SAR CALIBRATION REPORT Part2

FCC ID: HD5-EDA510

RF Exposure Info

Download: PDF
FCCID_3874492

Report No.: BL-EC1850176-701


                                 mvGo




   SAR Reference Waveguide Calibration Report



                                              Ref : ACR.93.10.17.SATU.A




SHENZHEN BALUN TECHNOLOGY CO.,LTD.
      BLOCK B, FL 1, BAISHA SCIENCE AND
TECHNOLOGY PARK, SHAHE XI ROAD,NANSHAN
DISTRICT, SHENZHEN, GUANGDONG PROVINCE,
 P.R. CHINA 518055MVG COMOSAR REFERENCE
                 WAVEGUIDE
            FREQUENCY: 5000—6000 MHZ
            SERIAL NO.: SN 49/16 WGA 42
                          Calibrated at MVG US
                2105 Barrett Park Dr. — Kennesaw, GA 30144

                           u>

                        L o nf
                         zZ7(acerepiteo)
                          Cld tuie® csitrincent sszcecs
                       Calibration Date: 03/22/2017


   Summary:

   This document presents the method and results from an accredited SAR reference waveguide
   calibration performed in MVG USA using the COMOSAR test bench. All calibration results are
   traceable to national metrology institutions.


LU1

mvg                   SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                  Ref: ACR.93.10.17.SATU—A




                                 Name                               Function                         Date                  Signature

Prepared by :                Jérome LUC                       Product Manager                    4/3/2017                    fi

Checked by :                 Jérome LUC                        Product Manager                   4/3/2017                    fi

Approved by :          Kim RUTKOWSKI                           Quality Manager                   4/3/2017                 Jum Putthowih!




                                                                       Customer Name
                                                                       SHENZHEN
                                        Elutuibizn s                    BALUN
                                      Distribution :                  TECHNOLOGY
                                                                             Co..Ltd.




   Issue                  Date                                                         Modifications
     A                  4/3/2017                  Initial release




                                                             Page: 2/13

                This document shall not be reproduced, except inl or in part, without the writien approval ofMTG
                The information contained herein is t be used onlyfor the purposefor which itis submitted and is not to
                be released in whole orpart without vritten approval ofMVG.


 )                             m
mvgG                      SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                  Sef A0K.98.1017.BA7U A




                                                    TABLE OF CONTENTS



1.     IMFOUWAIIOR——mmeemnmemmmmmmmmmnmmmmmnnnannemememenennarmnnmmcren 4
2      D@ViC@ UMG@P TeSt .......ccesssscennmeceenmmnreenmnneennmnnemmseenmnrrenmnrennmnnsenmenseemmsenmemen 4
3      PFOUUCE DeSCHPHION ——mmemmmmmmemmnnmmeennnemmenmeanmemenmenmmennimen 4
     3.1      General Information                                                                                                         4
4      Measurement Method
     4.1      Return Loss Requirements                                                                                                    4
     4.2      Mechanical Requirements                                                                                                     4
5.     MCASUPM@NE UNCGPIAIMEY ....cs.lccecesnnneccnnmmnccenmmnnnmnnnrenmnrcennnrrernnereennmnnrennmnnsemmneeenmen 5
     §4       Return Loss                                                                                                                 5
     5.2      Dimension Measurement                                                                                                       5
     5.3      Validation Measurement                                                                                                      5
0      CaHBIATIOMMCASUEEI@AERESUI®:......oommmmmmecmeemmecrmmemecommmeccertercmtecemneeriienctecs 3
     6.1      Return Loss                                                                                                                 5

     6.2      Mechanical Dimensions                                                                                                       6
7      NARAAAIOAMGASUMAGNE ——....oo c ommmmmmmeminnnememmnmenniammecnnemene 7
     7.1      Head Liquid Measurement                                                                                                     7
     7.2      Measurement Result                                                                                                          7
     7.3      Body Measurement Result                                                                                                    10
8      List of Equipment..




                                                                 Page: 3/13

                    This document shall not be reproduced, except inl or in part, without the writien approval ofMTG
                    The information contained herein is t be used onlyfor the purposefor which itis submitted and is not to
                    be released in whole orpart without vritten approval ofMVG.


)                         m
n4e                  SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                  Ref: ACR.93.10.17.SATU.A




1             INTRODUCTION

This document contains a summary of the requirements set forth by the IEEE 1528 and CEMIEC
62209 standards for reference waveguides used for SAR measurement system validations and the
measurements that were performed to verify that the product complies with the fore mentioned
standards.

2             DEVICE UNDER TEST



                                                   Device Under Test
      Device Type                                  COMOSAR 5000—6000 MHz REFERENCE WAVEGUIDE
      Manufacturer                                 MVG
      Model                                        SWGSS500
      Serial Number                                SN 49/16 WGA 42
      Product Condition (new / used)               New

A yearly calibration interval is recommended.

3             PRODUCT DESCRIPTION

3.1         GENERAL INFORMATION

MVG‘s COMOSAR Validation Waveguides are built in accordance to the IEEE 1528 and CEMIEC
62209 standards.

        4     MEASUREMENT METHOD
The IEEE 1528 and CEVIEC 62209 standards provide requirements for reference waveguides used
for system validation measurements. The following measurements were performed to verify that the
product complies with the fore mentioned standards.

        4.1    RETURN LOSS REQUIREMENTS
The waveguide used for SAR system validation measurements and checks must have a return loss of
—8 dB or better. The return loss measurement shall be performed with matching layer placed in the
open end of the waveguide, with the waveguide and matching layer in direct contact with the
phantom shell as outlined in the fore mentioned standards.

        4.2    MECHANICAL REQUIREMENTS
The IEEE 1528 and CEVIEC 62209 standards specify the mechanical dimensions of the validation
waveguide, the specified dimensions are as shown in Section 6.2. Figure 1 shows how the
dimensions relate to the physical construction of the waveguide.

                                                            Page: 4/13

               This document shall not be reproduced, except inl or in part, without the writien approval ofMTG
               The information contained herein is t be used onlyfor the purposefor which itis submitted and is not to
               be released in whole orpart without vritten approval ofMVG.


)                            m
                      SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                 Sef A0K.98.1017.BA7U A



5            MEASUREMENT UNCERTAINTY

All uncertaintieslisted below represent an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2, traceable to the Internationally Accepted Guides to
Measurement Uncertainty.

       5.1    RETURN LOSS
The following uncertainties apply to the return loss measurement:
                       Frequency band                                  Expanded Uncertainty on Return Loss

                            400—6000MHz                                                         0.1 dB

       5.2   DIMENSION MEASUREMENT
The following uncertainties applyto the dimension measurements:
                            Length (mm)                                   Expanded Uncertainty on Length
                              3 — 300                                                           0.05 mm

       5.3    VALIDATION MEASUREMENT
The guidelines outlined in the IEEE 1528 and CEVIEC 62209 standards were followed to generate
the measurement uncertainty for validation measurements.
                     Scan Volume                     Expanded Uncertainty
                                1 g                                                   20.3 %
                                10 g                                                  20.1 %

       6     CALIBRATION MEASUREMENT RESULTS

       6.1    RETURN LOSS IN HEAD LIQUID
                                                                Frequency, MHz
                                   sauo       ul         5400        seoo      seoo      5700      Eul        sa00
                   St1, 8




                                                            Page: 5/13

              This document shall not be reproduced, except inl orin part, without the writien approval of MTG
              The information contained herein is to be used onlyfor the purposefor whichit is submitted and is not to
              be released in whole orpart without vritten approval ofMVG.


)                                m
                            SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                    Sef A0K.98.1017.BA7U A



Frequency (MHz)                    Return Loss (dB)                 Requirement (dB)                           Impedance
           5200                             —9.43                                —8                      21.12 Q + 10.51 i0
           5400                            —11.06                                —8                       75.87 9 +2.02 j02
           5600                            —13.60                                —8                      33.60 O — 11.85 jQ
           5800                            —13.16                                —8                      54.47 9 +20.92 j(


           6.2      RETURN LOSS IN BODY LIQUID
                                                                        Frequency, MHz
                                stoo       saoo       san0       sioo        seoo      seo0      srto       se00      sand




                           $




Frequency (MHz)                    Return Loss (dB)                 Requirement (dB)                         Impedance
      5200                               —8.78                             —8                            19.41 Q +11.57 j@Q
      5400                              —10.37                             —8                             77.76 2 + 0.60 j62
      5600                              —12.68                             —8                            30.83 Q — 11.35 jQ
      5800                              —12.11                             —8                            §5.27 t +23.37 jta




           6.3      MECHANICAL DIMENSIONS
                                                 W (mm)                       L« (mm)                  Wi(mm)                           T (mm
Frequene
yiNt|            RequireLuunk
                            Measure        Require Measure              Require Measure           Require Measure                Require Measure
i                   d          a              a         a                  a          a              d        a                     a          a
  s7                                                                                    s
  5200             is
                 40.39 +
                             passm           §3
                                            20.19 +
                                                      l                   y
                                                                        81.03+
                                                                                    pass            yA
                                                                                                  61.98 +
                                                                                                            pass                   s3 =      passs
                 40.39 +                    20.19+                      81.03+                    61.98 +                              y
 5800              o13         PASS          ol3          PASS           0.13         PASS          o13            PASS           43        PASS


* The tolerance for the matching layeris included in thereturn loss measurement.




                                                                    Page: 6/13

                      This document shall not be reproduced, except inl orin part, without the writien approval of MTG
                      The information contained herein is to be used onlyfor the purposefor whichit is submitted and is not to
                      be released in whole orpart without vritten approval ofMVG.


)                        m
n4e                 SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                   Ref: ACR.93.10.17.SATU.A




                                                           Matching layer




                                Figure 1: Validation Waveguide Dimensions

       7     VALIDATION MEASUREMENT
The IEEE Std. 1528 and CEUIEC 62209 standards state that the system validation measurements
must be performed using a reference waveguide meeting the fore mentioned return loss and
mechanical dimension requirements.     The validation measurement must be performed with the
matching layer placed in the open end of the waveguide, with the waveguide and matching layer in
direct contact with the phantom shell.

       7.1   HEAD LIQUID MEASUREMENT


                      Fre:dl:-{ezncy                                                 Conductivity (0} 5/m

                                             required           measured            required         measured

                          5000              36.2 £10%                             4.45 £10 %
                          5100              36.1210%                              4.56 £10 %
                          5200              36.0 £10%              PASS           4.66 £10 %            PASS
                          5300              35.9£10%               PASS           4.76 £10 %            PASS
                          5400              35.8 £10%              PASS           4.86 £10 %            PASS
                          5500              35.6 210 %             PASS           4.97 £10 %            PASS
                          5600              35.5 £10%              PASS           5.07 £10 %            PASS
                          5700              35.4 £10%                             5.17 £10%
                          5800              35.3:10%               PASS           5.27 £10%             PASS
                          5900              35.2 10 %                             5.38 £10 %
                          6000              35.1 £10%                             5.48 £10%



       7.2    SAR MEASUREMENT RESULT WITH HEAD LIQUID
At those frequencies, the target SAR value can not be generic. Hereunder is the target SAR value
defined by MVG, within the uncertainty for the system validation. All SAR values are normalized
to 1 W net power. In bracket, the measured SAR is given with the used input power.

                                                            Page: 7/13

              This document shall not be reproduced, except infull or in part, without the written approval ofMVG
              The information contained herein is to be used onlyfor the purposefor which itis submitted and is not to
              be released in whole orpart without written approval ofMVG


)                          m
                      SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                    ho A0K 98.1017.BA71 A



Software                                                               OPENSAR va
Phantom                                                                SN 20(09 SAM71
Frobe                                                                  SN 18711 EPG122
Liquid                                                                 Head Liquid Values 5200 MHz: eps! :35.64 sigma : 4.67
                                                                       Head Liquid Values 5400 MHz: eps! :36.44 sigma : 4.87
                                                                       Head Liquid Values 5600 MHz: eps‘ :36.66 sigma: 5.17
                                                                       Head Liquid Values 5800 MHz: eps‘ :35.31 sigma: 5.31
Distance between dipole waveguide and liquid                           0 mm
Area scan resolution                                                   dx—8mm/dy—&mm
Zoon Scan Resolution                                                   dx=4mm/dy—4m/dz—2mm
Frequency                                                              5200 MHz
                                                                       5400 MHz
                                                                       5600 MHz
                                                                       5800 MHz
Input power                                                            20 dBm
Liquid Temperature                                                     21 °C
Lab Temperature                                                        21 °C
Lab Humidity                                                           45 %



Frequency (MHz)                       1 g SAR (W/kg)                                                  10 g SAR (W/kg)
                                required          measured                                      required          measured
         5200                    159.00         161.03 (16.10)                                    56.90          56.23 (5.62)
         5400                    166.40         168.17 (16.82)                                   58.43           57.98 (5.80)
         5600                    173.80         175.43 (17.54)                                    59.97          59.94 (3.99)
         5800                    181.20         182.30 (18.23)                                   61.50           61.84 (6.18)




_SAR MEASUREMENT PLOTS @ 5200 MHz
                                                                                        # 8
                                                                                       sn wig




  @8) arel        *       f                                                                                    m rou t         2 a d
                 3t 3 viea                                                                                       Zinn




                                                              Page: 8/13
                This document shall not be reproduced, except inl orin part, without the writienapproval ofMTG
                The information contained herein is to be used onlyfor the purposefor which it is submitted and is not to
                be released in whole orpart without vritten approval ofMVG.


C‘                  mm
               SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                   Sef A0K.98.1017.BA7U A



 SAR MEASUREMENT PLOTS @ 5400 MHz




                                                                               sin wig
                                                                                     #
                                                                                                        hob kn a 2 A &
                                                                                                          Zinnl


 SAR MEASUREMENT PLOTS @, 5600 MHz
           eomme=




                                                                                     oo                                      .
                                                                                                           tm is me a      A &
                                                                                                           Zined


 SAR MEASUREMENT PLOTS @ 5800 MHz
                                                                               san twia
                                                                                    #




                                                                                     oo                                      .
                                                                                           e         io ru kn a            a &
          3 t 5 ven                                                                                     Zimel




                                                       Page: 9/13

         This document shall not be reproduced, except inl orin part, without the writien approval of MTG
         The information contained herein is to be used onlyfor the purposefor whichit is submitted and is not to
         be released in whole orpart without vritten approval ofMVG.


)                         m
mvgG                  SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                 Ref: ACR.93.10.17.SATU.A




         7.3   BODY LIQUID MEASUREMENT
                        Frequency
                           MHz                Relative permittivity (€,‘)             Conductivity {0) S/m

                                              required           measured           required         measured
                          5200               49.0210%               PaS$           5.30£10%             PaSs
                          5400               48.7 210%              PaSs           5.53 410%            PaSS$
                          5600               48.5 210 %             pass           5.77210%             pass
                          5800               48.2210%               PaSs           6.00210%             Pass




         7.4   SAR MEASUREMENT RESULT WITH BODY LIQUID
Satiwne                                                              OPENSAR va
Phaniom                                                              SN 20700 SAM7]
Probe                                                                SN 1871 EPG122
Liquid                                                               Body Liquid Values        5200 MHz:     eps!   :48.64   sigma :   5.51
                                                                     Body Liquid Values        5400 MHz:     eps!   :46.52   sigma :   5.77
                                                                     Body Liquid Values        5600 MHz:     eps‘   46.79    sigma :   5.77
                                                                     Body Liquid Values        5800 MHz:     eps    :47.04   sigma:    6.10
Distance between dipole waveguide and liquid                         O mm
Area scan resolution                                                 dx=8mm/dy=&mm
Zoon Scan Resolution                                                 dx—4mm/dy=4m/de~2mm
Frequency                                                            5200 MHz
                                                                     5400 MHz
                                                                     5600 MHz
                                                                     5800 MHz
Input power                                                          20 dBm
Liquid Temperature                                                   21°C
Lab Temperature                                                      21 °C
Lab Humidity                                                         45 %



         Frequency (MHz)                               1 g SAR (W/hkg)                                   10 g SAR (W/kg)
                                                          measured                                           measured
               5200                                     158.91 (15.89)                                     56.35 (3.63)
               5400                                     164.39 (16.44)                                     $7.72(3.77)
               5600                                     170.90 (17.09)                                     59.37 (3.94)
               5800                                     177.09 (17.71)                                     61.19 (6.12)




                                                           Page: 10/13

               This document shall not be reproduced, except inl or in part, without the writienapproval ofMTG
               The information contained herein is t be used onlyfor the purposefor which itis submitted and is not to
               be released in whole orpart without vritten approval ofMVG.


C‘                  mm
               SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                   Sef A0K.98.1017.BA7U A



 BODY SAR MEASUREMENT PLOTS @ 5200 MHz




                                                                                      #
                                                                               sin wia
                                                                                          oo                          .
                                                                                            6           i rou n a 2 a &
                                                                                                          Zinnl


 BODY SAR MEASUREMENT PLOTS @ 5400 MHz
           emome=




                                                                                                     6 n m ns te           A &
                                                                                                       Zined


 BODY SAR MEASUREMENT PLOTS @ 5600 MHz
                                                                                                2
                                                                               sin twig




                                                                                          oo                                 .
                                                                                                e    io ru kn a            a &
          3 t 5 ven                                                                                     Zimel




                                                      Page: 11/13

         This document shall not be reproduced, except inl orin part, without the writien approval of MTG
         The information contained herein is to be used onlyfor the purposefor whichit is submitted and is not to
         be released in whole orpart without vritten approval ofMVG.


C                  mm
              SAR REFERENCE WAVEGUIDE CALIBRATION REPORT                                                    Ref: ACR.93.10.17.SATU.A




BODY SAR MEASUREMENT PLOTS @ 5800 MHz




                                                                                                       t t n a 2 a &
                                                                                                         Zinnl




                                                     Page: 12/13

        This document shall not be reproduced, except inl orin part, without the writien approval ofMTG
        The information contained herein is to be used onlyfor the purposefor which it is submitted and is not to
        be released in whole orpart without vritten approval ofMVG.


Report No.: BL-EC1850176-701



Document Created: 2018-05-30 01:12:54
Document Modified: 2018-05-30 01:12:54

© 2024 FCC.report