Q ui c k Sta r t G u id e
Cloud-Enabled Outdoor 60 + 5 + 2.4GHz PTP/PTMP
MetroLinq™ 60 LW


1. Unpack the MetroLinq                                                3. Grounding
                       Package Contents
                       ◆ MetroLinq™ 60 LW (ML-60-LW)


                       Tools/Items Required                                                    2
                       ◆ Flat-head screwdriver

                       ◆ Ethernet cables




                                                                                    1

                                                                           1   Ensure the structure on which the unit is to be mounted is
                                                                               properly grounded and in compliance with ETSI ETS 300 253.
                                                                           2   Verify that there is a good electrical connection to a
                                                                               grounding point (no paint or isolating surface treatment).
2. Mount the MetroLinq on a Pole                                               Use the included (M4) screw to attach a grounding wire (not
                                                                               included) to the grounding point on the unit, and then to
                                                                               ground.
                                              2
                                                                               Caution: The earth connection must not be removed
                                                                               unless all supply connections have been disconnected.

                                                                       4. Connect Cables
       1                                                                                                                    2
                                                                                        1

 1    Slide the pole-mount bracket onto the rails on the back of
      the AP until it snaps into its secured position.
 2    Use the included M3 screw to secure the bracket to the AP.



                                                                           1   Connect outdoor-rated Category 5e or better cable to the
                      3                                                        RJ45 port. (The other end of this cable connects to the PoE
                                                                               power injector.)
                                                     4
                                                                           2   Install a 1G SFP transceiver in the SFP port, and then connect
                                                                               fiber optic cabling to the transceiver.
                                                                               The following transceivers are supported:
                                                                               ◆    1000BASE-SX
                                                    4
                           3                                                   ◆    1000BASE-LX

                                                                       5. Connect Power
                                                                       a. Using the PoE Power Injector

 3    Feed the two steel-band clamps through the pole-mount                    3
      bracket mounting points.
 4    Fasten the steel-band clamps around the pole to secure the
      AP to the pole.

                                                                                                             1

                                                                                                   2


                                                                           1   Connect outdoor-rated Category 5e or better cable from the
                                                                               MetroLinq to the POE port on the power injector.



ignitenet.com                                                      – 1 –                                                        E012018-CS-R01


                                                                                                                          Quick Start Guide

 2    Connect Category 5e or better cable from the LAN port on
      the power injector to a LAN switch.
                                                                         7. Connect to the Web User Interface
 3    Connect the power cord to the power injector and to a              To access the web interface, connect a PC directly to the MetroLinq’s
      nearby AC power source (100-240 VAC, 50/60 Hz).                    RJ45 port. In a web browser, enter the default management IP
                                                                         address of 192.168.1.20 to access the web login page.
      Caution: The power injector is designed for indoor use
      only. Never mount the power injector outside with the                                                   Log in to the web interface
      MetroLinq unit.                                                                                         using the default settings:
                                                                                                              ◆    Login Name — root
                                                                                                              ◆    Password — admin123
b. DC Power




                                 1      2
                                                                                Note: To reset the MetroLinq to factory default settings,
                                                                                press and hold down the AP’s Reset button for 10 seconds.

                                                                         8. Complete the Setup Wizard
                                                                                                               Select the country of
                                                                                                               operation for the AP. Setting
                                                                                                               the correct country ensures
                                                                                                               that the radios operate within
      Warning: Before wiring the DC block or connecting power                                                  local regulations specified for
      to the device, ensure that power to the feed lines is turned                                             Wi-Fi networks.
      off at the supply circuit breaker or disconnected from the
      power bus.
 1    Connect the 24 VDC power feed wire to the DC block “+” pin.

 2    Connect the ground/return wire to the DC block “-” pin.            Manage the MetroLinq with the IgniteNet Cloud Controller
                                                                         Go to cloud.ignitenet.com to register your AP.
6. Verify AP Operation                                                   Log in and select Devices from the menu. Click Add Device and
                                                                         enter the MetroLinq serial number and MAC address to register the
                                                                         MetroLinq with your cloud network. The serial number and MAC
                                                                         address can be found on the product packaging or label.
                                                                         Manage the MetroLinq in Stand-Alone Mode
                          4                                              If you select to manage the MetroLinq in stand-alone mode, use the
                                                                         web interface to manually make your configuration changes.
                                                                         For more information on MetroLinq configuration in stand-alone
                           3                                             mode, refer to the User Manual, which can be downloaded from
                                                                         ignitenet.com/support.
                           2

                           1




 1    The power LED should be on amber.
 2    The RJ45 port link/activity LED should be on/blinking green.
 3    When connected, the SFP port link/activity LEDs should also
      be on/blinking green.
 4    During normal operation, the wireless LEDs should be on/
      blinking green.




                                                                     – 2 –


                                                                                                                                        Quick Start Guide

                                                                                    IMPORTANT NOTE:
                                                                                    IC Radiation Exposure Statement:
Safety and Regulatory Information                                                   This equipment complies with IC RSS-102 radiation exposure limits set
                                                                                    forth for an uncontrolled environment. This equipment should be
FCC Class B                                                                         installed and operated with minimum distance 25 cm between the
                                                                                    radiator and your body.
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits        Cet équipement est conforme aux limites d'exposition aux
are designed to provide reasonable protection against harmful                       rayonnements IC établies pour un environnement non contrôlé. Cet
interference in a residential installation. This equipment generates, uses          équipement doit être installé et utilisé avec un minimum de 25 cm de
and can radiate radio frequency energy and, if not installed and used in            distance entre la source de rayonnement et votre corps.
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
                                                                                    CE Statement
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be                 This equipment complies with EU radiation exposure limits set forth for
determined by turning the equipment off and on, the user is                         an uncontrolled environment. This equipment should be installed and
encouraged to try to correct the interference by one of the following               operated with minimum distance 20 cm between the radiator and your
measures:                                                                           body.
                                                                                    All operational modes:
◆    Reorient or relocate the receiving antenna
                                                                                    2.4 GHz: 802.11b, 802.11g, 802.11n (HT20), 802.11n (HT40)
◆    Increase the separation between the equipment and receiver                     5 GHz: 802.11a, 802.11n (HT20), 802.11n (HT40), 802.11ac (VHT20),
                                                                                    802.11ac (VHT40), 802.11ac (VHT80)
◆    Connect the equipment into an outlet on a circuit different from               60 GHz: 802.ad
     that to which the receiver is connected
                                                                                    The frequency and maximum transmitted power limit in EU are listed as
◆    Consult the dealer or an experienced radio/TV technician for help              below:
FCC Caution: Any changes or modifications not expressly approved by                 2412-2472 MHz: 20 dBm
the party responsible for compliance could void the user’s authority to             5500-5700 MHz: 30 dBm
operate this equipment.                                                             57-66 GHz

This device complies with Part 15 of the FCC Rules. Operation is subject                AT   BE   BG   CH     CY    CZ
to the following two conditions: (1) This device may not cause harmful
                                                                                        DE   DK   EE    EL    ES    FI
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.                              FR   HR   HU    IE    IS    IT
                                                                                        LI   LT   LU    LV   MT     NL
For product available in the USA/Canada market, only channel 1–11 can
be operated. Selection of other channels is not possible.                               NO   PL   PT   RO     SE    SI
                                                                                        SK   TR   UK
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
                                                                                    The abbreviations of the countries, as prescribed in above table, where
This equipment complies with FCC radiation exposure limits set forth for            any restrictions on putting into service or any requirements for
an uncontrolled environment. This equipment should be installed and                 authorization of use exist.
operated with minimum distance 23 cm between the radiator and your
body.

Industry Canada
This device complies with Industry Canada license-exempt RSS                        Europe - EU Declaration of Conformity
standard(s). Operation is subject to the following two conditions: (1) this         Hereby, IgniteNet Inc. declares that the radio equipment type:
device may not cause interference, and (2) this device must accept any              MetroLinq™ 60 LW is in compliance with Directive 2014/53/EU and
interference, including interference that may cause undesired operation             Directive 2014/35/EU.
of the device.
                                                                                    The full text of the EU declaration of conformity is available at the
Le présent appareil est conforme aux CNR d'Industrie Canada                         following Internet address: www.ignitenet.com -> support.
applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
                                                                                    NCC Statement (Taiwan)
brouillage radioélectrique subi, même si le brouillage est susceptible              低功率電波輻射性電機管理辦法
d'en compromettre le fonctionnement.
                                                                                    第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或
For product available in the USA/Canada market, only channel 1–11 can               使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。
be operated. Selection of other channels is not possible.
                                                                                    第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經
Pour les produits disponibles aux États-Unis / Canada du marché, seul le
                                                                                    發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前
canal 1 à 11 peuvent être exploités. Sélection d'autres canaux n'est pas            項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍
possible.                                                                           受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。

                                                                                – 3 –


                                                                                                                          Quick Start Guide

電磁波曝露量 MPE 標準值 1mW/cm²,本產品使用時建議應距離人體                                           Regulatory Compliances
20 cm。
                                                                               Radio              EN 300 328 V2.1.1(2016-11)
                                                                                                  EN 301 893 V2.1.1(2017-03)
Warnings and Cautionary Messages
                                                                                                  EN 302 567 V2.1.1 (2017.07)
         Warning: This product does not contain any serviceable user                              47 CFR FCC Part 15.247
         parts.                                                                                   47 CFR FCC Part 15.407
         Warning: Installation and removal of the unit must be carried                            47 CFR FCC Part 15.255
         out by qualified personnel only.
                                                                                                  ICES-003,Issue 6,Class B
         Warning: When connecting this device to a power outlet,
         connect the field ground lead on the tri-pole power plug to a                            RSS-247
         valid earth ground line to prevent electrical hazards.                                   RSS-102 Issue 5
                                                                                                  RSS-Gen Issue 4
         Caution: Wear an anti-static wrist strap or take other suitable                          RSS-210 lssue 9
         measures to prevent electrostatic discharge when handling this
         equipment.                                                            Emissions          EN 301 489-1 V2.2.1 (2017-02)
         Caution: Do not plug a phone jack connector in the RJ-45                                 EN 301 489-17 V3.1.1 (2017-02)
         port. This may damage this device.
                                                                                                  47 CFR FCC Rules and Regulations Part 15
         Caution: Use only twisted-pair cables with RJ-45 connectors                              Subpart B, Class B Digital Device
         that conform to FCC standards.
                                                                                                  Canada Standard ICES-003, Issue 6, Class B




Hardware Specifications
Chassis
                                                                               Manufacturer       Accton Technology Corporation
Size (L x W x H:)         202.7 x 239.8 x 48 mm (7.98 x 9.44 x 1.89
                          inch)                                                                   1, Creation 3rd Rd., Hsinchu Science Park,
                                                                                                  Hsinchu 30077,
Weight                    650 g (1.43 lb)                                                         Taiwan, R.O.C
Temperature               Operating: -30 °C to 55 °C (-22 °F to 131 °F)        US Contact         IgniteNet
                          Storage: -40 °C to 70 °C (-40 °F to 158 °F)                             20 Mason,
                                                                                                  Irvine, CA 92618,
Humidity                  Operating: 10% to 90% (non-condensing)                                  USA
                                                                                                  https://www.ignitenet.com/
Network Interfaces
Ports                     RJ45 Port: 1000BASE-T, passive PoE
                          SFP Port: 1000BASE-X
60 GHz Radio              IEEE 802.11ad
2.4 GHz Radio             IEEE 802.11b/g/n
5 GHz Radio               IEEE 802.11a/n/ac
Radio Frequencies         2412–2472 (FCC, IC, CE, AU, MIC, NCC, SRRC)
                          5150–5250 (FCC, NCC)
                          5470–5725 (CE, MIC, AU)
                          5725–5850 (FCC, IC, NCC, SRRC)
                          58.32–64.80 GHz
Power Supply
PoE                       24 VDC passive PoE
Power Consumption         24 W maximum