for nominal Body TSL parameters                     normalized to 1W        50.8 Wikg 2 17.0 % (k=2)

                                    SAR averaged over 10 m (10 g) of Body TSL                   condition
                                    SAR measured                                        250 mW input power                    6.00 Wikg
                                    SAR for nominal Body TSL parameters                     normalized to 1W        29.0 Wikg £ 16.5 % (k=2)



                             Crtiicate No: D2450V2—727_Apri8                         Page 3 of 8




                                                                                                                                 h 8e ppensmarrvee w


reemimame paxanieom imes ce | n


                            Appendix (Additional assessments outside the scope of SCS 0108)

                            Antenna Parameters with Head TSL

                                  Impedance, transformed to feed point                                           5520 +2.7 j0

                                  Heturn Loss                                                                       —25.1 dB


                            Antenna Parameters with Body TSL

                                  Impedance, transformed to feed point                                           s120+56j0
                                  Return Loss                                                                     —25.0 0B


                            General Antenna Parameters and Design

                                  Electrical Delay (one direction)                                                  1.149 ns

                            After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

                            The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
                            second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
                            are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
                            "MeasurementConditions® paragraph. The SAR data are not affected by this change. The overal dipole length is stil
                            according to the Standard.
                            No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
                            feedpoint may be damaged.

                            Additional EUT Data

                                   Menufactured by                                                                   SPEAG
                                   Menufactured on                                                              January 09, 2003




                             Certificate No: D2450V2—727_Apr18                       Page 4 of 8




                                                                                                                                   i9+ uppenmarrvee w wuveue


reemimame paxanieom imes ce | n


                          DASY5 Validation Report for Head TSL

                                                                                                             Date: 24.04.2018

                          Test Laboratory: SPEAG, Zurich, Switzerland

                          DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 — SN:727

                          Communication System: UID 0 — CW; Frequency: 2450 MHz
                          Mediumparameters used: {= 2450 MHz; 0 = 1.86 $/m; s = 38.3;      =1000 kg/m?
                          Phantom section: Flat Section
                          Measurement Standard: DASYS (IEEEAEC/ANSI C63.19—2011)

                          DASY52 Configuration:

                              *   Probe: EX3DV4 — SN7349; ConvF(7.88, 7.88, 7.88); Calibrated: 30.12.2017;

                              *   Sensor—Surface: 1.4mm (Mechanical Surface Detection)

                              *   Electronics: DAE4 Sn601; Calibrated: 26.10.2017

                              *   Phantom: Flat Phantom 5.0 (front); Type: QD 000 P50 AA; Serial: 1001

                              *   DASY52 52.10.0(1446); SEMCAD X 14.6.10(7417)


                          Dipole Calibration for Head Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
                          Measurementgrid: dx=5mm, dy=5mm, dz=5mm
                          Reference Value = 116.0 V/m; Power Drift =—0.06 dB
                          Peak SAR (extrapolated) = 26.7 W/kg
                          SAR(I g) = 13.3 W/kg; SAR(1O g) =6.16 W/keg
                          Maximum value of SAR (measured) = 22.0 W/kg


                                  d8
                                  0
                                  5.00
                                  —10.00
                                  —15.00
                                  —20.00
                                  —25.00
                                            0 dB = 22.0 W/kg = 13.42 dBW/ke




                          Certiicate No: D2450V2—727_Apri8                Page 5 of 8




reemmame axanieom imes ce |


                         Impedance Measurement Plot for Head TSL




                                                                                  2s fen zere oerssr2e
                                  EB3 sn      a ucrs          1582020   266000 A79.91 pH      2 450.000 000 nz


                                  bet
                                  c



                                  hy
                                  15°

                                  ma
                                   cne




                                  y
                                  P

                                  ima
                                            Start 2 250.000 a00 Niz                      Stor 2 e5e.000 a00 riz




                         Certiicate No: D2450V2—727_Apr18                 Page 6 of 8




          se nsm mm erve n h nm enving e wervar reuprce eruruimar e inen ermsaniny erveee rarpacr wngy raremaai e raviiau ons en in ues n iy en un cme aue ay
en rememin ocan um m n | + uy ey ccve vers                                6e 6y cougv reu                         vevvmermaggamwen
                                                                                                                  revirimae we nane mevup


                          DASY5 Validation Report for Body TSL

                                                                                                                Date: 24.04.2018

                          Test Laboratory: SPEAG, Zurich, Switzerland

                          DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 — SN:727

                          Communication System: UID 0 — CW; Frequency: 2450 MHz
                          Medium parameters used: {=2450 MHz; a=2.01 $/m; s = 52.5; p= 1000 kg/m}
                          Phantom section: Flat Section
                          Measurement Standard: DASYS (IEEEAEC/ANSI C63.19—2011)

                          DASY52 Configuration:

                                 *    Probe: EX3DV4 — SN7349; ConF(8.01, 8.01, 8.01); Calibrated: 30.12.2017;

                                 *    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

                                 *    Electronics: DAE4 Sn601; Calibrated: 26.10.2017

                                 *    Phantom: Flat Phantom 5.0 (back); Type: QD 000 P50 AA; Serial: 1002

                                 +    DASY52 52.10.0(1446); SEMCAD X 14.6.10(7417)


                          Dipole Calibration for Body Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
                          Measurementgrid: dx=5mm, dy=5mm, dz=5mm
                          Reference Value = 108.4 V/m; Power Drift = —0.07 dB
                          Peak SAR (extrapolated) = 25.5 W/kg
                          SAR(I g) = 12.9 W/kg; SAR(1O g) = 6 W/kg
                          Maximum value of SAR (measured) =21.1 W/kg

                                     d8
                                     0
                                     5.00
                                     —10.00
                                     —15.00
                                     —20.00
                                      —25.00
                                                 0 dB =21.1 W/ke = 13.24 dBW/kg




                              Certificate No: D2450V2—727_Apri8              Page 7 of 6




reemmame axanieom imes ce |


                                                                                                                                                Report No. :E5/2019/10010
                                                                                                                                                Rev: 01
                                                                                                                                                Page : 9 of 25




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


Callbration Laboratory of                                                g. Senvenemereratbierginst
Schmid & Partner                                                            Servieauisse dtamage
  Engineeting AG                                                         5) senie stcie drtrstrs
Zecgnonsanne annootzanchStzenant                y                        . swiss Caltraton Bonice

Aecestedby h Suas Aediion Sevce (9A3)                                     Aecrustnton No: SCS 0108
the is Acceataton Servie i sn atthe sgnatris t t EA
Mmss dgreerint fo the recagno oatbeaion crttcnice
cicw     ‘Auden                                                    Ceritcnsie DSGHzY2—1040_.dunt
CALIBRATION CERTIFICATE
 Om                      psohave=sitoi

 Caismtonroestuelo       GACAL22Ys
                         Calbraton procedure for cipole vaildation kitsbetween 3—6 GiHz



 Catsatinone             June26, 2018

 hi caltadon coritcancumens h neceuynwinalsunsants ic eelce e npacal uit o rmsiamnect )
 Tra measirements uns inuncnnnasnicontcnncn recbayave svan on n oloning ons on e t f h cce
 Mllealtatonshave oncouctn in th cino svonarety wviermenoprne c a 7 ant xm700.
 cameanen Enviment saes it stouo cesc
  temay Srtincs           i«                Ex tuteitc ho3                      soteiint Cattaten
  Femmawe n               sw roarms         ceternt ns rvcesiccnrs              spois
  Povee sanstmzs          s vooone          deage tw ts arrceirm                wporo
  Ponssiror tm20          su iess           ccees arrcesrm                      kore
  Adoner 20 inA           /S taike0..       ontorta trtreniin                   apers
  n mansuncomsnanee       |stusocra/ouar    oonaetiqis errera                   Aoom
  Astoares Pm E2004       au asee           soBeet (e B23s00,Gver)              bow
|ones                     Eves              mosriate oateam Oarn                cce
|
|secuutoy Sinins          n«                Gteck Bs totemss                    sethioe
[Pove maw en seon         s Garenn          tromis inomena ocms                 inroume ctsos onts
|Pove se io siesa         on ussmseres      tromisintowecsertii6                Inteme ctrde Oeiss
| poverssreertBeith       ou wrarosestr     orocisintowestem oi                 Inhemechroc Oetss
 |nt gnem: ns siros       sw rcome          18dhretsintowmecreck Oc             in teactooc Ocia
 |nemets praveeh ersse    sw ussrennies     rnomorineusecreccnm                  nteasecteac Cecss
                          uns                         Auion                      Sqpaten
 Caltamany                Joonkssad                   Tiieisyreswsn
                                                                                         %e~
 Agroves                  xamatokone                  ‘feerncitininoic      /e?é’g

                                                                                inaone onaoin
 Th vatiaton itwl ob reveiced ererin l nevotwiten somonoacowey_
Cenifeal : osaiivz—1040..unta                 Page 1 ts


Calibration Laboratory of                                                   domniesiche Rattwsioat




                                                                      won
Schmid & Parter                                                             Sorvcesumseitionnags
   Engingering AG                                                           Sorvice wiire i testrs
Anapnounstisose d3,004 Rurch, Sntieind                                      is Caloraton #arvce

Aevusta o e SmenAcomldlen mecn (BA5)                                    Acemsiatoe tox SCS 0108
‘To Suen Acrouiaien Servenis onot m stontoin t te EA
MolilnersAgmemnttr e recogniteofcalbradoncenifentes
Glossary:
TSL                    tissue simulating liquid
ConvF                  sensithity in TSL / NORM xiy,z
NA                     not applicable or not measured
Calibration is Performed According to the Following Standards:
    a) IEEE Std 1526—2013, "IEEE Recommended Practice for Determining the Peak Spatial«
       Averaged Specific Absorption Rate (SAR) in the Human Head trom Wireless
       Communications Devices: Measurement Techniques", June 2013
    b) IEG 62209—1, ‘Measurement procedure for tha assassment al Specific Absorption Aate
       (SAR) from hand—held and hody—mounted devices used nex to the ear (fequancy tange of
       200 MHz to 6 GHz)*, July 2016
    0) 12C 62209—2, ‘Procedure to determine the Specific Absoration Rate (SAR) for wirelats
        communieation devices used in close praximity to the human body (frequency range of 30
        MHz to 8 GHz)\, March 2010
    0) KDB 865664, "SAR Measuremant Requirements tor 100 MHz to 5 GHz"

Additional Documentation:
   e) DASY4/5 System Handbook

Methads Applied and Interprotation of Parameters:
    *   Measurement Conditions: Further details are available from the Validation Report at the end
        of the certificate. All figures stated in the certficate are valld at the frequency indicated
    * Antenna Peramaters with TSL: The dipola is mounted wih the spacar to postion its feed
      point exactly below the center marking of the flat phantom section, with the arms oriented
      patallelto the body aws
    * Feed Polnt Impedance and Retun Loss: These parameters are measuired with the dipore
      positioned under the liquid flled phantom, Tha impedance stated is transformed from the
      measurement at tha SMA connector to the feed point, The Return Loss ensures low
      reflected power. No uncertainty required.
    *   Electrical Delay: One—way delay between tha SMA connector and the antenna feed point.
        No uncertainty required
    *   SAR measured: SAR messured at the stated anlenna input power
    * §4A normalized: SAR as measured. normalzed to an input power of 1 W at the antenna
      connector.
    +   SAR for nominal TSL paramaters: The measurad TSL parametars are used to calculae the
        nominal SARt result
  The reported uncertainty of measurementis stated as the standard uncerlainty of measuremant
  multipled by the coverage factor k=2, which for s normal distribution correspands to a coverage
  probabiity of approximately 95%.




Cariieata Ne Deottvieroa0.umta                 Fage 20t 16


Measurement Conditions
   ©ASY system contiuration.astar as not    aven on sage 1
    DASY Version                                          pasys                             vse.ron
    Extrapotation                                 Asvances Extacolaton
    Phantom                                      Modilnr Fit Phaniom ¥5 0
    Distance Dipote Genter— TSL                           10 mm                        with Soacer
    Zoom Scan Resolution                        . 0y » 40 mm de a 1.4 mm       GradedPatio= 14 (Zrecton)
                                                    seoowa> i wie
                                                    $000 Mzs 1 ie
     Frequeney                                      s800 Miizs 1 ie
                                                    seoo Mzs 1 ie
                                                    seoo ie 1 mz

Head TSL parameters at 5200 MHz
   The foloring parameters and caledaions were anpled
                                                             Termperature   Pormitivity         Conductivity
     Nominal Head TSL parameters                                zeo‘c           o                + 88 mam
     Measured Head TL paramaters                             @0202 °c        se1z6s           455 mam6%
     Haad TSL tersperature change during test                  cesc             —
SAR result with Head TSL at 5200 MHz
     SA averaged over 1 cm" (1 gyof Head TSL                  Condtion
     SAR mensures                                      100 mW inout power                 758 Wiho
     SAF or nominal Hoad TSL parameters                  nomalzed o TW          708 We : 190 % (i2)


     SAR averaged over 10 n? (10gof Head TSL                sondition
     SA mensured                                       100 mW input power                 227 whg
     SAFt for nominal Hoad TSL parametors                nomalzed 1W            227 Wie a 108 % (et)




Cenlem No: DsGtevz—1080Junte                       Page s of 10


Head TSL parameters at 5300 MHz
  The folowing paramaters and calcuations wor appled
                                                        Temperatore                     Gonguctivity
    Nominat Head TSL porometers                           z20‘                           476 mham
    Measured Hoad TSL parametors                        @o—on%©          ssore%        icommam=s%
    Hoad TSL temparature change during teat               <os‘c            —                 —
SAR result with Head TSL at 5300 MHz

    SA averaged over 1 om(1 g) of Head TSL                Conditon
    SA measures                                     100 mW inout power            aze wko
    &7 tor nominaHead TSL paramaters                 nermatzed o 1W         san w Th» 10% thea)
    SAR averaged over 10 em" (10 ) of Head TS             coniton
    Sn¥ measured                                    100 mW inout power           230 wio
    BAFt or nomina Head TBL parometers               nomalzed t 1W           22Who x 135 %o t#

Head TSL parameters at 5500 MHz
  ‘The folowing parematers and calcuatons were apaled
                                                        Temperature      Permitivity    CGonguctity
    Nominal Head TSL parometers                           z20‘              se           436 mhom
    Mensured Head TSL parametore                        gaorone          ss7kew        At6mama $s
    Haad TL temparature change during test                <os‘c              —              —
SAR result with Head TSL at 5500 MHz

    SA6t avaraged over 1 em" (1 ) of Hoad TSL             Gonditon
    Sait measures                                   100 mW iout power              3t wo
    SA lonominal Head TSL paremeters                 romaized io 1w          on.t whe a 18.%(te2)
    SAFt avoraged over 10 c(10g) o Head TSL              contion
    SA measured                                     100 mW inout power          2e Who
    SA# tornaminal Hoad TSL paramsters               remaizeato 1w           zewa 19.5%(6e2)




Cerfems No: DSGHa2—1080 hmd                      Page 4 0t 16


Head TSL parameters at 5600 MHz
   The fotowng prrameters and cacitatins were nppled
                                                            Termperature      Permitiaity        Condtuctvity
     NominaHond TSL paromoters                                 ree‘e             as               507 mom
     weasured Head TSL porameters                           zo—02°C            $515%           297 rhome6%
     Head TSL temporature change during tost                   cos‘e              —
SAR result with Head TSL at 5600 MHz
     SAR averaged over 1 on‘ (1 gof Hoad TSL                 Gondtion
     SAR measured                                      100 mW inoutpower                ceum
     SAfor nomnal Hoas TSL peramtors                    nomaizes io tw            ons wig a 1e % ten
     SAR averaged over 10 en‘ (10 u) of Hoad TSL            coniton
     SA measured                                       100 mW nout power                    2as wig
     SA fornominal Heoad TSL paramiters                   nomaiizd to 1W          24‘ Why = 195 % (on)



Head TSL parameters at 5800 MHz
   Te faloring parameters and calculations were aopled
                                                            Temperature       Pormiivity         Conductiviy
     Nominal Head TSL narameters                               ma‘e              sa               527 mom
     Measured Head TSL paromaters                           gez0—02)°o        smee8%           518 maine8%
     Head TSL temperature change during test                  «es‘e                 —
SAR result with Head TSL at 5800 MHz
     SAaveraged over 1 cm" (1 go Haad TSL                   Condtion
     SAmensured                                        100 mW nput pover                sor wiho
     SA fornominal Head TSL paromotors                  nomatzed io TW            sos wig «109 % tor)
     SAR averaged over10 em? (10g)of Hoad TS                  condiion
     SAR mensured                                        100 mW inout power           asoWho
     SAternominal Head TSl paromatere                     normaizedt o 1W         220wa 198 % tor)




Gentieie no: ostheve 1000uns                       Page Satis


Body TSL parameters at 5200 MHz
  The fatoring parametors and ealcsions wore apales.
                                                            Temperature       Pernitiviy       Conduetiviy
     Nominal Body TSL parametors                               zearc             120            550 main
     Mensured Rody TSt parameters                           reosomc            srors%         sasmhomas®
     BodyTSL temperature change during test                   <os‘e               :                c
SAR result with Body TSL at 5200 MHz

     SA averaged over 1 en (1 g} of Body TSL                  Congiton
     SAR measired                                        100 m¥ nput power              730 wig
     Sa tor nominal Body TSL pararmters                   nomatzsa to tw          792 wing « tos % (ea)
     SA avernged over 10 om" (10 g ot Body TSL               condtion
     SAR messired                                    100 mW incut power                 ant Who
     sArtior nomnal Body TSL perametrs                normatzsto 1W               208 Who x 105 % (ee2)

Body TSL parameters at 5300 MHz
   The folowing peremeters and calcuations were apoted
                                                            Temporature Permitivity             Conductiity
     Norminat Body TSL parameters                             mro‘e         mo                   542 mhom
     Mensured Body TSL parameters                           geo—o2°6_|_iss—6%                  $86mtoim=6%
     Bedy TSLtemperature change during test                   <os‘c         —                       —
SAR result with Body TSL at 5300 MHz

     SAR avoraged over 1 o‘ (1 g}ot Body TSL                  Condion
     SR measired                                         100 mW inout pover             770 who
     SA forominl Body TSL paramaters                      normalie to 1W          70. who 198 %002)
     SAR averaged over 10 en(10 g) of Bosy TS                 constton
      Sart measured                                      100 mW inout poner                2 16 wig
      ht lor nominalBady TSl parameters                   nomalzed to TW          218 Who = 108 % t




Coneal No: pottee—1010unte                        Page s ot 16


Body TSL parameters at 5500 MHz
   "The folning parametersand caculatons mere anoled
                                                         Temperature       Pormitivity    Conguetmiy
     Nominal Body TSL parameters                            reove             o            ses main
     Measured Body T9L porameters                        @zo—02°0          «65=5%        St5mhom=8%
     Body TSL temperature change during test               <os‘c                 —
SAR result with Body TSL at 5800 MHz

     SA averaged over 1 en" (t ) of Body TSL              Gonditon
     Sait measured                                   100 minoutpower                w28 Wiho
     Sa¥ttor nominalBody TSt parametors               romaizasto 1w            ane wig a 190 %x)

     SAM averaged over 10 en‘ (10u) of Body TSL            condion
     Saft measired                                   100 mW inout power             220 wig
     Saittor nomnal Bogy TSt parametors               romaizegio 1w            22e w»195 % toor)
Body TSL parameters at 5600 MHz
   "he foloning paramaters ans calcutons were apoted,
                                                          Temperature      Pemnitivity    Conductiviy
     Nominal Body TSL paramaters                             220°c            «as          577 mhoin
     Measured Body TSL porometers                         raosoa‘c         dssa6%        $tomhome$‘%
     BodyTSL temperature change durin test                  <a5°0
SAR result with Body TSL at 5600 MHz

     SAR averagod over1 en (1 g) of Body TSL               Condiion
     SAR measured                                      100 mW nput gower            san who
     3AR lonaminal Body TBL paremeters                  romalznd t 1W          ons Who a 180 % (or)
     SAR averaged aver 10 om" (10 g) of Body TSL            conditon
     SAR measored                                      100 minput power              2z0viig
     SAR for nominalBady TSL paremers                   romatizad i7w          z227 We a 105 % t




Geriicat No: DsGiHev2—1040.Jkuni8                  Page rot 16


Body TSL parameters at 5800 MHz
   The foloning paramatersand calcuations were appled
                                                         Temporature    Permitivity        Conductivity
    Nominal Body TSL parameters                            220°C           182             800 mhaim
    Measured Bocy TSL parameters                         gro 2020       10016 %          828 mhom« 6 %
    Body TSL temperature change during tost                «os‘c

SAR result with Body TSL at 5800 MHz
    SAR averaged over 1 on(1 ) of Bedy TSL                Cendition
    SAR measured                                    100 mW nout power                 773Wiho
    SA for nominal Body TSL parameters                  nomatzed1w          Te Whg a 190 % (cen)

    SAR averaged over 10 em‘ (10 g) of Body TSL         condtion
    SAmeasured                                      100 n inout power            2 18 Who
    SAR or nominal Body TSL parameters               normatzed to 1W        ons Wa 185 % (hen)




Cerifcat No: Dsoitav21040Junte                    Pagst at 16


Appendix (Additional assessments outside the scope of SGS0108)
Antenna Parameters with Head TSL at 5200 MHz

    impaance,transtarmad t s point                       sosq—a0i0
    Aelum Loss                                             —21308
Antenna Parameters with Head TSL at 5300 MHz

    impdanee,transtormed o es pofrt                      s0a0—20i0
    Ratun Loss                                             —so8 ce
Antenna Parameters with Head TSL at 5500 MHz

    impedanoe, vanatormed to foed pone                   soan —a.10
    Rewn Loss                                              —ontco
Antenna Parameters with Head TSL at 5600 MHz

    Impadanee. vanstormad to tood pone                   sean :2010
    Ratum Loss                                             —2asce
Antenna Parameters with Head TSL at 5800 MHz
    Impacance, vanstormed to toed pone                   sn 1090
    Rawm Loss                                             —macs

Antenna Parameters with Body TSL at 5200 MHz

     Impedance, ranstormed tfd point                     «an—77i0
     Astum Lous                                            «m20c0
Antenna Parameters with Body TSL at 5300 MHz
     Impedance,trnstormed to feodpont                     «in 1800
     Aatun Loss                                            —s41 a8
Antenna Parameters with Body TSL at 5500 MHz

     Impedance, vanatormed to foodpoint                   sosn 80
     Raturn Lass                                           —208 08




Genttate No Oscitav2—1010.4uns            Page ot 16


Antenna Parameters with Body TSL at 5600 MHz:

     Impedance. transformed to fond poit                                     srea—2410
     Rawwm Loss                                                                —2608
Antenna Parameters with Body TSL at 5800 MHz
     Imgesance.transtorned tfoed poit                                        ssrn—r3j0
     Rawum Loss                                                               —2000

General Antenna Parameters and Design
    [ eiecment Doitone sreeson)                        |                       T2sns
Aflr longterm use with 100W raciated power, nly a sight warming ol the inole nearth fecdpoincan be mensured
The digole is made o siandard sermig canxia eable The center conductorof th feading ns is drecty connectad t the
seeand armelthe diple, The antenna is thereform shortciruted for DC—signals. On come ofthe dpolos, emal end caps
are adided o thedipole ams in ordertoimprove matching uen loaded according totha postion as expaned in he
‘Measuremant Gonltons* paragrap. The SAR data are notafseted by ths change. The overal ipols lngth s al
according t ho Stndarc
No axconsive force must be apples tthe cigale arma, because hey might bend orthe sadered comnections nearthe
teesilnt may bo damaged
Additional EUT Data

     Manufactured by                                                           sreao
     Manatactured on                                                      Decermber 30. 2005




Conticaie No: DéGrav2.1010_Junta                  Page 10ot 16


DASYS Validation Report for Head TSL
                                                                                         Dare: 2406 2018
TestLaboratory: SPEAG, Zurich, Switrerland
uT: ipole DSGHzY2; Type: DSGHzV2; Serial: DSGHzV2 — SN=1040
Communication System: UID 0 — CW; Frequeney: 5200 MHz, Frequency: 5200 MHz, Erequency: 5500 MHr,
Frequeney: 5600 MHe, Froqueney: 3800 MHz
Medium parameterused: 1
Medium parametersusef
Mediums parametersused: f
Mediunparametersused: f
Mediums parametersused:
Phantom seetion: FatSection
Measurement Standard: DASYS (IEEENECANSI Cé2,10—201 1)
DASYS2 Configuration:
   + Probe: EX3DVZ— SN380B; ComFIS.25, 5.78, 5.78 @ $200 Mitz,
      ConvF($.3, .5 3.8) 3300 MHz. ConvFIS.2, 5.2,5.2) @ 5800 Mz
      Conv(S.08, 5.05, 5.05) @ 5600 MHz. ConyF4.96. 4.96, 496) @ 5800 MHHe: Calibrated: 30.122017
   + SensorSurface: 1 Amm (Mechanical Surface Detection)
   + Electronics: DAE Sn601 (SGHe):Calibrated: 26.10.2017
   +. Phantons Flat Phastom 3. (fongType: QD 000 P50 AA:Serial: 1001
   +   DaS¥2 52.10.1(76)y SEMCAD X 1a6.1 1(70

Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, (=5200 MHz/Zoom Scan, dist=1.4mmm
(BxBxZ)/iCube    Measurement grid: deimm. dy=trom., o=1 Ammn
Reference Value = 7483 Vim: Poner Drif       =—0.09 dB
Peak SAR (extmpolated) = 27.8 Wike
SARCE a) = 7.88 Wikzs SARCLO @ = 227 We
Maximum valueof SAR (measured)         17.7 Whka
Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, f=8300 MHz/Zoom Scan, dist=1—4mm
(BxB7)/Cube0: Measurement grice dusimm, dy=smm, d1 4mm
Reference Valte   7569 Vim; Power D.
Peak SAR (cxtmpolated) 29 8 Wiky
SARC g)     £22 Wike: SARCIO@
Maximum value of SAR (measured)

Dipole Calibration for Head Tissue/?in=100mW, dist=10mm, (=5500 MHz/Zoom Scan, dist=1.Amm
(BxB7V/Cube Measarement grid: dxctmm, dy=trm, de=l Aown
IReference Value       Vim: Poser Drif =—0.02 dB
Peak SAR (extspolated) = 318 Wig
SARCI g = £.4 Wikg: SAR(IO g) = 238 Wikg
Maximum valueof SAR (measured) = 19.3 Why



Gorticate No: DSGHe¥2—1040Junto                     Page 11 ot 18


Dipole Calibration for Head Tissue/Pin=100mW, di 10mm, 1=5600 MHz/Zoom Scan, db
(BxBx7)/Cabe O: Measurement prid: dnc—tmm, y=imm. e 4mm
Reference Value = 76 52 Vim: Power Drit =—0101dB
Peak SAR (extrapolated)   31.9 Why
SARCL i 854 We SAR(TO @ 248 Wige
Maximunvalue of SAR (measured) = 19.8 We
Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, =5800 MHz/Zoom Scan, dist=14mm
(Bxth7)/Cuibe O: Messurement prid: de—tm, ytoim, o1 tm
Reference Value = 73.34 V/m; Power Drift= 0.01 d
Poak SAR (extrapolated) 316 Wike
SARCT ) = 8107 We SAR(IO @0 = 2.3 Wike
Maximum value of SAR (measured) = 19.| Wie


       «n
       a
       5.00
       4200
       18.00
       2400
       a0.00
                  00B = 17.7 Wikg = 1248 dBWWky




Genticats No: DsGHev21080..1inia               Paget2or 1


Impedance Measurement Plot for Head TSL




                                                      3 uo se enc
        gnn oi      i uce          wsoame    y
                                            centine aoetiyn         5 00000 coo ns



        sa
                                   |     ray     y            A
                                                                                      «slsnd
                                                                                           lg

                                   [—_—£
                                      ~~#    —3$                                       pess
                                                                                      «see
                                               7                                      bes t
         w be                eomed sn ge             prmnaspan s omm n nie
                                                                                      orenrers
                                                                                      rmas
         tor                                                                          S—mine ois

                                                                                      ult
                                                                                      tm
         #
                                                                                      usd
                  cane       ar                      on irews
                  Sran s doneo  se me                         Srar c vasiee seo mis




Conticate No: DéGHaN2.1050_Juni8             Page t3 16


DASY5 Validation Report for Body TSL
                                                                                          Dae: 27.06.2018
Test Laboratory: SPEAG, Zurich, Svitzerland
DUT; Dipole DSGHeY2; Type: DSGHzV2; Serial: DSGHzVZ — SN:1040
Communication System: UID 0 — CW; Frequency: 5200 MHz, Frequeney: 5300 MHz, Frequency: 5500 MHr.
Frequeney: 5600 Miz,Frequeney: 5600 MHr
Medium parumeters used
Mediumparameters used
Mediam parameters used: £= 5500 MHiz;=
Mediomparameters wsed:f
Mediom parameters used
Phantomsestion: FacSection
Messurement Sundard: DASYS (IEEENECIANSI Cé2.19—2011)
DASYS2 Configuration:
    + Probe: EX3DV: — SN380B; ConnI$ 28.            m @ sa00 mtte,
        ConvB3.15,5.15, 5.15@ 3300 Mitz,ComsRA.7, 47, 47@ 5800 NK
        Conv B4 68,4 68, 4.69) @ 3600 MHz,ComnFA.53, 4.53,4.53) @ 5800 Mie; Callbrated: 30.12.2017
    + SensonSurface: 1tm (Mechanical Surfice Detection)
    «. Blecironics: DAIK Sn601 (3GHtz; Calioaied: 26.10.2017
    + Piunton: FlatPhanto5.0 (backo; Type: QD 000 PSO AA; Seral: 1002
   +.   pasysn 9.01(0076; 8 MCADX ts.110439)

Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, f=5200 MHz/Zoom Scan, dist= Ldrmm
(BxBxZ)/Cube 0: Measurcment gridedasmm.dy=tmm.de=I Amm
Reference Yalue = 674 Vim: Poner Drit =—0.08 dB
Poak SAR (exrspolated) 28.1 Whke
SARCI a = 7.58 WhkesSARCIO g) =2.11 Whee
Maximum value of SAR (measored) = 17.1 Wikg

Dipole Calibration for Body Tissue/Pin=100mW, dist         U0mm, (=5300 MHzZoom Scan, dist=1—4mm
(BBx7)(Cube 0: Measurement iddao—tmm, d tm                 4mm
Reference Value =67.85 Vim Power Drit =—0.08 dB
Peak SAR (exrapolated) = 286 W
SARCT g)=7.7 Whkis SAR(10 )             6 Why
Maximum value of SAR (measured) = 17.6 Wikg
Dipole Calibration for Body TisuePin=100mW, dist           l0mm, (=5500 MH@Zoom Scan, dist=1Amm
(Bilba7)(Cube 0: Measurement grid: dicstmm, dy=tmm,        um
Reference Value = 69.16 V/m: Pomer Dritt=—0.02 aB
Peak SAR (cxtrpolized) = 134 Whg
SARC 59 = £.25 Wki: SARCTO g) =2.28 Wike
Maximun valse of SAR (measured) = 19.3 Wz


Centfare No: Dsiay2—1040Junte                   Page teat to


                                                                                                                                                Report No. :E5/2019/10010
                                                                                                                                                Rev: 01
                                                                                                                                                Page : 24 of 25




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group


                                                                                                                                                Report No. :E5/2019/10010
                                                                                                                                                Rev: 01
                                                                                                                                                Page : 25 of 25




                                                                                     - End of report -




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for electronic format
documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined
therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The
Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot
be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law.
                            SGS Taiwan Ltd.      No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803/新北市五股區新北產業園區五工路 134 號
             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                                 f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                            Member of SGS Group



Document Created: 2019-03-26 01:41:10
Document Modified: 2019-03-26 01:41:10

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC