SAR report part 3

FCC ID: HD5-EDA511

RF Exposure Info

Download: PDF
FCCID_4054280

                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/29/2018

LTE Band 4-Head

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.363 S/m; εr = 41.972; ρ = 1000 kg/m3

Phantom section: Left Section
Ambient Temperature:22.8℃;Liquid Temperature:22.5℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(9.23, 9.23, 9.23) @ 1732.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 20175/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 1.08 W/kg

Left Touch Cheek/CH 20175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 7.988 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 1.09 W/kg
SAR(1 g) = 0.714 W/kg; SAR(10 g) = 0.451 W/kg
Maximum value of SAR (measured) = 0.950 W/kg




              0 dB = 0.950 W/kg = -0.22 dBW/kg




                                                                                             Plot No.13


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/30/2018

LTE Band 4-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.43 S/m; εr = 53.892; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.8℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.77, 8.77, 8.77) @ 1732.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 20175/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.749 W/kg

Rear/CH 20175/Zoom Scan (5x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 18.99 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 0.896 W/kg
SAR(1 g) = 0.535 W/kg; SAR(10 g) = 0.352 W/kg
Maximum value of SAR (measured) = 0.751 W/kg




              0 dB = 0.751 W/kg = -1.24 dBW/kg




                                                                                             Plot No.14


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab         Date: 9/25/2018

LTE Band 5-Head

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.933 S/m; εr = 42.5599; ρ = 1000 kg/
m3 Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.3℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.73, 10.73, 10.73) @ 836.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 20525/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.251 W/kg

Left Touch Cheek/CH 20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 5.172 V/m; Power Drift = 0.19 dB
Peak SAR (extrapolated) = 0.267 W/kg
SAR(1 g) = 0.201 W/kg; SAR(10 g) = 0.151 W/kg
Maximum value of SAR (measured) = 0.241 W/kg




              0 dB = 0.241 W/kg = -6.18 dBW/kg




                                                                                              Plot No.15


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/26/2018

LTE Band 5-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.967 S/m; εr = 55.399; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.5, 10.5, 10.5) @ 836.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 20525/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.584 W/kg

Rear/CH 20525/Zoom Scan (6x7x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 15.93 V/m; Power Drift = 0.13 dB
Peak SAR (extrapolated) = 0.650 W/kg
SAR(1 g) = 0.359 W/kg; SAR(10 g) = 0.243 W/kg
Maximum value of SAR (measured) = 0.506 W/kg




              0 dB = 0.506 W/kg = -2.96 dBW/kg




                                                                                             Plot No.16


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab      Date: 10/8/2018

LTE Band 7-Head

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 2535 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2535 MHz; σ = 1.914 S/m; εr = 40.778; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(7.92, 7.92, 7.92) @ 2535 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 21100/Area Scan (81x151x1): Interpolated grid: dx=1.200 mm,
dy=1.200 mm
Maximum value of SAR (interpolated) = 0.711 W/kg

Left Touch Cheek/CH 21100/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 8.945 V/m; Power Drift = 0.16 dB
Peak SAR (extrapolated) = 0.914 W/kg
SAR(1 g) = 0.505 W/kg; SAR(10 g) = 0.285 W/kg
Maximum value of SAR (measured) = 0.761 W/kg




              0 dB = 0.761 W/kg = -1.19 dBW/kg




                                                                                           Plot No.17


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab      Date: 10/9/2018

LTE Band 7-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 2535 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2535 MHz; σ = 2.082 S/m; εr = 52.884; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.8℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(7.51, 7.51, 7.51) @ 2535 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 21100/Area Scan (81x151x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 1.21 W/kg

Rear/CH 21100/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 11.03 V/m; Power Drift = 0.18 dB
Peak SAR (extrapolated) = 1.55 W/kg
SAR(1 g) = 0.745 W/kg; SAR(10 g) = 0.385 W/kg
Maximum value of SAR (measured) = 1.20 W/kg




              0 dB = 1.20 W/kg = 0.79 dBW/kg




                                                                                           Plot No.18


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/25/2018

LTE Band 26-Head

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 831.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 831.5 MHz; σ = 0.93 S/m; εr = 42.524; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.3℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.73, 10.73, 10.73) @ 831.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 26865/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.324 W/kg

Left Touch Cheek/CH 26865/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 6.495 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 0.359 W/kg
SAR(1 g) = 0.269 W/kg; SAR(10 g) = 0.202 W/kg
Maximum value of SAR (measured) = 0.329 W/kg




              0 dB = 0.329 W/kg = -4.83 dBW/kg




                                                                                             Plot No.19


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/26/2018

LTE Band 26-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 831.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 831.5 MHz; σ = 0.964 S/m; εr = 55.411; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.5, 10.5, 10.5) @ 831.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 26865/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.484 W/kg

Rear/CH 26865/Zoom Scan (6x7x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 15.34 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 0.536 W/kg
SAR(1 g) = 0.292 W/kg; SAR(10 g) = 0.197 W/kg
Maximum value of SAR (measured) = 0.418 W/kg




              0 dB = 0.418 W/kg = -3.79 dBW/kg




                                                                                             Plot No.20


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 10/8/2018

LTE Band 41-Head

Communication System: UID 0, Generic LTE-TDD (0); Frequency: 2593 MHz;Duty Cycle:
1:1.59882
Medium parameters used (interpolated): f = 2593 MHz; σ = 1.964 S/m; εr = 40.64; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.8℃;Liquid Temperature:22.3℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(7.92, 7.92, 7.92) @ 2593 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 40620/Area Scan (81x151x1): Interpolated grid: dx=1.200 mm,
dy=1.200 mm
Maximum value of SAR (interpolated) = 0.356 W/kg

Left Touch Cheek/CH 40620/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 7.047 V/m; Power Drift = -0.15 dB
Peak SAR (extrapolated) = 0.407 W/kg
SAR(1 g) = 0.225 W/kg; SAR(10 g) = 0.125 W/kg
Maximum value of SAR (measured) = 0.335 W/kg




              0 dB = 0.335 W/kg = -4.75 dBW/kg




                                                                                             Plot No.21


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 10/9/2018

LTE Band 41-Body

Communication System: UID 0, Generic LTE-TDD (0); Frequency: 2593 MHz;Duty Cycle:
1:1.59882
Medium parameters used (interpolated): f = 2593 MHz; σ = 2.143 S/m; εr = 52.791; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(7.51, 7.51, 7.51) @ 2593 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 40620/Area Scan (81x151x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.761 W/kg

Rear/CH 40620/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 8.082 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 0.984 W/kg
SAR(1 g) = 0.470 W/kg; SAR(10 g) = 0.246 W/kg
Maximum value of SAR (measured) = 0.755 W/kg




              0 dB = 0.755 W/kg = -1.22 dBW/kg




                                                                                             Plot No.22


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 10/10/2018

WIFI 2.4G-Head

Communication System: UID 0, Generic WIFI (0); Frequency: 2437 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 2437 MHz; σ = 1.829 S/m; εr = 41.002; ρ = 1000 kg/m3
Phantom section: Right Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.27, 8.27, 8.27) @ 2437 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Right Cheek Touch/CH 6/Area Scan (81x151x1): Interpolated grid: dx=1.200 mm, dy=1.200
mm
Maximum value of SAR (interpolated) = 1.46 W/kg

Right Cheek Touch/CH 6/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 13.57 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 1.71 W/kg
SAR(1 g) = 0.607 W/kg; SAR(10 g) = 0.411 W/kg
Maximum value of SAR (measured) = 1.40 W/kg




              0 dB = 1.40 W/kg = 1.46 dBW/kg




                                                                                             Plot No.23


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 10/10/2018

WIFI 2.4G-Body

Communication System: UID 0, Generic WIFI (0); Frequency: 2437 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 2437 MHz; σ = 1.991 S/m; εr = 53.023; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.8℃;Liquid Temperature:22.5℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.08, 8.08, 8.08) @ 2437 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 6/Area Scan (81x151x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.472 W/kg

Rear/CH 6/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 3.935 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 0.606 W/kg
SAR(1 g) = 0.289 W/kg; SAR(10 g) = 0.143 W/kg
Maximum value of SAR (measured) = 0.474 W/kg




              0 dB = 0.474 W/kg = -3.24 dBW/kg




                                                                                             Plot No.24