1 RF Exposure
  1.1Standard Applicable:
According to §1.1307(b)(1), systems operating under the provisions of this section shall be oper-
ated in a manner that ensure that the public is not exposed to radio frequency energy level in ex-
cess of the Commission’s guideline.


This is a Portable device with its physical nature to be used nearby, the distance between radiating
structure and human is less than 20cm.


     As per KDB 447498 D01 4.3.1, The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6
     GHz at test separation distances ≤ 50 mm are determined by:


    [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
     [√f(GHz)] ≤ 3.0 for 1-g Head & Body SAR and ≤ 7.5 for 10-g extremity Hand SAR, where


                                                                      f (GHz) is the RF channel transmit frequency in GHz
                                             Power and distance are rounded to the nearest mW and mm before calculation


  1.2Measurement Result:
      FCC ID: HFS-A85P
      Step 1:

      This is a portable device and the max. output power including tune-up tolerance is
      12.331 (mW), lower than the threshold given and derived as formula given above,
      where
      =12.331(mW)/36.4(mm)*√2.441 (GHz) =0.529< 3.0

                                           Max. output power                                   Max. output power
          Frequency
                                           including tune-up                                   including tune-up                                Distance (mm)                       Result
            (MHz)
                                            tolerance(dBm)                                       tolerance(mW)
               2441                                    10.91                                             12.331                                           36.4                      0.529

As the result of calculation result indicates, the RF exposure generating from given transmitter (trans-
mitter employed digital modulation) can be excluded from SAR measurement, and is deemed com-
pliant with RF exposure as per FCC.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for elec-
tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap-
pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.

 SGS Compliance Certification Services Inc.                   No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan / 新北市五股區五工六路 11 號
                   程智科技股份有限公司                                              t:(886-2) 2299-9720 f:(886-2) 2298-1882 www.sgs.tw www.ccsrf.com
                                                                                                                                          Member of the SGS Group (SGS SA)


                                                                                                                                    Report No.: T190305W01-RP

                                                                                                                                    Page: 2 of 2



The table of quick reference in terms of power threshold




Note that the table present above is the table of quick reference, indexing the level of power
threshold with respect to the corresponding frequency. The value of the index may be deviated,
and therefore, the derivation of exemption based on KDB447498 D01 is used in this test report,
relevantly.




Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and for elec-
tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap-
pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.

 SGS Compliance Certification Services Inc.                   No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan / 新北市五股區五工六路 11 號
                   程智科技股份有限公司                                              t:(886-2) 2299-9720 f:(886-2) 2298-1882 www.sgs.tw www.ccsrf.com
                                                                                                                                          Member of the SGS Group (SGS SA)



Document Created: 2019-03-19 09:11:02
Document Modified: 2019-03-19 09:11:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC