1904RSU029-U6-FCC-DXX-Test-Report-NFC

FCC ID: HD5-EDA710

Test Report

Download: PDF
FCCID_4296184

                                       MRT Technology (Suzhou) Co., Ltd         Report No.: 1904RSU029-U6
                                       Phone: +86-512-66308358                  Report Version:        V01
                                       Web: www.mrt-cert.com                    Issue Date:     05-15-2019




                         MEASUREMENT REPORT
         FCC PART 15.225 / RSS-210 NFC 13.56MHz

FCC ID:                         HD5-EDA710
IC:                             1693B-EDA710
APPLICANT:                      Honeywell International Inc
                                Honeywell Safety and Productivity Solutions



Application Type:               Certification
Product:                        Tablet
Model No.:                      EDA71-0
Brand Name:                     Honeywell
FCC Classification:             Part 15 Low Power Communication Device Transmitter
                                (DXX)
FCC Rule Part(s):               Part 15 Subpart C (Section 15.225)
IC Rule(s):                     RSS 210 Issue 9, RSS-GEN Issue 5
Test Procedure(s):              ANSI C63.10-2013
Test Date:                      May 07 ~ 15, 2019



Reviewed By:

                                  ( Jame Yuan )
Approved By:

                                   ( Robin Wu )
The test results relate only to the samples tested.
This equipment has been shown to be capable of compliance with the applicable technical standards as
indicated in the measurement report and was tested in accordance with the measurement procedures specified
in ANSI C63.10. Test results reported herein relate only to the item(s) tested.
The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou)
Co., Ltd.
FCC ID: HD5-EDA710                                                                        Page Number: 1 of 30
IC: 1693B-EDA710


                                                     Report No.: 1904RSU029-U6


                               Revision History

   Report No.        Version      Description      Issue Date        Note

1904RSU029-U6        Rev. 01      Initial Report   05-15-2019        Valid




FCC ID: HD5-EDA710                                         Page Number: 2 of 30
IC: 11693B-EDA710


                                                                                                        Report No.: 1904RSU029-U6


                                                         CONTENTS
Description                                                                                                                             Page
1.   INTRODUCTION ..................................................................................................................... 6

     1.1.      Scope ........................................................................................................................... 6
     1.2.      MRT Test Location ....................................................................................................... 6

2.   PRODUCT INFORMATION ..................................................................................................... 7

     2.1.      Equipment Description.................................................................................................. 7
     2.2.      Test Mode .................................................................................................................... 7
     2.3.      Device Capabilities ....................................................................................................... 7
     2.4.      Test Configuration ........................................................................................................ 7
     2.5.      EMI Suppression Device(s)/Modifications ..................................................................... 8
     2.6.      Labeling Requirements ................................................................................................. 8

3.   DESCRIPTION OF TEST ........................................................................................................ 9

     3.1.      Evaluation Procedure ................................................................................................... 9
     3.2.      AC Line Conducted Emissions ..................................................................................... 9
     3.3.      Radiated Emissions .................................................................................................... 10

4.   ANTENNA REQUIREMENTS .................................................................................................11

5.   TEST EQUIPMENT CALIBRATION DATA ............................................................................ 12

6.   MEASUREMENT UNCERTAINTY ......................................................................................... 13

7.   TEST RESULT ...................................................................................................................... 14

     7.1.      Summary .................................................................................................................... 14
     7.2.      In-band Emission ........................................................................................................ 15
     7.2.1.       Test Limit ................................................................................................................ 15
     7.2.2.       Test Procedure Used .............................................................................................. 15
     7.2.3.       Test Setup............................................................................................................... 16
     7.2.4.       Test Result .............................................................................................................. 17
     7.3.      Out-band Emission ..................................................................................................... 18
     7.3.1.       Test Limit ................................................................................................................ 18
     7.3.2.       Test Procedure Used .............................................................................................. 18
     7.3.3.       Test Setup............................................................................................................... 19
     7.3.4.       Test Result .............................................................................................................. 20
     7.4.      20dB Bandwidth ......................................................................................................... 21
     7.4.1.       Test Limit ................................................................................................................ 21
     7.4.2.       Test Procedure Used .............................................................................................. 21
     7.4.3.       Test Setup............................................................................................................... 21

FCC ID: HD5-EDA710                                                                                               Page Number: 3 of 30
IC: 11693B-EDA710


                                                                                                        Report No.: 1904RSU029-U6


      7.4.4.       Test Result .............................................................................................................. 22
      7.5.      Frequency Tolerence .................................................................................................. 23
      7.5.1.       Test Limit ................................................................................................................ 23
      7.5.2.       Test Procedure Used .............................................................................................. 23
      7.5.3.       Test Setup............................................................................................................... 23
      7.5.4.       Test Result .............................................................................................................. 24
      7.6.      AC Conducted Emissions Measurement..................................................................... 25
      7.6.1.       Test Limit ................................................................................................................ 25
      7.6.2.       Test Setup............................................................................................................... 25
      7.6.3.       Test Result .............................................................................................................. 26

8.    CONCLUSION....................................................................................................................... 28

Appendix A - Test Setup Photograph ......................................................................................... 29

Appendix B - EUT Photograph .................................................................................................... 30




FCC ID: HD5-EDA710                                                                                               Page Number: 4 of 30
IC: 11693B-EDA710


                                                                     Report No.: 1904RSU029-U6


§2.1033 General Information
Applicant:                    Honeywell International Inc
                              Honeywell Safety and Productivity Solutions
Applicant Address:            9680 Old Bailes Road, Fort Mill, SC 29707 United States
Manufacturer:                 Honeywell International Inc
                              Honeywell Safety and Productivity Solutions
Manufacturer Address:         9680 Old Bailes Road, Fort Mill, SC 29707 United States
Test Site:                    MRT Technology (Suzhou) Co., Ltd
Test Site Address:            D8 Building, No.2 Tian’edang Rd., Wuzhong Economic Development
                              Zone, Suzhou, China
Test Device Serial No.:       S/N: 19077B32EF (Radiated Sample)


Test Facility / Accreditations
Measurements were performed at MRT Laboratory located in Tian’edang Rd., Suzhou, China.
 MRT facility is a FCC registered (MRT Reg. No. 893164) test facility with the site description
  report on file and has met all the requirements specified in Section 2.948 of the FCC Rules.
 MRT facility is an IC registered (MRT Reg. No. 11384A-1) test laboratory with the site
  description on file at Industry Canada.
 MRT facility is a VCCI registered (R-20025, G-20034,
  C-20020, T-20020) test laboratory with the site
  description on file at VCCI Council.
 MRT Lab is accredited to ISO 17025 by the American
  Association for Laboratory Accreditation (A2LA) under
  the American Association for Laboratory Accreditation
  Program (A2LA Cert. No. 3628.01) in EMC,
  Telecommunications and Radio testing for FCC,
  Industry Canada, EU and TELEC Rules.




FCC ID: HD5-EDA710                                                          Page Number: 5 of 30
IC: 11693B-EDA710


                                                                          Report No.: 1904RSU029-U6



1.    INTRODUCTION
1.1. Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices
including intentional and/or unintentional radiators for compliance with the technical rules and
regulations of the Federal Communications Commission and the Industry Canada Certification and
Engineering Bureau.



1.2. MRT Test Location
The map below shows the location of the MRT LABORATORY, its proximity to the Taihu Lake.
These measurement tests were conducted at the MRT Technology (Suzhou) Co., Ltd. Facility
located at D8 Building, No.2 Tian’edang Rd., Wuzhong Economic Development Zone, Suzhou,
China. The measurement facility compliant with the test site requirements specified in ANSI
C63.4-2014.




FCC ID: HD5-EDA710                                                              Page Number: 6 of 30
IC: 11693B-EDA710


                                                                        Report No.: 1904RSU029-U6



2.     PRODUCT INFORMATION
2.1. Equipment Description
Product Name:            Tablet
Model No.:               EDA71-0
Brand Name:              Honeywell
Wi-Fi Specification:     802.11a/b/g/n/ac
Bluetooth Version:       V4.2 dual mode
NFC:                     13.56MHz
Accessories
USB Adapter:             Model No.: ADS-12B-06 05010E
                         Input Power: 100 - 240V ~ 50/60Hz, Max. 0.3A
                         Output Power: 5VDC 2.0A
USB Charging Cup:        M/N: EDA70-UC
Battery1#:               Model No.: BAT-EDA50US
                         Capacitance: 15.2Wh, 4000mAh
                         Rated Voltage: 3.8V
Battery2#:               Model No.: EDA70-EXT
                         Capacitance: 33.45Wh, 8850mAh
                         Rated Voltage: 3.78V



2.2. Test Mode
Test Mode
Mode 1: Transmit by NFC



2.3. Device Capabilities
This device contains the following capabilities:
2.4GHz WLAN (DTS), 5GHz WLAN (UNII), Bluetooth v4.2 (DSS, DTS) and NFC.



2.4. Test Configuration
The Tablet was set to continuous transmission. This was performance using manufacturer software
loaded on the terminal to allow for continuous transmission. This device was tested per the guidance
of ANSI C63.10-2013, which is used as the reference of appropriate EUT setup for radiated spurious
emissions testing and AC line conducted testing..




FCC ID: HD5-EDA710                                                            Page Number: 7 of 30
IC: 11693B-EDA710


                                                                           Report No.: 1904RSU029-U6


2.5. EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and/or no modifications were made during testing.



2.6. Labeling Requirements
Per 2.1074 & 15.19; Docket 95-19
The label shall be permanently affixed at a conspicuous location on the device; instruction manual or
pamphlet supplied to the user and be readily visible to the purchaser at the time of purchase.
However, when the device is so small wherein placement of the label with specified statement is not
practical, only the FCC ID must be displayed on the device per Section 15.19(a)(5). Please see
attachment for FCC ID label and label location.


RSP-100 Issue 11 Section 3
The manufacturer, importer or distributor shall meet the labelling requirements set out in this section
for every unit:
(i)    prior to marketing in Canada, for products manufactured in Canada
(ii)   prior to importation into Canada, for imported products
For information regarding the e-labelling option, see Notice 2014-DRS1003. The label for the
certified product represents the manufacturer’s or importer’s compliance with Innovation, Science
and Economic Development Canada’s (ISED) regulatory requirements.
Please see attachment for IC label and label location.




FCC ID: HD5-EDA710                                                              Page Number: 8 of 30
IC: 11693B-EDA710


                                                                           Report No.: 1904RSU029-U6



3.      DESCRIPTION OF TEST
3.1. Evaluation Procedure
The measurement procedures described in the American National Standard for Testing Unlicensed
Wireless Devices (ANSI C63.10-2013) was used in the measurement.
Deviation from measurement procedure…………………………….....................................None



3.2. AC Line Conducted Emissions
The line-conducted facility is located inside an 8'x4'x4' shielded enclosure. A 1m x 2m wooden table
80cm high is placed 40cm away from the vertical wall and 80cm away from the sidewall of the
shielded room. Two 10kHz-30MHz, 50Ω/50uH Line-Impedance Stabilization Networks (LISNs) are
bonded to the shielded room floor. Power to the LISNs is filtered by external high-current
high-insertion loss power line filters. These filters attenuate ambient signal noise from entering the
measurement lines. These filters are also bonded to the shielded enclosure.
The EUT is powered from one LISN and the support equipment is powered from the second LISN.
All interconnecting cables more than 1 meter were shortened to a 1 meter length by non-inductive
bundling (serpentine fashion) and draped over the back edge of the test table. All cables were at
least 40cm above the horizontal reference ground-plane. Power cables for support equipment were
routed down to the second LISN while ensuring that that cables were not draped over the second
LISN.
Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to
warm up to their normal operating condition. The RF output of the LISN was connected to the
receiver and exploratory measurements were made to determine the frequencies producing the
maximum emission from the EUT. The receiver was scanned from 150kHz to 30MHz. The detector
function was set to peak mode for exploratory measurements while the bandwidth of the analyzer
was set to 9kHz. The EUT, support equipment, and interconnecting cables were arranged and
manipulated to maximize each emission. Each emission was also maximized by varying: power lines,
the mode of operation or data exchange speed, or support equipment whichever determined the
worst-case emission. Once the worst case emissions have been identified, the one EUT cable
configuration/arrangement and mode of operation that produced these emissions are used for final
measurements on the same test site. The analyzer is set to CISPR quasi-peak and average
detectors with a 9kHz resolution bandwidth for final measurements.
An extension cord was used to connect to a single LISN which powered by EUT. The extension cord
was calibrated with LISN, the impedance and insertion loss are compliance with the requirements as
stated in ANSI C63.10-2013 at Clause 4.3.




FCC ID: HD5-EDA710                                                               Page Number: 9 of 30
IC: 11693B-EDA710


                                                                            Report No.: 1904RSU029-U6



3.3. Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final
measurements and exploratory measurements, when necessary. The measurement area is
contained within the semi-anechoic chamber which is shielded from any ambient interference. For
measurements above 1GHz absorbers are arranged on the floor between the turn table and the
antenna mast in such a way so as to maximize the reduction of reflections. For measurements below
1GHz, the absorbers are removed. A MF Model 210SS turntable is used for radiated measurement.
It is a continuously rotatable, remote controlled, metallic turntable and 2 meters (6.56 ft.) in diameter.
The turn table is flush with the raised floor of the chamber in order to maintain its function as a
ground plane. An 80cm high PVC support structure is placed on top of the turntable.
For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter
receive antenna height using a broadband antenna from 30MHz up to the upper frequency shown in
15.33(b)(1) depending on the highest frequency generated or used in the device or on which the
device operates or tunes. For frequencies above 1GHz, linearly polarized double ridge horn
antennas were used. For frequencies below 30MHz, a calibrated loop antenna was used. When
exploratory measurements were necessary, they were performed at 1 meter test distance inside the
semi-anechoic chamber using broadband antennas, broadband amplifiers, and spectrum analyzers
to determine the frequencies and modes producing the maximum emissions. Sufficient time for the
EUT, support equipment, and test equipment was allowed in order for them to warm up to their
normal operating condition. The test set-up was placed on top of the 0.8 meter high, 1 x 1.5 meter
table. The EUT, support equipment, and interconnecting cables were arranged and manipulated to
maximize each emission. Appropriate precaution was taken to ensure that all emissions from the
EUT were maximized and investigated. The system configuration, clock speed, mode of operation or
video resolution, if applicable, turntable azimuth, and receive antenna height was noted for each
frequency found.
Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized
broadband and horn antennas. The test setup was configured to the setup that produced the worst
case emissions. The spectrum analyzer was set to investigate all frequencies required for testing to
compare the highest radiated disturbances with respect to the specified limits. The turntable
containing the EUT was rotated through 360 degrees and the height of the receive antenna was
varied 1 to 4 meters and stopped at the azimuth and height producing the maximum emission. Each
emission was maximized by changing the orientation of the EUT through three orthogonal planes
and changing the polarity of the receive antenna, whichever produced the worst-case emissions.
According to 3dB Beam-Width of horn antenna, the horn antenna should be always directed to the
EUT when rising height.




FCC ID: HD5-EDA710                                                                 Page Number: 10 of 30
IC: 11693B-EDA710


                                                                        Report No.: 1904RSU029-U6



4.    ANTENNA REQUIREMENTS
Excerpt from §15.203 of the FCC Rules/Regulations:
“An intentional radiator antenna shall be designed to ensure that no antenna other than that
furnished by the responsible party can be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section.”


⚫    The antenna of the Tablet is permanently attached.
⚫    There are no provisions for connection to an external antenna.


Conclusion:
The unit complies with the requirement of §15.203.




FCC ID: HD5-EDA710                                                             Page Number: 11 of 30
IC: 11693B-EDA710


                                                                            Report No.: 1904RSU029-U6



5.     TEST EQUIPMENT CALIBRATION DATA
Conducted Emissions - SR2

Instrument                  Manufacturer       Type No.     Asset No.        Cali. Interval Cali. Due Date
EMI Test Receiver           R&S                ESR3         MRTSUE06185 1 year              2020/04/15
Two-Line V-Network          R&S                ENV 216      MRTSUE06002 1 year              2019/06/14
Two-Line V-Network          R&S                ENV 216      MRTSUE06003 1 year              2019/06/14
Thermohygrometer            Testo              608-H1       MRTSUE06404 1 year              2019/08/14
Shielding Chamber           MIX-BEP            Chamber-SR2 MRTSUE06214 N/A                  N/A

Radiated Emissions - AC1

Instrument                  Manufacturer       Type No.     Asset No.        Cali. Interval Cali. Due Date
EMI Test Receiver           R&S                ESR7         MRTSUE06001 1 year              2019/08/13
PXA Signal Analyzer         Keysight           9030B        MRTSUE06395 1 year              2019/09/25
Loop Antenna                Schwarzbeck        FMZB 1519    MRTSUE06025 1 year              2019/11/09
Bilog Period Antenna        Schwarzbeck        VULB 9168    MRTSUE06172 1 year              2020/03/31
Broad Band Horn Antenna     Schwarzbeck        BBHA 9120D   MRTSUE06023 1 year              2019/10/19
Broad Band Horn Antenna     Schwarzbeck        BBHA 9170    MRTSUE06024 1 year              2019/12/17
Microwave System Amplifier Agilent             83017A       MRTSUE06076 1 year              2019/11/16
Preamplifier                Schwarzbeck        BBV 9721     MRTSUE06121 1 year              2019/06/12
Thermohygrometer            Testo              608-H1       MRTSUE06403 1 year              2019/08/14
Anechoic Chamber            TDK                Chamber-AC1 MRTSUE06213 1 year               2020/04/30


Radiated Emission - AC2

Instrument                  Manufacturer       Type No.     Asset No.        Cali. Interval Cali. Due Date
Spectrum Analyzer           Keysight           N9038A       MRTSUE06125 1 year              2019/08/13
Loop Antenna                Schwarzbeck        FMZB 1519    MRTSUE06025 1 year              2019/11/09
Bilog Period Antenna        Schwarzbeck        VULB 9162    MRTSUE06022 1 year              2019/10/19
Horn Antenna                Schwarzbeck        BBHA9120D    MRTSUE06171 1 year              2019/11/09
Broad Band Horn Antenna     Schwarzbeck        BBHA 9170    MRTSUE06024 1 year              2019/12/17
Broadband Coaxial
                            Schwarzbeck        BBV 9718     MRTSUE06176 1 year              2019/11/16
Preamplifier
Preamplifier                Schwarzbeck        BBV 9721     MRTSUE06121 1 year              2019/06/12
Temperature/Humidity Meter Minggao             ETH529       MRTSUE06170 1 year              2019/12/13
Anechoic Chamber            RIKEN              Chamber-AC2 MRTSUE06213 1 year               2020/04/30


Software                             Version                            Function
EMI Software                         V3                                 EMI Test Software

FCC ID: HD5-EDA710                                                                 Page Number: 12 of 30
IC: 11693B-EDA710


                                                                        Report No.: 1904RSU029-U6



6.    MEASUREMENT UNCERTAINTY
Where relevant, the following test uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed
at approximately the 95% confidence level using a coverage factor of k = 2.


AC Conducted Emission Measurement - SR2
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     9kHz~150kHz: 3.84dB
     150kHz~30MHz: 3.46dB
Radiated Emission Measurement - AC1
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     Horizontal: 30MHz~300MHz: 4.07dB
                   300MHz~1GHz: 3.63dB
                   1GHz~18GHz: 4.16dB
     Vertical: 30MHz~300MHz: 4.18dB
                   300MHz~1GHz: 3.60dB
                   1GHz~18GHz: 4.76dB
Radiated Emission Measurement - AC2
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     Horizontal:   30MHz~300MHz: 3.75dB
                   300MHz~1GHz: 3.53dB
                   1GHz~18GHz: 4.28dB
     Vertical: 30MHz~300MHz: 3.86dB
                   300MHz~1GHz: 3.53dB
                   1GHz~18GHz: 4.33dB




FCC ID: HD5-EDA710                                                            Page Number: 13 of 30
IC: 11693B-EDA710


                                                                                   Report No.: 1904RSU029-U6



7.     TEST RESULT
7.1. Summary
 FCC Part             RSS       Test Description          Test Limit             Test      Test      Reference
 Section(s)      Section(s)                                                 Condition     Result
                                                   15,848uV/m @ 30m
                                                   13.553 ~ 13.567 MHz
                                                   334uV/m @ 30m
                RSS-210
15.225                          In-Band            13.410 ~ 13.553 MHz
                [B.6]                                                                     Pass     Section 7.2
(a), (b), (c)                   Emission           13.567 ~ 13.710 MHz
                (a), (b), (c)
                                                   106uV/m @ 30m
                                                   13.110 ~ 13.410 MHz
                                                   13.710 ~ 14.010 MHz
                                                   Emissions outside of
                                                   the specified band       Radiated
                RSS-210
                                Out-Band           (13.110~14.010 MHz)
15.225(d)       [B.6]                                                                     Pass     Section 7.3
                                Emission           must meet the radiated
                (d)
                                                   limits detailed in
                                                   15.209
                RSS-Gen         20dB Bandwidth
2.1049                                             N/A                                    Pass     Section 7.4
                [6.7]           99% Bandwidth
                                Frequency
                RSS-210                            ±0.01% of operating
15.225(e)                       Stability                                                 Pass     Section 7.5
                [B.6]                              frequency
                                Tolerance
                                AC Conducted
                RSS-Gen                                                     Line
15.207                          Emissions          < FCC 15.207 limits                    Pass     Section 7.6
                [8.8]                                                       Conducted
                                150kHz - 30MHz
Notes:
1)   All modes of operation and data rates were investigated. For radiated emission test, every axis (X, Y, Z)
     was also verified. The test results shown in the following sections represent the worst case emissions.
2)   The analyzer plots shown in this section were all taken with a correction table loaded into the analyzer.
     The correction table was used to account for the losses of the cables and attenuators used as part of the
     system to connect the EUT to the analyzer at all frequencies of interest.




FCC ID: HD5-EDA710                                                                      Page Number: 14 of 30
IC: 11693B-EDA710


                                                                         Report No.: 1904RSU029-U6



7.2. In-band Emission

7.2.1.Test Limit

               FCC Part 15 Subpart C Paragraph 15.225 & RSS-210 Section [B.6]
           Frequency                           Distance                            Level
             (MHz)                                (m)                             (uV/m)

        13.553 ~13.567                              30                            15,848

        13.410 ~13.553
                                                    30                             334
        13.567 ~13.710

        13.110 ~13.410
                                                    30                             106
        13.710 ~14.010

Note 1: The lower limit shall apply at the transition frequency.
Note 2: Distance refers to the distance in meters between the measuring instrument antenna and the
closed point of any part of the device or system.
Note 3: E field strength (dBuV/m) = 20 log E field strength (uV/m)



7.2.2.Test Procedure Used
The EUT was setup according to ANSI C63.4, 2009 and tested according to ANSI C63.10: 2009 for
compliance to FCC 47CFR 15.247 requirements.
The EUT is placed on a turn table which is 0.8 meter above ground. The turn table is rotated 360
degrees to determine the position of the maximum emission level. The EUT was positioned such that
the distance from antenna to the EUT was 3 meters.
The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. This is
repeated for both horizontal and vertical polarization of the antenna. In order to find the maximum
emission, all of the interface cables were manipulated according to ANSI C63.4:2009 on radiated
measurement.
The EUT should be operate in transmission mode.




FCC ID: HD5-EDA710                                                             Page Number: 15 of 30
IC: 11693B-EDA710


                           Report No.: 1904RSU029-U6



7.2.3.Test Setup
9kHz ~ 30MHz Test Setup:




FCC ID: HD5-EDA710              Page Number: 16 of 30
IC: 11693B-EDA710


                                                                        Report No.: 1904RSU029-U6



7.2.4.Test Result

Test Engineer          David Lv                         Temperature         25°C
Test Time              2019/05/07                       Relative Humidity   56%
Test Mode              Mode1                            Test Site           AC2


 Frequency          Reading          Factor         Measure           Limit (3m)         Margin
                Level(dBuV/m)         (dB)       Level(dBuV/m)        [dBuV/m]            [dB]
Face On
   13.14             17.28           19.85            37.13             80.51            -43.38
   13.50             7.19            19.87            27.06             90.47            -63.41
   13.56             31.33           19.87            51.20             123.99           -72.79
   13.70             9.20            19.87            29.07             90.47            -61.40
   13.98             14.11           19.85            33.96             80.51            -46.55
Face Off
   13.16             8.24            19.86            28.10             80.51            -52.41
   13.50             7.41            19.87            27.28             90.47            -63.19
   13.56             24.47           19.86            44.33             123.99           -79.66
   13.60             7.51            19.86            27.37             90.47            -63.10
   13.89             7.71            19.86            27.57             80.51            -52.94
Note1: All measurements were performed using a loop antenna. The antenna was positioned in two
orthogonal (face on and face off) and the position with the highest emission level was recorded.
Note2: Measurements were tested at 3m and the data was extrapolated to the specified
measurement distance of 30m using the square of an inverse linear extrapolation factor (40
dB/decade) as specified in &15.31(f)(2).
Extrapolation Factor = 40*Log(30/3) = 40 dB
Note3: All measurements were recorded using a EMI test receiver employing a peak detector.




FCC ID: HD5-EDA710                                                              Page Number: 17 of 30
IC: 11693B-EDA710


                                                                      Report No.: 1904RSU029-U6



7.3. Out-band Emission

7.3.1.Test Limit

                FCC Part 15 Subpart C Paragraph 15.209 & RSS-Gen Section 8.9

           Frequency                           Distance                         Level
             (MHz)                                (m)                          (uV/m)

         0.009 - 0.490                              300                     2400/F (kHz)

         0.490 - 1.705                              30                      2400/F (kHz)

           1.705 - 30                               30                           30

             30 - 88                                3                           100

            88 - 216                                3                           150

           216 - 960                                3                           200

           Above 960                                3                           500

Note 1: The lower limit shall apply at the transition frequency.
Note 2: Distance refers to the distance in meters between the measuring instrument antenna and the
closed point of any part of the device or system.
Note 3: E field strength (dBuV/m) = 20 log E field strength (uV/m)



7.3.2.Test Procedure Used
The EUT was tested from 9kHz up to the 1GHz excluding the band 13.110-14.010 MHz. All
measurements were recorded with a spectrum analyzer employing an average detector for
emissions below 30MHz. Above 30MHz a Quasi-peak detector was used. All out-of-band emissions
must not exceed the limits shown as stated per Section 15.209. A loop antenna was used for
searching for emissions below 30MHz.




FCC ID: HD5-EDA710                                                          Page Number: 18 of 30
IC: 11693B-EDA710


                           Report No.: 1904RSU029-U6



7.3.3.Test Setup
9kHz ~ 30MHz Test Setup:




30MHz ~ 1GHz Test Setup:




FCC ID: HD5-EDA710              Page Number: 19 of 30
IC: 11693B-EDA710


                                                                                    Report No.: 1904RSU029-U6



7.3.4.Test Result

Test Engineer            David Lv                              Temperature             25°C
Test Time                2019/05/07                            Relative Humidity       56%
Test Mode                Mode1                                 Test Site               AC2


                                    Out-Band Emission Below 30MHz
 Frequency       Reading            Factor       Measure                Limit       Margin (dB)      Detector
   (MHz)            Level            (dB)             Level           (dBuV/m)
                 (dBuV/m)                        (dBuV/m)
Face On
   27.12            6.38            19.51             25.89            69.54           -43.65          QP
Face Off
   27.12            6.33            19.51             25.84            69.54           -43.7           QP


                                    Out-Band Emission Above 30MHz
 Antenna     Frequency      Reading          Factor       Measure           Limit      Margin (dB)   Detector
                (MHz)        Level            (dB)            Level       (dBuV/m)
                            (dBuV/m)                      (dBuV/m)
    H           39.70         2.22           13.73            15.95         40.00        -24.05         QP
    H           52.80        -0.65           14.79            14.14         40.00        -25.86         QP
    H           101.78       -0.19           13.07            12.89         43.50        -30.62         QP
    H           264.74       -1.16           13.74            12.58         46.00        -33.42         QP
    H           371.44        2.47           15.88            18.35         46.00        -27.66         QP
    H           490.27        2.32           17.83            20.15         46.00        -25.85         QP
    V           35.82        14.47           13.03            27.50         40.00        -12.50         QP
    V           57.65         5.72           14.16            19.88         40.00        -20.12         QP
    V           108.09        0.27           12.88            13.15         43.50        -30.35         QP
    V           159.98        6.67           9.67             16.35         43.50        -27.15         QP
    V           334.10        1.54           15.22            16.76         46.00        -29.24         QP
    V           492.21        0.86           17.88            18.73         46.00        -27.27         QP
Note1: All measurements were performed using a loop antenna. The antenna was positioned in two
orthogonal (face on and face off) and the position with the highest emission level was recorded.
Note2: Measurements were tested at 3m and the data was extrapolated to the specified
measurement distance of 30m using the square of an inverse linear extrapolation factor (40
dB/decade) as specified in &15.31(f)(2).
Extrapolation Factor = 40*Log(30/3) = 40 dB
Note3: All measurements were recorded using a EMI test receiver employing a peak detector.
FCC ID: HD5-EDA710                                                                       Page Number: 20 of 30
IC: 11693B-EDA710


                                                                    Report No.: 1904RSU029-U6



7.4. 20dB Bandwidth

7.4.1.Test Limit
N/A



7.4.2.Test Procedure Used
The 20dB bandwidth is measured with a spectrum analyzer connected via a receive antenna placed
near the EUT while the EUT is operating in transmission mode.



7.4.3.Test Setup




FCC ID: HD5-EDA710                                                       Page Number: 21 of 30
IC: 11693B-EDA710


                                                                      Report No.: 1904RSU029-U6



7.4.4.Test Result

Test Engineer           David Lv                      Temperature         25°C
Test Time               2019/05/15                    Relative Humidity   56%
Test Mode               Mode1                         Test Site           AC2


            Frequency                20dB Occupied Bandwidth        99% Occupied Bandwidth
             (MHz)                            (kHz)                             (kHz)
              13.56                          114.03                          134.59


            20dB Occupied Bandwidth                          99% Occupied Bandwidth




FCC ID: HD5-EDA710                                                         Page Number: 22 of 30
IC: 11693B-EDA710


                                                                         Report No.: 1904RSU029-U6



7.5. Frequency Tolerence

7.5.1.Test Limit
The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating
frequency.



7.5.2.Test Procedure Used
The equipment under test was connected to an external AC or DC power supply and input rated
voltage. RF output was connected to a frequency counter or spectrum analyzer via feed through
attenuators. The EUT was placed inside the temperature chamber. Set the spectrum analyzer RBW
low enough to obtain the desired frequency resolution and measure EUT 20°C operating frequency
as reference frequency. Turn EUT off and set the chamber temperature to highest. After the
temperature stabilized for approximately 30 minutes recorded the frequency. Repeat step measure
with 10°C decreased per stage until the lowest temperature reached.



7.5.3.Test Setup




FCC ID: HD5-EDA710                                                             Page Number: 23 of 30
IC: 11693B-EDA710


                                                                       Report No.: 1904RSU029-U6



 7.5.4.Test Result

Test Engineer           Snake Ni                      Temperature           25°C
Test Time               2019/05/07                    Relative Humidity     56%
Test Mode               Mode1                         Test Site             AC1


Operating Frequency: 13.56MHz
Reference Voltage: 3.8Vdc
Deviation Limit: +/- 0.01% = 1356Hz
    Voltage          Power         TEMP       FREQ.               FREQ. Dev.          Deviation
      (%)         Battery          (°C)        (Hz)                  (Hz)                (%)
                                   -20      13,559,537               -463             -0.003414
                                   -10      13,559,687               -313             -0.002308
                                     0      13,559,053               -947             -0.006984
                                   +10      13,560,556               556              0.004100
     100%            3.80
                                +20 (Ref)   13,560,750               750              0.005531
                                   +30      13,560,762               762              0.005619
                                   +40      13,560,765               765              0.005642
                                   +50      13,560,771               771              0.005686
     115%            4.37          + 20     13,560,748               748              0.005516
      85%            3.23          + 20     13,560,691               691              0.005096




FCC ID: HD5-EDA710                                                             Page Number: 24 of 30
IC: 11693B-EDA710


                                                                         Report No.: 1904RSU029-U6



 7.6. AC Conducted Emissions Measurement

 7.6.1.Test Limit

                 FCC Part 15 Subpart C Paragraph 15.207 & RSS-Gen Section 8.8

           Frequency                              QP                               AV
             (MHz)                              (dBuV)                           (dBuV)

           0.15 - 0.50                          66 - 56                          56 - 46

            0.50 - 5.0                             56                               46

             5.0 - 30                              60                               50

Note 1: The lower limit shall apply at the transition frequencies.
Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to
0.5MHz.



 7.6.2.Test Setup




FCC ID: HD5-EDA710                                                              Page Number: 25 of 30
IC: 11693B-EDA710


                                                                                 Report No.: 1904RSU029-U6



7.6.3.Test Result
Site: SR2                                              Time: 2019/05/07 - 15:45
Limit: FCC_Part15.207_CE_AC Power                      Engineer: Liz Yuan
Probe: ENV216_101683_Filter On                         Polarity: Line
EUT: Tablet                                            Power: AC 120V/60Hz
Test Mode: Mode 1




No   Flag     Mark   Frequency   Measure     Reading     Over Limit     Limit        Factor     Type
                     (MHz)       Level       Level       (dB)           (dBuV)       (dB)
                                 (dBuV)      (dBuV)
1                    0.158       37.585      27.274      -27.983        65.568       10.311     QP
2                    0.158       16.959      6.648       -38.609        55.568       10.311     AV
3                    0.206       31.255      21.274      -32.110        63.365       9.981      QP
4                    0.206       12.364      2.383       -41.001        53.365       9.981      AV
5                    0.394       22.469      12.389      -35.510        57.979       10.080     QP
6                    0.394       12.079      1.999       -35.900        47.979       10.080     AV
7                    0.502       33.857      23.700      -22.143        56.000       10.157     QP
8                    0.502       25.257      15.100      -20.743        46.000       10.157     AV
9             *      13.560      44.058      34.000      -15.942        60.000       10.058     QP
10                   13.560      27.558      17.500      -22.442        50.000       10.058     AV
11                   17.818      26.444      16.350      -33.556        60.000       10.094     QP
12                   17.818      13.320      3.226       -36.680        50.000       10.094     AV
Note 1: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).
Note 2: 13.56MHz is NFC working frequency.

FCC ID: HD5-EDA710                                                                    Page Number: 26 of 30
IC: 11693B-EDA710


                                                                                Report No.: 1904RSU029-U6




Site: SR2                                              Time: 2019/05/07 - 15:50
Limit: FCC_Part15.207_CE_AC Power                      Engineer: Liz Yuan
Probe: ENV216_101683_Filter On                         Polarity: Neutral
EUT: Tablet                                            Power: AC 120V/60Hz
Test Mode: Mode 1




No   Flag     Mark   Frequency   Measure     Reading     Over Limit    Limit        Factor     Type
                     (MHz)       Level       Level       (dB)          (dBuV)       (dB)
                                 (dBuV)      (dBuV)
1                    0.178       40.505      30.456      -24.073       64.578       10.049     QP
2                    0.178       19.370      9.320       -35.208       54.578       10.049     AV
3                    0.194       36.579      26.558      -27.284       63.864       10.021     QP
4                    0.194       20.909      10.888      -32.954       53.864       10.021     AV
5                    0.506       42.152      31.975      -13.848       56.000       10.177     QP
6                    0.506       30.767      20.590      -15.233       46.000       10.177     AV
7                    0.946       32.803      22.865      -23.197       56.000       9.938      QP
8                    0.946       21.329      11.391      -24.671       46.000       9.938      AV
9                    1.486       32.961      23.070      -23.039       56.000       9.891      QP
10                   1.486       20.844      10.953      -25.156       46.000       9.891      AV
11            *      13.560      50.099      40.000      -9.901        60.000       10.100     QP
12                   13.560      32.999      22.900      -17.001       50.000       10.100     AV
Note 1: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).
Note 2: 13.56MHz is NFC working frequency.


FCC ID: HD5-EDA710                                                                   Page Number: 27 of 30
IC: 11693B-EDA710


                                                                         Report No.: 1904RSU029-U6



8.   CONCLUSION
The data collected relate only the item(s) tested and show that the Tablet is in compliance with Part

15C of the FCC Rules and ISED rules.




                                              The End


FCC ID: HD5-EDA710                                                             Page Number: 28 of 30
IC: 11693B-EDA710


                                     Report No.: 1904RSU029-U6



Appendix A - Test Setup Photograph
Refer to “1904RSU029-UT” file.




FCC ID: HD5-EDA710                        Page Number: 29 of 30
IC: 11693B-EDA710


                                 Report No.: 1904RSU029-U6



Appendix B - EUT Photograph
Refer to “1904RSU029-UE” file.




FCC ID: HD5-EDA710                    Page Number: 30 of 30
IC: 11693B-EDA710



Document Created: 2019-05-20 14:46:51
Document Modified: 2019-05-20 14:46:51

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC