RF Exposure Info

FCC ID: HFS-HA1

RF Exposure Info

Download: PDF
FCCID_477412

FCC ID: HFS-HA1




                    RF EXPOSURE REPORT

                          REPORT NO.: SA930701L11
                           MODEL NO.: IBF-003, IBF-005



                          ACCORDING: FCC Guidelines for Human Exposure
                                     IEEE C95.1


                    APPLICANT: QUANTA COMPUTER INC.

                         ADDRESS:   7F, 116, Hou Kang St., Shih Lin, Taipei,
                                    Taiwan, R.O.C.




                     ISSUED BY: Advance Data Technology Corporation

                LAB LOCATION: No. 19, Hwa Ya 2nd Rd., Wen Hwa Tsuen, Kwei
                              Shan Hsiang, Taoyuan Hsien 333, Taiwan,
                              R.O.C.




Report No: SA930701L11                     1


FCC ID: HFS-HA1




RF Exposure Measurement (Mobile Device)
1. Introduction
In this document, we try to prove the safety of radiation harmfulness to the human body
for our product. The limit for Maximum Permissible Exposure (MPE) specified in FCC
1.1310 is followed. The Gain of the antenna used in this product is measured in a Fully
Anechoic Chamber (FAC) calibrated for antenna measurement in ADT, and also the
maximum total power input to the antenna is measured. Through the Friis transmission
formula and the maximum gain of the antenna, we can calculate the distance, away from
the product, where the limit of MPE is reached.
Although the Friis transmission formula is a far field assumption, the calculated result of
that is an over-prediction for near field power density. We will take that as the worst case
to specify the safety range.


2. RF Exposure Limit

According to FCC 1.1310: The criteria listed in the following table shall be used to
evaluate the environmental impact of human exposure to radio-frequency (RF) radiation
as specified in 1.1307(b)

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

   Frequency        Electric Field    Magnetic Field    Power Density      Average Time
     Range         Strength (V/m)     Strength (A/m)      (mW/cm2)           (minutes)
     (MHz)
                   (A)Limits For Occupational / Control Exposures
   300-1500               …                 …                F/300                6
 1500-100,000             …                 …                  5                  6
             (B)Limits For General Population / Uncontrolled Exposure
   300-1500               …                 …               F/1500                6
 1500-100,000             …                 …                 1.0                30
F = Frequency in MHz




Report No: SA930701L11                       2


FCC ID: HFS-HA1




3. Friis Formula


Friis transmission formula: Pd = (Pout*G) / (4*pi*r2)


where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


If we know the maximum Gain of the antenna and the total power input to the antenna,
through the calculation, we will know the MPE value at distance 20cm.

Ref.: David K. Cheng, Field and Wave Electromagnetics, Second Edition,
      Page 640, Eq. (11-133).



4 EUT Operating condition
The software provided by Manufacturer enabled the EUT to transmit and receive data at
lowest, middle and highest channel individually.



5. Classification

This device is not fixed inside the host equipment; it is connected with host through wire.
So it is easy to be re-located in the place where at least 20cm far away from the body of
the user. Warning statement to the user for keeping at least 20cm or more separation
distance with the antenna should be included in users manual. So, this device is
classified as Mobile Device.




Report No: SA930701L11                       3


FCC ID: HFS-HA1




6 Test Results

6.1 Antenna Gain


The maximum Gain measured in Fully Anechoic Chamber is -2dBi.

6.2 Output Power Into Antenna & RF Exposure Distance:

                                 FIELD
               CHANNEL                                                   LIMIT OF
                              STRENGTH       E.I.R.P    POWER DENSITY
  CHANNEL     FREQUENCY                                         2     POWER DENSITY
                                 AT 3m       (mW)         (mW/cm )
                 (MHz)                                                  (mW/cm2)
                               (dBuV/m)

      0        905.609756        83.02        0.060        0.000012        1.0

     14        915.609756        81.42        0.042        0.000084        1.0

     27        924.390244        80.58        0.034        0.000007        1.0




Report No: SA930701L11                       4



Document Created: 2004-07-29 11:08:50
Document Modified: 2004-07-29 11:08:50