                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 1 of 11




                                                        RF EXPOSURE REPORT
                                                                                                   OF
           Applicant:                                              Quanta Computer Inc.
                                                                   No.188, Wenhua 2nd Rd., Guishan Dist., Taoyuan City
                                                                   33377, Taiwan (R.O.C)
           Product Name:                                           All-in-One PC
           Brand Name:                                             HP
           Model No.:                                              TPC-Q065-32
           Model Difference:                                       N/A
           Report Number:                                          E2/2019/80075
           FCC ID                                                  HFSQTA-NZF
           FCC Rule Part                                           Part 2.1091
           Issue Date:                                             Oct. 07, 2019
           Date of Test:                                           Aug. 14, 2019 ~ Sep. 12, 2019
           Date of EUT Received:                                   Aug. 14, 2019
           We hereby certify that:
           The above equipment was tested by SGS Taiwan Ltd. The test data, data evaluation in this
           report is in compliance with FCC Rules Part 2.
           The test results of this report relate only to the tested sample identified in this report.




              Tested By:
                                                    Tom Huang / Engineer




            Approved By:
                                                 John Yeh / Asst. Manager




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 2 of 11




                                                                       Revision History
                              Revision                           Description                               Issue Date                                Remark
                                 Rev.00                             Original.                            Sep. 24, 2019                  Revised By: Yuri Tsai
                                 Rev.01                Updated product name                              Oct. 07, 2019                  Revised By: Yuri Tsai




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 3 of 11




1 MAXIMUM PERMISSIBLE EXPOSURE (MPE)
1.1        Standard Applicable

     According to KDB 680106 D01 RF Exposure Wireless Charging App v03
     RF exposure potential to users and bystanders is expected to vary according to factors inherent to
     the design of individual systems, which generally requires different evaluation considerations to
     show compliance.
     When exposure concerns arise; for example, due to evolving products and operations, RF
     exposure evaluation may be requested under the provisions of Sections 1.1307 (c) and (d) to
     determine compliance. Because of significant variations in design and operating characteristics, the
     procedures required to evaluate RF exposure compliance for wireless power transfer are
     considered according to the exposure potentials of individual implementations
     The RF exposure requirements must be determined in conjunction with the device operating
     characteristics, according to the mobile and portable exposure requirements in Sections 2.1091
     and 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power
     transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF
     exposure compliance needs to be determined with respect to Sections 1.1307 (c) and (d) of the
     FCC rules.

1.2         Limits for Maximum Permissive Exposure (MPE)
     Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in
     Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the
     applicable exposure limits below 100 kHz.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 4 of 11




1.3        The Worst Charging Condition:
                          Ancillary Equipment                                           Charging Condition                                                  Verdict
                                          Load                                                   Full Loading                                                 PASS
                                          Load                                                  99% Loading                                                   PASS
                                          Load                                                  90% Loading                                                   PASS
                                          Load                                                  50% Loading                                                   PASS
                                          Load                                                  10% Loading                                                   PASS
                         Load                         1% Loading                  PASS
         Note: For Wireless Power Consortium Qi specification, a lower operating frequency or
               high duty cycle result in the transfer of a higher amount of power and charging
               current.


1.4        Measurement Procedure:
             For devices designed for typical desktop applications, such a wireless charging pads, RF
             exposure evaluation should be conducted assuming a user separation distance of 10cm, 15
             cm and 20 cm. E and H field strength measurements or numerical modeling may be used to
             demonstrate compliance. Measurements should be made from all sides and the top of the
             primary/client pair, with the 10cm, 15 cm and 20 cm measured from the center of the
             probe(s) to the edge of the device.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 5 of 11




1.5        Measurement Equipment Used:
             EQUIPMENT           MFR                                                         MODEL                        SERIAL                        LAST                CAL DUE.
                TYPE                                                                        NUMBER                       NUMBER                         CAL.
         Broadband Field Merer                                    CMV                        NBM-550                        F-0375                 08/13/2019 08/12/2020

1.6        Test Set-up:




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 6 of 11




1.7 Maximum Permissible Exposure (MPE) Evaluation:
Full Loading
                                                        Maximum Pemissible Exposure
                                           Probe from EUT Side       Test Distance                                                          V/m               A/m
                                                          Front                                               10 cm                         0.95            0.034
                                                          Back                                                10 cm                         0.93            0.028
                                                           Left                                               10 cm                         6.11            0.193
                                                          Right                                               10 cm                         5.54            0.184
                                                           Top                                                10 cm                         0.83           0.0038
                                                        Bottom                                                10 cm                         0.75           0.0035
                                                                               Limit                                                        614             0.815
99% Loading
                                                        Maximum Pemissible Exposure
                                           Probe from EUT Side       Test Distance                                                          V/m               A/m
                                                          Front                                               10 cm                          1.2           0.0021
                                                          Back                                                10 cm                         1.11           0.0015
                                                           Left                                               10 cm                         6.81           0.0199
                                                          Right                                               10 cm                         6.13           0.0191
                                                           Top                                                10 cm                         1.56           0.0027
                                                        Bottom                                                10 cm                         1.43           0.0019
                                                                               Limit                                                        614             0.815
90% Loading
                                                        Maximum Pemissible Exposure
                                           Probe from EUT Side       Test Distance                                                          V/m               A/m
                                                          Front                                               10 cm                         1.13           0.0022
                                                          Back                                                10 cm                          1.1           0.0019
                                                           Left                                               10 cm                         6.06           0.0193
                                                          Right                                               10 cm                         5.94           0.0188
                                                           Top                                                10 cm                         1.47           0.0029
                                                        Bottom                                                10 cm                         1.32           0.0021
                                                                               Limit                                                        614             0.815




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 7 of 11



50% Loading
                                                        Maximum Pemissible Exposure
                                           Probe from EUT Side       Test Distance                                                          V/m               A/m
                                                          Front                                               10 cm                          2.1           0.0033
                                                          Back                                                10 cm                          2.6           0.0073
                                                           Left                                               10 cm                         5.32           0.0137
                                                          Right                                               10 cm                         4.33           0.0127
                                                           Top                                                10 cm                         1.01           0.0022
                                                        Bottom                                                10 cm                         0.84           0.0021
                                                                               Limit                                                        614             0.815
10% Loading
                                                        Maximum Pemissible Exposure
                                           Probe from EUT Side       Test Distance                                                          V/m               A/m
                                                          Front                                               10 cm                         1.44           0.0024
                                                          Back                                                10 cm                         1.51           0.0077
                                                           Left                                               10 cm                         4.91           0.0129
                                                          Right                                               10 cm                         5.11              0.13
                                                           Top                                                10 cm                         1.45           0.0055
                                                        Bottom                                                10 cm                         1.03           0.0045
                                                                               Limit                                                        614             0.815
1% Loading
                                                        Maximum Pemissible Exposure
                                           Probe from EUT Side       Test Distance                                                          V/m               A/m
                                                          Front                                               10 cm                         1.51           0.0021
                                                          Back                                                10 cm                         1.55           0.0073
                                                           Left                                               10 cm                         4.67            0.013
                                                          Right                                               10 cm                         4.83            0.138
                                                           Top                                                10 cm                         1.54           0.0061
                                                        Bottom                                                10 cm                         1.09           0.0053
                                                                               Limit                                                        614             0.815




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 8 of 11



Full Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       15 cm                     0.71          0.019
                                                                Back                                        15 cm                     0.54          0.017
                                                                 Left                                       15 cm                     4.74         0.0133
                                                                Right                                       15 cm                     5.03         0.0145
                                                                 Top                                        15 cm                     0.45         0.0023
                                                              Bottom                                        15 cm                     0.43         0.0021
                                                                                  Limit                                               614           0.815
99% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       15 cm                     1.14         0.0019
                                                                Back                                        15 cm                     1.01         0.0014
                                                                 Left                                       15 cm                     6.54         0.0209
                                                                Right                                       15 cm                     6.09         0.0211
                                                                 Top                                        15 cm                     1.43         0.0023
                                                              Bottom                                        15 cm                     1.26         0.0017
                                                                                  Limit                                               614           0.815
90% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       15 cm                     1.07         0.0014
                                                                Back                                        15 cm                     0.94         0.0012
                                                                 Left                                       15 cm                     4.43         0.0115
                                                                Right                                       15 cm                     4.39           0.01
                                                                 Top                                        15 cm                     0.72         0.0011
                                                              Bottom                                        15 cm                     0.66         0.0013
                                                                                  Limit                                               614           0.815




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 9 of 11



50% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       15 cm                     0.45         0.0014
                                                                Back                                        15 cm                     0.84         0.0024
                                                                 Left                                       15 cm                     3.07         0.0084
                                                                Right                                       15 cm                     3.95         0.0083
                                                                 Top                                        15 cm                     0.47         0.0011
                                                              Bottom                                        15 cm                     0.44         0.0011
                                                                                  Limit                                               614           0.815
10% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       15 cm                     0.87         0.0017
                                                                Back                                        15 cm                     0.88          0.003
                                                                 Left                                       15 cm                     4.13         0.0112
                                                                Right                                       15 cm                     4.91          0.015
                                                                 Top                                        15 cm                     0.47         0.0022
                                                              Bottom                                        15 cm                     0.44         0.0014
                                                                                  Limit                                               614           0.815
1% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       15 cm                     0.88         0.0016
                                                                Back                                        15 cm                     0.91          0.002
                                                                 Left                                       15 cm                     4.23          0.111
                                                                Right                                       15 cm                     4.83          0.013
                                                                 Top                                        15 cm                     0.43         0.0019
                                                              Bottom                                        15 cm                     0.44         0.0013
                                                                                  Limit                                               614           0.815




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 10 of 11



Full Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       20 cm                      0.4        0.0007
                                                                Back                                        20 cm                     0.38        0.0006
                                                                 Left                                       20 cm                     1.28        0.0031
                                                                Right                                       20 cm                     1.23        0.0029
                                                                 Top                                        20 cm                     0.41        0.0011
                                                              Bottom                                        20 cm                     0.39        0.0008
                                                                                  Limit                                               614          0.815
99% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       20 cm                     0.65        0.0007
                                                                Back                                        20 cm                     0.49        0.0004
                                                                 Left                                       20 cm                     1.63        0.0031
                                                                Right                                       20 cm                     1.56        0.0024
                                                                 Top                                        20 cm                     0.46        0.0008
                                                              Bottom                                        20 cm                     0.44        0.0005
                                                                                  Limit                                               614          0.815
90% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       20 cm                     0.67        0.0006
                                                                Back                                        20 cm                     0.57        0.0003
                                                                 Left                                       20 cm                     1.51        0.0026
                                                                Right                                       20 cm                     1.43        0.0023
                                                                 Top                                        20 cm                     0.48        0.0009
                                                              Bottom                                        20 cm                     0.43        0.0006
                                                                                  Limit                                               614          0.815




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group


                                                                                                                                             Report No: E2/2019/80075
                                                                                                                                             Page: 11 of 11



50% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       20 cm                      0.2        0.0009
                                                                Back                                        20 cm                      0.7        0.0011
                                                                 Left                                       20 cm                     0.98        0.0027
                                                                Right                                       20 cm                        1        0.0038
                                                                 Top                                        20 cm                      0.4         0.001
                                                              Bottom                                        20 cm                     0.36         0.002
                                                                                  Limit                                               614          0.815
10% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       20 cm                     0.22        0.0007
                                                                Back                                        20 cm                     0.75        0.0012
                                                                 Left                                       20 cm                     1.56        0.0041
                                                                Right                                       20 cm                     1.01        0.0023
                                                                 Top                                        20 cm                     0.33         0.009
                                                              Bottom                                        20 cm                     0.31         0.003
                                                                                  Limit                                               614          0.815
1% Loading
                                                           Maximum Pemissible Exposure
                                                Probe from EUT Side    Test Distance   V/m                                                           A/m
                                                                Front                                       20 cm                     0.19        0.0009
                                                                Back                                        20 cm                     0.81        0.0011
                                                                 Left                                       20 cm                     1.23        0.0039
                                                                Right                                       20 cm                     0.95        0.0033
                                                                 Top                                        20 cm                     0.31         0.004
                                                              Bottom                                        20 cm                     0.29         0.005
                                                                                  Limit                                               614          0.815




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                 SGS Taiwan Ltd.               No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                f (886-2) 2298-0488                    www.tw.sgs.com
                                                                                                                                                Member of SGS Group



Document Created: 2019-10-09 12:30:14
Document Modified: 2019-10-09 12:30:14

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC