Test Report - 13.56MHz_R02

FCC ID: HFS-M99

Test Report

Download: PDF
FCCID_3211011

                                                               FCC Test Report

                       Report No.: RF160831C13-4

                            FCC ID: HFS-M99

                       Test Model: QTAXU1

                 Received Date: Aug. 31, 2016

                         Test Date: Sep. 05, 2016 ~ Sep. 14, 2016

                     Issued Date: Sep. 21, 2016


                         Applicant: Quanta Computer Inc.

                          Address: No.188, Wenhua 2nd Rd., Guishan Dist., Taoyuan City 33377, Taiwan



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 ( R.O.C )
                  Test Location: No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, Taiwan, R.O.C.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.




Report No.: RF160831C13-4                                            Page No. 1 / 24                                            Report Format Version: 6.1.1


                                                                Table of Contents
Release Control Record .................................................................................................................................. 3
1 Certificate of Conformity ........................................................................................................................... 4
2 Summary of Test Results ........................................................................................................................... 5
    2.1 Measurement Uncertainty ..................................................................................................................... 5
    2.2 Modification Record .............................................................................................................................. 5
3 General Information ................................................................................................................................... 6
    3.1 General Description of EUT .................................................................................................................. 6
    3.2 Description of Test Modes..................................................................................................................... 7
        3.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 7
    3.3 Description of Support Units ................................................................................................................. 8
        3.3.1 Configuration of System under Test ........................................................................................... 8
    3.4 General Description of Applied Standards ............................................................................................ 8
4 Test Types and Results .............................................................................................................................. 9
    4.1 Radiated Emission Measurement ......................................................................................................... 9
        4.1.1 Limits of Radiated Emission Measurement ................................................................................ 9
        4.1.2 Test Instruments ....................................................................................................................... 10
        4.1.3 Test Procedures ......................................................................................................................... 11
        4.1.4 Deviation from Test Standard .................................................................................................... 11
        4.1.5 Test Set Up ............................................................................................................................... 12
        4.1.6 EUT Operating Conditions ........................................................................................................ 12
        4.1.7 Test Results .............................................................................................................................. 13
    4.2 Frequency Stability ............................................................................................................................. 19
        4.2.1 Limits of Frequency Stability Measurement ............................................................................. 19
        4.2.2 Test Setup ................................................................................................................................. 19
        4.2.3 Test Instruments ....................................................................................................................... 19
        4.2.4 Test Procedure ......................................................................................................................... 19
        4.2.5 Deviation fromTest Standard .................................................................................................... 19
        4.2.6 EUT Operating Conditions ........................................................................................................ 19
        4.2.7 Test Result ................................................................................................................................ 20
    4.3 20 dB Bandwidth ................................................................................................................................. 21
        4.3.1 Limits of 20 dB Bandwidth Measurement ................................................................................. 21
        4.3.2 Test Setup ................................................................................................................................. 21
        4.3.3 Test Instruments ....................................................................................................................... 21
        4.3.4 Test Procedures ........................................................................................................................ 21
        4.3.5 Deviation from Test Standard ................................................................................................... 21
        4.3.6 EUT Operating Conditions ........................................................................................................ 21
        4.3.7 Test Results .............................................................................................................................. 22
5 Pictures of Test Arrangements................................................................................................................ 23
Appendix – Information on the Testing Laboratories ................................................................................ 24




Report No.: RF160831C13-4                                         Page No. 2 / 24                                          Report Format Version: 6.1.1


                                           Release Control Record


 Issue No.              Description                                         Date Issued
 RF160831C13-4          Original Release                                    Sep. 21, 2016




Report No.: RF160831C13-4                     Page No. 3 / 24       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Wearable device

        Test Model: QTAXU1

    Sample Status: Engineering Sample

          Applicant: Quanta Computer Inc.

          Test Date: Sep. 05, 2016 ~ Sep. 14, 2016

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.225)
                        47 CFR FCC Part 15, Subpart C (Section 15.215)
                        ANSI C63.10:2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:       Sep. 21, 2016
                                Rona Chen / Specialist




     Approved by :                                              ,   Date:       Sep. 21, 2016
                            Stanley Wu / Assistant Manager




Report No.: RF160831C13-4                     Page No. 4 / 24                        Report Format Version: 6.1.1


2     Summary of Test Results

                             47 CFR FCC Part 15, Subpart C (Section 15.225, 15.215)
    FCC Clause                    Test Item                    Result                    Remarks
                                                                          Without AC power port of the EUT
      15.207                Conducted emission test                N/A
                                                                          EUT consumes DC power
                                                                          Meet the requirement of limit.
                   The field strength of any emissions
    15.225 (a)                                                     Pass   Minimum passing margin is -62.64 dB
                   within the band 13.553-13.567 MHz
                                                                          at 13.561 MHz.
                    The field strength of any emissions
    15.225 (b)     within the bands 13.410-13.553 MHz              Pass   Meet the requirement of limit.
                          and 13.567-13.710 MHz
                    The field strength of any emissions
     15.225 (c)    within the bands 13.110-13.410 MHz              Pass   Meet the requirement of limit.
                          and 13.710-14.010 MHz
                    The field strength of any emissions                   Meet the requirement of limit.
    15.225 (d)           appearing outside of the                  Pass   Minimum passing margin is -15.9 dB at
                        13.110-14.010 MHz band                            31.94 MHz.
    15.225 (e)              The frequency tolerance                Pass   Meet the requirement of limit.
     15.215 (c)                20dB Bandwidth                      Pass   Meet the requirement of limit.
      15.203                 Antenna Requirement                   Pass   No antenna connector is used.


2.1     Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16-4-2:

                                                                                         Expended Uncertainty
                    Measurement                                     Frequency
                                                                                               (k=2) (±)
         Conducted Emissions at mains ports                   150 kHz ~ 30 MHz                    2.44 dB
                                                             30 MHz ~ 200 MHz                     2.93 dB
           Radiated Emissions up to 1 GHz
                                                            200 MHz ~1000 MHz                     2.95 dB
                                                               1 GHz ~ 18 GHz                     2.26 dB
          Radiated Emissions above 1 GHz
                                                              18 GHz ~ 40 GHz                     1.94 dB


2.2     Modification Record

There were no modifications required for compliance.




Report No.: RF160831C13-4                        Page No. 5 / 24                           Report Format Version: 6.1.1


3     General Information
3.1    General Description of EUT

 Product                     Wearable device
 Test Model                  QTAXU1
 Status of EUT               Engineering Sample
 Power Supply Rating         3.85 Vdc (Li-ion battery)
 Modulation Type             ASK
 Operating Frequency         13.56 MHz
 Antenna Type                Loop Antenna
 Accessory Device            Refer to Note
 Data Cable Supplied         Refer to Note
Note:
1. The EUT contains following accessory devices.
          Product              Brand                     Model                   Description
                             WELLTECH
           Battery                               EXGU111K2003       3.85 Vdc, 450 mAh
                            ENERGY INC.
      Wireless Charger          N/A                      QXU1       --
         LTE Chip            Qualcomm                WTR2965        --
        WLAN Chip            Qualcomm               WCN3620         --
         NFC Chip               NXP                PN5482D2EV       --
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF160831C13-4                    Page No. 6 / 24                       Report Format Version: 6.1.1


3.2      Description of Test Modes

One channel was provided to this EUT:
          Channel                   Frequency (MHz)
                   1                        13.56


3.2.1         Test Mode Applicability and Tested Channel Detail

 EUT Configure                                            Applicable To
                                                                                                                 Description
     Mode
                               RE                   PLC                   FS                  EB

          -                     √                    -                    √                     √       -
Where                  RE: Radiated Emission                                     PLC: Power Line Conducted Emission
                       FS: Frequency Stability                                   EB: 20 dB Bandwidth measurement

NOTE: “-”means no effect.


Radiated Emission Test:

      Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
 EUT Configure
                             Available Channel                Tested Channel            Modulation Type                 Axis
     Mode
          -                          1                              1                           ASK                       Y


Frequency Stability:

      This item includes all test value of each mode, but only includes spectrum plot of worst value of each
      mode.
      Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
 EUT Configure
                             Available Channel                Tested Channel            Modulation Type                 Axis
     Mode
          -                          1                              1                           ASK                       Y


20 dB Bandwidth:

      This item includes all test value of each mode, but only includes spectrum plot of worst value of each
      mode.
      Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
 EUT Configure
                             Available Channel                Tested Channel            Modulation Type                 Axis
     Mode
          -                          1                              1                           ASK                       Y


Test Condition:
      Applicable To                 Environmental Conditions                      Input Power                    Tested By
              RE                         25 deg. C, 65 % RH                        3.85 Vdc                      Getaz Yang
              FS                         25 deg. C, 65 % RH                        3.85 Vdc                       Anson Lin
              EB                         25 deg. C, 68 % RH                        3.85 Vdc                       Anson Lin


Report No.: RF160831C13-4                                      Page No. 7 / 24                               Report Format Version: 6.1.1


3.3     Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.


3.3.1    Configuration of System under Test




                                                 EUT

                                        (Powered from battery)



         *Test Table




3.4     General Description of Applied Standards

The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:


FCC Part 15, Subpart C (15.225)
FCC Part 15, Subpart C (15.215)
ANSI C63.10-2013


All test items have been performed and recorded as per the above standards.


NOTE: The EUT has been verified to comply with the requirements of FCC Part 15, Subpart B, Class B (DoC).
         The test report has been issued separately.




Report No.: RF160831C13-4                       Page No. 8 / 24                    Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission Measurement
4.1.1    Limits of Radiated Emission Measurement

The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed 15,848
microvolts/meter at 30 meters.
The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall not exceed the
general radiated emission limits in § 15.209.


            Frequencies                        Field Strength               Measurement Distance
               (MHz)                         (microvolts/meter)                   (meters)
            0.009 ~ 0.490                         2400/F (kHz)                         300
            0.490 ~ 1.705                        24000/F (kHz)                          30
            1.705 ~ 30.0                                30                              30
               30 ~ 88                                 100                               3
              88 ~ 216                                 150                               3
              216 ~ 960                                200                               3
             Above 960                                 500                               3
NOTE:
1. The lower limit shall apply at the transition frequencies.
2.    Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.    For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
      peak field strength of any emission shall not exceed the maximum permitted average limits, specified
      above by more than 20 dB under any condition of modulation.




Report No.: RF160831C13-4                       Page No. 9 / 24                     Report Format Version: 6.1.1


4.1.2    Test Instruments

        Description &                                                                         Due Date of
                                 Model No.            Serial No.   Date of Calibration
        Manaufacturer                                                                         Calibration
Test Receiver
                                  N9038A           MY51210203          Jan. 21, 2015         Jan. 21, 2016
Agilent
Spectrum Analyzer
                                  N9010A           MY52220314          Oct. 23, 2015          Oct. 22, 2016
Agilent
Spectrum Analyzer
                                  FSU43                  101261       Dec. 17, 2015          Dec. 16, 2016
ROHDE & SCHWARZ
BILOG Antenna
                                 VULB9168             9168-472         Jan. 07, 2016         Jan. 06, 2017
SCHWARZBECK
HORN Antenna
                               BBHA 9120 D            9120D-969        Jan. 04, 2016         Jan. 03, 2017
SCHWARZBECK
HORN Antenna
                                BBHA 9170             9170-480         Jan. 08, 2016         Jan. 07, 2017
SCHWARZBECK
Loop Antenna                     EM-6879                  269          Aug. 11, 2016         Aug. 10, 2017
Preamplifier
                               EMC 012645                980115        Dec. 21, 2015         Dec. 20, 2016
EMCI
Preamplifier
                               EMC 184045                980116        Dec. 21, 2015         Dec. 20, 2016
EMCI
Preamplifier
                                EMC 330H                 980112       Dec. 28, 2015          Dec. 27, 2016
EMCI
Power Meter
                                 ML2495A              1232002         Sep. 21, 2015          Sep. 20, 2016
Anritsu
Power Sensor
                                 MA2411B              1207325         Sep. 21, 2015          Sep. 20, 2016
Anritsu
RF signal cable                                       309219/4
                              SUCOFLEX 104                             Oct. 12, 2015          Oct. 11, 2016
HUBER+SUHNNER                                         2950114
RF signal cable
                              SUCOFLEX 104            250130/4         Oct. 12, 2015          Oct. 11, 2016
HUBER+SUHNNER
RF Coaxial Cable
                                   8D-FB          Cable-Ch10-01        Oct. 12, 2015          Oct. 11, 2016
Worken
Software                            E3
                                                          NA                NA                      NA
BV ADT                           6.120103
Antenna Tower
                                 MFA-440H                 NA                NA                      NA
MF
Turn Table
                                MFT-201SS                 NA                NA                      NA
MF
Antenna Tower &Turn
Table Controller                 MF-7802                  NA                NA                      NA
MF


Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
        2. The test was performed in HwaYa Chamber 10.
        3. The horn antenna and preamplifier (model: EMC 184045) are used only for the measurement of
           emission frequency above 1 GHz if tested.
        4. The FCC Site Registration No. is 690701.
        5. The IC Site Registration No. is IC7450F-10.




Report No.: RF160831C13-4                      Page No. 10 / 24                        Report Format Version: 6.1.1


4.1.3   Test Procedures

a.   The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meters
     semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest
     radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   Height of receiving antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
     to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
     find the maximum reading.
e.   The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold
     Mode.
f.   If the emission level of the EUT in peak mode was lower than the limit specified, then testing could be
     stopped and the peak values of the EUT would be reported. Otherwise the emissions would be re-tested
     one by one using peak, quasi-peak or average method as specified and then reported in a data sheet.


NOTE:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
     Quasi-peak detection at frequency below 1 GHz.
2.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and video bandwidth is 3 MHz for
     Peak detection at frequency above 1 GHz.
3.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98 %) or 10 Hz (Duty cycle > 98 %) for Average detection (AV) at frequency above 1 GHz.
4.   All modes of operation were investigated and the worst-case emissions are reported.


4.1.4   Deviation from Test Standard

No deviation.




Report No.: RF160831C13-4                     Page No. 11 / 24                        Report Format Version: 6.1.1


4.1.5   Test Set Up
Frequency range 9k~30MHz:




                                                  3m




Frequency range 30~1000MHz:




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF160831C13-4                       Page No. 12 / 24                           Report Format Version: 6.1.1


4.1.7      Test Results

EUT Test Condition                                             Measurement Detail
Channel                             Channel 1                  Frequency Range         13.553 ~ 13.567 MHz

Input Power                         120 Vac, 60 Hz             Detector Function       Quasi-Peak
Environmental
                                    25 deg. C, 65 % RH         Tested By               Getaz Yang
Conditions




                          Antenna Polarity & Test Distance: Loop Antenna Open at 3M
             Emission Read                                Antenna           Preamp Antenna   Table
Frequency                      Limit  Margin                        Cable
               Level   Level                               Factor           Factor  Height  Angle   Remark
  (MHz)                      (dBuV/m)  (dB)                       Loss (dB)
             (dBuV/m) (dBuV)                               (dB/m)            (dB)    (cm)  (Degree)
  13.561        61.36       64.74        124     -62.64     37.67       0.31   41.36   100        0         Peak

REMARKS:         1. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
                 2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                              – Pre-Amplifier Factor(dB)
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. Above limits have been translated by the formula
The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of field
strength varies as the inverse distance square (40dB per decade of distance)
Example:
13.56 MHz = 15848 uV/m                   30m
           = 84 dBuV/m                   30m
                               2
           = 84+20log(30/3)              3m
           = 124 dBuV/m




Report No.: RF160831C13-4                            Page No. 13 / 24                    Report Format Version: 6.1.1


EUT Test Condition                                            Measurement Detail
Channel                            Channel 1                  Frequency Range         13.553 ~ 13.567 MHz

Input Power                        120 Vac, 60 Hz             Detector Function       Quasi-Peak
Environmental
                                   25 deg. C, 65 % RH         Tested By               Getaz Yang
Conditions




                       Antenna Polarity & Test Distance: Loop Antenna Close at 3M
            Emission Read                                Antenna           Preamp Antenna   Table
Frequency                     Limit  Margin                        Cable
              Level   Level                               Factor           Factor  Height  Angle   Remark
  (MHz)                     (dBuV/m)  (dB)                       Loss (dB)
            (dBuV/m) (dBuV)                               (dB/m)            (dB)    (cm)  (Degree)
   13.56      59.92         63.3        124     -64.08     37.67       0.31   41.36   100       360        Peak

REMARKS:         1. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
                 2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                              – Pre-Amplifier Factor(dB)
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. Above limits have been translated by the formula
The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of field
strength varies as the inverse distance square (40dB per decade of distance)
Example:
13.56 MHz = 15848 uV/m                   30m
           = 84 dBuV/m                   30m
                               2
           = 84+20log(30/3)              3m
           = 124 dBuV/m




Report No.: RF160831C13-4                           Page No. 14 / 24                    Report Format Version: 6.1.1


EUT Test Condition                                           Measurement Detail
Channel                            Channel 1                 Frequency Range          Below 30 MHz

Input Power                        120 Vac, 60 Hz            Detector Function        Quasi-Peak
Environmental
                                   25 deg. C, 65 % RH        Tested By                Getaz Yang
Conditions




                       Antenna Polarity & Test Distance: Loop Antenna Open at 3M
            Emission Read                                Antenna           Preamp Antenna   Table
Frequency                     Limit  Margin                        Cable
              Level   Level                               Factor           Factor  Height  Angle   Remark
  (MHz)                     (dBuV/m)  (dB)                       Loss (dB)
            (dBuV/m) (dBuV)                               (dB/m)            (dB)    (cm)  (Degree)
   27.12       23.7         29.1       69.54    -45.84     35.55       0.38   41.33    100         0        Peak


REMARKS:
             1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
             2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
                                          – Pre-Amplifier Factor (dB)
             3. The other emission levels were very low against the limit.
             4. Margin value = Emission Level – Limit value




Report No.: RF160831C13-4                           Page No. 15 / 24                     Report Format Version: 6.1.1


EUT Test Condition                                             Measurement Detail
Channel                             Channel 1                  Frequency Range         Below 30 MHz

Input Power                         120 Vac, 60 Hz             Detector Function       Quasi-Peak
Environmental
                                    25 deg. C, 65 % RH         Tested By               Getaz Yang
Conditions




                       Antenna Polarity & Test Distance: Loop Antenna Close at 3M
            Emission Read                                 Antenna           Preamp Antenna   Table
Frequency                     Limit  Margin                         Cable
              Level   Level                                Factor           Factor  Height  Angle   Remark
  (MHz)                     (dBuV/m)  (dB)                        Loss (dB)
            (dBuV/m) (dBuV)                                (dB/m)            (dB)    (cm)  (Degree)
   27.12      27.56         32.96       69.54    -41.98     35.55       0.38   41.33   100       360        Peak


REMARKS:
             1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
             2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
                                          – Pre-Amplifier Factor (dB)
             3. The other emission levels were very low against the limit.
             4. Margin value = Emission Level – Limit value




Report No.: RF160831C13-4                            Page No. 16 / 24                    Report Format Version: 6.1.1


 EUT Test Condition                                     Measurement Detail
 Channel                    Channel 1                   Frequency Range      Below 1000 MHz

 Input Power                120 Vac, 60 Hz              Detector Function    Quasi-Peak
 Environmental
                            25 deg. C, 65 % RH          Tested By            Getaz Yang
 Conditions

HORIZONTAL




VERTICAL




Report No.: RF160831C13-4                    Page No. 17 / 24                  Report Format Version: 6.1.1


                               Antenna Polarity & Test Distance: Horizontal at 3 m
            Emissino         Read                          Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level          Level                          Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)        (dBuV)                          (dB/m)       (dB)                   (cm)    (Degree)
  63.95       17.03         36.26        40       -22.97     11.47      0.84      31.54         103       339        Peak
  86.26       15.59          38.2        40       -24.41      8.23      0.94      31.78         136       322        Peak
  143.49       20.6          38.6        43.5     -22.9      12.47      1.16      31.63         120        12        Peak
  153.19      25.06         42.92        43.5     -18.44     12.72      1.11      31.69         104       273        Peak
  174.53      28.39         47.73        43.5     -15.11     11.28      1.16      31.78         120       204        Peak
  304.51       19.8         36.98        46       -26.2      13.06      1.65      31.89         127        77        Peak
                                    Antenna Polarity & Test Distance: Vertical at 3 m
            Emissino         Read                          Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level          Level                          Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)        (dBuV)                          (dB/m)       (dB)                   (cm)    (Degree)
  31.94        24.1         42.32        40       -15.9       12.3      0.59      31.11         132       189        Peak
  64.92        22.9          42.3        40       -17.1      11.35      0.84      31.59         120       189        Peak
  77.53       16.88         38.75        40       -23.12      8.85      0.87      31.59         140       290        Peak
  160.95      26.76         44.84        43.5     -16.74     12.63      1.15      31.86         123        96        Peak
  168.71      30.71         49.43        43.5     -12.79     11.86      1.16      31.74         102       138        Peak
  280.26      19.81         37.68        46       -26.19     12.37      1.58      31.82         138        13        Peak

REMARKS:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
  Margin value = Emission level – Limit value.




Report No.: RF160831C13-4                            Page No. 18 / 24                             Report Format Version: 6.1.1


4.2      Frequency Stability
4.2.1      Limits of Frequency Stability Measurement

The frequency tolerance of the carrier signal shall be maintained within +/- 0.01 % of the operating frequency
over a temperature variation of –20 degrees to 50 degrees C at normal supply voltage, and for a variation in
the primary supply voltage from 85 % to 115% of the rated supply voltage at a temperature of 20 degrees C.


4.2.2      Test Setup

                            Temperature
                            Chamber

      Spectrum Analyzer




                     DC Power Supply




4.2.3      Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.2.4      Test Procedure

a. The EUT was placed inside the environmental test chamber and powered by nominal AC voltage.
b. Turned the EUT on and coupled its output to a spectrum analyzer.
c. Turned the EUT off and set the chamber to the highest temperature specified.
d. Allowed sufficient time (approximately 30 min) for the temperature of the chamber to stabilize then turned
      the EUT on and measured the operating frequency after 2, 5, and 10 minutes.
e. Repeated step 2 and 3 with the temperature chamber set to the lowest temperature.
f.    The test chamber was allowed to stabilize at +20 degree C for a minimum of 30 minutes. The supply
      voltage was then adjusted on the EUT from 85 % to 115 % and the frequency record.


4.2.5      Deviation fromTest Standard

No deviation.


4.2.6      EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF160831C13-4                      Page No. 19 / 24                       Report Format Version: 6.1.1


4.2.7   Test Result

                                   Frequency Stability Versus Temperature

                        0 Minute               2 Minute                5 Minute                 10 Minute
Temp. Power Measured Frequency Measured Frequency Measured Frequency Measured Frequency
      Supply
 (℃)         Frequency  Drift  Frequency   Drift  Frequency   Drift  Frequency   Drift
       (Vdc)
               (MHz)     %       (MHz)      %       (MHz)      %       (MHz)      %

  50     3.85    13.559969 -0.00023 13.559959 -0.00030 13.559953 -0.00035 13.559971 -0.00021
  40     3.85    13.559939 -0.00045 13.559928 -0.00053 13.559941 -0.00044 13.559936 -0.00047
  30     3.85    13.560006   0.00004    13.560015     0.00011     13.560011   0.00008   13.560014      0.00010
  20     3.85    13.559934 -0.00049 13.559949 -0.00038 13.559954 -0.00034 13.559932 -0.00050
  10     3.85    13.559962 -0.00028 13.559966 -0.00025 13.559955 -0.00033 13.559960 -0.00029
   0     3.85    13.559936 -0.00047 13.559929 -0.00052 13.559924 -0.00056 13.559949 -0.00038
  -10    3.85    13.560019   0.00014    13.560037     0.00027     13.560021   0.00015   13.560032      0.00024
  -20    3.85    13.559939 -0.00045 13.559942 -0.00043 13.559951 -0.00036 13.559961 -0.00029
  -30    3.85    13.559958 -0.00031 13.559953 -0.00035 13.559964 -0.00027 13.559969 -0.00023


                                       Frequency Stability Versus Voltage

                   0 Minute            2 Minute            5 Minute           10 Minute
Temp. Power
             Measured Frequency Measured Frequency Measured Frequency Measured Frequency
      Supply
 (℃)         Frequency     Drift Frequency     Drift Frequency     Drift Frequency    Drift
       (Vdc)
               (MHz)        %      (MHz)        %      (MHz)        %      (MHz)        %

          4.2    13.559932 -0.00050 13.559949 -0.00038 13.559951 -0.00036 13.559932 -0.00050
  20     3.85    13.559934 -0.00049 13.559949 -0.00038 13.559954 -0.00034 13.559932 -0.00050
          3.4    13.55993    -0.00052 13.559948 -0.00038 13.559952 -0.00035 13.559932 -0.00050




Report No.: RF160831C13-4                      Page No. 20 / 24                         Report Format Version: 6.1.1


4.3     20 dB Bandwidth
4.3.1    Limits of 20 dB Bandwidth Measurement

The 20 dB bandwidth shall be specified in operating frequency band.


4.3.2    Test Setup

Refer to section 4.1.5.


4.3.3    Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.3.4    Test Procedures

The bandwidth of the fundamental frequency was measured by spectrum analyzer with 1 kHz RBW and 3 kHz
VBW. The 20 dB bandwidth is defined as the total spectrum the power of which is higher than peak power
minus 20 dB.


4.3.5    Deviation from Test Standard

No deviation.


4.3.6    EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF160831C13-4                      Page No. 21 / 24                    Report Format Version: 6.1.1


4.3.7      Test Results

                                                                   Operating Frequency Band
   20 dBc Point (Low)              20 dBc Point (High)                                                     Pass / Fail
                                                                               (MHz)
   13.559294872 MHz                 13.560512821 MHz                       13.553~13.567                         Pass


                                                     Spectrum Plot Of Value
                                                             * RBW     1 kHz     Marker 2 [T1 ]
                                                                 VBW   3 kHz                 44.43 dBµV
            Ref    87 dBµV                Att   5 dB             SWT   20 ms           13.557980769 MHz

                                                                                 Marker 1 [T1 ]
                                                                                             63.46 dBµV
             80
                                                                                       13.559294872 MHz     A
                                                                                 Marker 3 [T1 ]
    1 AP                                                                                     43.98 dBµV
             70
    VIEW
                                                        1                              13.560512821 MHz
                     D1 63.46 dBµV
             60




             50
                                                 2           3
                          D2 43.46 dBµV
             40



                                                                                                           3DB
             30




             20




             10




             0




             -10

            Center   13.56 MHz                          2 kHz/                             Span   20 kHz




   Date: 14.SEP.2016         09:13:09




Report No.: RF160831C13-4                               Page No. 22 / 24                            Report Format Version: 6.1.1


5    Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: RF160831C13-4                      Page No. 23 / 24   Report Format Version: 6.1.1


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and
approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                      Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---