Report Reference No. .................... :               TRE1809007509                   R/C…….:15856

FCC ID ............................................. :    HD5-EDA511

Applicant’s name ........................... :            HONEYWELL INTERNATIONAL INC

Address ............................................. :   9860 OLD BAILES RD FORT MILL,SC 29707 United States

Manufacturer......................................:       HONEYWELL INTERNATIONAL INC

Address...............................................:   9860 OLD BAILES RD FORT MILL,SC 29707 United States

Test item description .................... :              Mobile Computer

Trade Mark ....................................... :      Honeywell

Model/Type reference ....................... :            EDA51-1

Listed Model(s) ................................. :       -

Standard ......................................... :      47 CFR FCC Part 15 Subpart B

Date of receipt of test sample………..:                      Sep 17,2018

Date of testing…………………………:                                Sep 18,2018- Oct 15,2018

Date of issue…………………………...:                               Oct 16,2018

Result .................. …………………...:                     Pass

Compiled by
( position+printed name+signature) .. :                   File administrators Silvia Li
Supervised by
( position+printed name+signature) .. :                   Project Engineer Aaron Fang
Approved by
( position+printed name+signature) .. :                   RF Manager Hans Hu


Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao,
                                                          Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.

The test report merely corresponds to the test sample.




                                                                 Page: 1 of 18


Report No : TRE1809007509                                                Page 2 of 18                                                          Issued: 2018-10-16




                                                                         Contents

1.       TEST STANDARDS AND REPORT VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1. Test Standards                                                                                                                                                       3
1.2. Report version                                                                                                                                                       错
误!未定义书签。


2.       TEST DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4



3.       SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1.    Client Information                                                                                                                                                5
3.2.    Product Description                                                                                                                                               5
3.3.    EUT operation mode                                                                                                                                                5
3.4.    Configuration of Tested System                                                                                                                                    5
3.5.    Support unit used in test configuration                                                                                                                           6

4.       TEST ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4.1.    Address of the test laboratory                                                                                                                                    7
4.2.    Test Facility                                                                                                                                                     7
4.3.    Environmental conditions                                                                                                                                          8
4.4.    Statement of the measurement uncertainty                                                                                                                          8
4.5.    Equipments Used during the Test                                                                                                                                   9

5.       TEST CONDITIONS AND RESULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 0

5.1.    Conducted Emissions Test                                                                                                                                          10
5.2.    Radiated Emissions Test                                                                                                                                           13

6.       TEST SETUP PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7



7.       EXTERNAL AND INTERNAL PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 8




Shenzhen Huatongwei International Inspection Co., Ltd.                                                     Report Template Version: V01 (2018-01)


Report No : TRE1809007509                         Page 3 of 18                         Issued: 2018-10-16



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014 – American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2018-10-16                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : TRE1809007509                       Page 4 of 18                               Issued: 2018-10-16



2. TEST DESCRIPTION
               Test Item                         Section in CFR 47                Result       Test Engineer
         Conducted Emissions                          15.107(a)                    Pass          Tony Duan
          Radiated Emissions                          15.109(a)                    Pass         Michael Jie


Note: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : TRE1809007509                     Page 5 of 18                            Issued: 2018-10-16



3. SUMMARY
3.1. Client Information
Applicant:                    HONEYWELL INTERNATIONAL INC

Address:                      9860 OLD BAILES RD FORT MILL,SC 29707 United States

Manufacturer:                 HONEYWELL INTERNATIONAL INC
Address:                      9860 OLD BAILES RD FORT MILL,SC 29707 United States

3.2. Product Description
Name of EUT:                  Mobile Computer

Trade Mark:                   Honeywell

Model No.:                    EDA51-1

Listed Model(s)               -
Power supply:                 DC 3.8V
                              Model:ADS-12B-06 05010E
Adapter information:          Input: 100-240Va.c., 50/60Hz, 0.3A
                              Output: 5.0Vd.c.,2.0A


3.3. EUT operation mode
Test mode                                                      Describe
Camera recording mode         Keep the EUT in Camera recording status
Video Playing mode            Keep the EUT in Video Playing status
Data exchange mode            Keep the EUT in Data exchange with PC status
Pre-scan all of above modes. Only show data exchange mode which is the worst case on the report.
3.4. Configuration of Tested System




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : TRE1809007509                     Page 6 of 18                         Issued: 2018-10-16


3.5. Support unit used in test configuration
                                                             FCC ID /
Item    Equipment      Manufacturer        Model No.                     Data Cable     Power Cord
                                                             FCC DoC
                                                                                        Unshielded
 1          PC             DELL         OptiPlex 3020 MT     FCC DoC         N/A
                                                                                          1.8m
                                                                                        Unshielded
 2        Monitor          DELL             E1912Hf          FCC DoC         N/A
                                                                                          1.8m
                                                                         Unshielded,
 3       Keyboard          DELL             SK8115           FCC DoC                        N/A
                                                                           1.5m
                                                                         Unshielded,
 4        Mouse            DELL             MS111-T          FCC DoC                        N/A
                                                                           1.5m
                                                                                        Unshielded
 5        Printer         EPSON               L101           FCC DoC         N/A
                                                                                          1.8m




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)


Report No : TRE1809007509                          Page 7 of 18                             Issued: 2018-10-16



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377B-1

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B-1.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : TRE1809007509                      Page 8 of 18                              Issued: 2018-10-16



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba



4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

                                                                            Measurement
                Test                             Range                                            Notes
                                                                             Uncertainty
Radiated Emissions                            30~1000MHz                      4.24 dB               (1)
Radiated Emissions                              1~18GHz                       5.16 dB               (1)
Conducted Disturbance                         0.15~30MHz                      3.39 dB               (1)

(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : TRE1809007509                       Page 9 of 18                        Issued: 2018-10-16



4.5. Equipments Used during the Test
Conducted Emissions

        Test                                                                Last Cal.     Next Cal.
Item                       Manufacturer         Model No.      Serial No.
        Equipment                                                           (mm-dd-yy)    (mm-dd-yy)
        EMI Test
1                          R&S                  ESCI           101247       11/11/2017    11/10/2018
        Receiver
2       Artificial Mains   SCHWARZBECK          NNLK 8121      573          11/11/2017    11/10/2018
        2-Line V-
3                          R&S                  ESH3-Z5        100049       11/11/2017    11/10/2018
        Network
4       Pulse Limiter      R&S                  ESH3-Z2        101488       11/11/2017    11/10/2018
        RF
5       Connection         HUBER+SUHNER         EF400          N/A          11/21/2017    11/20/2018
        Cable
6       Test Software      R&S                  ES-K1          N/A          N/A           N/A


Radiated Emissions

        Test                                                                Last Cal.     Next Cal.
Item                       Manufacturer         Model No.      Serial No.
        Equipment                                                           (mm-dd-yy)    (mm-dd-yy)
        Semi-
1       Anechoic           Albatross projects   SAC-3m-01      C11121       10/16/2016    10/15/2019
        Chamber
        EMI Test
2                          R&S                  ESCI           100900       11/11/2017    11/10/2018
        Receiver
3       Loop Antenna       R&S                  HFH2-Z2        100020       11/20/2017    11/19/2020
        Ultra-
4       Broadband          SCHWARZBECK          VULB9163       538          4/5/2017      4/4/2020
        Antenna
5       Horn Antenna       SCHWARZBECK          9120D          1011         3/27/2017     3/26/2020
        Broadband                                              BBHA9170
6                          SCHWARZBECK          BBHA9170                    3/27/2017     3/26/2020
        Horn Antenna                                           472
7       Pre-amplifier      SCHWARZBECK          BBV 9743       9743-0022    10/18/2017    10/17/2018
        Broadband
8                          SCHWARZBECK          BBV 9718       9718-248     10/18/2017    10/17/2018
        Pre-amplifier
        Spectrum
9                          R&S                  FSP40          100597       11/11/2017    11/10/2018
        Analyzer
        RF Connection      HUBER+SUHNE
10                                              RE-7-FL        N/A          11/21/2017    11/20/2018
        Cable              R
        RF Connection      HUBER+SUHNE
11                                              RE-7-FH        N/A          11/21/2017    11/20/2018
        Cable              R
12      Test Software      Audix                E3             N/A          N/A           N/A
13      Test Software      R&S                  ES-K1          N/A          N/A           N/A
14      Turntable          Maturo Germany       TT2.0-1T       N/A          N/A           N/A
15      Antenna Mast       Maturo Germany       CAM-4.0-P-12   N/A          N/A           N/A




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)


Report No : TRE1809007509                      Page 10 of 18                            Issued: 2018-10-16



5. TEST CONDITIONS AND RESULTS
5.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart B Section 15.107:
                                                                      Limit (dBuV)
          Frequency range (MHz)
                                                      Quasi-peak                        Average
                  0.15-0.5                             66 to 56*                        56 to 46*
                    0.5-5                                 56                               46
                    5-30                                  60                               50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4:2014
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 10 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 10 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


  Level [dBpVJ




                  1
                    .
                                ol __
                                           i1
   150k           0t
                 300k   400k    ©00k 800k 1M
                                                                 Frequency [Hz]

x x xMES    GM1809265023_fin



MEASUREMENT RESULT:                        "GM1809265023_fin"
9/26/2018             2:24PM
    Frequency                  Level     Tran sd                   Limit          Margin    Detector   Line    PE
          MHz                   dBuv            dB                  dBuV              dB

      0.168000                 41.70        10.                          65         23.4    QP         L1     GND
                                                  w N 0 O O i:




      0.532500                 35.50        10.                          56         20.5    QP         L1     GND
      1.509000                 30 .40       10.                          56         25.6    QP         L1     GND
      3.912000                 34 .70       10.                          56         21.3    QP         L1     GND
     10.459500                 42.70        10.                          60         17.3    QP         L1     GND
     15.931500                 38 .50       10.                          60         21.5    QP         L1     GND




MEASUREMENT RESULT:                        "GM1809265023_fin2"
9/26/2018             2:24PM
    Frequency                  Level     Tran sd                   Limit          Margin    Detector   Line    PE
          MHz                   dBuv            dB                  dBuV              dB

      0.177000                 35.80        10.                          55         18.8    AV         L1     GND
                                                  N N O O O i:




      0.532500                 25 .60       10.                          46         20. 4   AV         L1     GND
      1.279500                 26.10        10.                          46         19.9    AV         L1     GND
      4.456500                 30 .90       10.                          46         15.1    AV         L1     GND
     11.341500                 34 .80       10.                          50         15.2    AV         L1     GND
     15.256500                 35.50        10.                          50         14.5    AV         L1     GND


  Level [dBpVJ




                                               Frequency [Hz]

x x xMES    GM1809265024_fin


MEASUREMENT RESULT:                 "GM1809265024_fin"
9/26/2018          2:27PM
    Frequency             Level    Transd       Limit           Margin   Detector   Line    PE
                 MEz        dBuv          dB      dBuv              dB
     0.199500             39.70      10.1             64          23.9   QP         N      GND
     0.532500             37.00      10 .0            56          19.0   QP         N      GND
     1.284000             36.50      10 .0            56          19.5   QP         N      GND
     2.634000             37.80      10 .0            56          18.2   OP         N      GND
    10 .432500            39.70      10 .2            60          20.3   OP         N      GND
    15.994500             38 .30     10.3             60          21.7   QP         N      GND



MEASUREMENT RESULT:                 "GM1809265024_fin2"

9/26/2018          2:27PM
    Frequency             Level    Transd       Limit           Margin   Detector   Line    PE
                 MHz        dBuv          dB      dBuvy             dB
      0.172500            34 .60     10.1             55          20.2   AV         N      GND
      0. 541500           27.00      10 .0            46          19.0   AV         N      GND
     1.284000             27 .00     10   .0          46          19.0   AV         N      GND
     4.456500             31.10      10   .0          46          14.9   AV         N      GND
    11.476500             35.80      10   .2          50          14.2   AV         N      GND
    15.189000             35.90      10   .2          50          14.1   AV         N      GND


Report No : TRE1809007509                       Page 13 of 18                              Issued: 2018-10-16



5.2. Radiated Emissions Test
LIMIT

FCC CFR Title 47 Part 15 Subpart B Section 15.109
              Frequency                       Limit (dBuV/m @3m)                              Value
             30MHz-88MHz                                   40.00                           Quasi-peak
             88MHz-216MHz                                  43.50                           Quasi-peak
            216MHz-960MHz                                  46.00                           Quasi-peak
             960MHz-1GHz                                   54.00                           Quasi-peak
                                                           54.00                             Average
              Above 1GHz
                                                           74.00                              Peak

TEST CONFIGURATION

    30MHz ~ 1GHz




    Above 1GHz




TEST PROCEDURE

1.   The EUT was tested according to ANSI C63.4:2014.
2.   The EUT is placed on a turn table which is 0.8 meter above ground.
3.   The turn table is rotated 360 degrees to determine the position of the maximum emission level.
4.   The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
5.   The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
     repeated for both horizontal and vertical polarization of the antenna.
6.   Use the following spectrum analyzer settings
     (1) Span shall wide enough to fully capture the emission being measured;
     (2) Below 1GHz,
          RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, theemission measurement will be repeated using
          the quasi-peak detector and reported.
     (3) From 1GHz to 5th harmonic, RBW=1MHz, VBW=3MHz

Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : TRE1809007509                     Page 14 of 18                           Issued: 2018-10-16


TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable


Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Shenzhen Huatongwei International Inspection Co., Ltd.            Report Template Version: V01 (2018-01)


  Level [dBpVim]

80
70
60
50

40

30

20

 10



                                                          Frequency [Hz]

x x xMES        GM1809256077_red



MEASUREMENT RESULT:                   "GM1809256077_red"
9/25/2018     7:10PM
   Frequency       Level            Transd       Limit       Margin        Det.         Height    Azimuth      Polarization
          MHz     dBuV/m                dB      dBuV/m           dB                         cm        deg

   30000000               25.10       —13.3       40 .0        14.9        QP            300.0      336.00     HORIZONTAL
   70 .740000             28.00       —13.3       40 .0        12.0        QP            300.0       51.00     HORIZONTAL
   97 .900000             28 .20      —10.8       43.5         15.3        QP            300.0       92.00     HORTZONTAL
  194900000               29.00       —10.1       43.5         14.5        QP            100.0      307.00     HORIZONTAL
  243.400000              32.70        —8.6       46.0         13.3        OQP           100.0       86.00     HORTZONTAL
  864.200000              32.60         5.9       46.0         13.4        QP            100.0      224.00     HORTZONTAL

80 Level (dBu\Vim}
                                                                                                          FCC CLASS—B PK
70


60
                                                                                                          FCC CLASS—B AV

 50


40


 30


 20


 10


  0
      1000     1200          1500               2000                                                             5000     6000
                                                            Frequency (MHz)
Mark          Frequency     Reading    Antenna         Cable     Preamp            Level          Limit      Over       Remark
                MBZ         dBuv/m       dB            dB         dB              dBuv/m         dBuv/m      limit
      1   1047.69            46.2       25.3           4.3       37.3            38.5             74.0    ~39.5          Peak
      2   1327.24            42.6       26.1           4.9       37.2            36.4             74.0    —37.6          Peak
      3      777. 41         48.2       25.4           5.9       37 .4           42.1             74.0    —31.9          Peak
      4   2393.09            43.7       27.6           6.8        7.6            40.5             74.0    ~33.5          Peak
      5   3973.53            38.0       29.17          8.7       36.8            39.6             74.0    —34.4          Peak
      6   4796.04            40.2       31.6           9.5       35.7            45.6             74.0    —28.4          Peak


      Level [dBpV/im]
 80

 70

 60

 50

 40

 30

 20

 10

  0

                                                          Frequency [Hz]

x x       xMES   GM1809256079_red



MEASUREMENT RESULT:                  "GM1809256079_red"
9/25/2018     7:15PM
   Frequency       Level            Transd      Limit       Margin         Det.        Height     Azimuth         Polarization
          MHz     dBuV/m                dB      dBpV/m          dB                         cm         deg

       30000000           27.20      —13.3       40 .0         12.8        QP           100 .0      104.00        VERTICAL
       70740000           25.70      —13.3       40 .0         14.3        QP           100 .0      129.00        VERTICAL
      130.880000          29 .60     —13.4       43.5          13.9        QP           100 .0      170.00        VERTICAL
      194.900000          30.50      —10.1       43.5          13.0        QP           100 .0       48.00        VERTICAL
      547980000           26.10       —0.8       46.0          19.9        QP           100 .0           0.00     VERTICAL
      928.220000          34.60        7.1       46.0          11.4        QP           100 .0           0.00     VERTICAL

so Level (dBuVim)
                                                                                                            FCC CLASS—B PK
70


60
                                                                                                           FCC CLASS—B AV

50


40


 30


20


 10


  0
      1000       1200        1500             2000                                                                  5000     6000
                                                          Frequency (MHz)
Mark         Frequency     Reading    Antenna      Cable        Preamp            Level           Limit         Over       Remark
                 MBZ       dBuv/m       ds           dB          dB              dBuv/m          dBuv/m         limit
      1    1047.59          48.5       25.3          4.3        37.3            40.9              74.0      —33.1           Peak
      2    1360.95          49.9       26.0          4.9        37.1            43.7              74.0      —30.3           Peak
      3    1441.26          50.1       25.9          5¥A        27A             44.0              74.0      —30.0           Peak
      4    1690.43          44.0       25.2          5.7        37.3            37.6              74.0      —36.4           Peak
      5    2401.69          44.2        7.6          6.8        37.6            41.0              74.0      —33.0           Peak
      6    4804.54          38.2       31.6          9.5        35.7            43.6              74.0      —30.4           Peak


Report No : TRE1809007509                     Page 17 of 18                      Issued: 2018-10-16



6. TEST SETUP PHOTOS OF THE EUT
Conducted Emissions (AC Mains)




Radiated Emissions (30MHz-1GHz)




Radiated Emissions (Above 1GHz)




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : TRE1809007509                     Page 18 of 18                        Issued: 2018-10-16




7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT