MPE

FCC ID: HFS-C302U

RF Exposure Info

Download: PDF
FCCID_4013079

MAXIMUM PERMISSIBLE EXPOSURE (MPE)

FCC Standard Applicable
     According to §1.1307(b)(1), systems operating under the provisions of this section shall be op-
     erated in a manner that ensure that the public is not exposed to radio frequency energy level in
     excess of the Commission’s guideline.


    This is a Mobile device, the MPE is required.


     According to §1.1310 and §2.1091 RF exposure is calculated.


     Limits for Maximum Permissive Exposure (MPE)


      Frequency Range                            Electric Field    Magnetic Field     Power Density                                                                Averaging Time
           (MHz)                                Strength (V/m)     Strength (A/m)        (mW/cm2)                                                                     (minute)
                                                Limits for General Population/Uncontrolled Exposure
              0.3-1.34                               614                1.63                *(100)                                                                               30
              1.34-30                                824/f             2.19/f             *(180/f2 )                                                                             30
              30-300                                 27.5              0.073                  0.2                                                                                30
             300-1500                                   /                 /                 f/1500                                                                               30
            1500-15000                                  /                 /                   1.0                                                                                30


  f = frequency in MHz
  * = Plane-wave equipment power density




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                          SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                      f (886-2) 2298-0488                     www.tw.sgs.com
                                                                                                                                                      Member of SGS Group


ISED Standard Applicable
     This submittal(s) (test report) is intended to comply with RSS-102 issue 5 Radio frequency Ra-
     diation Exposure requirement.
     This is a Mobile device, the MPE is required.
     Limits for Maximum Permissive Exposure (MPE)

            Frequency                            Electric Field                      Magnetic Field                          Power Density Reference Period
              Range                               (V/m rms)                              Strength                               (W/m2)        (minutes)
              (MHz)                                                                     (A/m rms)
           0.003-10                                     83                                  90                                       -                              Instantaneous*
            0.1-10                                       -                                0.73/ ƒ                                    -                                    6**
            1.1-10                                   87/ ƒ 0.5                               -                                       -                                    6**
             10-20                                    27.46                               0.0728                                     2                                     6
             20-48                                58.07/ ƒ 0.25                        0.1540/ ƒ 0.25                           8.944/ ƒ 0.5                               6
            48-300                                    22.06                              0.05852                                   1.291                                   6
           300-6000                               3.142 ƒ 0.3417                     0.008335 ƒ 0.3417                        0.02619ƒ0.6834                               6
          6000-15000                                   61.4                               0.163                                     10                                     6
         15000-150000                                 61.4                                0.163                                     10                               616000/ ƒ 1.2
        150000-300000                              0.158 ƒ 0.5                       4.21 x 10-4 ƒ 0.5                        6.67 x 10-5 ƒ                          616000/ ƒ 1.2


F = frequency in MHz
* = Based on nerve stimulation (NS).
** = Based on specific absorption rate (SAR)
Maximum Permissible Exposure (MPE) Evaluation


        Prediction of MPE limit at a given distance
        S=PG/4πR2
        Where: S = Power density
                 P = Power input to antenna
                 G = Power gain of the antenna in the direction of interest relative to an isotropic radiator
                 R = Distance to the center of radiation of the antenna




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                          SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                           台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                      f (886-2) 2298-0488                     www.tw.sgs.com
                                                                                                                                                      Member of SGS Group


  Power Density Calculation (Worst Case)
                                                                   FCC                                                                                                             ISED
                                                            Output             Output
          Evaluation Operation                                                          Power                                                                   Power
Operation                                                   Power               Power            Limit  Pass /                                                            Limit                      Pass /
          Frequency Distance                                                           Density                                                                  Density
  Mode                                                       EIRP               EIRP           (mW/cm2) Fail                                                            (W/cm2)                       Fail
             (MHz)     (cm)                                                           (mW/cm2)                                                                 (W/cm2)
                                                            (dBm)              (mW)
 LTE B2            1880.00                  20               24.30             269.15              0.043             1.000             Pass                      0.426              4.526             Pass
 LTE B4            1747.50                  20               24.50             281.84              0.047             1.000             Pass                      0.467              4.305             Pass
LTE B12            714.50                   20               19.41             87.30               0.035             1.000             Pass                      0.345              2.336             Pass



  Note: WWAN and WLAN may not transmit simultaneously, and Bluetooth and WLAN Aux share the
  same antenna path, however BT and WLAN ransmitter can’t be operating at the same time.
  Collocated/coexisted MPE is exclude for MPE evaluation.




  Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
  除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
  This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
  format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
  issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
  instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
  documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
  document is unlawful and offenders may be prosecuted to the fullest extent of the law.
                                            SGS Taiwan Ltd.       No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路 134 號
                             台灣檢驗科技股份有限公司                        t (886-2) 2299-3279                      f (886-2) 2298-0488                     www.tw.sgs.com
                                                                                                                                                        Member of SGS Group



Document Created: 2019-03-28 20:55:31
Document Modified: 2019-03-28 20:55:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC