18C2057R-RF-FCC Part15C-Wireless Charge Rack-CN85-WCR-V1.0 0117

FCC ID: HD5-CX85WCR

Test Report

Download: PDF
FCCID_4132592

                                        Test Report
                                       FCC Part15 Subpart C



                 Product Name               : Wireless Charge Rack
                 Model No.                  : CN85-WCR
                 FCC ID                     : HD5-CX85WCR
                 IC                         : 1693B-CX85WCR




             Applicant : HONEYWELL INTERNATIONAL INC
                         Honeywell Safety and Productivity Solutions
             Address : 9680 OLD BAILES RD
                         FORT MILL SC 29707-7539



                Date of Receipt : Dec. 12, 2018
                Test Date                : Dec. 13, 2018~ Dec. 31, 2018
                Issued Date              : Jan. 07, 2019
                Report No.               : 18C2057R-RF-US-P06V05
                Report Version : V1.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by A2LA or any agency of the government.
The test report shall not be reproduced without the written approval of DEKRA Testing and Certification
(Suzhou) Co., Ltd.


Report No.: 18C2057R-RF-US-P06V05



                       Tes t R e p o r t C e r t i f i c a t i o n
                                                     Issued Date : Jan. 07, 2019
                                                     Report No. : 18C2057R-RF-US-P06V05



     Product Name           :   Wireless Charge Rack
     Applicant              :   HONEYWELL INTERNATIONAL INC
                                Honeywell Safety and Productivity Solutions
     Address                :   9680 OLD BAILES RD
                                FORT MILL SC 29707-7539
     Manufacturer           :   1.HONEYWELL INTERNATIONAL INC
                                Honeywell Safety and Productivity Solutions
                                2.RAYVAL (SUZHOU) TECHNOLOGIES CO LTD
                                3.Metro(Suzhou)Technologies Co.,Ltd
     Address                :   1.9680 OLD BAILES RD
                                FORT MILL SC 29707-7539
                                2.SUCHUN INDUSTRIAL SQUARE, BLDG 15A 428 XINGLONG STR
                                SUZHOU INDUSTRIAL PARK SUZHOU JIANGSU 215126 CHINA
                                3.No.221 Xinghai street China-Singapore Suzhou Industrial Park
     Model No.              :   CN85-WCR
     FCC ID                 :   HD5-CX85WCR
     IC                         1693B-CX85WCR
     EUT Voltage            :   AC 120V/60Hz
     Test Voltage           :   AC 120V/60Hz
     Brand Name             :   Honeywell
     Applicable Standard    :   FCC CFR Title 47 Part 15 Subpart C; ANSI C63.10: 2013
                                KDB 680106 D01 RF Exposure Wireless Charging Apps v03
                                RSS-216 Issue 2
     Test Result            :   Complied
     Performed Location     :   DEKRA Testing and Certification (Suzhou) Co., Ltd.
                                No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu,
                                China
                                TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                                FCC Designation Number: CN1199; IC Lab Code: 4075B

    Documented By           :

                                            ( Adm. Specialist: Kitty Li )

    Reviewed By             :

                                      (Senior Project Manager: Frank He )

    Approved By             :

                                      (Engineering Supervisor: Jack Zhang)


                                           Page: 2 of 31


Report No.: 18C2057R-RF-US-P06V05


                                             TABLE OF CONTENTS
Description                                                                                                               Page
1. General Information ...................................................................................................... 5
1.1. EUT Description ............................................................................................................ 5
1.2. Antenna information ...................................................................................................... 6
1.3. Mode of Operation ........................................................................................................ 7
1.4. Tested System Details .................................................................................................. 8
1.5. Configuration of Tested System .................................................................................... 9
1.6. EUT Exercise Software ............................................................................................... 10
2. Technical Test ............................................................................................................. 11
2.1. Summary of Test Result .............................................................................................. 11
2.2. Test Environment ........................................................................................................ 11
3. Conducted Emission ................................................................................................... 12
3.1. Test Equipment ........................................................................................................... 12
3.2.   Test Setup ................................................................................................................... 12
3.3.   Limit ............................................................................................................................ 13
3.4.   Test Procedure ............................................................................................................ 13
3.5.   Uncertainty .................................................................................................................. 13
3.6.   Test Result .................................................................................................................. 14
4.     Radiated Emission ...................................................................................................... 17
4.1.   Test Equipment ........................................................................................................... 17
4.2.   Test Setup ................................................................................................................... 18
4.3.   Limit ............................................................................................................................ 19
4.4.   Test Procedure ............................................................................................................ 19
4.5.   Uncertainty .................................................................................................................. 20
4.6.   Test Result .................................................................................................................. 21
5.     20dB Occupied Bandwidth .......................................................................................... 27
5.1.   Test Equipment ........................................................................................................... 27
5.2.   Test Setup ................................................................................................................... 28
5.3.   Limit ............................................................................................................................ 29
5.4.   Test Procedure ............................................................................................................ 29
5.5.   Uncertainty .................................................................................................................. 29
5.6.   Test Result .................................................................................................................. 30
6.     Antenna Requirement ................................................................................................. 31
6.1.   Requirement ............................................................................................................... 31
6.2. Result .......................................................................................................................... 31




                                                             Page: 3 of 31


Report No.: 18C2057R-RF-US-P06V05


History of This Test Report
        REPORT NO.             VERSION           DESCRIPTION     ISSUED DATE


 18C2057R-RF-US-P06V05        V1.0       Initial Issued Report   Jan. 07, 2019




                                     Page: 4 of 31


Report No.: 18C2057R-RF-US-P06V05


1.     General Information
1.1. EUT Description
Product Name                        Wireless Charge Rack
Model No.                           CN85-WCR
Working Voltage                     AC 120V/60Hz
Frequency Range                     110kHz~145KHz
Type of Modulation                  ASK




                                          Page: 5 of 31


Report No.: 18C2057R-RF-US-P06V05


1.2. Antenna information
Model No.                N/A
Antenna manufacturer     N/A
Antenna Delivery               1*TX+1*RX                  2*TX+2*RX   3*TX+3*RX
Antenna technology             SISO
                                               Basic
                                               CDD
                               MIMO
                                               Sectorized
                                               Beam-forming
Antenna Type                                   Dipole
                               External
                                               Sectorized
                                               PIFA
                                               PCB
                               Internal        Ceramic Chip Antenna
                                               Loop antenna
                                               Type F antenna




                                          Page: 6 of 31


Report No.: 18C2057R-RF-US-P06V05


1.3. Mode of Operation
DEKRA has verified the construction and function in typical operation. All the test modes were
carried out with the EUT in normal operation, which was shown in this test report and defined as:


Test Mode
Mode 1: Transmit


Note:
1. Regards to the frequency band operation: the lowest、middle and highest frequency of channel
  were selected to perform the test, then shown on this report.
2. For portable device, radiated spurious emission was verified over X, Y, Z Axis, and shown the
  worst case on this report.




                                            Page: 7 of 31


Report No.: 18C2057R-RF-US-P06V05


1.4. Tested System Details
The types for all equipments, plus descriptions of all cables used in the tested system (including
inserted cards) are:


Product            Manufacturer           Model No.          Serial No.        Power Cord
1 N/A              N/A                    N/A                N/A               N/A




                                             Page: 8 of 31


Report No.: 18C2057R-RF-US-P06V05


1.5. Configuration of Tested System


Test setup Diagram- Radiated Emission




                                        Page: 9 of 31


Report No.: 18C2057R-RF-US-P06V05


1.6. EUT Exercise Software

 1   Setup the EUT and simulators as shown on above.
 2   Turn on the power of equipment.
 3   Start to continue transmit.




                                            Page: 10 of 31


Report No.: 18C2057R-RF-US-P06V05


2.        Technical Test

2.1. Summary of Test Result

     No deviations from the test standards
     Deviations from the test standards as below description:


Performed Test Item             Normative References                             Limit     Result
Conducted Emission              FCC CFR Title 47 Part 15 Subpart C            FCC 15.207    N/A
                                Section 15.207
Field Strength of Spurious      FCC CFR Title 47 Part 15 Subpart C            FCC 15.209   PASS
                                Section 15.209
Channel Bandwidth               FCC CFR Title 47 Part 15 Subpart C            FCC 15.215   PASS
                                Section 15.215(c)
Antenna Requirement             FCC CFR Title 47 Part 15 Subpart C: Section   FCC 15.203   PASS
                                15.203


Performed Test Item             Normative References                             Limit     Result
Conducted Emission              RSS 216: Issue 2 Clause 6.2.2.1                RSS Gen      N/A

Field Strength of Spurious      RSS 216: Issue 2 Clause 6.2.2.2                RSS Gen     PASS

Channel Bandwidth               RSS Gen: Issue 5 Clause 6.7                    RSS Gen     PASS

Antenna Requirement             RSS Gen: Issue 5 Clause 6.8                    RSS Gen     PASS




2.2. Test Environment

              Items                      Required (IEC 68-1)                      Actual
Temperature (C)                                  15-35                             21
Humidity (%RH)                                    25-75                             50
Barometric pressure (mbar)                       860-1060                       950-1000




                                             Page: 11 of 31


Report No.: 18C2057R-RF-US-P06V05


3.        Conducted Emission

3.1. Test Equipment

Conducted Emission / TR-1
Instrument             Manufacturer      Type No.                Serial No.      Cal. Date        Cal. Due Date
EMI Test Receiver      R&S                ESCI                   100726          2018.03.29       2019.03.28
Two-Line V-Network     R&S                ENV216                 100043          2018.03.29       2019.03.28
Two-Line V-Network     R&S                ENV216                 100044          2018.09.17       2019.09.16
50ohm Coaxial
                       Anritsu           MP59B                   6200464462      2018.03.02       2019.03.01
Switch
50ohm Termination      SHX               TF2                     07081401        2018.09.17       2019.09.16
Temperature/Humidity
                       zhicheng          ZC1-2                   TR1-TH          2018.01.04       2019.01.03
Meter
Note: All equipment are calibrated with traceable calibrations. Each calibration is traceable to the national or
international standards.


3.2. Test Setup




                                                  Page: 12 of 31


Report No.: 18C2057R-RF-US-P06V05


3.3. Limit


                            FCC Part 15 Subpart C Paragraph 15.207 Limits

              Frequency                            QP                              AV
                (MHz)                            (dBuV)                          (dBuV)

              0.15 - 0.50                        66 - 56                        56 – 46

               0.50 - 5.0                           56                             46

                5.0 - 30                            60                             50

     Note 1: The lower limit shall apply at the transition frequencies.
     Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz
             to 0.5 MHz.


3.4. Test Procedure

     The EUT was setup according to ANSI C63.10 requirements. The EUT was placed on a
     platform of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting ground plane. The
     vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces of EUT
     were at least 80 cm from any other grounded conducting surface. The EUT and simulators are
     connected to the main power through a line impedance stabilization network (LISN). The LISN
     provides a 50 ohm /50uH coupling impedance for the measuring equipment. The peripheral
     devices are also connected to the main power through a LISN. (Please refer to the block
     diagram of the test setup and photographs) Each current-carrying     conductor of the EUT
     power cord, except the ground (safety) conductor, was individually connected through a LISN
     to the input power source.
     The excess length of the power cord between the EUT and the LISN receptacle were folded
     back and forth at the center of the lead to form a bundle not exceeding 40 cm in length.
     Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz
     using a receiver bandwidth of 9 kHz.


3.5. Uncertainty

     The measurement uncertainty is defined as ± 2.02 dB




                                             Page: 13 of 31


Report No.: 18C2057R-RF-US-P06V05


3.6. Test Result

Engineer: Damon

Site: TR1                                                       Time: 2019/01/04 - 16:02

Limit: FCC_Part15.207_CE_AC Power                               Margin: 0

Probe: ENV216_101190(0.009-30MHz)                               Polarity: Neutral

EUT: Wireless Charge Rack                                       Power: AC 120V/60Hz

Note: Mode1




No   Mark     Frequency    Measure Level   Reading Level   Over Limit       Limit     Probe    Cable    Amp      Type

                (MHz)         (dBuV)          (dBuV)         (dB)        (dBuV)       (dB)     (dB)     (dB)

 1                 0.154         53.687          44.065      -12.094         65.781    9.593    0.029    0.000     QP

 2                 0.154         40.571          30.950      -15.210         55.781    9.593    0.029    0.000     AV

 3                 0.206         48.660          39.032      -14.705         63.365    9.599    0.029    0.000     QP

 4                 0.206         38.265          28.638      -15.100         53.365    9.599    0.029    0.000     AV

 5                 0.278         40.144          30.514      -20.731         60.875    9.597    0.033    0.000     QP

 6                 0.278         32.444          22.814      -18.431         50.875    9.597    0.033    0.000     AV

 7                 0.442         32.786          23.154      -24.238         57.024    9.592    0.041    0.000     QP

 8                 0.442         22.132          12.499      -24.892         47.024    9.592    0.041    0.000     AV

 9                10.034         48.846          38.854       -11.154        60.000    9.791    0.201    0.000     QP

10      *         10.034         39.907          29.915      -10.093         50.000    9.791    0.201    0.000     AV

11                17.750         38.466          28.114      -21.534         60.000   10.081    0.271    0.000     QP

12                17.750         34.178          23.826      -15.822         50.000   10.081    0.271    0.000     AV




                                                       Page: 14 of 31


Report No.: 18C2057R-RF-US-P06V05




Engineer: Damon

Site: TR1                                                       Time: 2019/01/04 - 16:02

Limit: FCC_Part15.207_CE_AC Power                               Margin: 0

Probe: ENV216_101190(0.009-30MHz)                               Polarity: Line

EUT: Wireless Charge Rack                                       Power: AC 120V/60Hz

Note: Mode1




No   Mark     Frequency    Measure Level   Reading Level   Over Limit       Limit     Probe    Cable    Amp      Type

                (MHz)         (dBuV)          (dBuV)         (dB)        (dBuV)       (dB)     (dB)     (dB)

 1                 0.154         50.825          41.187      -14.956         65.781    9.609    0.029    0.000     QP

 2                 0.154         36.821          27.184      -18.960         55.781    9.609    0.029    0.000     AV

 3                 0.210         48.650          39.021      -14.555         63.205    9.601    0.029    0.000     QP

 4                 0.210         39.497          29.867      -13.708         53.205    9.601    0.029    0.000     AV

 5                 0.278         40.258          30.624      -20.617         60.875    9.600    0.033    0.000     QP

 6                 0.278         33.413          23.780      -17.462         50.875    9.600    0.033    0.000     AV

 7                 0.926         36.398          26.733      -19.602         56.000    9.608    0.058    0.000     QP

 8                 0.926         19.010           9.344      -26.990         46.000    9.608    0.058    0.000     AV

 9                10.030         50.145          40.173        -9.855        60.000    9.771    0.201    0.000     QP

10      *         10.030         41.988          32.016        -8.012        50.000    9.771    0.201    0.000     AV

11                11.930         48.177          38.136       -11.823        60.000    9.820    0.221    0.000     QP

12                11.930         39.652          29.611      -10.348         50.000    9.820    0.221    0.000     AV



Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
measurements as necessary.
                                                       Page: 15 of 31


Report No.: 18C2057R-RF-US-P06V05


2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).




                                              Page: 16 of 31


Report No.: 18C2057R-RF-US-P06V05


    4. Radiated Emission

4.1. Test Equipment

 Radiated Emission / AC-1
 Instrument                     Manufacturer     Type No.       Serial No.       Cal. Date       Cal. Due Date
 EMI Test Receiver              R&S      ESCI                   100573           2018.03.29      2019.03.28
 Loop Antenna                   R&S      HFH2-Z2                833799/003       2018.11.25      2019.11.24
 Bilog Antenna                  Teseq GmbH
                                         CBL6112D               27611            2018.10.11      2019.10.10
                                         SUCOFLEX
 Coaxial Cable              Huber+Suhner 106                    AC2-C            2018.03.02      2019.03.01
 Temperature/Humidity Meter Zhicheng     ZC1-2                  AC2-TH           2018.01.08      2019.01.07
 Note: All equipment are calibrated with traceable calibrations. Each calibration is traceable to the national or
 international standards.




                                                 Page: 17 of 31


Report No.: 18C2057R-RF-US-P06V05


4.2. Test Setup

     9kHz~30MHz Test Setup:




     30MHz~1GHz Test Setup:




                                    Page: 18 of 31


Report No.: 18C2057R-RF-US-P06V05


4.3. Limit

     Field strength of emissions from intentional radiators operated under 15.209(a) shall not
             exceed the following:
                                                     FCC Part 15.209(a)

             Fundamental frequency             Field strength of               Field strength of spurious
             (MHz)                             fundamental (μV/m)              emissions (μV/m)
             0.009-0.490                       2400/F(kHz)                                                300
             0.490-1.705                       24000/F(kHz)                                                30
             1.705-30.0                        30                                                          30
             30-88                             100**                                                           3
             88-216                            150**                                                           3
             216-960                           200**                                                           3
             Above 960                         500                                                             3


      (1) The tighter limits apply at the band edges.
      (2) Measurements were performed at 10m and the data was extrapolated to the
          specified measurement distance of 300m using the square of an inverse linear distance
          extrapolation factor (40 dB/decade) as specified in §15.31(f)(2). Extrapolation Factor = 40
          log10(300/10) = 59dB for example.


          Measurements were performed at 10m and the data was extrapolated to the
          specified measurement distance of 30m using the square of an inverse linear distance
          extrapolation factor (40 dB/decade) as specified in §15.31(f)(2). Extrapolation Factor = 40
          log10(30/10) = 19dB for example.


      (3) All measurements were performed using a loop antenna. The antenna was positioned in three
          orthogonal positions (X front, Y side, Z top) and the position with the highest emission level was
          recorded.



4.4. Test Procedure

     The EUT was setup according to ANSI C63.10 for compliance to FCC 47CFR 15.209
     requirements.
     The EUT is placed on a turn table which is 0.8 meter above ground. The turn table is rotated
     360 degrees to determine the position of the maximum emission level. The EUT was
     positioned such that the distance from antenna to the EUT was 10 meters.
     The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. This

                                                Page: 19 of 31


Report No.: 18C2057R-RF-US-P06V05


     is repeated for both horizontal and vertical polarization of the antenna. In order to find the
     maximum emission, all of the interface cables were manipulated according to ANSI C63.10 on
     radiated measurement.
     The frequency range from 9kHz to 10th harmonic is checked.


4.5. Uncertainty
     The measurement uncertainty is defined as ± 3.80 dB




                                             Page: 20 of 31


Report No.: 18C2057R-RF-US-P06V05


4.6. Test Result

Site: AC1                                                Time: 2018/12/17 - 10:08

Limit: FCC-15.209(10m) 9K-30M                            Margin: 0

Probe: loop antenna(0.009-30MHz)                         Polarity: Vertical

EUT: Wireless Charge Rack                                Power: AC 120V/60Hz

Note: Mode 1:




N   Mar     Frequency   Measure    Reading   Over        Limit       Probe    Cable   Amp     Ant    Table   Typ

o   k       (MHz)       Level      Level     Limit       (dBuV/      (dB/m)   (dB)    (dB)    Pos    Pos     e

                        (dBuV/m)   (dBuV)    (dB)        m)                                   (cm)   (deg)

1           0.064       43.289     32.435    -47.277     90.565      10.800   0.054   0.000   0      0       QP

2           0.089       39.145     28.267    -48.556     87.701      10.800   0.078   0.000   0      0       QP

3           0.116       39.068     28.163    -46.332     85.400      10.800   0.105   0.000   0      0       QP

4           0.128       40.638     29.722    -43.906     84.545      10.800   0.116   0.000   0      0       QP

5           0.141       39.679     28.750    -44.026     83.705      10.800   0.129   0.000   0      0       QP

6   *       0.145       44.099     33.166    -39.363     83.462      10.800   0.133   0.000   0      0       QP



Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).




                                              Page: 21 of 31


Report No.: 18C2057R-RF-US-P06V05




Site: AC1                                                       Time: 2018/12/17 - 10:54

Limit: FCC-15.209(10m) 9K-30M                                   Margin: 0

Probe: loop antenna(0.009-30MHz)                                Polarity: Vertical

EUT: Wireless Charge Rack                                       Power: AC 120V/60Hz

Note: Mode 1:




No   Mark   Frequency     Measure Level   Reading      Over        Limit      Probe     Cable   Amp     Ant       Table       Type

                (MHz)       (dBuV/m)       Level       Limit     (dBuV/m      (dB/m)    (dB)    (dB)    Pos       Pos

                                          (dBuV)       (dB)          )                                  (cm)      (deg)

 1                1.046         28.807      17.228    -17.492      46.298      10.600   0.979   0.000         0           0    QP

 2      *         1.340         27.155      15.572    -16.992      44.147      10.600   0.983   0.000         0           0    QP

 3                2.075         26.599      15.006    -22.028      48.627      10.600   0.993   0.000         0           0    QP

 4                3.493         29.858      18.242    -18.769      48.627      10.600   1.016   0.000         0           0    QP

 5                7.650         26.358      14.775    -22.270      48.627      10.500   1.083   0.000         0           0    QP

 6               13.568         25.575      14.105    -23.053      48.627      10.300   1.170   0.000         0           0    QP



Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).




                                                     Page: 22 of 31


Report No.: 18C2057R-RF-US-P06V05




Site: AC1                                                         Time: 2018/12/17 - 11:03

Limit: FCC-15.209(10m) 9K-30M                                     Margin: 0

Probe: loop antenna(0.009-30MHz)                                  Polarity: Horizontal

EUT: Wireless Charge Rack                                         Power: AC 120V/60Hz

Note: Mode 1:




No   Mark   Frequency     Measure Level   Reading Level   Over         Limit     Probe   Cable   Amp     Ant       Table       Type

                (MHz)       (dBuV/m)         (dBuV)       Limit       (dBuV/    (dB/m)   (dB)    (dB)    Pos       Pos

                                                          (dB)          m)                               (cm)      (deg)

 1                0.090         38.852          27.973    -48.752      87.604   10.800   0.079   0.000         0           0    QP

 2                0.102         32.925          22.034    -53.592      86.517   10.800   0.091   0.000         0           0    QP

 3                0.116         39.053          28.148    -46.347      85.400   10.800   0.105   0.000         0           0    QP

 4                0.128         39.533          28.617    -45.011      84.545   10.800   0.116   0.000         0           0    QP

 5                0.141         39.971          29.042    -43.734      83.705   10.800   0.129   0.000         0           0    QP

 6      *         0.145         40.415          29.482    -43.047      83.462   10.800   0.133   0.000         0           0    QP



Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
measurements as necessary.
2. " * ", means this data is the worst emission level.
     3. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).




                                                      Page: 23 of 31


Report No.: 18C2057R-RF-US-P06V05


Site: AC1                                                         Time: 2018/12/17 - 11:01

Limit: FCC-15.209(10m) 9K-30M                                     Margin: 0

Probe: loop antenna(0.009-30MHz)                                  Polarity: Horizontal

EUT: Wireless Charge Rack                                         Power: AC 120V/60Hz

Note: Mode 1:




No   Mark   Frequency     Measure Level   Reading Level   Over         Limit     Probe   Cable   Amp     Ant       Table       Type

                (MHz)       (dBuV/m)         (dBuV)       Limit       (dBuV/    (dB/m)   (dB)    (dB)    Pos       Pos

                                                          (dB)          m)                               (cm)      (deg)

 1      *         3.534         30.383          18.766    -18.244      48.627   10.600   1.017   0.000         0           0    QP

 2                7.564         26.825          15.244    -21.802      48.627   10.500   1.081   0.000         0           0    QP

 3                8.807         25.716          14.114    -22.912      48.627   10.500   1.102   0.000         0           0    QP

 4               16.023         25.362          13.859    -23.265      48.627   10.300   1.203   0.000         0           0    QP

 5               17.780         26.587          14.858    -22.040      48.627   10.500   1.229   0.000         0           0    QP

 6               20.120         26.283          14.426    -22.344      48.627   10.600   1.257   0.000         0           0    QP



Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).




                                                      Page: 24 of 31


Report No.: 18C2057R-RF-US-P06V05




Site: AC3                                                         Time: 2018/12/24 - 18:20

Limit: FCC_Part15.209_RE(3m)                                      Margin: 0

Probe: AC3_3m (30-1000MHz)                                        Polarity: Horizontal

EUT: Wireless Charge Rack                                         Power: AC 120V/60Hz

Note: Mode 1:




No   Mark   Frequency     Measure Level   Reading Level   Over         Limit     Probe   Cable   Amp     Ant       Table       Type

                (MHz)       (dBuV/m)         (dBuV)       Limit       (dBuV/    (dB/m)   (dB)    (dB)    Pos       Pos

                                                          (dB)          m)                               (cm)      (deg)

 1              155.372         28.696          11.330    -14.804      43.500   10.263   7.103   0.000         0           0    QP

 2              205.570         30.095          12.452    -13.405      43.500   10.342   7.301   0.000         0           0    QP

 3              221.818         30.449          12.227    -15.551      46.000   10.865   7.357   0.000         0           0    QP

 4              274.198         29.282           9.467    -16.718      46.000   12.279   7.536   0.000         0           0    QP

 5              427.579         32.964           5.930    -13.036      46.000   19.053   7.981   0.000         0           0    QP

 6      *       618.911         35.765           6.377    -10.235      46.000   20.908   8.480   0.000         0           0    QP



Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).




                                                      Page: 25 of 31


Report No.: 18C2057R-RF-US-P06V05




Site: AC3                                                         Time: 2018/12/24 - 18:25

Limit: FCC_Part15.209_RE(3m)                                      Margin: 0

Probe: AC3_3m (30-1000MHz)                                        Polarity: Vertical

EUT: Wireless Charge Rack                                         Power: AC 120V/60Hz

Note: Mode 1:




No   Mark    Frequency    Measure Level   Reading Level   Over          Limit    Probe    Cable   Amp     Ant       Table       Type

                (MHz)       (dBuV/m)         (dBuV)       Limit        (dBuV/    (dB/m)   (dB)    (dB)    Pos       Pos

                                                          (dB)           m)                               (cm)      (deg)

 1              100.082         29.147           7.066    -14.353      43.500    15.232   6.850   0.000         0           0    QP

 2              203.872         36.810          13.871     -6.690      43.500    15.643   7.296   0.000         0           0    QP

 3              247.038         35.521          12.195    -10.479      46.000    15.874   7.451   0.000         0           0    QP

 4              310.209         33.046           7.619    -12.954      46.000    17.778   7.649   0.000         0           0    QP

 5              769.019         39.255           6.932     -6.745      46.000    23.508   8.815   0.000         0           0    QP

 6       *      943.376         40.529           6.192     -5.471      46.000    25.149   9.189   0.000         0           0    QP



Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).




        Test Result         Pass


                                                      Page: 26 of 31


Report No.: 18C2057R-RF-US-P06V05


    5. 20dB Occupied Bandwidth

5.1. Test Equipment

 20dBc Occupied Bandwidth / AC-1
 Instrument                     Manufacturer     Type No.       Serial No.       Cal. Date       Cal. Due Date
 EMI Test Receiver              R&S      ESCI                   100573           2018.03.29      2019.03.28
 Loop Antenna                   R&S      HFH2-Z2                833799/003       2018.11.25      2019.11.24
 Bilog Antenna                  Teseq GmbH
                                         CBL6112D               27611            2018.10.11      2019.10.10
                                         SUCOFLEX
 Coaxial Cable              Huber+Suhner 106                    AC2-C            2018.03.02      2019.03.01
 Temperature/Humidity Meter Zhicheng     ZC1-2                  AC2-TH           2018.01.08      2019.01.07
 Note: All equipment are calibrated with traceable calibrations. Each calibration is traceable to the national or
 international standards.




                                                 Page: 27 of 31


Report No.: 18C2057R-RF-US-P06V05


5.2. Test Setup

     9kHz~30MHz Test Setup:




                                    Page: 28 of 31


Report No.: 18C2057R-RF-US-P06V05


5.3. Limit
      Intentional radiators operating under the alternative provisions to the general emission limits,
     as contained in §§15.215(c), must be designed to ensure that the 20 dB bandwidth of the
     emission, or whatever bandwidth may otherwise be specified in the specific rule section under
     which the equipment operates, is contained within the frequency band designated in the rule
     section under which the equipment is operated.

5.4. Test Procedure

     The bandwidth of the fundamental frequency was measured by spectrum analyzer with the
     RBW 1%~5% of 20dBc bandwidth and the VBW three times of the RBW. The 20dB bandwidth
     is defined as the total spectrum the power of which is higher than peak power minus 20dB.

5.5. Uncertainty

     The measurement uncertainty is defined as ± 10 Hz




                                            Page: 29 of 31


Report No.: 18C2057R-RF-US-P06V05


5.6. Test Result

      Product           Wireless Charge Rack
      Test Item         20dB Occupied Bandwidth
      Test Mode         Mode 1: Transmit
      Date of Test      2018/12/30                    Test Site           AC-1


                     Frequency       20dB Bandwidth         99% Bandwidth
                        (kHz)              (kHz)                  (kHz)
                      110~145            0.194                    0.524




     Test Result     Pass




                                           Page: 30 of 31


Report No.: 18C2057R-RF-US-P06V05


    6. Antenna Requirement

6.1. Requirement

Antenna Requirement Limit
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of
an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
comply with the provisions of this section. The manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector
is prohibited. This requirement does not apply to carrier current devices or to devices
operated under the provisions of §15.211, §15.213, §15.217, §15.219, or §15.221. Further, this
requirement does not apply to intentional radiators that must be professionally installed, such as
perimeter protection systems and some field disturbance sensors, or to other intentional radiators
which, in accordance with §15.31(d), must be measured at the installation site. However, the
installer shall be responsible for ensuring that the proper antenna is employed so that the limits in
this part are not exceeded.

6.2. Result

Antenna Connector Construction
     The use of a permanently attached antenna

     The antenna use of a unique coupling to the intentional radiator

     The use of a nonstandard antenna jack or electrical connector

Please refer to the attached document “Internal Photograph” to show the antenna connector.



                                              The End




                                             Page: 31 of 31



Document Created: 2019-03-26 22:59:36
Document Modified: 2019-03-26 22:59:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC